CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Similar documents
The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

Andatech PRODIGY USER MANUAL

ALCOSENSE FR9000 INTERLOCK USER GUIDE/MANUAL

Breath Alcohol Tester

TABLE OF CONTENTS. Introduction

D Dräger Interlock 7000 User Guide Victoria s Alcohol Interlock Program

Breath Alcohol Tester

ELECTRICAL. Moisture Meter User Guide

Accumed BAC-178 Professional Fuel Cell Sensor Alcohol Tester

ELECTRICAL. Laser Distance Measure User Guide

WETech Active Trimmer

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

This manual covers the following model:

VERSION 2017 V.1.0

Power. On Your Terms.

10 Year Limited Warranty

User Manual SPOTTING SCOPE X 60

Motion Sensing Coach Light

AL-KO OFF-ROAD PIN COUPLING USERS MANUAL

The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

OWNER S MANUAL MiniBoost

CONTENTS. Calibration Self Check & Technical Specifications 13 Care & Maintenance, Trouble Shooting 15 Warranty 16

AL-KO OFF-ROAD BALL COUPLING USERS MANUAL

BrAC Audit Lock-1 Instruction User Manual

EAGL 1-Touch Laser Level

230VAC Power Inverter 400W Owner s Manual

ACE II Basic. Operating manual.

ROCA DUO PLUS OVAL INSET BATH

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

ALAPE METAPHOR UNDERCOUNTER BASIN

OPERATING INSTRUCTIONS FOR Ridgid 246 Pipe Cutter

DIGITAL CLICK TORQUE WRENCH

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

MODEL NUMBER: BD-132 USER GUIDE

PVI 60KW, PVI 82KW, PVI 95KW

Rig Master Power by Mobile Thermo Systems Inc.

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

MODEL NUMBER: BD-116C USER GUIDE

Digital Body Weight Scale

ROUND REMOTE BUTTONS AND PLATE (IN-WALL)

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

DIGITAL DISPLAY ALCOHOL BREATH TESTER

ROCA THE GAP BACK TO WALL TOILET SUITE

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE PRODUCT.

Series 2100 Operating Instructions

JUMP STARTER OPERATOR S MANUAL RA1900

Charging with AC (wall) Charger

AXA Cento semi wall basins with shelves

K440. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. x 1 x 1 x 4 x 1. Revision No: 10J 1

IAQ-CALC TM Indoor Air Quality Meter

OWNER S MANUAL Please read this manual before operating your power supply

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1

Compact 150 Watt Motion Sensing Halogen

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE PRODUCT.

160W Monocrystalline Folding Solar Panel USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Care and use guide. Contents. page

K682. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 8. x 4 x 2 x 2 x 4. x 4 x 4 x 4. Revision No: 1A 1

EXTRA WIDE STEEL ROLLATOR

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

CONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

AL-KO ESC USER MANUAL

Matson Jump Starter Operator s Manual

ASSEMBLY & OPERATION INSTRUCTIONS (HS-PZ002)

Series AA Roller Door

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

K681. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 2 x 2 x 2. x 2. Revision No: 4D 1

ROCA KHROMA TOILET SUITE

500kg HYDRAULIC TABLE LIFT

NEW GEN OWNER S MANUAL

Compact Solar Charger. Model Number ACSC-116 INSTRUCTION MANUAL

Euro Lightweight Wheeled Walker

Compact Solar Charger. Model Number ACSC-114 INSTRUCTION MANUAL

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

Premium Pond Pump 330 Gallons Per Hour

4. TECHNICAL SPECIFICATIONS

Owner's Manual. Rapid Charger. 4-Hour. Port USB Charger. and Portable Power Pack. for AA/AAA Ni-MH & Ni-Cd Rechargeable Batteries

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

VP Remote User s Manual (nvp)

HYDRAULIC BENCH PRESS 50,000kg

Q20. Track System. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 1. x 1 x 1 x 4 x 4. Revision No: 1A 1

BYD B-Box Limited Warranty Letter

OPERATING INSTRUCTIONS FOR Uniprep1 Tool 110mm to 400mm

Contents. Warranty Coverage... 4 Basic Vehicle Limited Warranty... 4 Supplemental Restraint System Limited Warranty... 4

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

ENTR. Smart Door Lock. Quick Start Guide. The full user manual can be found online at: anges.indd 1 16-Aug-17 18:14:5

DOMINIQUE MKII wall hung vanity 900mm. Wall Hung Vanity 900mm (Left Hand Bowl) Cabinet Only - Front View Cabint Only - Side View

250W Folding Solar Panel USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1

K500. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 4. Revision No: 14N 1

Transcription:

User Manual

Introduction CONTENTS Thank you for purchasing the AlcoSense Precision+ breathalyser. The AlcoSense Precision+ is certified to Australian Standard AS3547 Type 2 Quantitative Device and is one of the world s most advanced hand-held alcohol detectors. It uses electrochemical fuel cell sensor technology to ensure reliable and accurate information as well as a convenient mode of operation. DEVICE FEATURES...3 operating instructions...4 CONDITIONS FOR TESTING...5 warranty details...6 troubleshooting...7 disclaimers...8 specifications...8 calibration and service...9 product registration...9 2

device features DIAGRAM EXPLANATION Mouthpiece holder LCD Screen On/Off button Function button USB Port (Not used) Battery compartment cover PREPARATION Gently pull down the battery compartment cover to remove it. Insert fresh alkaline batteries (4 x AAA), checking that the + and - on each battery are aligned according to the polarity diagram inside. Carefully replace the battery compartment cover. SWITCHING THE UNIT ON AND OFF Press and hold the ON/OFF button for 2-3 seconds to switch the unit on or off. The unit will automatically switch off after 2 minutes of non-use. NUMBER OF TESTS When the unit first starts up, it will display the number of tests taken and the number of tests remaining before calibration is required. 3

OPERATING INSTRUCTIONS Normal Operation 1. Insert a disposable mouthpiece through the unit. 2. Switch on the unit. When the screen reads BLOW, take a deep breath and blow steadily into the mouthpiece for at least 4 seconds. 3. Continue blowing until the beep stops. You will hear a click. 4. Once complete, the unit displays the reading on the screen. The next test can be performed by pressing the ON/OFF button once, then repeating the previous steps. If the reading from the previous test was higher than zero, please wait 3 minutes before performing the next test to ensure accurate results. passive test 1. No mouthpieces are required for this operation. 2. When the screen reads BLOW, take a deep breath and blow gently into the hole for 3 seconds. While blowing press the ON/OFF button to record a breath sample. Once complete, you will hear a click. 3. Once complete, the unit displays the reading on the screen as No Alcohol or Alcohol Detected. 4. To conduct another test straight away, press the ON/OFF button once and repeat previous steps. 5. If a more specific reading is required, use a mouthpiece and test under normal operation. TEST RESULTS PASSIVE TEST RESULT 0.000% 4

CONDITIONS FOR TESTING Use a clean mouthpiece for each test. Do not allow samples containing smoke, tobacco or other chemical products to enter the unit, as damage to the fuel cell can occur. There must be an interval of at least 15 minutes after alcohol consumption as alcohol residue in the mouth may give a false reading. Such residue may also be left by aromatic drinks, mouthwash, medicines and drops, as well as by belching and vomiting. Rinsing your mouth with water or non-alcoholic drinks does not substitute for an interval. A person s blood alcohol concentration (BAC) can continue to rise for up to 2 hours after drinking alcohol. If a caution results or a result is close to the designated BAC, it is recommended to wait and retest after 20 minutes. It can take 10 hours or more for a person s BAC to return to zero after a high BAC has been reached. A further test should be carried out later in the day or the following morning. Working temperature range: 5 C to 40 C. Storage temperature: -15 C to 65 C. LIABILITY FOR PROPER FUNCTION OR DAMAGE The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator in the event the instrument is serviced or repaired by personnel not employed or authorised by Andatech. In such an event, the warranty will be void. 5

WARRANTY DETAILS It is our aim to provide you with quality products that you can trust. Our products come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The Guarantee The product is guaranteed to be free from defects in workmanship and parts for a period of 1 year from the date of purchase. Defects that occur within this warranty period, under normal use and care, will be repaired, replaced or refunded at our discretion, solely at our option with no charge for parts and labour. The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Trade Practices Act and similar state laws. Proof of Purchase This warranty is valid for the original purchase and is not transferable. Please keep your purchase docket or receipt as proof of purchase and as proof of date on which the purchase was made. The purchase docket (or a copy) or receipt must be presented with the warranty when making a claim under this warranty. Service during the Warranty Period To claim for warranty, contact us on 1300 800 200 or info@ andatech.com.au to get an RA# (Return Authorisation Number). Ensure that the RA# is clearly stated on the outside of the packaging and that the product is properly packaged so that no damage occurs to the product during transit. Shipping of the product back to us for warranty will be at your cost. A product return without the RA# or proof of purchase will not be accepted. Extent of Warranty This warranty is limited to defects in workmanship or parts. All defective products or parts will be repaired or replaced. This warranty does not cover manuals and packaging. 6

TROUBLESHOOTING Normal Wear and Tear This warranty does not cover normal wear and tear to the product or parts. Exclusions This warranty does not cover: Calibration costs. Any defect caused by an accident, misuse, abuse, improper operation, lack of reasonable care, unauthorised modification, loss of parts, tampering or attempted repair by a person not authorised by the distributor. Any product that has been damaged by a lightning strike either directly or indirectly or a main power surge or liquid ingress. The product if it is located outside of Australia. Any damage caused by improper power input or improper cable connection. Error "Please blow harder" Breath sample was not long, hard, or steady enough, or you did not wait for the beep to end before you stopped blowing. Blow a long, slow and steady breath. Don't stop blowing until the beep ends. 'CALIBRATION NEEDED' WARNING The unit has passed its calibration due date or has exceeded the number of allowed tests. You can press any button to continue using the unit, however we strongly recommend that you send it back to us for calibration. BATTERY LIFE TOO SHORT Use only alkaline batteries, or if using rechargeable batteries, use either NiMH or rechargheable alkaline batteries. 7

DISCLAIMERS This product must be used strictly in accordance with the instructions in this manual. This product is intended to provide the user with an indication of alcohol on the breath. However, neither the manufacturer nor the supplier gives any warranty (express or implied) that the product can give any indication of blood alcohol level. A person's BAC (Blood Alcohol Concentration) can only be accurately measured by the administration of a blood test. This product only measures breath alcohol content which, in turn, only gives an approximate indication of blood alcohol concentration. In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of their blood alcohol concentration or of their level of intoxication or of their fitness to drive and in particular should not take any action in reliance on such information as the product can provide no more than an indication of alcohol on the breath. If the user of this product makes any decision or takes any action based on the use of the product such decision or such action shall be at the sole risk of the user and neither the manufacturer nor the supplier assumes any responsibility for such decision or action. In particular, neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led them to believe that they were fit to operate a motor vehicle and are subsequently found not to be so fit. SPECIFICATIONS Indication of %BAC 0.000-0.500%BAC Accuracy ±0.005%BAC at 0.100%BAC Warm Up Time Within 3 seconds Response Time Within 3 seconds Recycle Time 5 seconds Power Supply 4 x AAA Alkaline Batteries Working Temperature -5 40 C Calibration Frequency Manufacturer recommended: Every 1000 tests or 6 months, whichever comes first. Product Weight 150g including batteries Product Dimensions 140mm (h) x 55mm (w) x 30mm (d) 8

CALIBRATION AND SERVICE Andatech recommends the AlcoSense Precision+ to be calibrated every 6 months or after 1000 uses. PRODUCT REGISTRATION my.andatech.com.au is a central location where you can register your warranty, sign up to recieve calibration reminders and book in calibrations. Once you have registered, you can add as many AlcoSense products as needed to that account. Register online at my.andatech.com.au product registration Visit my.andatech.com.au to register your warranty online and receive calibration reminders. Alternatively, complete this form and forward to the address below with a copy of your proof of purchase. Andatech Corporation Pty Ltd PO BOX 3038, Nunawading VIC 3131 Australia. Product Date of purchase Place of purchase Surname Given name Address Suburb AlcoSense Precision+ Postcode State Contact no. Email 9

Calibration Centre Andatech Corporation Pty Ltd PO Box 3038 Nunawading VIC 3131 1300 800 200 www.andatech.com.au Version 2.0. Updated 04.06.2014