RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

Similar documents
HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

technical catalogue tetris KW Chiller and heat pumps air/water

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

UMXCA/UMXCBA ECVA/ECVBA

AHN 064 to 304 EHN/CHN 064 to 304

Air-Cooled Liquid Chiller with integrated hydraulic module

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Reversible air-to-water scroll heat pumps

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

WQL/WQH/WQRC 524 to 1204

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

AZURA. Air/water multifunctional chiller&heat pump, kw

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

AQWL/AQWH/AQWR 1404 to 2406

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Y-Flow TCHEY-THHEY

AQVSL/AQVSH STAR 85 to 140

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

... RTU Technical Manual. Packaged Air Conditioning Unit...

CATÁLOGO TÉCNICO COMERCIAL

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

ENR Incorporating

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CWP-CO / CWP-RC / CWP-HP 02 to 35

RECU-NOVO. heat recovery unit

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CXAM. Options. Accessories

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

Epsilon Echos DK kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

D M S 760 C01 A A 1 1

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

ERACS2-WQ. Climaveneta Technical Bulletin ERACS2_WQ_0802_3202_201002_GB. Units for 4 pipes-systems water source kw

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

OMICRON V EVO. Multifunctional unit

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

GH Hydro Kits. Technical Information. Ref: N

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Application guide ECOLOGIC

PCB COMMERCIAL SERIES

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw

Product Catalogue ARMONIA Providing indoor climate comfort

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

CGA CXA VGA VXA CG-PRC006-E4

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

TRI-CAPACITY PACKAGE UNIT

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions

Conditioning your ambient, maximising your comfort.

TEAL FC. Chiller with integrated Free Cooling system kw

30HXC. Water-Cooled Screw-Compressor Liquid Chillers. Nominal cooling capacity kw. Features

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Multi-pipe units with scroll compressors

VTZ variable speed Reciprocating compressors

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

HWT 1402/9603. free cooling

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

GUIDE SPECIFICATIONS. ES Series R-410A

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

FOCS2-W/CA-E. Climaveneta Technical Bulletin FOCS2_W_CA_E_1301_4802_201001_GB. High effi ciency water-cooled chillers kw

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

Secondary Coolant 301

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

SyScroll Air EVO NEW

Transcription:

Cooling capacity: Heating capacity: 17,7 to 74,3 kw 21,8 to 84,8 kw Scroll compressors R-410A refrigerant Compact and silent design Cooling solution where an outdoor installation is impossible DESCRIPTION The / ILP cooling only and reversible heat pumps are compact outdoor air/water units. Available in two versions: (Standard) and HEE (High Energy Efficiency). These units have been made for operation indoors in the production of hot and/or cold water, applicable to heating, cooling, and industry. They are equipped with centrifugal fans ( version) or electronic plugfans (HEE version), plate exchangers, hermetic scroll compressors, and electronic control with microprocessors, components optimised for the R-410A refrigerant. This range is also offered with an integrated circulation pump: LPC / ILPC and optionally, with a hydraulic module (attached to the unit or independent) equipped with a buffer tank. The entire range also has the option to include a desuperheater circuit that allows for the production of hot water at a temperature greater than in the condensation circuits. All units are charged with refrigerant and are tested at the factory, verifying the correct operation of all their components. SERIES Air-condensed water chillers. ILP Reversible heat pump units for operation in negative outdoor temperatures (greater than -1ºC WB) for water heating and cooling. Defrosting by reversing the cycle. RANGE Version (Standard): Units 1 cooling circuit, 1 compressor, models: 90 / 100 / 120 / 10 / 180 Units 1 cooling circuit, 2 compressors, models: 200 / 240 / 280 / 320 / 30 HEE Version (High Energy Efficiency): Units 1 cooling circuit, 1 compressor, models: 90 / 100 / 120 / 10 / 180 Units 1 cooling circuit, 2 compressors, 3 models: 200 / 240 / 280 OPERATION LIMITS Series Air Cooling mode Water (outlet T.) Heating mode With control of operation condensation pressure up to -1ºC. Minimum outlet temperature. With the option of glycol water for lower temperature operation from ºC to -10ºC. Air Water (outlet T.) Max. Min. Max. Min. Max. Min. Max. Min. LP 4ºC 12ºC 18ºC ºC -- -- -- -- ILP 4ºC 12ºC 18ºC ºC 20ºC DB -1ºC DB ºC 30ºC

DESIGNATION series model version example ILPC-90V- I = heat pump = stardard HEE = high efficiency heat pumpr standard version LP = air-water unit with scroll compressor and centrifugal fan V = 10A C = with circulation pump (optional) series circulation pump 10A model UNIT COMPONENTS Casing - Casing made of galvanised steel metal with polyester paint, colour RAL 70. Self-supporting frame. Outdoor circuit - Coil(s) with copper pipes and aluminium fi ns. - Condensate drain pan. - Choice of air discharge position: HORIONTAL (M00 assembly) or VERTICAL (M01 assembly). M00 M01 Indoor circuit - Thermally isolated, welded stainless steel plate exchanger. Cooling circuit - Hermetic scroll-type compressor(s), assembled over antivibration mounts. Control of phase equilibrium and the direction of rotation. - Crankcase heater. - Thermostatic expansion valve(s) with external equalisation. - Anti-acid dehydrating fi lter(s) - Liquid receiver(s) (heat pump units). - Liquid sight glass. - Particle separator (models 200 to 30). - Four-way cycle reversing valves (heat pump units). - Outlet fan(s): Version (Standard): Centrifugal fan(s) coupling by pulleys and belts. Electric motor(s) with tensioner, energy-efficient IE2 motors, class F, IP, and internal thermal protection. One double-intake turbine, with an impeller with front-curved blades. Greased spherical bearings, with no maintenance required. Choice of available pressure from 7 to mm.a.c. HEE Version (High Energy Efficiency): Variable speed electronic plug-fan(s) with condensation pressure control which adapt their rotation speed to the installation requirements, thereby reducing electricity consumption, the sound level at partial charge, and improving the average seasonal output of the unit (ESEER). Energy-effi cient ErP 201 motor, Class F, IP4, and internal thermal protection. Protections - High pressure pressostat. - Low pressure pressostat (with μchiller 2 ) or safety device integrated into the control (with CONNECT2). - Water fl ow controller. - Water anti-freeze protection built into the control. - Water anti-freeze thermostat as additional safety. - Compressor discharge temperature control. - Non-return valve built into the compressor discharge. - Compressor thermal protection. - Main door switch. - Automatic switch in the control circuit. - Magnetothermic protection switches for the compressor(s) power line and fan motor. - Timing the disconnection of the circulation pump. - Failure safety device for the circulation pump. - Complete and fully wired electric panel. Insulated panel cover to prevent condensation. IP protection - Power supply with neutral and main ground connection. - Compressor(s) and fan motor(s) contacts.

Version with circulation pump included (LPC / ILPC) This version includes, in the same casing that the LP / ILP version, the following components: - Monocellular IP centrifugal circulation pump that can operate with glycol water (mono-ethylene glycol). The pump must be changed for mono-propylene glycol (upon request). - Closed expansion vessel. - Safety valve with a tare value of 4 bar. - Draining valve. - Automatic air bleeder valve (in models 200 to 30). - Filter with stainless steel mesh (800 microns), supplied in the kit for installation by the installer. This one includes a thermal buffer tank made of black stainless steel, painted, and thermally insulated, with an anti-freeze electrical heater (1kW). This heater has the option to be replaced by a support heater to heating in one or two stages (from 3 kw to 3kW). The module can be supplied coupled to the LPC / ILPC unit or separate for connection on site by the installer. In this case, the fl exible connections of 00 mm (option) are recommended. Note: the antifreeze protection with fl exible electric heaters on the hydraulic circuit piping (option) is not available with separate hydraulic module (see options). LPC / ILPC Expansion vessel Circulation pump Hydraulic module Units with LPC / ILPC version can be coupled to a hydraulic module. LPC / ILPC Hydraulic module Electronic control μchiller 2 control (1-compressor models of the version) Control system by microprocessor made by: Composition User interface control integrated in the control. Connector for μc 2 control panel. Auxiliary card for controlling cooling/heating remotely. Possibility of connecting to a supervision network through a standard RS48 serial line. Functions Control of the water s temperature. Control and optimisation of the operation parameters and management of safety devices. Anti-short-circuit timing. Management of the defrosting by time and/or temperature and/or pressure. Circulation pump control. Management of the auxiliary electrical heater. Remote on/off control. Compensation of the setpoint based on the outdoor temperature, with the possibility of choosing a different compensation constant for cooling and heating. User interface panel Display with 3 green digits (plus sign and decimal point or comma) and icons for indicating the operations of: compressor(s), pumps, fans, defrosting operations, electrical heaters, alarms, COOLING mode, and HEATING mode. Keyboard for configuring the operation parameters and unit alarms. Reading of pressures and temperatures. Management of safety devices. Failure management. Buffer tank 7

μc 2 control panel Panel composed of a liquid crystal display and a keyboard that allows: Selection of the operating mode: heating or cooling. Management of the operating parameters (setpoints, differential and timings). Display of setpoints, time and temperature of the water inlet to the evaporator. On-screen display of alarms. Auxiliary card (optional) Selection of remote cooling/heating operating mode. Selection of 1/2 setpoints. Serial RS48 outputs MODBUS - JBUS open protocol (standard). HP/LP, water fl ow, compressor motor(s), anti-frost. Remote management and surveillance. Master/slave management capable of managing two units in a single water loop, alternating the Master and Slave based on the operating times. Hourly and weekly programming. Local control panel Ergonomic interface panel with multi-lingual LCD display (4 lines of 24 characters each) and LED indicators. Functions Reading of pressures and temperatures. Operating state and fault diagnostics. Master/slave management of two parallel-connected machines. Fault memory management. Pumps management. Hourly and weekly programming. CONNECT2 control (2-compressor models of the version and all models of the HEE version) Electronic control module with microprocessor and CPU, central automation, and access to the internal operating states. Composition of the main board Input for adquisition of sensors reading and operating state of components. Outputs for circulation pump control, stages connection, and general failure signal. Connector for local control panel, installed on the unit. Connector for remote control panel (optional). Connector for relay card (optional). Connector for management - MULTICONNECT (optional). RS48 output via the MODBUS-JBUS protocol for the GTC link. Functions Run, Stop, Reset or Remote control functions. Selection of COOLING or HEATING operating mode. Display of the information related to operations for direct display of multi-lingual messages in clear text. Direct display of the water temperatures and pressures. Complete management of compressors with a start-up sequence, count, and equalisation of operating times. Anti-short-circuit protection. Auto-adaptive and pro-active functions, adjusting the control in the compensation for the parameters. Device to reduce the stratifi ed power being cascaded to the multicompressors, based on the cooling or heating needs controlled by the water temperatures. Control of the internal operating parameters. Management of auxiliary electrical heater working alone or simultaneous to the heating pump. Adjustment of the setpoint with a 4-20 ma signal. Management of a second setpoint. Diagnosis of the operating and failure states: Remote control panel (optional) Functions and design identical to the local panel. Relay board (optional) Volt-free contacts card for display of the operation state and signalling of components failure. Available outputs: Failures: water flow, antifreeze, pump, fans, high and low pressures, compressors safety, discharge temperature. Operation state of compressors. Multigroups management - MULTICONNECT (optional) Main functions available: Management of up to 8 units in a single water loop. Management in COOLING mode (cold water group) or HEATING mode (heat pump). Management of the cold water or hot water network pumps. Integrated management of an backup unit. Unit load shedding. Timer programming of the installation. Management of the energy storage method. Balancing of the unit operating times. RS48 output via the MODBUS-JBUS protocol for the GTC link. Serial RS48 outputs MODBUS - JBUS open protocol (standard). LONWORKS protocol (optional). ETHERNET bridge (standard). 8

Options Pumps The pump installed on a unit LPC / ILPC can be replaced for: - High-pressure, monocellular, IP, circulation pump that can operate with glycol water (mono-ethylene glycol). - Low-pressure, monocellular, IP, circulation pump that can operate with glycol water (mono-ethylene glycol) (except in model 90). - Double circulation pump with automatic switching for operation between the two pumps (models 200 to 30). This option is available in units that have the standard or high-pressure pump. Configuration - VERTICAL air discharge, M01 assembly (default horizontal discharge, M00 assembly). - In the version: Different confi gurations of available pressure from 7 to mm.a.c. (default 7 mm.a.c.). Acoustic - Acoustic insulating cover for compressor (LOW NOISE version). Climatic conditions - In the version: Condensation pressure control by the damper with proportional control for operation during all seasons (up to -1 C). Damper Servomotor Comfort / heating - Electrical heater for support in heating in the hydraulic module, available in one or two stages: 3kW / kw / 8kW / 12kW / 24kW (12+12) / 3kW (24+12) Note: this electrical heater replaces theanti-freeze electrical heater (1kW) which incorporates the buffer tank as standard. Energy recovery Desuperheater circuit which includes: - Thermally isolated, welded stainless steel plate exchanger for working in a closed circuit in the recovery of hot gases. - Draining valve and ball valve - Hot water recovery control thermostat. - Option for a 3-speed hot water circulation pump. Installation - Antivibration mounts made of rubber. - Protection grille for the coil. - Gravimetric fi lters in the return air. The fi lters frame is removable, and upon request, it is possible to supply the frame independently with the unit LP, to be joined on site. - Flexible ducts for outlet and return air. - Flexible hydraulic connections (00 mm), supplied in the kit. Available for: Inlet / outlet of the unit Inlet / outlet of the desuperheater circuit Connection between the unit and the independent hydraulic module. - Filter with stainless steel mesh (800 microns), supplied in the kit. Note: optional for LP / ILP units and standard for LPC / ILPC units. - Cut-off and water control valves, supplied in the kit. - High-pressure and low-pressure gauges in the cooling circuit. - Compressor soft starter. - Transformer for power supply without neutral. - Voltage 400 / 440V - 0 Hz (upon request). Control / communications management - Coils protection: Coil with copper pipes and copper fi ns (upon request). Coil with copper pipes and aluminium fi ns with polyurethane and blygold coating. - During periods with low outdoor temperatures, anti-freeze protection for the unit: Electrical heaters in the condensate drain pan. Mandatory when outdoor temperatures are below 3 C. Operation with glycol water up to a minimum outlet temperature of -10ºC. Thermal insulation of the body 18 mm thick. Mandatory with negative conditions. Anti-freeze protection with fl exible electrical heaters around the pipe of the hydraulic circuit. This option is not available in the LPC / ILPC units with separate hydraulic module. μchiller 2 control - Outdoor temperature probe. - Auxiliary card for controlling cooling/heating remotely. - RS48 communication card. CONNECT2 control - Change to CONNECT2 electronic control for units with μchiller 2 control (1-compressor models of the version). - Remote control panel. - Kit for realy board (volt-free contacts). - Multi-groups management - MULTICONNECT. - Kit for LonWorks bridge. - Kit for a master / slave control probe (necessary in case of a regulation in the water outlet). 9

VERSION: TECHNICAL CHARACTERISTICS Cooling capacities Heating capacities Outdoor circuit centrifugal fan / ILP 90V- 100V- 120V- Net cooling capacity (kw) 17,72 21,12 2,1 32,8,9 43,72 49,30,73 8,00 74,31 Net power input (kw) 7,7 9,11 10,00 12,44 14,27 17,9, 22,21 24,1 28,42 Net EER performance 2,28 2,32 2,2 2,3 2,2 2,0 2,1 2,1 2,7 2,1 ESEER 2,0 2,1 2,84 2,98 2,88 3,38 3,37 3,01 3, 3,7 Net heating capacity (kw) 21,77 2,11 29,9 38,30 42,, 8,7,89 7,3 84,78 Net power input (kw) 7,29 8,83 9,8 12,74 14,01 17,19,49 22,1 24, 27,88 Net COP performance 2,98 2,9 3,01 3,01 3,0,01 3,01 3,02 3,12 3,04 Nominal air flow (m 3 /h) 00 0 10000 12200 12200 1000 20000 24400 24400 24400 Available static pressure (mm.a.c.) 7 Number / turbines 1 / 1 2 / 2 Motor output (kw) 1, 2,2 2,2 3,0 3,0 2 x 2,2 2 x 2,2 2 x 3,0 2 x 3,0 2 x 3,0 Power input (kw) 1,0 1,31 1,73 2,02 2,02 2,2 3,47 3,72 4,03 4,03 Speed (r.p.m.) 821 88 723 27 27 741 723 9 27 27 10V- 180V- 200V- 240V- 280V- 320V- 30V- Nominal water flow (m 3 /h) 3,1 3,7 4,3,7,2 7, 8, 9, 11,7 12,8 Pressure drop (m.w.c.) 2,3 3,2 2,9 4,7 2,9 4,2 3,2 4,0 2,1 2, Indoor circuit Minimum water flow (m 3 /h) 2,2 2,7 3,1 4,1 4,3 4,7,2 7,2 8,3 8, Maximum water flow (m 3 /h),2 7,4 8,8 11,3 12,7 1,0 17,9,2 23, 2,0 Type of hydraulic connections Gas threaded Diameter of connections M 1 1/4" M 1 1/2" M 2" Type Scroll Number 1 2 Compressor Number of circuits 1 Number of stages 1 2 Oil type Copeland 3MAF 32 cst, Danfoss POE 10 S, ICI Emkarate RL 32 CF, Mobil EAL Artic 22 CC Volume of oil (l) 3,0 3,3 3,3 3,3,2 2 x 3,3 2 x 3,3 2 x 3,3 2 x 3,3 2 x,2 Refrigerant Electrical characteristics Maximum absorbed current Type R-410a Global warming potential (GWP) 2.088 Charge (kg),9,1,,9 7, 9,2,3 12,4 14,9 1,4 Electrical power supply 400 V / III ph / 0 Hz (±10%) Power supply 3 Wires + Ground + Neutral Compressor(s) (A) 1,3 18, 20,1 2,1 29,1 37,0 40,2 4,0 0,2 8,2 Fan(s) (A) 3,,0,0,9,9 10,0 10,0 13,8 13,8 13,8 Control (A) 0,9 0,9 0,9 0,9 0,9 1,8 1,8 1,8 1,8 1,8 Total (A) 19,8 24,4 2,0 32,9 3,9 48,8 2,0 1,,8 73,8 Length (mm) 1117 1398 2113 273 Dimensions Width (mm) 80 Height (mm) 1437 1717 1437 1717 Weight Empty (kg) 297 310 39 387 38 8 38 70 704 710 In operation (kg) 301 31 37 3993 73 3 8 722 727 Cooling capacity calculated in accordance with the UNE-EN-1411 standard given for outlet water temperature conditions of 7ºC and ºC outdoor temperature. Heating capacity calculated in accordance with the UNE-EN-1411 standard given for outlet water temperature conditions of 4ºC and ºC WB outdoor temperature. Total power input by compressor(s), motorised fan(s), and electronic controls under nominal conditions, calculated in accordance with the UNE-EN-1411 standard. Options are not included. European Seasonal Energy Effi ciency Ratio (ESEER) obtained in accordance with the calculation conditions established by the certifi cation body EUROVENT. Energy-effi cient motors IE2. Climatic warming potential of a kilogram of fluorinated greenhouse gas in relation to a kilogram of carbon dioxide over a period of 100 years. 11

VERSION: TECHNICAL CHARACTERISTICS WITH PUMP INCLUDED LPC / ILPC C / ILPC 90V- 100V- European Seasonal Energy Efficiency Ratio ESEER 2,7 2,3 2,87 3,02 2,87 3,41 3,39 3,02 3, 3,7 120V- 10V- 180V- 200V- 240V- 280V- 320V- 30V- Indoor circuit Expansion vessel Nominal water flow (m 3 /h) 3,1 3,7 4,3,7,2 7, 8, 9, 11,7 12,8 Pressure drop (m.w.c.) 3,1 4,2 3,8,2 4, 4,9 4,1,1 3, 4,3 Volume (l) 12 20 Filled pressure (kg/cm 2 ) 1, Volume of the buffer tank (l) 100 22 Buffer tank (LPC / ILPC + module) Hydraulic connections Dimensions Maximum water capacity Water 40ºC (l) 0 0 of the installation Water 0ºC (l) 410 30 2 Drained diameter M 3/4 M 1 Anti-freeze elec. heater (standard) Voltage 230 V / I ph Output (kw) 1 (4,3 A) Type Gas threaded Diameter M 1 1/4" M 1 1/2" M 2 LPC / ILPC 1117 1398 2113 273 Length (mm) LPC / ILPC + module 2117 2398 3113 373 Width (mm) 80 Height (mm) 1437 1717 1437 1717 Weight LPC / ILPC LPC / ILPC + module Empty (kg) 313 328 387 40 40 80 0 94 730 7 In operation (kg) 330 34 407 42 4 9 730 78 774 Empty (kg) 42 4 48 742 829 83 899 904 In operation (kg) 72 87 723 741 74009 1099 1133 117177 The water capacity for the installation indicated in this table corresponds to the maximum that the installation allows based on the expansion vessel assembled on the unit. The volume of the buffer tank has been taken into account for this section. In case the capacity of the installation is greater, it is necessary to add a supplementary expansion vessel to the installation based on its volume. This temperature corresponds to the temperature that the circuit must reach when the unit is stopped. This case must be considered for cooling-only units. This temperature corresponds to the maximum temperature that the circuit may reach when operating in a heat pump. LP / ILP pressure drop (m.w.c.) 2 20 1 10 9 8 7 4 90V- / 100V- 120V- / 10V- 180V- / 200V- 240V- / 280V- 320V- / 30V- LPC / ILPC pressure drop (m.w.c.) 2 20 1 10 9 8 7 4 90V- /100V- 120V- / 10V- 180V- 200V- 240V- / 280V- 320V- /30V- 3 3 2 2 1 2 3 4 7 8 9 10 1 20 2 30 3 Flow (m /h) 1 2 3 4 7 8 9 10 1 20 2 30 3 Flow (m /h) 12

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 90V- / 100V- horizontal DISCHARGE, M00 assembly (mm) 70 89 27 80 101 744 1019 9 7 13 1117 1437 0,m 920 HORIONTAL outdoor circuit air discharge 100 97 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 90V- 43 384 28 301 100 8 0 100V- 488 398 7 31 9 93 84 0 90V- 17 39 77 330 80 9 8 9 100V- 1 402 74 82 99 90 73

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 90V- / 100V- vertical DISCHARGE, M01 assembly (mm) 70 89 80 144 1437 101 744 9 7 13 1117 0,m 172 41 2 VERTICAL outdoor circuit air discharge 97 100 920 410 482 214 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 90V- 43 384 28 301 100 8 0 100V- 488 398 7 31 9 93 84 0 90V- 17 39 77 330 80 9 8 9 100V- 1 402 74 82 99 90 73 3

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 120V- / 10V- / 180V- horizontal DISCHARGE, M00 assembly (mm) 70 11 80 1387 894 1220 470 1717 27 7 101 9 13 1398 0,m 1201 HORIONTAL outdoor circuit air discharge 100 97 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 120V- 2 399 7 37 88 111 100 77 10V- 19 400 394 91 118 10 79 180V- 2 397 793 917 104 79 120V- 4 402 73 407 98 11 10 87 10V- 39 402 3 401 123 112 90 180V- 4 400 9 403 122 91 37

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 120V- / 10V- / 180V- vertical DISCHARGE, M01 assembly (mm) 70 80 1717 11 1387 1744 894 7 101 9 13 1398 0,m 128 13 202 VERTICAL outdoor circuit air discharge 97 100 1201 08 7 312 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 120V- 2 399 7 37 88 111 100 77 10V- 19 400 394 91 118 10 79 180V- 2 397 793 917 104 79 120V- 4 402 73 407 98 11 10 87 10V- 39 402 3 401 123 112 90 180V- 4 400 9 403 122 91 38

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 200V- horizontal DISCHARGE, M00 assembly (mm) 70 1892 148 80 2102 101 744 27 148 1019 9 7 13 2113 1437 0,m 188 HORIONTAL outdoor circuit air discharge 77 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm Weight LP / ILP 200V- 930 427 7 73 120 14 12 LPC / ILPC 200V- 99 430 7 1 13 1 1743 39

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 200V- vertical DISCHARGE, M01 assembly (mm) 70 1437 1892 80 2102 144 101 744 148 9 7 13 2113 0,m 171 41 27 VERTICAL outdoor circuit air discharge 188 410 484 482 214 77 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm Weight LP / ILP 200V- 930 427 7 73 120 14 12 LPC / ILPC 200V- 99 430 7 1 13 1 1743 40

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 240V- / 280V- / 320V- / 30V- horizontal DISCHARGE, M00 assembly (mm) 101 892 148 148 1220 470 27 70 9 13 7 242 80 22 0,m 273 1717 242 HORIONTAL outdoor circuit air discharge Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm 97 LP ILP LPC ILPC 1,m Weight 240V- 112 424 80 3 139 18 188 141 280V- 112 423 80 8 14 19 197 148 320V- 1189 420 729 203 208 30V- 1184 420 72 727 10 20 204 18 240V- 1199 42 80 9 13 199 1 280V- 1199 42 77 730 10 201 20 14 320V- 122 422 4 78 174 209 210 17 30V- 1220 422 70 774 17 212 217 41

DIMENSION SCHEMES FOR THE VERSION LP / ILP / LPC / ILPC - 240V- / 280V- / 320V- / 30V- vertical DISCHARGE, M01 assembly (mm) 70 101 892 148 1744 0,m 128 9 7 242 80 22 13 202 273 13 1717 242 709 7 312 7 VERTICAL outdoor circuit air discharge Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm 97 LP ILP LPC ILPC 08 1,m Weight 240V- 112 424 80 3 139 18 188 141 280V- 112 423 80 8 14 19 197 148 320V- 1189 420 729 203 208 30V- 1184 420 72 727 10 20 204 18 240V- 1199 42 80 9 13 199 1 280V- 1199 42 77 730 10 201 20 14 320V- 122 422 4 78 174 209 210 17 30V- 1220 422 70 774 17 212 217 42

DIMENSION SCHEMES FOR THE VERSION LPC / ILPC with hydraulic module (mm) 70 R G G R 80 E F B 8 147 713 C D 0,m LPC / ILPC + module Dimensions (mm) A B C D E F G H 90V- 2117 1437 11100 1000 948 1200 A 100V- 2117 1437 11100 1000 948 1200 120V- 2398 1717 1393 100 1387 1000 1089 0 10V- 2398 1717 1393 100 1387 1000 1089 0 180V- 2398 1717 1393 100 1387 1000 1089 0 200V- 3113 1437 2108 100 210000 144 1200 240V- 373 1717 28 100 2000 172 0 H 843 280V- 373 1717 28 100 2000 172 0 320V- 373 1717 28 100 2000 172 0 30V- 373 1717 28 100 2000 172 0 Discharge of condensates and tank drain Note: the hidraulic connections 1 2 stand out 8 mm LPC / ILPC + module Weight R R 90V- 871 40 40 72 0 141 107 433 99 100V- 408 87 47 144 112 40 137 10 120V- 1013 409 73 723 7 177 9 19 121 10V- 997 409 741 18 8 173 127 180V- 1001 407 70 742 8 18 8 173 12 200V- 1337 428 77 1009 90 239 17 9 24 172 240V- 110 42 78 1099 10 277 109 81 280V- 109 42 7 1133 109 270 183 112 273 187 320V- 111 422 11714 281 191 11 281 191 30V- 10 422 70 1177 114 28914 2893 43

DIMENSION SCHEMES FOR THE VERSION Independent hydraulic module (mm) 70 790 1000 Ø A 8 7 C B 843 1 1010 71 93 LPC / ILPC + module Dimensions (mm) A B C H Ø Module Connec. Ø Unit Connec. 90V- 1437 74 17 1200 1 1/4 M 1 1/4 H 100V- 1437 74 17 1200 1 1/4 M 1 1/4 H 120V- 1717 8 17 0 1 1/2 M 1 1/2 H H 10V- 1717 8 17 0 1 1/2 M 1 1/2 H 180V- 1717 8 17 0 1 1/2 M 1 1/2 H 200V- 1437 74 17 1200 2 M 2 H 240V- 1717 8 17 0 2 M 2 H 280V- 1717 8 17 0 2 M 2 H 320V- 1717 8 17 0 2 M 2 H 30V- 1717 8 17 0 2 M 2 H LPC / ILPC + module Weight 90V- 498 448 48 242 4 7 100V- 498 448 48 242 4 7 LEENDA Tank drain 7 Water inlet to the tank 8 Water outlet from the tank 120V- 498 42 08 31 73 70 8 88 10V- 498 42 08 31 73 70 8 88 180V- 498 42 08 31 73 70 8 88 200V- 79 47 73 393 9 10 128 91 240V- 77 4 13 404 708 130 93 280V- 77 4 13 404 708 130 93 320V- 77 4 13 404 708 130 93 30V- 77 4 13 404 708 130 93 44

DIMENSION SCHEMES FOR THE VERSION Condensation pressure control damper (mm) 90V- to 180V- models 200V- to 30V- models B D A F F E G B F E D A Q P E G F C K L N J M C K J L M N K O K O N I H I O I H I O N LP / ILP / LPC / ILPC Assembly A B C D E F G H I J K L M N O P Q 90V- / 100V- 978 44 89 84 1 3 x 2 49 39 1 29 4 11 -- -- 120V- / 10V- / 180V- 128 20 117 112 1 4 x 29 49 470 1 370 4 11 -- -- M00 200V- 1970 428 1892 901 1 x 348 7 378 1 327 39 11 40 1842 240V- / 280V- / 320V- / 30V- 282 0 2412 1 x 384 7 00 1 447 41 10 12 2402 90V- / 100V- 33 (*) 428 0 00 1 1 x 400 7 378 1 278 4 11 -- -- 120V- / 10V- / 180V- 733 (*) 0 0 00 1 2 x 20 7 00 1 400 4 11 -- -- M01 200V- 142 (*) 49 10 720 1 4 x 0 7 497 1 447 41 10 0 0 240V- / 280V- / 320V- / 30V- 2243 (*) 47 020 1 x 333 7 497 1 447 41 10 0 2100 (*) In the case of vertical discharge (M01 assembly) damper incorporates a frame (0 mm height) to fi t the damper to the fan(s) outlet. This frame may be removed for duct installation. M00 assembly M01 assembly Note: By default this damper is sent attached to the unit. For duct installation it is necessary to unscrew from the unit and disconnect the electrical supply of the servomotor. 4

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 90V-HEE horizontal DISCHARGE, M00 assembly (mm) 70 89 27 80 101 744 1019 9 7 13 1117 1437 0,m 920 HORIONTAL outdoor circuit air discharge 100 97 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm Weight LP / ILP 90V-HEE 02 424 298 4 100 8 0 LPC / ILPC 90V-HEE 38 427 99 327 77 84 87 79 4

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 90V-HEE vertical DISCHARGE, M01 assembly (mm) 70 89 80 144 1437 101 744 9 7 13 1117 0,m 1 73 1 13 VERTICAL outdoor circuit air discharge 97 100 920 03 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm Weight LP / ILP 90V-HEE 02 424 298 4 100 8 0 LPC / ILPC 90V-HEE 38 427 99 327 77 84 87 79 47

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 100V-HEE / 120V-HEE horizontal DISCHARGE, M00 assembly (mm) 70 80 27 894 1220 470 1717 7 101 9 13 1398 1201 11 1387 0,m HORIONTAL outdoor circuit air discharge 100 97 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 100V-HEE 9 417 73 8 3 127 11 2 120V-HEE 28 42 742 37 88 1100 77 100V-HEE 38 418 23 390 88 109 107 8 120V-HEE 9 427 74 408 100 101 104 103 48

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 100V-HEE / 120V-HEE vertical DISCHARGE, M01 assembly (mm) 70 11 80 1387 1744 1717 894 7 101 9 13 1398 0,m 130 83 130 VERTICAL outdoor circuit air discharge 97 100 1201 4 803 230 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 100V-HEE 9 417 73 8 3 127 11 2 120V-HEE 28 42 742 37 88 1100 77 100V-HEE 38 418 23 390 88 109 107 8 120V-HEE 9 427 74 408 100 101 104 103 49

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 10V-HEE / 180V-HEE horizontal DISCHARGE, M00 assembly (mm) 70 1892 148 80 2102 27 101 744 148 1019 9 7 13 2113 1437 0,m 188 HORIONTAL outdoor circuit air discharge 77 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 10V-HEE 940 4 73 4 9 177 13 180V-HEE 93 434 79 48 71 178 13 10V-HEE 97 43 70 497 109 130 140 118 180V-HEE 972 43 7 03 13419 0

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 10V-HEE / 180V-HEE vertical DISCHARGE, M01 assembly (mm) 70 1892 80 2102 144 1437 101 744 148 9 7 13 2113 1 0,m 1 73 13 VERTICAL outdoor circuit air discharge 188 349 03 394 03 77 1,2m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 10V-HEE 940 4 73 4 9 177 13 180V-HEE 93 434 79 48 71 178 13 10V-HEE 97 43 70 497 109 130 140 118 180V-HEE 972 43 7 03 13419 1

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 200V-HEE / 240V-HEE / 280V-HEE horizontal DISCHARGE, M00 assembly (mm) 70 101 892 148 148 1220 470 27 9 13 273 7 242 80 22 0,m 1717 242 HORIONTAL outdoor circuit air discharge 97 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 200V-HEE 111 440 4 48 10 213 218 111 240V-HEE 1203 43 4 74 143 191 194 14 280V-HEE 1198 4 42 80 14 193 19 14 200V-HEE 1221 441 90 147 180 198 1 240V-HEE 127 437 3 717 10 183 198 17 280V-HEE 122 43 34 724 187 200 17 2

DIMENSION SCHEMES FOR THE HEE VERSION LP / ILP / LPC / ILPC - 200V-HEE / 240V-HEE / 280V-HEE vertical DISCHARGE, M01 assembly (mm) 101 892 148 1744 0,m 70 1 9 7 242 80 22 73 13 1 273 1717 242 03 291 73 03 VERTICAL outdoor circuit air discharge 97 492 1,m Condensate outlet: pipe 22 mm Note: the hidraulic connections 1 2 stand out 8 mm LP ILP LPC ILPC Weight 200V-HEE 111 440 4 48 10 213 218 111 240V-HEE 1203 43 4 74 143 191 194 14 280V-HEE 1198 4 42 80 14 193 19 14 200V-HEE 1221 441 90 147 180 198 1 240V-HEE 127 437 3 717 10 183 198 17 280V-HEE 122 43 34 724 187 200 17 3

DIMENSION SCHEMES FOR THE HEE VERSION LPC / ILPC with hydraulic module (mm) 70 R G G R 80 E F B 8 147 713 C D 0,m LPC / ILPC + module Dimensions (mm) A B C D E F G H A 90V-HEE 2117 1437 11100 1000 948 1200 100V-HEE 2398 1717 1393 100 1387 1000 1089 0 120V-HEE 2398 1717 1393 100 1387 1000 1089 0 10V-HEE 3113 1437 2108 100 210000 144 1200 180V-HEE 3113 1437 2108 100 210000 144 1200 H 843 200V-HEE 373 1717 28 100 2000 172 0 240V-HEE 373 1717 28 100 2000 172 0 280V-HEE 373 1717 28 100 2000 172 0 Discharge of condensates and tank drain Note: the hidraulic connections 1 2 stand out 8 mm LPC / ILPC + module Weight R R 90V-HEE 847 42 84 9 41 1 10 43 137 107 100V-HEE 913 420 29 4 4 127 41 14 12 120V-HEE 984 427 8 723 7 171 128 0 17 132 10V-HEE 138 434 72 804 7 188 124 8 197 133 180V-HEE 1381 434 7 813 77 190 12 8 199 1 200V-HEE 14 438 41 1094 104 24 1 120 270 181 240V-HEE 10 43 44 1120 21 17 124 27 182 280V-HEE 13 4 42 24 170 124 277 184 4

DIMENSION SCHEMES FOR THE HEE VERSION Independent hydraulic module (mm) 70 790 1000 Ø A 8 7 C B 843 1 1010 71 93 LPC / ILPC + module Dimensions (mm) A B C H Ø Module Connec. Ø Unit Connec. H 90V-HEE 1437 74 17 1200 1 1/4 M 1 1/4 H 100V-HEE 1717 8 17 0 1 1/4 M 1 1/4 H 120V-HEE 1717 8 17 0 1 1/2 M 1 1/2 H 10V-HEE 1437 74 17 1200 1 1/2 M 1 1/2 H 180V-HEE 1437 74 17 1200 1 1/2 M 1 1/2 H 200V-HEE 1717 8 17 0 2 M 2 H 240V-HEE 1717 8 17 0 2 M 2 H 280V-HEE 1717 8 17 0 2 M 2 H LPC / ILPC + módulo Weight LEENDA Tank drain 7 Water inlet to the tank 8 Water outlet from the tank 90V-HEE 488 448 49 242 8 3 3 8 100V-HEE 490 447 9 7 72 120V-HEE 490 4 31 74 8 83 89 10V-HEE 488 44 8 307 72 81 88 180V-HEE 488 44 8 310 73 82 89 200V-HEE 9 4 21 404 74 10 128 9 240V-HEE 9 4 21 404 74 10 128 9 280V-HEE 9 4 21 404 74 10 128 9

GRAVIMETRIC FILTERS IN THE RETURN AIR (OPTION) Air pressure drop Nominal air flow (m 3 /h) Pressure drop (mm.a.c.) 90V- 00 4,9 100V- 0,7 120V- 10000 4, 10V- 12200,8 180V- 12200,8 200V- 1000 7,4 240V- 20000 4, 280V- 24400,8 320V- 24400,8 30V- 24400,8 Nominal air flow (m 3 /h) Pressure drop (mm.a.c.) 90V-HEE 0,7 100V-HEE 10000 4, 120V-HEE 12200,8 10V-HEE 1000 7,4 180V-HEE 1000 7,4 200V-HEE 24400,8 240V-HEE 24400,8 280V-HEE 24400,8 Dimensions (mm) LPC / ILPC Frames number Frame dimensions (mm) A B C D E Distance between frames (mm) Cells number Cell thickness (mm) 90V- / 100V- 1 89 79 74 --- 2 2 818 x 48 120V- / 10V- / 180V- 1 117 94 89 --- 3 2 98 x 40 200V- 2 89 79 74 100 4 2 818 x 48 240V- / 280V- / 320V- / 30V- 17 94 89 100 2 98 x 40 Cell size (mm) LPC / ILPC Frames number Frame dimensions (mm) A B C D E Distance between frames (mm) Cells number Cell thickness (mm) 90V-HEE 1 89 79 74 --- 2 2 818 x 48 100V-HEE / 120V-HEE 1 117 94 89 --- 3 2 98 x 40 10V-HEE / 180V-HEE 2 89 79 74 100 4 2 818 x 48 200V-HEE / 240V-HEE / 280V-HEE 17 94 89 100 2 98 x 40 Filters frame is removable, and on request, can be supplied independent from LP unit for connection on site. Cell size (mm)

AIR FLEIBLE DUCTS (OPTION) Dimensions (mm) M00 asssembly M01 asssembly LP / ILP / LPC / ILPC Asssembly A B C D E 90V- / 100V- 89 127 744 120V- / 10V- / 180V- 112 470 127 894 M00 200V- 1842 378 127 1844 744 240V- / 280V- / 320V- / 30V- 2402 00 127 2404 894 90V- / 100V- 482 41 127 744 M01 120V- / 10V- / 180V- 7 13 127 894 200V- Without damper (*) 1478 41 127 1844 744 240V- / 280V- / 320V- / 30V- 1843 13 127 2404 894 90V- / 100V- 00 378 127 744 M01 120V- / 10V- / 180V- 00 00 127 894 200V- With damper (*) 0 497 127 1844 744 240V- / 280V- / 320V- / 30V- 2100 497 127 2404 894 (*) Damper for condensation pressure control. LP / ILP / LPC / ILPC Asssembly A B C D E 90V-HEE 89 127 744 100V-HEE / 120V-HEE 112 470 127 894 M00 10V-HEE / 180V-HEE 1842 378 127 1844 744 200V-HEE / 240V-HEE / 280V-HEE 2402 00 127 2404 894 90V-HEE 03 73 127 744 100V-HEE / 120V-HEE 803 83 127 894 M01 10V-HEE / 180V-HEE 100 73 127 1844 744 200V-HEE / 240V-HEE / 280V-HEE 1879 73 127 2404 894 7