Marine Catalogue 2014

Similar documents
ROUND DUCTING » PRODUCT CATALOGUE AIR COMFORT AIR DISTRIBUTION

Regulation and shut-off damper SPB and SPC

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

OPTIVENT Housing HVSA, HVSL

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

ACTIVENT System. Specifications. Product code example ACTA

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC

ACCESSORIES FOR DUCT FANS

Mechanical mixing box MBM

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Slot diffusers, Round duct diffusers. IMP Klima

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CTVK Supply air diffuser

ROOFMASTER STEF-ATEX ROOF FAN

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Pressure control damper ERPA

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

IrisControlDamper. For Adjustment and Measuring of Airflow.

VARYCONTROL VAV Dual Duct Terminal Boxes

Kitchen exhaust fan GLEB

KSOF Fire damper valve

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Fan - Powered Terminal Unit Series Flow

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

CONSTANTFLOW Volume Flow Controllers

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Flexible Ducts. Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie

Nozzle air diffuser DYSB

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Ceiling swirl diffusers

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

ceiling swirl diffuser DQJ

Technical documentation

ROOFMASTER STEF-HT ROOF FAN

Exhaust air diffuser HPKH + Plenum box ATTS

Combustion gas damper EKO-SRB

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

Fire/combustion gas damper EKO-JBL

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Fire dampers ETCE and ETCS TECHNICAL DATA

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

SINGLE DUCT TERMINAL UNITS

Ceiling swirl diffusers with perforated face plate

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

WGA Long throw nozzle grille

ROOFMASTER STEF ROOF FAN

Conical diffuser KHAA TECHNICAL DATA

Round duct grille Model KG-RR

Volume Flow Limiters Type VFL

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Fire/combustion gas damper EKO-JBG

series RVV Variable flow rate controllers

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

ceiling swirl diffuser Model DQJA / DQJR

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

REK, LEK, ROK and LOK

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

Parts and characteristics

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

ESAS Smoke control damper

Ceiling Swirl Diffuser DQJ

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

VAV controller. TROX Auranor Norge AS. Telephone Fax

HOTCHKISS AIR ACOUSTICS

Zest Iris Duct Dampers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Slot diffusers for ceiling installation

Transcription:

Photo copyright STX Finland Marine Catalogue Marine Catalogue 14 1 05.08.14 Fläkt Woods EN 14.05 All rights reserved.

www.flaktwoods.com

Marine Catalogue Content 3 Components Type BDE Uninsulated Type BDA Insulated Joint Designation Page Joint Designation Page Spiral tube F 1) BDEK 11 F 1) BDPK 2) BDPR 2) 19 Joint for joining duct fittings F BDEM 11 F BDAM 19 Insertion joint for joining ducts I 1) BDEN 11 I 1) BDAN 19 Bend I BDEB 12 I BDAB 22 Reducer F/I 3) I/I 5) BDED-1 BDED-3 12 F/I 3) I/I 5) BDAD-1 BDAD- BDAD-3 BDAD- 21 T-piece I BDET 13 I BDAT 23 Cross I BDEX 13 Branch I BDEA 12-13 I BDAA 21 Lid for fittings with insertion dimensions Lid for tube F I BDEG-1 BDEG-4 13 BDAG- BDAG- 24 Flexible tube F BDES 11 F BDPS 22 Penetration piece for passage through the deck or bulkhead F BDGG 25 F BDPG BDGG 4) 25 Tubular shell BDPC 24 BDPC 24 Clip for suspending ducts BDSK 24 BDSK 24 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Content 4 Type BDE Uninsulated Type BDA Insulated Joint Designation Page Joint Designation Page Non-return damper I BDGP-2 6) 44 I BDGP-2 44 Damper, adjustment and shut-off I BDEP 45 I BDAP 45 Joint Designation Page Sound absorber I BDER 43 Damper regulation and measuring I IRIS IRIS-H 52 Damper, regulation and shut-off SPB SPC 53 Plenum box ATTC 61 Ceiling diffusers RMKO RMKP 64 Ceiling diffusers RMRO RMRP 70 1) F = fit-on dimension I = insertion dimension 2) BDPK heat-insulated BDPR heat and sound insulated and with the inner duct wall perforated for sound absorption. 3) Fit-on dimension in one end and insertion dimension in the other. 4) Non-insulated. 5) Insertion dimension in both ends. 6) Insulated. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Content 5 Joint Designation Page Ceiling diffuser CTPB 76 Air diffuser CTUR 81 Air supply unit MCSA 86 Air supply unit MCDA 93 Exhaust valve KGEB 0 Grille SV2 4 Grille USR 8 External louvre RIS 112 Fläkt Woods EN 14.05 All rights reserved.

Veloduct reduces operating costs, simplifies adjustments, permits rapid, easy and clean installation and can be installed in any climate. All duct fittings are equipped with a sealing ring, made of EPDM rubber. www.flaktwoods.com

Marine Catalogue MINIDUCT Circular ducting 7 Duct components for marine applications are available for the following types of ventilation ducts to the international size standard (European Standard EN16). Type BDE Uninsulated spiral tubes and fittings, sizes 008 063, see pages 6-11. Type BDA Spiral tubes and fittings, with thermal insulation or thermal and sound insulation, sizes 0 031 (80 2 mm nominal diameter of inner tube) see pages 12-23. Duct components of different types can also be combined as shown in the installation examples. In the MINIDUCT system, components with insertion sizes are provided with factory-fitted double rubber seals, thus ensuring tight and strong ducts which can be assembled very quickly. Materials and finish Uninsulated components: Made of galvanised sheet steel. Airinsulated components: Made of galvanised sheet steel. Insulated tubes: Made of galvanised sheet steel with glass wool insulation. Steel tube components (BDGG, and BDPG): Weldable steel. Dimensions All dimensions in this catalogue section are given in mm, unless otherwise stated. Weights See pages -11 and 21-23. Pressure drop See pages 24-29. Tightness The ducts and fittings are manufactured to tightness class C of the Eurovent standard 2/2, when assembled in accordance with installation and assembly instructions. Instructions Installation and assembly instructions can be requisitioned from Fläkt Woods Oy. Fig. 1. Type BDE uninsulated spiral tubes. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 8 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Content 9 Components Type BDE Uninsulated Joint Designation Page Spiral tube F 1) BDEK 11 Joint for joining duct fittings F BDEM 11 Insertion joint for joining ducts I 1) BDEN 11 Bend I BDEB 12 Reducer F/I 3) I/I 5) BDED-1 BDED-3 12 T-piece I BDET 13 Cross I BDEX 13 Branch I BDEA 12-13 Lid for fittings with insertion dimensions Lid for tube F I BDEG-1 BDEG-4 13 Flexible tube F BDES 11 Penetration piece for passage through the deck or bulkhead F BDGG 25 Tubular shell BDPC 24 Clip for suspending ducts BDSK 24 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting Type BDE uninsulated ducting components Uninsulated Design A complete duct is assembled from BDEK spiral tubes and a number of duct fittings for jointing, branching-off, etc. Jointing takes place by the tubes and certain other components with fit-on ends being fitted with other jointing components with insertion ends. Insertion components are provided with factory-fitted seals of non-ageing EPDM rubber. The grade of rubber used for seals is characterized by excellent resistance against ozone and ultraviolet light. This grade of rubber is generally used when strict demands are made on good ageing and settlement properties. The seals are reliably secured to the ends of the duct components and eliminate entirely all manual sealing procedures in the assembly of duct components. The fit-on and insertion components are locked to each other by means of self-tapping screws or pop rivets. The principle of sealing is illustrated in Fig. 3 and 4, which show an insertion component and a fit-on component (tube) before and after assembly. The joints can withstand a pressure of 3 kpa, without the seal being impaired. Vacuum in the duct improves sealing. Before assembly Fig. 3 Fit-on tube After assembly Insertion component Seal Self-tapping screw or pop rivet Sizes The size designation specifies the diameter of the tube or tube fitting in cm. In the case of T-pieces, crosses and transition pieces, the size designation consists of two part designations (see the corresponding duct components). Fig. 4 *) The insertion or fit-on dimension L and the tolerances on D and d are specified in the table below (dimension D max D min or d max d min). Pressure drop See charts on pages 24 29. Dimensions and tolerances according to European standard EN16 General dimensions and weights (see also Fig. 3 and 4) Size designation 008 0 012 016 0 025 031 0 0 063 Dimensions, mm: Tube D max 80.5 0.5 125.5 160.6 0.7 2.8 315.9 1.0 1.1 631.2 D min (nom. dia.) 80.0 0.0 125.0 160.0 0.0 2.0 315.0 0.0 0.0 6.0 Fitting d max 79.3 99.3 124.3 159.3 199.3 249.3 314.3 399.3 499.3 629.3 d min 78.8 98.8 123.8 158.7 198.6 248.5 313.4 398.3 498.2 628.1 Insertion length L i Tolerance +0/-5 35 35 35 35 35 60 60 60 Fit-on length L p Weights: kg/m, Tube 1.2 1.3 1.7 2.1 2.7 3.2 3.9 7.7 9.7 12.2 Weights See pages 11. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting Type BDE range, dimensions 11 The range is indicated by the shaded areas. bbb and ccc indicate the size as well as the dimensions (cm). Other dimensions in mm. Insertion connections are marked, and fit-on connections are marked. The dimensions for insertion and fit-on lengths are common, and are shown for the BDEN joint and the BDEM joint. Tube, type BDEK -a -bbb* t bbb Main tube, code suffix bbb 008 0 012 016 0 025 031 0 0 063 Code suffix a indicates the tube length: 3.00 m (a = 3), 6.00 m (a = 6), random length (a = 4), although 6 m max. Nom. dia., mm 80 0 125 160 0 2 315 0 0 6 Wall thickness t, mm 0.5 0.7 *) In the case of code suffix a = 4, specify the total length in m (to 2 decimals) the number of tubes and the cut lengths in cm (although 600 cm max.) Example: 24.32 m of BDEK-4-0215 tube, 8 tubes of 4 cm each. Tolerance of length ± 0 mm. Uninsulated Height of spiral joint ~3 mm Flexible tube, BDES-6-bbb Clip, type BDEZ-01-bbb Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 Tube length bbb Joint, type BDEM-1-bbb compressed: expanded: 0,15 m 6,00 m bbb Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 L p 35 45 75 L 12 L 12 L p Insertion joint, type BDEN-1-bbb bbb L i L Max. 8 Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 L I 35 60 L 5 5 5 5 5 5 5 25 25 25 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting 12 Type BDE range, dimensions For explanatory text to the table, see page 7. Uninsulated Bend, type BDEB-aa-bbb aa = angle as tubulated below (90, 45, or 15) 45, and 15 bends Sizes 008 0 Sizes 025 063 Main tube, code suffix bbb L 2 L 2 bbb 008 0 012 016 0 025 031 0 0 063 L1 90 0 0 125 160 0 2 315 0 0 6 L 2 L 2 L2 45 65 80 0 1 165 5 260 L2 25 70 85 1 124 156 R R L2 15 15 15 15 15 15 56 59 R 90 0 0 125 160 0 2 315 0 0 6 90 bend R 45 0 0 125 160 0 2 315 0 0 6 Sizes 008 0 Sizes 025 063 R 0 0 125 160 0 2 315 0 0 6 L 1 L 1 R 15 0 0 125 160 0 2 315 0 6 bbb L 1 L 1 R R Concentric reducer, type BDED-a-bbb-ccc a: 1 and 3 Eccentric reducer, type BDKF-a-bbb-ccc a: 2 and 4 a = 1, bbb = 0 0 a = 2, bbb = 0 063 bbb bbb L p L ccc bbb E ccc bbb E L ccc a = 3, bbb = 0 0 a = 4, bbb = 0 063 ccc Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 BDKF ccc BDED Concentric design a =1 and 3 Eccentric design a = 2 and 4 008 25 15 70 0 22 42 70 25 49 70 Dimension 012 28 54 80 E 33 55 80 016 35 59 98 35 59 97 0 45 75 115 35 78 1 43 90 025 125 Dimension L 43 70 60 031 Upper figure denotes a = 1 92 157 Lower figure denotes a = 3 0 115 0 65 L for BDKF 2 315 Branch, type BDEA-1-bbb-ccc bbb For use on round ducts L L ccc L1 Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 008 43 45 45 45 45 45 0 55 55 55 55 55 60 60 60 012 55 55 55 55 55 55 55 55 016 60 60 65 60 60 60 60 0 65 65 65 70 70 70 025 Dimension 70 70 70 70 70 031 L1 75 75 75 75 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting Type BDE range, dimensions 13 For explanatory text to the table, see page 7. Branch, type BDEA-5-bbb L 2 Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 L2 60 70 70 Lid, type BDEG-1-bbb bbb Uninsulated bbb L Used to blank off duct components with insertion dimensions. Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 L 41 41 41 41 5 5 5 Lid, type BDEG-4-bbb L bbb Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 L 17 22 25 T-piece, type BDET-a-bbb-ccc Cross, type BDEX-a-bbb-ccc L3 bbb ccc L 1 L 2 T-pieces and crosses with code suffixes bbb = 008 to 063 (all sizes) are available only in concentric versions. a = = 1 1 concentric bbb = 008 063 Branch size, code suffix ccc Concentric version, code suffix a = 1 Sizes 008 0 without a stop ring, sizes 025 up to 063 with a stop ring Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 008 L1 75 73 73 73 73 68 L3 45 45 45 45 45 0 L1 83 83 90 90 85 90 0 90 95 L3 * 33* 55 55 55 55 012 L1 96 3 0 95 95 115 1 1 L3 33* 55 55 55 55 45 45 45 016 L1 125 125 133 1 1 1 1 L3 60 60 65 60 55 55 55 0 L1 155 1 1 1 145 1 L3 65 65 65 65 65 65 025 L1 185 185 180 170 175 BDET 1 L2 031 L1 2 2 225 225 L2 35 35 35 35 0 L1 0 0 0 L2 0 0 0 0 L1 BDEX 1 3 3 L2 1 1 063 L1 4 L2 1 *= L2 size Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting 14 Type BDE range, weights Weights: [kg] Uninsulated Main tube, code suffix bbb 008 0 012 016 0 025 031 0 0 063 Tube BDEK weight/meter 1,2 1,3 1,7 2,1 2,7 3,2 3,9 7,7 9,7 12,2 Flexible Tube BDES weight/meter 0,15 0,17 0,2 0,27 0,39 Joint BDEM -1 weight/pc 0,06 0,08 0,1 0,12 0,16 0,26 0,34 0,84 1,08 1,34 Insertion Joint BDEN -1 weight/pc 0,08 0,1 0,12 0,14 0,18 0,34 0,42 1,24 1,24 1,58 Lid BDEG -1 weight/pc 0,08 0,1 0,12 0,18 0,28 0,46 0,66 1,28 1,84 2,66 Lid BDEG -4 weight/pc 0,12 0,14 0,16 0,26 0,32 0,56 0,76 1,34 1,9 2,7 Bend 90 BDEB -90 weight/pc 0,26 0,3 0,5 0,9 1,32 1,56 2,3 5,5 8,12 12,3 Bend 45 BDEB -45 weight/pc 0,22 0,24 0,34 0,56 0,82 1,06 1,38 3,3 4,74 6,9 Bend BDEB - weight/pc 0,18 0,2 0,26 0,48 0,56 0,74 1,02 2,46 3,5 5,08 Bend 15 BDEB -15 weight/pc 0,12 0,16 0,18 0,32 0,4 0,6 0,86 1,8 2,4 3,4 Branch BDEA -5 weight/pc 0,08 0,14 0,18 0,28 0,36 0,52 0,68 0,96 1,2 1,5 Main tube, code suffix bbb Branch BDEA-1-bbb-ccc Weight/pc ccc 008 0 012 016 0 025 031 0 0 063 008 0,1 0,1 0,1 0,1 0,1 0,08 0 0,18 0,14 0,14 0,18 0,16 0,14 0,14 0,14 0,14 012 0,22 0,22 0,22 0,22 0,2 0,2 0,2 0,2 016 0,38 0,36 0,34 0,32 0,28 0,3 0,3 0 0,56 0,44 0,42 0,42 0,42 0,42 025 0,78 0,7 0,64 0,6 0,58 031 0,92 0,88 0,84 0,78 Main tube, code suffix bbb Reducer BDED-1-bbb-ccc Weight/pc ccc 008 0 012 016 0 025 031 0 0 063 008 0,16 0,18 0,26 0 0,18 0,28 0,42 012 0,28 0,36 0,6 016 0,38 1,58 0,94 BDKF-2 0 0,5 0,8 1,54 025 0,72 1,34 2,8 031 1,2 2,96 4,18 0 3,48 4,64 0 4,7 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated Miniduct circular ducting Type BDE range, weights 15 Weights: [kg] Main tube, code suffix bbb Reducer BDED-3-bbb-ccc Weight/pc ccc 008 0 012 016 0 025 031 0 0 063 008 0,16 0,18 0,26 0 0,18 0,28 0,42 012 0,28 0,34 0,58 016 0,36 1,56 0,92 BDKF-4 0 0,46 0,76 1,48 025 0,68 1,28 2,8 031 1,16 2,96 4,1 0 3,4 4,52 0 4,58 Uninsulated Main tube, code suffix bbb T-Piece BDET-1-bbb-ccc Weight/pc ccc 008 0 012 016 0 025 031 0 0 063 008 0,28 0,41 0,55 0,65 0,75 0,90 0 0,48 0,66 0,72 0,84 1,01 1,23 2,76 3,33 4,07 012 0,68 0,81 0,94 1,14 1,38 2,91 3,51 4,31 016 1,06 1,16 1,42 1,66 3,25 3,96 4,86 0 1,46 1,77 2,08 3,65 4,44 5,42 025 2,23 2,58 4, 5,33 6,53 031 2,86 4,91 5,93 7,25 0 5, 6, 8,90 0 8,60,0 063 12,0 Main tube, code suffix bbb Weight/pc ccc 008 0 012 016 0 025 031 0 0 063 008 0, 0, 0,71 0,81 0,88 1,00 0 0,63 0,75 0,86 0,95 1, 1, 3, 3,80 4, 012 0,93 0,98 1, 1, 1,70 3, 3,90 4,60 016 1, 1, 1,70 1,90 3,60 4, 5, 0 1,70 2, 2, 3,70 4,70 5,80 025 2,70 2,90 4, 5,70 6,90 031 3, 5, 6, 7, 0 6, 7, 9, 0 9, 11,0 063 13,0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 16 Components Type BDA Insulated Content Joint Designation Page Spiral tube F 1) BDPK 2) BDPR 2) 19 Joint for joining duct fittings F BDAM 19 Insertion joint for joining ducts I 1) BDAN 19 Bend I BDAB 22 Insulated Reducer F/I 3) I/I 5) BDAD-1 BDAD- BDAD-3 BDAD- T-piece I BDAT 23 21 Cross Branch I BDAA 21 Lid for fittings with insertion dimensions Lid for tube BDAG- BDAG- 24 Flexible tube F BDPS 22 Penetration piece for passage through the deck or bulkhead F BDPG BDGG 4) 25 Tubular shell BDPC 24 Clip for suspending ducts BDSK 24 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P), insulated ducting components 17 Design A complete duct consists of type BDPK (heat insulated) or type BDPR (heat and sound insulated) spiral tubes and fittings for jointing, branching-off, etc. Type BDPK and BDPR tubes consist of an outer tube and an inner tube with intervening glass wool insulation (non combustible). The thickness of insulation depends on sizes of outer and inner tubes. There is two ranges of sizes: recommended sizes, which have thicker insulation and additional sizes, which have thinner insulation. Look at sizes and diameters beneath. Good sound absorbtion (on the type BDPR) is obtained by the inner tube being perforated. Duct fittings are of double -wall design with intervening air insulation and with double sealing (sealing on both outer and inner tube). In other respects, the particulars are the same as for type BDE duct components. Sizes Recommended sizes: 0, 012, 016, 0, 025, 031. Both outer and inner diameters are according to European standard EN 16. We recommend these sizes. Additional sizes (outer/inner): 015/012, 016/014, 018/016, 0/018, 022/0, 022/018, 025/022, 028/025, 031/028. The size designation specifies the diameter of the outside tube in cm. The inner tube is one size smaller concerning recommended sizes (EN 16). Fig. 5 When choosing additional sizes look at diameters and extra designations in chapter C. Sizes and Codes, in the table, on page 13. In case of T-pieces and reducers, the size designation consists of two sub-designation (see the relevant duct fitting) Pressure drops The pressure drops across BDA-fittings are the same as those across the BDE-fitting with the diameter of inner tube, see pages 24-29. Insulated Sealing principle Insertion fitting to duct, sizes 0 031 Fig. 6. Before assembly Fig. 7. After assembly *) Insertion dimension/fit-on dimension L and the tolerances on D and d are specified in the table below (dimensions D max D min and d max d min). Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 18 Type BD(A,P), insulated ducting components General dimensions A. Recommended range of sizes: Size To European standard EN16 0 012 016 0 025 031 Dimensions, mm Tube, D max 0.5 125.5 160.6 0.7 2.8 315.9 D min (nom. dia.) 0.0 125.0 160.0 0.0 2.0 315.0 Fitting, d max 99.3 124.3 159.3 199.3 249.3 314.3 d min 98.8 123.8 158.7 198.6 248.5 313.4 Insertion/fit-on length, L +0 / --5 Inner tube (nom. dia.) 80 0 125 160 0 2 Weights: kg/m, Tube 2.5 3.2 4.1 5.2 6.3 8.2 Insulated B. Additional range of sizes: Size To European standar EN16 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 Tube, D max 1,6 160,6 180,7 0,7 224,8 224,8 2,8 280,9 315,9 D min (nom. dia.) 1,0 160,0 180,0 0,0 224,0 224,0 2,0 280,0 315,0 Fitting, d max 149,3 159,3 179,3 199,3 223,3 223,3 249,3 279,3 314,3 d min 148,7 158,7 178,6 198,6 222,5 222,5 248,5 278,4 313,4 Insertion/fit-on length, L +0 / --5 Inner tube (nom. dia.) 125 1 160 180 0 180 224 2 280 Weights: kg/m, Tube 4,0 3,9 4,6 5,3 6,1 6,0 6,4 7,3 8,4 C. Sizes and codes Main Tube, code suffix bbb / diam. of inner tube Branch, code suffix ccc / diam. of innertube Minor end, code suffix ccc / diam. of innertube Second end of main tube / diam. of innertube 0/ 012/ 015/ 016/ 016/ 018/ 0/ 0/ 022/ 022/ 025/ 025/ 028/ 031/ 031/ 008 0 012 012 014 016 016 018 0 018 0 022 025 025 028 0/008-1 -2-1 -1-1 -2-1 -1-1 012/0-1 -2-1 -1-1 -2-1 -1-1 015/012-1 -1-2 -1-1 -2-1 -2-1 -2-1 -1-2 016/012-3 -1-1 -1-2 -1-1 -2 016/014-2 -4-2 -2-4 -3-4 -2-4 -2-3 -4 018/016-1 -1-2 -1-2 -1-2 -1-1 -2 0/016-3 -1-3 -3-1 -3 0/018-2 -4-2 -4-2 -4-2 -2-4 022/0-1 -3-1 -3-1 -1-3 022/018-2 -4-2 -4-2 -2-4 Recommended range of sizes, white cells 025/0 Additional range of sizes, cells with codes -c or -d = -1, -2, -3 or -4-3 -1-3 025/022-2 -4-2 -2-4 028/025-1 -1-2 031/025-3 031/028-2 -4 Table: Extra code suffix (-c, -d) for additional range of sizes Codes: example Recommended range of sizes BDAN - a - bbb BDAT - a - bbb - ccc Additional range of sizes BDAN - a - bbb - c BDAT - a - bbb - ccc - d (-c, look at the table) (-d, look at the table) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, dimensions 19 The range is indicated by the shaded areas. bbb and ccc indicate the size as well as the dimensions (cm). Other dimensions in mm. Insertion connections are marked, and fit-on connections are marked. The dimensions for insertion and fit-on lengths are shown in the table on page 12. Tube, type BDPK-3-bbb (-c)(heat insulated) Tube, type BDPR-3-bbb (-c) (heat and sound insulated and with the inner duct wall perforated for sound absorption.) BDPK BDPR Main tube, code suffix bbb Recommended sizes 0 012 016 0 025 031 Outer tube, nom. diameter 0 125 160 0 2 315 Inner tube 80 0 125 160 0 2 Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 Outer tube, nom. diameter 1 160 180 0 224 224 2 280 Inner tube 125 1 160 180 0 180 224 2 Joint, type BDAM-1-bbb (-c) bbb Lp Main tube, code suffix bbb Recommended 008 0 012 016 0 025 031 sizes L p 35 45 Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 L p 35 45 Insulated Insertion joint, BDAN-1-bbb (-c) bbb Main tube, code suffix bbb Recommended sizes 008 0 012 016 0 025 031 L i 35 L 5 5 5 5 5 5 5 L Li Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 L i 35 L 5 5 5 5 5 5 5 5 5 Insertion joint, BDAN-4-bbb (-c) Main tube, code suffix bbb Recommended sizes 008 0 012 016 0 025 031 L i 35 45 L 265 bbb Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 L i 35 L 260 Li L Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, dimensions Reducer, type BDAD-1-bbb-ccc (-d) and type BDAD--bbb-ccc (-d) bbb = 012 031 BDAD-1 L BDAD- L1 bbb ccc bbb ccc Application: The small end is connected to a BDPK or BDPR tube and the large end to a duct fitting with a fit-on dimension such as the BDAT T-piece. Application: The both ends are connected to a BDPK or BDPR tube. Insulated Recommended sizes Code suffix ccc Main tube, code suffix bbb 012 016 0 025 031 0 67/25 80/49 012 67/33 85/55 016 75/35 0/59 0 75/35 1/78 Dimension L/L1 025 81/43 Main tube, code suffix bbb / inner diameter Additional sizes Code suffix ccc / Inner diameter 015/012 016/014 018/016 0/018 022/0 022/018 025/022 028/025 031/028 0/ 008 1 / 80 / 45 012/ 0 1 / 67 / 2 / 75 / 015/ 012 2 / 65 / 15 1 / 65 / 016/ 012 1 / 66 / 25 1 / 75 / 34 016/ 014 2 / 60 / 15 4 / 25 / 34 018/ 016 1 / 60 / 25 1 / 75 / 35 2 / 60 / 35 0/ 016 1 / 80 / 25 3 / 60 / 25 3 / 85 / 35 0/ 018 2 / 70 / 22 4 / 70 / 25 4 / 80 / 35 022/ 0 3 / 70 / 022/ 018 4 / 80 / Code suffix -d / L / L1 025/ 0 025/ 022 028/ 025 031/ 025 031/ 028 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, dimensions 21 Penetration reducer, type BDAD-3-bbb-ccc (-d) and type BDAD--bbb-ccc (-d) bbb = 012 031 BDAD-3 bbb L ccc Main tube, code suffix bbb Recommended sizes 012 016 0 025 031 Diam. ccc 0 67 /25 012 75 / 33 016 75 /35 0 Dimension L/L1 82 / 35 025 81/45 Application: For connection of BDAB and BDAT insulated fittings to BDGG-1. BDAD- Main tube, code suffix bbb -d Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 Diam. ccc 012 75/ 014 65/ 016 60/25 018 70/25 0 70/25 018 Dimensions L / L1 80/ 022 80/ Insulated Application: For connection of BDPK or BDPR to BDGG-1. Branch, BDAA -5 -bbb (-c) L 2 bbb Main tube, code suffix bbb Recommended sizes 0 012 016 0 025 031 L 2 Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 L 2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 22 Type BD(A,P) range, dimensions For explanatory text to the table, see page 13. Preinsulated, flexible tube, type BDPS-3-bbb *) Main tube, code suffix bbb 0 012 016 0 025 031 Ds / Du 2/152 127/178 160/229 3/254 254/318 *) Note! Main tube bbb here denotes inner diameter, opposite of the other Miniduct fittings. ** Clip, type BDEZ-01-bbb, see page 7. **) bbb according to Ds if not otherwise ordered. Du Ds bbb = Ds Tube length: compressed: expanded: Tube material: Insulation: 3 mm 0 mm wire reinforced, plastic coated glass fibre fabric Mineral wool Insulated Bend, type BDAB-aa-bbb (-c) aa = angle as tubulated below (90, 45, or 15) 90 bend Sizes 0 0 Sizes 025 031 L 1 L 1 bbb L 1 L 1 R R 45, and 15 bends Sizes 0 0 Sizes 025 031 L 2 L 2 L 2 R R L 2 Main tube, code suffix bbb Recommended sizes 008 0 012 016 0 025 031 L 1, 90 0 0 125 160 0 2 315 L 2, 45 65 80 0 1 L 2, 25 25 70 85 L 2, 15 15 15 15 15 15 60 R, 90 0 0 125 160 0 2 315 R, 45 0 0 125 160 0 2 315 R, 0 0 125 160 0 2 315 R, 15 0 0 125 160 0 2 315 Main tube, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 L1, 90 1 160 180 0 224 224 2 280 315 L2, 45 57 65 80 83 80 80 5 7 1 L2, 70 72 85 L2, 15 13 13 13 32 37 42 R, 90 1 160 180 0 224 224 2 280 315 R, 45 1 160 180 0 224 224 2 280 315 R, 1 160 180 0 224 224 2 280 315 R, 15 1 160 180 0 224 224 2 280 315 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, dimensions 23 For explanatory text to the table, see page 13. T-piece, type BDAT-1-bbb-ccc (-d) bbb = 012 031 L 1 Main tube, code suffix bbb Recommended sizes 0 012 016 0 025 031 Code suffix ccc 0 L 1 90 90 90 90 L 3 55 55 55 012 L 1 0 0 0 L 3 55 55 55 016 L 1 125 125 1 L 3 60 60 65 0 L 1 153 148 148 L 3 65 65 65 025 L 1 185 185 L 3 70 70 031 L 1 0 L 3 75 bbb L 2 L 3 ccc Sizes 008-0 outer diameter without a stop ring, sizes 025-031 outer diameter with a stop ring. Main tube, code suffix bbb / inner diameter Additional sizes 015/ 012 016/ 014 018/ 016 0/ 018 022/ 0 022/ 018 025/ 022 028/ 025 031/ 028 Code suffix ccc / inner diameter 0/ 008 L1/ -d 90/ -1 90/ -2 90/ -1 L2 1 4 115 012/ 0 L1/ -d 0/ -1 0/ -2 0/ -1 L2 96 0 1 015/ 012 L1/ -d 125/ -1 125/ -2 125/ -1 L2 1 115 125 016/ 012 L1/ -d 125/ -3 127,5/ -1 125/ -1 125/ -1 125/ -2 125/ -1 L2 5 115 125 137 137 1 016/ 014 L1/ -d 125/ -4 125/ -2 125/ -4 125/ -3 125/ -4 125/ -4 L2 5 115 125 137 137 1 018/ 016 L1/ -d 155/ -1 153/ -2 154/ -1 153/ -2 153/ -2 L2 115 1 142 142 155 0/ 016 L1/ -d 153/ -3 153/ -1 153/ -3 153/ -3 153/ -1 153/ -3 L2 135 147 152 160 175 193 0/ 018 L1/ -d 153/ -4 153/ -2 153/ -4 153/ -4 153/ -2 153/ -4 L2 135 147 147 160 175 193 022/ 0 L1/ -d 191/ -1-190/ -3 190/ -1 190/ -3 L2-155 180 187 022/ 018 L1/ -d 190/ -2 190/ -4 190/ -4 190/ -2 190/ -4 L2 1 155 180 187 025/ 0 L1/ -d 190/ -3 190/ -1 190/ -3 L2 160 175 193 025/ 022 L1/ -d 190/ -4 190/ -2 190/ -4 L2 160 175 193 028/ 025 L1/ -d 215/ -1 215/ -2 L2 180 183 031/ 025 L1/ -d 2/ -3 L2 198 031/ 028 L1/ -d 2/ -4 L2 198 Insulated Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 24 Type BD(A,P) range, dimensions Lid, type BDAG--bbb (-c) bbb =0-031 L bbb Main tube, code suffix bbb Recommended sizes 0 012 016 0 025 031 L 45 55 Additional sizes Main tube, code suffix bbb -c 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 L 45 37 45 37 45 55 031-4 Lid, type BDAG--bbb (-c) Insulated bbb = 012 031 Tubular shell, type BDPC-1-bbb L bbb Main tube, code suffix bbb Recommended sizes 0 012 016 0 025 031 L 70 77 Additional sizes Main tube, code suffix bbb -c 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 L 70 70 76 70 76 70 77 031-4 Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 D 0 125 160 0 2 315 for joining in cases where the insertion method cannot be used, e.g. when axial insertion is impossible or when a separable joint is desired. Clip, type BDSK-bbb for suspending ducts Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 D 83 3 128 163 3 2 314 Max. 600 Max. 2800 for uninsulated duct Max. 00 for insulated duct Pendants made of flat bar steel are welded to the deck or to beams. Every second or every third pendant is V-shaped to prevent the duct from swaying. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, dimensions 25 For explanatory text to the table, see page 13. Penetration piece, type SD-1-bbb-ccc for passage through deck or bulkhead, where insulation from the deck or bulkhead is not necessary. bbb (ccc) L D Recommended sizes Code suffix L ccc 0 0 2 025 900 090 1800 180 Main tube, code suffix bbb 008 0 012 016 0 025 031 D 89 8 133 168 6 256 Additional sizes: Please ask for an offer BDA components BDE components BDEK tube BDEN insertion joint BDGG penetration piece Bulkhead or deck BDPK tube BDAD- reducer BDGG penetration piece Bulkhead or deck BDAD-3 BDAB BDEB Insulated Penetration piece, type BDPG-1-bbb-c for passage through the deck or bulkhead. Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 D 6 131 166 6 2 bbb D bbb = 0, 012, 016, 0 c = 1 (Heat insulated) 2 bbb = 0 c = 2 (A<0cm2) 160 168 BDPG-1-0-2 BDAB-90-0 BDAD--0 BDAD-3-0 BDPK-3-0 Note. No special fire preventive measures are necessary, since the internal tube area is less than 0 cm 2 A<0cm 2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 26 Type BD(A,P) range, weights Weights: [kg] Recommended sizes Insulated Main tube*, code suffix bbb 0 012 016 0 025 031 Tube BDPK -3 weight/meter 2,47 3,17 4,07 5,17 6,17 8, Tube, sound insulated BDPR -3 weight/meter 2, 2,80 3, 4, 5, 7, Flexible Tube BDPS -3 weight/meter 0,35 0,38 0,48 0,68 Joint BDAM -1 weight/pc 0,16 0,2 0,28 0,38 0,54 0,65 Insertion joint BDAN -1 weight/pc 0,18 0,26 0,32 0,42 0,58 0,90 Insertion joint, long BDAN -4 weight/pc 0,74 0,92 1,16 1,47 1,86 2,36 Lid BDAG - weight/pc 0,18 0,22 0, 0,46 0,74 1,12 Lid BDAG - weight/pc 0,26 0, 0,42 0,58 0,88 1,32 Bend 90 BDAB -90 weight/pc 0,60 0,90 1,55 2, 2,73 4,27 Bend 45 BDAB -45 weight/pc 0,45 0,60 1,00 1, 1,92 2,65 Bend BDAB - weight/pc 0,27 0,55 0,80 0,95 1,34 1,95 Bend 15 BDAB -15 weight/pc 0,28 0,33 0, 0,70 1,00 1,46 Penetration reducer BDAD -3 weight/pc 0,26 0,4 0,52 0,72 0,71 0,97 Penetration reducer BDAD - weight/pc 0,28 0,42 0,54 0,74 0,85 1,15 Tubular shell BDPC -1 weight/pc 0,2 0,22 0,3 0,34 Clip BDSK weight/pc 0,06 0,1 0,16 0,18 0,28 0,36 Penetration BDPG -1 -bbb -1 weight/pc 2,3 2,9 3,7 4,8 Penetration BDPG -1 -bbb -2 weight/pc 3,5 Branch BDAA -5 weight/pc 0,26 0,35 0,47 0,62 0,85 1,21 Main tube*, code suffix bbb Penetration BDGG -1 -bbb -ccc weight/pc ccc L 080 0 012 016 0 025 031 0 0 1,2 1,5 1,9 2,4 3,0 025 2 1,5 1,9 2,4 3,0 3,8 090 900 6,8 8,5,9 13,6 17 180 1800 14 17 22 27 34 Main tube*, code suffix bbb Reducer BDAD -1 -bbb -ccc weight/pc ccc 0 012 016 0 025 031 0 0,32 0,5 012 0,48 0,68 016 0,66 0,85 0 0,94 1, 025 1,22 *) outer duct Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting Type BD(A,P) range, weights 27 Weights: [kg] Recommended sizes Main tube*, code suffix bbb Reducer BDAD - -bbb -ccc weight/pc ccc 0 012 016 0 025 031 0 0,34 0,48 012 0,46 0,64 016 0,66 1 0 0,88 1,37 025 1,37 Main tube*, code suffix bbb T-Piece BDAT -1 -bbb -ccc weight/pc ccc 0 012 016 0 025 031 0 0,76 0,88 1,06 1, 012 1,06 1, 1,55 016 1,62 1,88 2,32 0 2, 2,88 3,57 025 2,94 3,96 031 4,66 Weights: [kg] Additional sizes Main tube*, code suffix bbb -c Additional sizes 015-1 016-4 018-1 0-4 022-1 022-4 025-4 028-1 031-4 Tube BDPK weight/meter 3,97 3,90 4,67 5, 6,07 6,03 6,43 7,27 8, Tube, sound insulated BDPR weight/meter 3,63 3,77 4,57 4,90 5,67 5,60 6,06 6,73 7,63 Joint BDAM-1 weight/pc 0,27 0,28 0,33 0,36 0,39 0,39 0,55 0,62 0,69 Insertion joint BDAN-1 weight/pc 0,35 0,38 0,43 0,54 0,60 0,58 0,74 0,83 0,95 Insertion join, long BDAN-4 weight/pc 1,12 1,22 1,38 1,55 1,74 1,65 1,96 2,18 2,46 Lid BDAG- weight/pc 0,39 0,39 0,54 0,61 0,72 0,69 0,87 1,11 1,35 Lid BDAG- weight/pc 0,46 0, 0,71 0,79 0,92 0,87 1,15 1, 1,55 Bend 90 BDAB-90 weight/pc 1, 1,52 1,89 2,60 2,92 2,60 3,07 4,13 4,49 Bend 45 BDAB-45 weight/pc 0,79 1,02 1,44 1, 1,78 1,55 2,04 2, 2,82 Bend BDAB- weight/pc 0,58 0,75 0,94 1,02 1,38 1,35 1,42 1,82 2,07 Bend 15 BDAB-15 weight/pc 0,45 0,56 0,66 0,75 0,85 0,79 1,12 1, 1,56 Penetration reducer BDAD-3 weight/pc 0,41 0,38 0,41 0,51 0,62 0,64 0,76 - - Penetration reducer BDAD- weight/pc 0,44 0,43 0,43 0,49 0,65 0,71 0,79 - - Branch BDAA-5 weight/pc 0,45 0, 0,58 0,66 0,77 0,75 0,93 1,11 1, Insulated *) outer duct Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Insulated Miniduct circular ducting 28 Type BD(A,P) range, weights Weights: [kg] Additional sizes Main tube*, code suffix bbb / inner diameter T-Piece BDAT-a-bbb-ccc-d** Additional sizes 015/ 012 016/ 014 018/ 016 0/ 018 022/ 0 022/ 018 025/ 022 028/ 025 031/ 028 Code suffix ccc / inner diameter 0/ 008 1,19 1,27 1,38 012/ 0 1,33 1,47 1,55 015/ 012 1,68 1,80 1,81 016/ 012 1,76 1,82 2,02 2,24 2,17 2,46 016/ 014 1,82 1,88 2,04 2,26 2,21 2,66 018/ 016 2,38 2,39 2,61 2,54 2,91 0/ 016 2,44 2,71 2,65 3,07 3, 3,68 0/ 018 2,45 2,72 2,66 3,05 3,28 3,67 022/ 0 2,97 3, 3,68 3,98 022/ 018 2,89 2,82 3,17 3,54 3,81 025/ 0 3,31 3,64 4,02 025/ 022 3,45 3,73 4,18 028/ 025 4,42 4,79 031/ 025 4,78 031/ 028 4,96 Insulated Reducer Main tube*, code suffix bbb / inner diameter BDAD -1-bbb-ccc-d** BDAD --bbb-ccc-d ** Additional sizes 015/ 012 016/ 014 018/ 016 0/ 018 Code suffix ccc / inner diameter 0,48 / 0/ 008 0,56 012/ 0 015/ 012 016/ 012 016/ 014 018/ 016 0/ 016 0/ 018 022/ 0 022/ 018 0,46 / 0,53 0, / 0,53 0,53 / 0,53 0,53 / 0,60 0,52 / 0,61 0,55 / 0,55 0,64 / 0,62 0,63 / 0,64 0,60 / 0,64 022/ 0 022/ 018 0,81 / 0,82 0,78 / 0,85 0,76 / 0,76 0,73 / 0,80 0,70 / 0,75 0,69 / 0,70 025/ 022 0,99 / 1,11 0,96 / 1,01 0,94 / 1,01 028/ 025 BDAD -1 / BDAD - 0,97 / 0,97 031/ 028 025/ 0 025/ 022 028/ 025 031/ 025 031/ 028 *) outer duct **) code suffix d look at table on page 13 Fläkt Woods EN 14.05 All rights reserved.

80 Marine Catalogue Uninsulated and insulated Miniduct circular ductiong Pressure drop charts 29 Type BDEK spiral tube 0 63 0 0 125 D, mm D (i.d.) 5 4 5 9 8 7 6 Air velocity, m/s -006 15 Size-008-0 -012-016 -0 160 0-025 2-031 315-0 -0 0 0 6 2 3-063 1 2 0.5 Pressure drop p, Pa/m 0.2 0.1 0.05 0.02 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 Air flow, m 3 /s Type BDEB circular bend 45 90 0 0 0 0 Size 006-0 0 5 2 1 0,5 5 2 1 0,5 Pressure drop pt, Pa 1,0 0,5 1 q, m 3 /h 1 q, l/s 2 v, m/s 0 0 0 00 00 00 000 000 0000 5 15 006 008 0 012 016 0 2 0 00 000 0 000 025 031 0 0 5 063 080 15 0 125 Size 025-125 Uninsulated and insulated Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated and insulated Miniduct circular ductiong Pressure drop charts Type BDPK spiral tube, insulated Type BDPR 1) spiral tube, heat and sound insulated Pressure drop in the BDPR tube is 25% higher than in a tube type BDPK. 0 0 5 0 0 0 00 00 00 000 Size D q, m 3 /h Size - 0 012 016 0 025 031 15 1) The inner tube is perforated. 5 d = 80 d = 0 d = 125 d = 160 d = 0 d = 2 Pressure drop p, Pa/m 1,0 1 2 0,1 1 0 00 q, l/s Uninsulated and insulated Type BDAB circular bend, insulated 45 90 0 0 0 0 0 5 5 2 2 1 1 0,5 0,5 1,0 Pressure drop pt, Pa 0,5 1 q, m 3 /h 1 q, l/s 2 v, m/s 0 0 0 00 00 00 000 000 0000 5 15 Size - 0 d=80 d=0 d=125 d=160 d=0 012 016 0 025 d=2 2 d=355 d=4 d=560 0 00 000 0 000 031 5 0 15 0 063 D Size D D Size 025 Size 031-063 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated and insulated Miniduct circular ductiong Pressure drop charts 31 Circular, T-piece, cross The charts are applicable generally to branches, T-pieces and crosses. The pressure drops include any reductions in diameters in accordance with the figures, provided that S < 3 A. T-piece BDET and BDAT (insulated) A S S A 600 0 0 0 0 0 v1 = m/s 28 26 24 22 18 16 14 12 8 6 v2 Pressure drop pt, Pa 4 2 v1 5 0 Air velocity, v2, m/s T-piece BDET and BDAT (insulated) 0 0 12 14 16 18 22 24 v2 = m/s 26 28 v2 = 2m/s 6 14 18 22 26 Uninsulated and insulated Pressure drop pt, Pa 5 2 1 4 6 8 v1 v2 0.5 0 Air velocity, v1, m/s Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated and insulated Miniduct circular ductiong 32 Pressure drop charts Circular, T-piece, cross The charts are applicable generally to branches, T-pieces and crosses. The pressure drops include anyreductions in diameters in accordance with the figures, provided that S < 3 A. 0 v1 v2 Branch BDEA and BDAA (insulated) 0 S S A A 0 Pressure drop pt, Pa 0 v2 = 2 m/s 4 6 8 12 14 16 18 22 24 26 28-0 26 Air velocity, v1, m/s Uninsulated and insulated T-piece BDET and BDAT (insulated) Pressure drop pt, Pa 0 0 5 2 4 6 8 12 14 16 18 22 24 26 v1 = m/s 1 0.7 0 28 v1 = 2 m/s v1 v2 6 14 18 22 26 Air velocity, v2, m/s Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated and insulated Miniduct circular ductiong Pressure drop charts 33 Circular, T-piece, cross The charts are applicable generally to branches, T-pieces and crosses. The pressure drops include any reductions in diameters in accordance with the figures, provided that S < 3 A. T-piece BDET and BDAT (insulated) S S 800 700 600 0 0 0 0 0 v1 = m/s 28 26 24 22 18 16 14 12 A A 8 6 v 1 Pressure drop pt, Pa 4 2 v 2 5 0 Air velocity, v2, m/s T-piece BDET and BDAT (insulated) 00 0 0 0 v2 = m/s 26 22 18 16 14 12 8 Uninsulated and insulated Pressure drop pt, Pa 5 6 4 2 v 1 v 2 2 0 Air velocity, v1, m/s Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Uninsulated and insulated Miniduct circular ductiong 34 Pressure drop charts 90 Reducer BDED and BDAD (insulated) Example: v2 = m/s 28 26 24 22 3 2 v 1 v 2 Size reduction from 0 to 016 = 1 size step. 18 16 14 Size step 1 12 5 4 Pressure drop p t, Pa 3 2 8 6 1 0 26 Air velocity, v 1, m/s Uninsulated and insulated 0 0 v 1 v 2 3 2 Size step 1 Pressure drop p t, Pa 5 2 1 v2 = 2 m/s 4 6 8 12 14 16 18 22 24 0.7 0 Air velocity, v1, m/s Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Content Type BDE Uninsulated Type BDA Insulated 35 Joint Designation Page Joint Designation Page Non-return damper I BDGP-2 6) 44 I BDGP-2 44 Damper, adjustment and shut-off I BDEP 45 I BDAP 45 Joint Designation Page Sound absorber I BDER 43 Damper regulation and measuring I IRIS IRIS-H 52 Damper, regulation and shut-off SPB SPC 53 Plenum box ATTC 61 Ceiling diffusers RMKO RMKP 64 1) F = fit-on dimension I = insertion dimension 2) BDPK heat-insulated BDPR heat and sound insulated and with the inner duct wall perforated for sound absorption. 3) Fit-on dimension in one end and insertion dimension in the other. 4) Non-insulated. 5) Insertion dimension in both ends. 6) Insulated. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Content 36 Joint Designation Page Ceiling diffusers RMRO RMRP 70 Ceiling diffuser CTPB 76 Air diffuser CTUR 81 Air supply unit MCSA 86 Air supply unit MCDA 93 Exhaust valve KGEB 0 Grille SV2 4 Grille USR 8 External louvre RIS 112 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 37 Sound absorber, type BDER-aa-bbb-ccc bbb L Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 For further particulars, see page 35. L L=ccc, see the table on page 35. Non-return damper, type BDGP-2-bbb bbb bbb Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 For further particulars, see page 36. L 185 5 235 275 3 L Air flow adjustment damper, type BDEP-1-bbb-1 Air flow adjustment and shut-off damper, type BDEP-4-bbb-1 70 bbb A Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 For further particulars, see page 37. L B 135 125 160 Li L Adjustment or shut off damper with motor, type BDEP-13-bbb-ccc, BDEP-19-bbb-ccc, BDEP--bbb-ccc 126 bbb Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 For further particulars, see page 41. L 135 125 160 Li L Air insulated adjustment and shut off damper, type BDAP-1 -bbb, BDAP-4 -bbb bbb ØC Li L Recommended sizes Main tube*, code suffix bbb bbb 008 0 012 016 0 025 031 For further particulars, see page 43. L 135 125 Additional sizes Main tube*, code suffix bbb-c bbb 015-1 016-4 018-1 0-1 022-1 022-4 025-4 028-1 031-4 L 135 125 *) outer tube Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 38 IRIS Regulation and measuring damper A A 70 Main tube, code suffix bbb ød B bbb 008 0 012 016 0 025 031 0 0 063 For further particulars, see page 44. L 1 1 1 1 1 132 132 155 170 170 ød L SPB, SPC Regulation and shut off damper SPB For further particulars, see page 45. Width W 0-20 mm Height H 0-2600 mm W x H max, 5m 2 SPC For further particulars, see page. Width W 0-10 mm Height H 0-00 mm Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 39 ATTC Plenum box ATTC For further particulars, see page 75. Width L 3-700 mm Height B 3-570 mm c = 0, 1, 4 c = 2, 3, 6 Min 25 K 12 ½H 12 ½H ½B B ØD2 ØD2 80 L ØD1 H ØD1 H RMKO, RMKP Ceiling diffusers RMKO, RMKP For further particulars, see page 78. A 2, 280, 370, 480, 595 mm ØD 125-0 mm A ØE ØD S H RMRO, RMRP Ceiling diffusers RMRO, RMRP For further particulars, see page 84. ØA 2-5 mm ØD 125-0 mm ØA ØE ØD S H CTPB Ceiling diffuser CTPB For further particulars, see page 90. Size 125, 160 mm ØA 0, 2 mm Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue CTUR Air diffuser CTPB For further particulars, see page 94. ØA 2-570 mm ØD 125-0 mm MCSA Air supply unit MCSA For further particulars, see page 98. A x B 425x425 / 495x495 mm Height C 180 mm F II ØD1 ØD2 II 24 VAC Plug contact (only versions with electric actuator) 32 B 2 VAC connection (only versions with electric re-heater) A E 84 C Min Max 75 MCDA Air supply unit MCDA For further particulars, see page 5. A x B 425x425 / 495x495 mm Height C 180 mm F Cold air ØD1 ØD2 II Warm air Ø79,3 II 24 VAC Plug contact (only versions with electric actuator) 32 B 98 A E 84 C Min Max 75 Fläkt Woods EN 14.05 All rights reserved.

Cleanvent The unique Cleanvent coating keeps dirt away! Fläkt Woods proudly presents the unique Cleanvent nanocoated air terminal devices. The crystal clear choice when cleanliness and energy savings are essential. Reduces the need for cleaning Easy to clean Hygienic ventilation Better life cycle cost www.flaktwoods.com Photo copyright STX Finland

Marine Catalogue 42 KGEB Exhaust valve ø A Main tube, code suffix bbb bbb 008 0 012 016 0 025 031 0 0 063 For further particulars, see page 112. A 1 155 190 SV2 Grille SV2 For further particulars, see page 116. Width W 0 - mm Height H 0-0 mm 22 H W USR Grille H W H + 73 (H - 7) x (W - 7) USR For further particulars, see page 1. Width W 0-00 mm Height H 0, 1, 0 mm 27 RIS External louvre RIS For further particulars, see page 124. Width W 0-1600 mm Height H 0 - mm W + 73 70 19 Ød - 7... 70 Ød + 53... 73 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDER tubular sound absorber 43 The BDER tubular sound absorber is designed for connection to round spiral tubes and tube fittings with standard dimensions. The sound absorber has an insertion dimension at both ends. Higher sound attenuation is available by connecting two or more sound absorbers in series. Sound attenuation, dimensions and weights aa BDER Size length bbb ccc Thickness of wall Attenuation, db Mid-frequency, Hz Fig. 8 Dimension in mm conn. diam. ext. diam. length Wgt. cm t, mm 63 125 2 0 00 00 00 8000 d D L kg 008 0 6 4 9 24 28 35 17 80 0 0 1,7 060 9 5 13 31 38 41 41 23 80 0 600 3,0 0 0 4 5 8 17 26 16 0 0 0 1,8 060 11 7 12 29 37 45 42 23 0 0 600 3,0 090 11 9 17 39 44 47 45 29 0 0 900 4,7 1 11 11 21 49 48 46 31 0 0 5,9 60 0 0 0 2 11 14 17 24 29 17 0 0 0 3,4 060 16 12 27 33 43 44 24 0 0 600 6,0 090 18 16 27 35 44 47 46 27 0 0 900 8,6 1 18 21 36 43 47 45 32 0 0 12,7 012 0 3 5 6 14 16 21 21 14 125 225 0 2,2 060 4 7 25 39 36 19 125 225 600 3,9 090 6 8 13 35 44 47 45 24 125 225 900 5,5 1 5 9 17 47 48 47 31 125 225 7,0 60 012 0 0 3 7 8 12 15 22 14 125 315 0 4,1 060 8 11 15 23 29 38 37 21 125 315 600 7,5 090 14 21 33 42 49 45 26 125 315 900,7 1 13 17 27 39 49 49 48 32 125 315 13,3 016 0 1 2 4 11 13 16 12 160 260 0 2,5 060 3 5 7 21 24 35 27 17 160 260 600 4,6 090 6 6 9 36 46 33 21 160 260 900 6,2 1 6 6 12 33 42 45 25 160 260 8,2 60 016 0 0 2 5 6 9 12 19 17 13 160 355 0 4,8 060 5 7 13 17 22 33 28 18 160 355 600 9,0 090 9 21 28 34 47 34 21 160 355 900 12,3 1 11 13 24 34 43 49 42 26 160 355 00 16,0 0 060 3 3 6 19 22 16 0 0 600 5,2 090 7 5 9 26 29 42 27 0 0 900 7,7 1 7 6 11 34 37 33 23 0 0,0 60 0 060 0 7 6 13 17 29 21 16 0 0 600,1 090 9 9 23 29 43 26 19 0 0 900 14,3 1 11 11 25 31 36 48 33 23 0 0 18,9 025 060 7 2 4 15 18 25 17 16 2 355 600 6,5 090 6 3 6 21 26 34 21 19 2 355 900 9,1 1 6 4 8 28 34 41 25 22 2 355 12,0 60 025 060 0 9 4 12 15 25 19 17 2 4 600 11,7 090 8 7 15 19 24 34 22 2 4 900 16,3 1 8 19 25 38 26 22 2 4 21,8 031 060 1 2 4 12 16 19 15 14 315 415 600 7,9 090 3 3 5 18 24 25 17 16 315 415 900 11,0 1 3 3 7 26 17 315 415 17,3 60 031 060 0 2 5 8 12 16 19 15 14 315 515 600 13,5 090 4 6 12 17 23 26 18 16 315 515 900 19,8 1 5 7 16 19 27 21 17 315 515 25,9 0 090 2 2 6 22 21 18 15 0 0 900 18,0 1 3 2 7 25 29 25 21 17 0 0 22,8 60 0 090 0 4 7 11 19 22 21 19 15 0 6 900 29,0 1 5 9 15 24 27 25 21 17 0 6 36,2 0 090 3 1 5 19 19 13 15 11 0 6 900 24,2 1 3 2 7 23 24 17 17 12 0 6 31,2 60 0 090 0 4 6 8 16 18 15 16 11 0 711 900 33,4 1 4 8 11 21 23 18 18 13 0 711 42,6 60 063 090 0 3 3 6 13 13 12 7 7 6 812 900 38,0 1 5 5 8 16 16 14 9 9 6 812 48,2 t Design The sound absorber consists of a tube of perforated sheet steel enclosed in a casing and end plates made of sheet steel. The space between the tube and the casing is filled with mineral wool. Materials and finish The sound absorber is made of galvanised sheet steel. Pressure drop The pressure drop is calculated as for a straight duct of the same diameter. Fig. 9 Product code L Tubular sound absorber BDER-aa-bbb-ccc (t = mm) 60 (t = 0 mm) Connection dimension, cm (bbb): See table of dimensions Length, cm (ccc): See table of dimensions d D Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 44 BDGP-2 non-return damper The non-return damper is made of galvanised sheet steel. The outside of the damper is provided with glass woll thermal insulation. The damper is provided with circular connection branches with factory-fitted rubber seals. The damper blade is made of aluminium. The underside of the casing is in the form of an inspection cover. Size bbb A B C 1) D Weight, kg 008 185 1 80 1 0.9 0 5 160 0 1 1.2 012 235 185 125 165 1.5 016 275 2 160 0 2.0 0 3 260 0 2 2.8 Fig. 1) Nominal diameter 2) Thickness of insulation Product code Non-return damper BDGP-2-bbb Size (bbb) See table of dimensions 62.5 A 2) B bbb, oc B Inspection cover A D 2) Fig. 11 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDEP damper 45 The type BDEP damper is designed for connection to spiral tubes and is equipped with VELODUCT seals. The damper has insertion dimensions in accordance with European Standard EN 16. The damper is available in the following versions: BDEP-1 Adjustment damper, leakage class 0 BDEP-4 Adjustment and shut-off damper, leakage class 4 Design The damper consists of a cylindrical casing and a damper blade. The blade damper is manually operated and is equipped with a graduated scale for indicating the damper blade angle. BDEP-1 and -4 Sizes 008 031 On dampers up to and including size 031, a knob is provided for adjusting the damper blade angle, on larger sizes a lever is provided. The blade angle can be locked by means of a screw. Also motorized versions are available for the BDEP-1 and -4 dampers (see under Motorized damper ). The torque necessary for operating sizes 008 012 dampers is 2 Nm, and that for other sizes is 8 Nm. Size 0-063 dampers are suitable as standard for ducts with mm thick external insulation. For sizes 008-031 there is snap-on extension handle BDEZ-06 available for ordering when insulation is needed. Materials and finish Shaft bearings, knobs and levers: Glass-fibre reinforced nylon. Fig. 12 BDEP-1 and -4 Sizes 0 063 Other parts: Galvanized sheet steel. Packaging The damper is delivered in unpacked condition. Product code Damper Version (a) 1 = Adjustment damper 4 = Adjustment and shut-off damper Sizes (bbb) BDEP-a-bbb-1 008, 0, 012, 016, 0, 025, 031, 0, 0, 063 Extension handle BDEZ-06 for sizes 008 031 with mm external insulation Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 46 BDEP damper Pressure drop and sound data General a = blade angle α Sound data The sound power level, L W, emitted to the connected duct can be converted to octave bands as follows: L W = L Wt + K 1 + K 2 where L Wt, K 1 and K 2 can be read from the tables and BDEP-1 adjusting damper a = 90 80 70 60 0 Total pressure drop Δpt, Pa L wt = 70 db 0 60 0 Sizes 008 031 1 2 5 15 Air velocity, m/s the charts below. K 1 as a function of size Size 008 0 012 016 0 025 031 0 0 063 K 1, db 2 2 1 0 +1 +2 +3 +4 +5 +6 K 2 as a function of the blade angle Size Blade angle K 2, db Octave band, mid-frequency, Hz α 125 2 0 00 00 00 8000 1 16 18 22 26 31 0 9 15 17 24 1 8 13 14 13 14 21 008 031 3 6 11 12 11 17 60 5 4 8 13 14 19 70 4 5 8 13 15 21 80 4 5 9 11 14 17 23 90 3 6 9 11 14 18 25 0 15 19 21 25 29 33 0 15 19 21 24 28 32 4 14 16 15 18 21 25 0 063 7 13 14 11 11 14 18 60 11 12 11 6 5 8 11 70 14 13 12 6 5 8 12 80 17 15 12 5 5 8 12 0 a = 80 70 60 0 L wt = 80 db Total pressure drop Δpt, Pa 0 60 70 1 2 Air velocity, m/s Sizes 0 063 5 15 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDEP damper 47 BDEP-4 adjusting and shut-off dampers K 2 as a function of the blade angle Total pressure drop Δpt, Pa a = 80 0 0 0 70 60 60 L wt = 70 db Size Blade angle K 2, db Octave band, mid-frequency, Hz α 125 2 0 00 00 00 8000 0 12 15 22 27 32 37 0 9 14 26 36 2 7 12 17 23 29 008 031 4 7 12 15 12 8 8 4 6 8 12 14 17 22 60 6 4 16 18 22 25 70 7 2 13 23 27 35 42 80 13 1 16 24 28 36 45 0 16 18 24 27 31 33 0 13 16 21 26 29 0 063 1 13 17 16 24 5 11 12 13 11 15 19 60 12 13 13 9 6 11 13 1 2 5 Sizes 008 031 15 Air velocity, m/s 0 a = 60 Total pressure drop Δpt, Pa 0 0 60 L wt = 70 db 1 2 Air velocity, m/s Sizes 0 063 5 15 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDEP damper 48 BDEZ-06 Extension handle Dimensions and weights for sizes 008-031 with mm external insulation BDEP-1, -4 Sizes 008 031 A bbb B Li Fig. 15 L Fig. 13 Sizes 0 063 70 A bbb B Li L Fig. 14 L A B 135 135 135 135 135 125 125 160 160 160 65 75 85 5 125 1 180 270 3 385 65 0 1 145 175 2 270 335 Weight, kg 0. 0.34 0.42 0.46 0.82 1.2 1.5 2.7 3.9 5.2 Size bbb 008 0 012 016 0 025 031 0 0 063 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDEP Motorized damper 49 The damper is available in the following versions with respect to the tightness classes in accordance with the European standard EN 1751. Adjusting dampers, leakage class 0 BDEP- Motor mounting bracket, universal Motor shaft Ø15, excl. motor BDEP-13 Type LM...A ON/OFF motor BDEP-19 Type SM...A ON/OFF motor Shut-off dampers, leakage class 4 BDEP- Motor mounting bracket, universal Motor shaft Ø15, excl. motor BDEP-43 Type LM...A ON/OFF motor BDEP-49 Type SM...A ON/OFF motor BDEP-46 Type AF motor with spring return Fig. 16 Type LM...A and SM...A motors are reversible ON/ OFF units. The motor stops automatically when the adjustable stop on the damper motor is reached. The motor is provided with overload protection which eliminates the neccessity of installing limit switches. On delivery, the adjustible stop on the motor is set for a damper opening of 90 o. Type SM2A and SM24A as well as LM2A and LM24A motors may be disenggaged by means of a pushbutton on the casing. The type AF motor is a reversible ON/OFF unit with a pretensioned return spring which operates on loss of power supply. The spring is retensioned when the supply is restored. This unit is delivered with the motor preset to close the damper on loss of power. Code suffix ccc Supply voltage 000= no motor, ready for fitting a motor 024= with motor, 24 V 2= with motor, 2 V Version aa=, 13 and 19, see the chart for BDEP-1, on page 36 aa=, 43, 49 and 46, see the chart for BDEP-4, on page 37 Product code Damper Version (aa) Size (bbb) Supply voltage (ccc) BDEP -aa-bbb-ccc Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDEP Motorized damper Dimensions and weights Type LM...A Belimo motor, versions aa = 13 and 43 Type AF Belimo motor, versions aa = 46 0 126 A A bbb bbb Li Li L Fig. 19 L Fig. 17 Size Size L A bbb Weight, kg L A bbb Weight, kg Incl.motor Excl.motor Incl.motor Excl.motor 0 160 3 7.0 3.7 008 135 160 1.1 0.60 0 160 0 8.3 5.0 0 135 170 1.2 0.65 063 160 465 9.3 6.0 012 135 180 1.3 0.75 016 135 0 1.4 1.0 0 135 2 2.0 1.2 025 125 245 2.4 1.6 031 125 280 2.8 2.0 Damper with motor bracket, universal excl. motor, versions aa = and 1 Type SM...A Belimo motor, versions aa = 19 and 49 A 1 bbb A bbb Li L Fig. Li L Fig. 18 Size L A bbb Weight, kg Size, bbb L A Weight, kg 008 135 190 0,60 0 135 0 0,65 012 135 2 0,75 016 135 2 1,0 Incl.motor Excl.motor 0 135 2 1,2 0 160 315 4.1 3.7 025 125 275 1,6 0 160 365 5.5 5.0 031 125 3 2,0 063 160 4 6.5 6.0 0 160 3 3,7 0 160 0 5,0 063 160 465 6,0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue BDAP Adjustment and shut off damper 51 The type BDAP damper is designed for connection to douple-wall spiral tubes, MINIDUCT. The damper is douple-wall design with intervening air insulation and equipped with VELODUCT seals on both outer and inner wall. BDAP-1 BDAP-4 Adjustment damper, leakage class 0 (EN 1751) Adjustment and shut-off damper, leakage class 4 (EN 1751) Sizes Recommended sizes: 0, 012, 016, 0, 025, 031. Both outer and inner diameters are according to European standard EN 16. We recommend these sizes. Additional sizes (outer/inner): 015/012, 016/014, 018/016, 0/018, 022/0, 022/018, 025/022,, 028/025, 031/028. The size designation specifies the diameter of the outside tube in cm. The inner tube is one size smaller concerning recommended sizes (EN 16). When choosing additional sizes look at diameters and extra designations in chapter C. Sizes and Codes, in the table, on page 13. Pressure drop and sound data BDAP-1, see the chart for BDEP-1 on page 36. BDAP-4, see the chart for BDEP-4 on page 37. Fig. 21 Dimensions and weights Recommended sizes Size Inner diameter Weight bbb C L A B kg 0 80 135 75 0,6 012 0 135 75 65 0,7 016 125 135 85 80 0,9 0 160 135 5 0 1,3 025 0 125 1 145 2,0 031 2 125 180 175 2,7 Additional sizes bbb ØC Fig. 22 Li L A B Size Inner diameter Weight bbb - c C L A B kg 015-1 125 135 0 75 0,9 016-4 1 135 5 0 1,0 018-1 160 135 115 1 1,2 0-4 180 135 125 1 1,5 022-1 0 135 135 1 1,7 022-4 180 135 135 1 1,6 025-4 224 125 1 145 2,2 028-1 2 125 165 160 2,5 031-4 280 125 180 175 2,8 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 52 IRIS Regulation and measuring damper Construction The IRIS is composed of regulation plates, regulating nut or handle (size 80) and regulation scale plus manometer connections and casing. The casing and regulation plates are made of hotgalvanized steel (standard IRIS) or acid-proof steel AISI 316 L (IRIS-aaa-H), other components of plastic. The joining collars are supplied with rubber sealing gasket. Use IRIS is an ideal solution for the exact and quick air flow measuring and regulation. Because of its acid proof material, the IRIS-aaa-H is best suited for premises, where acid proof ducts are used. Product code Installation The IRIS damper is secured to the ducting with rivets. For vertical mounting ensure the weight of the interconnecting ductwork is fully supported. Regulation and measuring device IRIS-aaa-b Diameter in mm (aaa) 80-800 Equipment (b) 1 = IRIS + unit package + spanner (sizes 80 0 mm) 2 = IRIS + spanner (sizes 0 800 mm) Regulation and measuring device, acid-roof IRIS-aaa-H Diameter in mm (aaa) 0-800 Size 80 Sizes 0...800 A A 32 70 A A ød B 70 B ød ød L ød L Size ød ød L A B Weight kg 80 79 125 1 35 22 0,5 0 99 165 1 32 0,5 125 124 188 1 32 0,7 1 149 2 1 0,9 160 159 2 1 35 0,9 0 199 285 1 42 1,4 Size ød ød L A B Weight kg 2 249 335 132 42 2,1 315 314 4 132 47 3,5 0 398 525 1 62 6,4 0 498 655 1 77 9,6 6 628 815 1 92 15,6 800 798 15 285 0 7 25,0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SPB Regulation and shut-off damper 53 Area of application Multi leaf dampers are used as regulation, shut-off and mixing dampers in air handling systems and units. Properties SPB-1 SPB-3 regulation damper for balancing air flows - leakage class: 1 (CEN) - leakage class of casing: B regulation and shut-off damper to be used where low leakage is required - leakage class: 3 (CEN) - leakage class of casing: C SPB-3L shut-off damper to be used where low leakage and effective thermal insulation are required - leakage class: 3 (CEN) - leakage class of casing: C - heat transmission Um = 4 W/m 2 K SPB-3LE shut-off damper to be used where low leakage and effective thermal insulation are required also through the casing (dimensions B+160, H+60) - leakage class: 3 (CEN) - leakage class of casing: C - heat transmission Um = 4 W/m 2 K SPB-4L shut-off damper to be used where low leakage and effective thermal insulation are of great importance - leakage class: 4 (CEN) - leakage class of casing: C - heat transmission Um = 4 W/m 2 K SPB-4LE like 3LE, to be used where low leakage is of great importance Installation - leakage class: 4 (CEN) - leakage class of casing: C - heat transmission Um = 4 W/m 2 K The multi leaf dampers are mounted to air handling units and rectangular ducts by means of a slip joint or a flange joint, and to circular ducts with sealed spigots. The drive shaft is the third shaft from the bottom; in two-blade dampers the upper shaft is the driving one. If the face surface is larger than 5 m 2, the multi leaf damper is put together of two or more units with each having its own actuator. Note! Regulation and shut off dampers SPB and SPC must be installed so that they are not directly exposed to sea air. Construction The casing and blades of a multi leaf damper are made of hot-galvanized steel sheet. The width of the SPB body is 2 mm. The blades are profiled and mechanically jointed and they are linked with a lever mechanism to achieve opposite actions. The bearings and edges of the blades are made of polyamide, the seals are profiled PVC and EPDM. The material used for thermal insulation is mineral wool. Multi leaf dampers are equipped with a base for motor and an external position indicator. The normal operating temperature of multi leaf dampers of standard construction varies between - C and +80 C. All multi leaf damper types are also available in acidproof steel or with joint flange. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SPB Regulation and shut-off damper 54 The difference between widths and heights of available damper sizes is mm. Dimensions Width B 0-20 mm Height H 0-2600 mm If the face surface is larger than 5 m2, the damper is put together of two or more units. Construction and dimensions are agreed on separately. B x H max 5 m2 Slip joint Dampers with flange joints are equipped with Ø5 mm screw holes with 0 mm spacing to enable the mounting e.g. to wall surface without a counterflange. 52 293 x 182 5 base for motor Flange joint 52 293 x 182 The multi leaf damper is also available with a protective cover for the lever mechanism. The protective cover is attached to the damper with screws, so that it can easily be detached e.g. for installation. The protective cover also serves as base for motor. 5 C = 1 when H = 0, 0, etc. C = 170 when H = 0, 0, etc. base for motor Circular joints Joints to ducts in accordance with SFS 3282. 52 5 ød 160 0 2 315 0 0 6 800 00 12 BxH 0 x 0 0 x 0 0 x 0 0 x 0 0 x 0 0 x 0 6 x 6 800 x 800 00 x 00 12 x 12 A 35 35 45 45 85 70 80 1 1 1 base for motor Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SPB Regulation and shut-off damper 55 Motor torque The torque used depends e.g. on the type, width and length of the multi leaf damper, the total length of the sealing surfaces and the mounting method. The motor torque required for the shut-off function of SPB-3 and SPB-4 and the recommended motor type are shown in the tables below. SPB4 SPB3 Product code SPB-XXX - AAA - BBB - C - D - E - F Product SPB-1 SPB-3 SPB-3L SPB-3LE SPB-4L SPB-4LE Nominal size AAA = nominal width mm BBB = nominal height mm Joint 0 = slip joint 1 = flange joint 2 = circular joint (D1) 3 = circular joint on both sides (D2) Material 0 = galvanized steel 1 = acid-proof steel Equipment 0 = standard base for motor 1 = protective cover for lever mechanism Operation 0 = without accessories 1 = manual regulator 2 = regulator with extension, length 10 mm 3 = damper motor installed (the motor must be ordered on a separate line) Example SPB - 3L - 10-1800 - 0-0 - 0-3 Damper with slip joint, nominal size 10x1800, hotgalvanized, tightness class CEN 3 (blades thermally insulated ), motor base of standard type, damper motor mounted SPB - 1-800 - 10-1 - 1-1 - 1 Nm ACTUATOR Nm ACTUATOR Damper with flange joint, nominal size 800x10, acidproof steel, tightness class CEN 1, with control lever casing and manual regulator Nm ACTUATOR Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 56 SPB Regulation and shut-off damper Sound power level L W CORRECTION K oct (db) Medium frequency of octave band (Hz) SPB 63 125 2 0 00 00 00 8000 9 4 1 2-1 -3-8 -12 Toler.± 5 5 5 4 4 4 4 4 Max. allowable pressure difference 00 20 00 CORRECTION K A (db) Face surface area of damper (m 2 ) 0,1 0,15 0,25 0,4 0,6 1,0 1,6 2,5 4,0 - -8-6 -4-2 0 2 4 6 p s (Pa) 10 00 0 The sound power levels of the duct for every octave band are obtained by adding the corrections K oct of octave bands and K A of the face surface (see tables above) to the total sound pressure level L pa, db(a), according to the following formula: 0 0 0 00 10 00 20 Width B of damper (mm) Damper weight L Woct = L pa + K oct + K A 5 4 3 2 Correction K oct is the average in the area of application of SPB. Sound power level L W in duct when damper closed (SPB-3, SPB-3L, SPB-3LE) p L W (A = 1 m 2 ) (Pa) Medium frequency of octave band (Hz) 63 125 2 0 00 00 00 8000 0 43 38 43 47 53 62 69 00 43 41 48 52 56 60 67 70 Face surface 2) (m 1 0,5 0,4 0,3 0,2 0,1 0,05 4 5 6 70 1 Weight (kg) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue Pressure drop and sound data In duct 15 45 60 00 SPB Regulation and shut-off damper 57 L pa 0 0 0 70 db(a) 0 60 75 p s (Pa) 0 90 Open 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) Duct end, extract 15 45 60 00 0 0 0 0 75 90 Open p s (Pa) 0 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) Duct end, supply 15 45 60 00 0 0 0 75 0 p s (Pa) 0 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) 90 Open Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 58 SPC Regulation and shut-off damper Properties SPC-3 leakage class: 3 (CEN) leakage class of casing: C no thermal insulation SPC-3L leakage class: 3 (CEN) leakage class of casing: C blades thermally insulated with mineral wool heat transmission U m = 4,5 W/m 2 K SPC-3LE leakage class: 3 (CEN) leakage class of casing: C blades and casing thermally insulated with mineral wool (outer dimensions B+1, H+60) heat transmission U m = 4,5 W/m 2 K SPC-4 leakage class: 4 (CEN) leakage class of casing: C no thermal insulation SPC-4L leakage class: 4 (CEN) leakage class of casing: C blades thermally insulated with mineral wool heat transmission U m = 4,5 W/m 2 K SPC-4LE leakage class: 4 (CEN) leakage class of casing: C blades and casing thermally insulated with mineral wool (outer dimensions B+1, H+60) heat transmission U m = 4,5 W/m 2 K Area of application Due to its moderate need for space and its excellent mixing performance, SPC is very well suited e.g. for the mixing damper of an air hamdling unit. Installation The damper is mounted to air handling units and ducts by means of a slip joint or a flange joint. The top shaft is the drive shaft. Construction The casing and blades are made of hot-galvanised steel sheet. The width of the SPC body is 1 mm with a slip joint and 1 mm with a flange joint. The blades are profiled and mechanically jointed to achieve high strength and they are linked with a lever mechanism to achieve opposite actions. The bearings and edges of the blades are made of polyamide, the seals are profiled PVC and EPDM. The material used for thermal insulation is mineral wool. The normal operating temperature varies between - C and +80 C. This multi leaf damper type is also available in acid-proof steel or with joint flange. The dampers are equipped with a screw-on cover plate that protects and supports the total length of the gear unit. The motor base is fixedly installed on the cover plate. NOTE! Dampers are never delivered without the protective plate. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SPC Regulation and shut-off damper 59 Product code SPC-XXX - AAA - BBB - C - D - E - F Product SPC-3 SPC-3L SPC-3LE SPC-4 SPC-4L SPC-4LE Nominal size AAA = nominal width mm BBB = nominal height mm Joint 0 = slip joint 1 = flange joint 2 = circular joint (D1) 3 = circular joint on both sides (D2) Material 0 = galvanized steel 1 = acid-proof steel Equipment 1 = protective cover for gear unit + base for motor Operation 0 = without accessories 1 = manual regulator 2 = regulator with extension, length 10 mm 3 = damper motor installed (the motor must be ordered on a separate line) Dimension Width B 0-10 mm in steps of mm Height H 0-00 mm in steps of mm Slip joint x mm Flange joint C 0 C Ø12 B Ø5 B 8 62 15 x 15 mm axel akselituki support 58 15 x 15 mm 32 H + 4 H + 4 1 9 1 4 x 95 mm 32 4 x 95 mm Example C 0 C 9 SPC - 3L - 0-800 - 0-0 - 1-3 damper with slip joint, nominal size 0x800, hotgalvanized, tightness class CEN 3 (blades thermally insulated ), protective cover for gear unit and base for motor, damper motor mounted C = 1 when H = 0, 0, etc. C = 170 when H = 0, 0, etc. Note! SPC dampers are always delivered with protective cover for gear unit. Base for motor is mounted on protective cover. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 60 SPC Regulation and shut-off damper Sound power level L W CORRECTION K oct (db) Medium frequency of octave band (Hz) SPC 63 125 2 0 00 00 00 8000 6 5 3 1 0-4 -8-15 Toler.± 5 5 5 4 4 4 4 4 CORRECTION K A (db) Face surface area of damper (m 2 ) 0,04 0,06 0,1 0,15 0,25 0,4 0,65 1,0 1,6 - -8-6 -4-2 0 2 4 6 The sound power levels of the duct for every octave band are obtained by adding the corrections K oct of octave bands and K A of the face surface (see tables above) to the total sound pressure level L pa, db(a), according to the following formula: L Woct = L pa + K oct + K A Correction K oct is the average in the area of application of SPC. Sound power level L W in duct when damper closed Pressure drop and sound data In duct p s (Pa) 00 0 0 0 0 0 15 45 60 60 L pa db(a) 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) Duct end, extract 00 0 0 0 0 80 15 45 60 75 70 90 Open 75 90 Open p L W (A = 1 m 2 ) (Pa) Medium frequency of octave band (Hz) 63 125 2 0 00 00 00 8000 0 34 37 41 49 54 56 59 54 00 43 41 45 53 59 62 65 64 p s (Pa) 0 Motor torque The torque used depends e.g. on the type, width and length of the multi leaf damper, the total length of the sealing surfaces and the mounting method. The motor torque required for the shut-off function of SPC and the recommended motor type are shown in the table beside. SPC3 00 0 0 0 0 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) Duct end, supply 15 45 60 75 90 Open Nm ACTUATOR Nm ACTUATOR p s (Pa) 0 5 0,5 1 2 3 4 5 6 Face surface velocity v (m/s) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue ATTC Plenum box 61 ØD1 ØD1 ATTC is a range of plenum boxes for all types of air diffuser. The diffuser connection collar is either inwards or outwards in the plenum box and, thus, the plenum box needs less space. The same ATTC plenum box is applicable for supply and exhaust air alike. In exhaust air use, the position of the measuring hose is changed to the measuring connector inside the box. ATTC is available in two models, insulated and uninsulated. The insulation material used in the insulated box is polyester fibre or glass wool (marine versions). Patented insulation profiles are designed to direct air flow in order to provide an air distribution that is as uniform as possible. They are easy to remove for cleaning. The patented multipoint measuring of the measurement and adjustment damper enables balanced and accurate values. The adjustment handle of the measurement and adjustment damper has a position indicator and a locking device. For minor damper openings the measurement and adjustment damper features a fine tuning function that is operated by turning the adjustment ring on the adjustment handle. With larger openings the sliding adjustment provides fast settings. The setting is locked by turning the adjustment ring to the locking position. The measurement and adjustment damper can be easily dismantled for inspection and cleaning without changing the setting of the damper. The adjusting cable has k-factors for different installations (supply air) so that the box can be connected directly to an elbow. For k-factors for exhaust air, see adjustment instructions for the respective device. For installation purposes, the plenum box is provided with a quick bracket for a threaded bar. The range of duct connection diameters for the plenum box is 0-315 mm. The range of connection diameters for diffusers is 0 0 mm. Product facts Includes measurement and adjustment damper ZAEE. The damper is easily dismantled without changing the settings. The insulation profiles of an insulated box can be easily removed for cleaning K-factors on adjusting cable (supply air) Made of galvanized sheet metal. Product code example: Insulated plenum box, diffuser collar outwards, marine insulated ATTC-125-0-4 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 62 ATTC Plenum box Dimensions and weights Function Min 25 80 L K ½B B ATTC is a range of plenum boxes for all types of air diffuser. The range of duct connection diameters for the plenum box is 0-315 mm. The range of connection diameters for diffusers is 0-0 mm. For settings 0-1 the adjustment handle is operated by turning the adjustment ring and for settings 1-4 (sizes 0-125) or 1-5 (sizes 160-315) by sliding. The setting is locked in position by turning the adjustment ring approx. 45 clockwise c = 0, 1, 4 c = 2, 3, 6 12 ½H 12 ½H 0-1 ØD2 ØD2 ØD1 H ØD1 H Model 1:1 ATTC ØD1 mm ØD2 mm H mm L mm B mm K mm Weight kg 0-0 99,3 0 170 3 3 1 2,1 125-125 124,3 125 170 470 3 1 3,0 160-160 159,3 160 5 0 4 170 4,0 0-0 199,3 0 245 6 480 195 5,5 2-2 249,3 2 295 700 570 225 6,9 315-315 314,3 315 360 700 570 225 8,1 1-4 (0-125) 1-5 (160-315) Model 1:2 ATTC ØD1 mm ØD2 mm H mm L mm B mm K mm Weight kg 0-125 99,3 125 170 3 3 1 2,1 125-160 124,3 160 170 470 3 1 3,0 160-0 159,3 0 5 0 4 170 4,0 0-2 199,3 2 245 6 480 195 5,5 2-315 249,3 315 295 700 570 225 6,9 315-0 314,3 0 360 700 570 225 8,0 Model 1:3 ATTC ØD1 mm ØD2 mm H mm L mm B mm K mm Weight kg 0-160 99,3 160 170 3 3 1 2,3 125-0 124,3 0 170 470 3 160 2,9 160-2 159,3 2 5 0 4 160 4,0 0-315 199,3 315 245 6 480 7 5,4 2-0 249,3 0 295 700 570 225 6,9 315-0 314,3 0 360 700 570 270 7,9 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue ATTC Plenum box 63 Material Made of galvanized sheet steel. Sound insulation material is polyester fibre and marine insulation material is glass wool. K-factor for supply air K-factor for exhaust air, see adjustment instruction for the respective device. 0ØD1 1-7ØD1 1-7 x ØD1 >7 x ØD1 >7ØD1 ØD1 0ØD1 1-7ØD1 >7ØD1 0 6,0 6,3 5,9 125,1,6,1 160 17,1 19,9 17,3 0 27,0,8 27,9 2 47,1 48,8 39,9 315 65,9 67,2 64,1 Product code Plenum box 1:1 ATTC-aaa-bbb-c Size, mm (aaa-bbb) 0-0, 125-125, 160-160, 0-0, 2-2, 315-315 (Box connection diameter - diffuser connection diameter) Type (c) 0 = uninsulated 1 = sound insulated 2 = low, uninsulated 3 = low, sound insulated 4 = marine insulated 6 = low, marine insulated The plenum boxes 1:1 have the same inlet and outlet diameters. The damper can be detached from the connection, but cannot be taken out of the plenum box. Plenum box 1:2 ATTC-aaa-bbb-c Size, mm (aaa-bbb) 0-125, 125-160, 160-0, 0-2, 2-315, 315-0 (Box connection diameter - diffuser connection diameter) Type (c) 0 = uninsulated 1 = sound insulated 2 = low, uninsulated 3 = low, sound insulated 4 = marine insulated 6 = low, marine insulated Plenum box 1:3 ATTC-aaa-bbb-c Size, mm (aaa-bbb) 0-160, 125-0, 160-2, 0-315, 2-0, 315-0 (Box connection diameter - diffuser connection diameter) Type (c) 0 = uninsulated 1 = sound insulated 2 = low, uninsulated 3 = low, sound insulated 4 = marine insulated 6 = low, marine insulated Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 64 RMKO and RMKP Ceiling diffusers RMKO RMKP ATTC RMK(P,O) is a range of quiet ceiling air diffusers with good mixing of room air. The diffusers can cope with large undertemperatures ( 12 C). RMKP - Square perforated diffuser without/with plenum box ATTC. RMKO - Square unperforated diffuser without/with plenum box ATTC Quick selection (4-way diffusion, 25 mm slot, supply air at Pa) RMKO, RMKP with insulated plenum box Air diffuser Plenum box ATTC Air flow l/s (m3/h) at sound level Size inlet, mm 25dB db 35 db RMK(O,P)-160 0 31 (144) - RMK(O,P)-0 125 65 - - - RMK(O,P)-2 160 75 98 (353) - RMK(O,P)-315 0 1 138 (497) - RMK(O,P)-0 2 135 175 (6) 5 Product facts Adjustable diffusion pattern Safety line on diffuser lower part Plenum box ATTC Measurement and adjustment damper easily removable without disturbing the setting K-factors on measurement hoses Product code example: Square perforated ceiling diffuser RMRP-0 with insulated plenum box ATTC-125-0-4. RMKO, RMKP with uninsulated plenum box Air diffuser Plenum box ATTC Air flow l/s (m3/h) at sound level Size inlet, mm 25dB db 35 db RMK(O,P)-125 0 27 36 (1) - RMK(O,P)-160 125 35 47 (169) 56 RMK(O,P)-0 160 57 80 (288) 99 RMK(O,P)-2 0 80 1 (396) 1 RMK(O,P)-315 2 1 158 (569) 182 RMK(O,P)-0 315 152 190 (684) 232 - = outside working area Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMKO and RMKP Ceiling diffusers 65 Air diffuser with plenum box, 4-way diffusion and nominal slot 25 mm Zone length L and throw l 0,2 The size designation in the zone and throw graph indicates the air diffuser connection in mm. l 0,2, m 5 4 3 2 L, m q, m 3 /h 0 0 0 00 5 4 3 2 125 160 0 2 315 0 RMK(O, P) 125 + ATTC-0-125-0 pt, Pa 0 0 0 0% 25 35 L A, db(a) 0% 1 1 0 0 0 q, l/s RMK(O, P) 160 + ATTC-0-160-4 pt, Pa 0 0 0 0% 80 q, l/s 25 35 L A, db(a) 0% 80 q, l/s RMK(O, P) 160 + ATTC-125-160-0 p t, Pa 0 0 0 0% 0% 0 1 q, l/s 25 35 L A, db(a) RMK(O, P) 0 + ATTC-125-0-4 0 0 0% 0% RMK(O, P) 0 + ATTC-160-0-0 0 0 0% p t, Pa 0 35 25 L A, db(a) 0 1 q, l/s p t, Pa 0 35 25 0 1 q, l/s L A, db(a) 0% RMK(O, P) 2 + ATTC-160-2-4 p t, Pa 0 0 0 0 1 q, l/s 0% 25 35 L A, db(a) 0% RMK(O, P) 2 + ATTC-0-2-0 p t, Pa 0 0 0 0% 0 0 q, l/s 25 35 L A, db(a) 0% Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 66 RMKO and RMKP Ceiling diffusers RMK(O, P) 315 + ATTC-0-315-4 pt, Pa 0 0 0 0% 0 0 2 q, l/s 25 35 L A, db(a) 0% RMK(O, P) 315 + ATTC-2-315-0 pt, Pa 0 0 0 0% 25 0 0 0 q, l/s 35 L A, db(a) 0% RMK(O, P) 0 + ATTC-2-0-4 0 0 0% RMK(O, P) 0 + ATTC-315-0-0 0 0 0% pt, Pa 0 0% 35 25 0 0 0 q, l/s L A, db(a) p t, Pa 0 0% 35 25 0 0 0 q, l/s L A, db(a) Supply air diffuser without plenum box, 4-way diffusion and nominal slot 25 mm l 0,2, m 5 4 3 2 1 L, m q, m 3 /h 0 0 0 00 5 4 3 2 1 0, 125 160 0 2 315 0 0 0 0 q, l/s p t, Pa 0 0 125 160 0 35 25 0 0 q, l/s 45 0 L A, db(a) 2 315 0 Conversion factors Throw l 0.2, zone length L and noise generation L A are indicated for normal 4-way diffusion. When setting other diffusion patterns, these are changed on the basis of conversion with the following factors. Diffusion Throw Zone length Noise generation pattern l 0.2, m L, m L A, dba) 3-way 1,4 1,4 + 2 2-way 1,9 1,9 + 4 1-way 2,4 2,4 + 6 For complete dimensioning details, please see Fläkt Woods product selection program. Ceiling diffusers RMKO, RMKP can also be set with a narrow slot (15 mm) and a wide slot (35 mm). Pressure and sound data for narrow and wide slots are included in our product selection program and on the Internet at www.flaktwoods.com. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMKO and RMKP Ceiling diffusers 67 Sound power level L w Subdivision into frequency-divided sound power L w is done on the basis of the L A values in the graphs and the correction K oct below. RMK(O,P) with insulated plenum box Size Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 160 9 9 6-2 -3-3 -11-13 0 6-1 -3-5 -12-13 2 11 5 1-4 -6-13 -14 315 13 12 5 1-3 -7-13 -14 0 15 13 6 1-5 -11-14 -14 Tolerance ± 6 3 2 2 2 2 2 3 RMK(O,P) with uninsulated plenum box Size Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 125 16 9 4-1 -1-6 -14-13 160 5 6 3 2-3 -4-11 -18 0 9 3 1-1 -9-14 -13 2 8 5 1-3 -8-13 -14 315 9 4 1-3 -4-8 -12 0 11 8 4 1-4 -4-6 - Tolerance ± L w = L A + K oct 6 3 2 2 2 2 2 3 RMK(O,P) with uninsulated plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 125 14 15 13 11 14 8 6 8 160 19 9 11 12 4 7 6 8 0 17 8 4 4 6 8 2 17 8 9 7 5 5 6 9 315 9 6 6 3 5 5 6 0 7 6 4 3 3 3 4 6 Tolerance ± 6 3 2 2 2 2 2 3 RMK(O,P) without plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 125 15 4 3 2 3 4 160 18 12 8 4 3 2 4 5 0 16 8 7 5 3 1 3 4 2 14 8 5 5 3 3 5 6 315 12 7 6 6 2 3 4 5 0 5 7 4 2 2 4 7 Tolerance ± 6 3 2 2 2 2 2 3 Air stream diffusion Vertical bv = 0,07 x l 0,2 bv RMK(O,P) without plenum box Size Sound attenuation ΔL RMK(O,P) with insulated plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 160 15 16 12 15 18 11 15 0 15 8 11 7 11 11 14 2 15 9 9 8 9 8 13 315 7 6 5 8 12 15 0 12 5 5 3 8 9 14 Tolerance ± Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 125 9 12 7 1-1 -1-15 - 160 8 12 5 1 0 - -15-0 7 8 4 2 0-8 -15-2 8 7 2 4-1 -9-15 - 315 7 12 3 2-2 -6-15 - 0 14 13 4 2-2 -12-15 - Tolerance ± 6 3 2 2 2 2 2 3 6 3 2 2 2 2 2 3 Horizontal 4-way diffusion radial diffusion 360 3-way diffusion radial diffusion ca 270 2-way diffusion bh = 0,85 x l 0,2 (diffusion pattern 180 ) bh = 1, x l 0,2 (diffusion pattern 90 ) 90 bh l 0,2 180 1-way diffusion bh = 0,85 x l 0,2 l 0,2 l 0,2 l 0,2 l 0,2 bh bh Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 68 RMKO and RMKP Ceiling diffusers Dimensions and weights Ceiling diffusers RMKO, RMKP Product summary A ØE ØD RHSZ-04-aaa RHSZ-05 H S S = 15, 25, 35 mm RHSZ-01-aaa RHSZ-02 Koko A ØD ØE 1) H Weight, kg 125 2x2 124,3 160 60 0,6 160 280x280 159,3 0 60 0,9 0 370x370 199,3 0 45 1,1 2 480x480 249,3 0 45 1,6 315 595x595 314,3 0 60 2,2 0 595x595 399,3 0 60 2,3 1) Assembly opening RMKP RMKO Plenum box ATTC Min 25 K Application and function ½B B 80 L c = 0, 1, 4 c = 2, 3, 6 12 ½H 12 ½H ØD2 ØD2 RMK(O, P) are ceiling air diffusers with good technical characteristics. Diffusion directions and throw can be changed easily, and a measurement socket is provided on the terminal to facilitate access when balancing and measuring the air flow. The plenum box ATTC has a combined measurement and adjustment damper with very low noise generation. The measurement and adjustment damper can be easily dismantled for inspection and cleaning without changing the setting of the damper. The plenum box is insulated or uninsulated and its airtightness class is C. The perforated diffuser RMKP can also be used as an exhaust air terminal. Material and surface finish Size ØD1 H ØD1 mm ØD2 mm H mm L mm ØD1 B mm K mm Weight kg 0-125 99,3 125 170 3 3 123 2,3 0-160 99,3 160 170 3 3 1 2,9 125-160 124,3 160 170 470 3 1 2,9 125-0 124,3 0 170 470 3 160 3,0 160-0 159,3 0 5 0 4 170 4,2 160-2 159,3 2 5 0 4 195 4,2 0-2 199,3 2 245 6 5 195 5,7 0-315 199,3 315 245 6 5 228 6,0 2-315 249,3 315 295 700 570 228 7,6 2-0 249,3 0 295 700 570 255 7,8 315-0 314,3 0 360 700 570 255 8,0 H Air diffusers RMKO, RMKP and plenum box ATTC are made from hot-dip galvanized steel sheet. The diffusers are powder coated for a high surface finish and good impact and scratch resistance. Standard colour RAL-90. Other colours on request. Instructions Instructions for installation, adjustment and maintenance are supplied with every product. The instructions are also available on www.flaktwoods.com. Technical data and dimensioning For complete dimensioning details, please see Fläkt Woods product selection program. Contact our nearest sales office for further information. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMKO and RMKP Ceiling diffusers 69 Product code Ceiling diffuser Execution P = perforated air diffuser O = unperforated air diffuser RMK(P,O)-aaa False ceiling plate, painted 595x595 Size of diffuser connection in mm (aaa) 125,160, 0, 2 RHSZ-01-aaa-b Size (diffuser connection in mm) 125, 160, 0, 2, 315, 0 Diffuser type (b) 2 = for square terminal Plenum box Duct connection in mm (aaa) Diffuser connection in mm (bbb) Type (c) 0 = uninsulated 4 = marine insulated ATTC-aaa-bbb-c Screw kit RHSZ-02 For fine adjustment of the diffuser s vertical position Extension sleeve Height 70 mm. RHSZ-04-aaa Size of diffuser connection in mm (aaa) 125,160, 0, 2, 315, 0 An extension sleeve is used to take up differences in height between the connection box and the ceiling Profiles for installation in a false ceiling (kit) RHSZ-05 The profiles are adapted for false ceilings with c - c 600 mm between the ceiling profiles and are used for centring the air diffuser in the false ceiling plate. The profiles are provided with grooves for the respective size of connection box. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 70 RMRO and RMRP Ceiling diffusers RMRO RMRP ATTC RMR(P,O) is a range of quiet ceiling air diffusers with good mixing of room air. The diffusers can cope with large undertemperatures ( 12 C). RMRP - Round perforated diffuser without/with plenum box ATTC. RMRO - Round unperforated diffuser without/with plenum box ATTC Quick selection (4-way diffusion, 25 mm slot, supply air at Pa) RMRO, RMRP with insulated plenum box Air diffuser Plenum box ATTC Air flow l/s (m 3 /h) at sound level Size inlet, mm 25dB db 35 db RMR(O,P)-160 0 31 (144) - RMR(O,P)-0 125 65 - - - RMR(O,P)-2 160 75 98 (353) - RMR(O,P)-315 0 1 138 (497) - RMR(O,P)-0 2 135 175 (6) 5 Product facts Adjustable diffusion pattern Safety line on diffuser lower part Plenum box ATTC Measurement and adjustment damper easily removable without disturbing the setting K-factors on measurement hoses Product code example: Circular perforated ceiling diffuser RMRP-0 with insulated plenum box ATTC-125-0-4. RMRO, RMRP with uninsulated plenum box Air diffuser Plenum box ATTC Air flow l/s (m 3 /h) at sound level Size inlet, mm 25dB db 35 db RMR(O,P)125 0 27 36 (1) - RMR(O,P)-160 125 35 47 (169) 56 RMR(O,P)-0 160 57 80 (288) 99 RMR(O,P)-2 0 80 1 (396) 1 RMR(O,P)-315 2 1 158 (569) 182 RMR(O,P)-0 315 152 190 (684) 232 - = outside working area Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMRO and RMRP Ceiling diffusers 71 Air diffuser with plenum box, 4-way diffusion and nominal slot 25 mm Zone length L and throw l 0,2 The size designation in the zone and throw graph indicates the air diffuser connection in mm. l 0,2, m 5 4 3 2 L, m q, m 3 /h 0 0 0 00 5 4 3 2 125 160 0 2 315 0 RMR(O, P) 125 + ATTC-0-125-0 pt, Pa 0 0 0 0% 25 35 L A, db(a) 0% 1 1 0 0 0 q, l/s RMR(O, P) 160 + ATTC-0-160-4 pt, Pa 0 0 0 0% 80 q, l/s 25 35 L A, db(a) 0% 80 q, l/s RMR(O, P) 160 + ATTC-125-160-0 p t, Pa 0 0 0 0% 0% 0 1 q, l/s 25 35 L A, db(a) RMR(O, P) 0 + ATTC-125-0-4 0 0 0% 0% RMR(O, P) 0 + ATTC-160-0-0 0 0 0% p t, Pa 0 35 25 L A, db(a) 0 1 q, l/s p t, Pa 0 35 25 0 1 q, l/s L A, db(a) 0% RMR(O, P) 2 + ATTC-160-2-4 p t, Pa 0 0 0 0 1 q, l/s 0% 25 35 L A, db(a) 0% RMR(O, P) 2 + ATTC-0-2-0 p t, Pa 0 0 0 0% 0 0 q, l/s 25 35 L A, db(a) 0% Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 72 RMRO and RMRP Ceiling diffusers RMR(O, P) 315 + ATTC-0-315-4 pt, Pa 0 0 0 0% 0 0 2 q, l/s 25 35 L A, db(a) 0% RMR(O, P) 315 + ATTC-2-315-0 pt, Pa 0 0 0 0% 25 0 0 0 q, l/s 35 L A, db(a) 0% RMR(O, P) 0 + ATTC-2-0-4 0 0 0% RMR(O, P) 0 + ATTC-315-0-0 0 0 0% pt, Pa 0 0% 35 25 0 0 0 q, l/s L A, db(a) p t, Pa 0 0% 35 25 0 0 0 q, l/s L A, db(a) Supply air diffuser without plenum box, 4-way diffusion and nominal slot 25 mm l 0,2, m 5 4 3 2 1 L, m q, m 3 /h 0 0 0 00 5 4 3 2 1 0, 125 160 0 2 315 0 0 0 0 q, l/s p t, Pa 0 0 125 160 0 35 25 0 0 q, l/s 45 0 L A, db(a) 2 315 0 Conversion factors Throw l 0.2, zone length L and noise generation L A are indicated for normal 4-way diffusion. When setting other diffusion patterns, these are changed on the basis of conversion with the following factors. Diffusion Throw Zone length Noise generation pattern l 0.2, m L, m L A, dba) 3-way 1,4 1,4 + 2 2-way 1,9 1,9 + 4 1-way 2,4 2,4 + 6 For complete dimensioning details, please see Fläkt Woods product selection program. Ceiling diffusers RMRO, RMRP can also be set with a narrow slot (15 mm) and a wide slot (35 mm). Pressure and sound data for narrow and wide slots are included in our product selection program and on the Internet at www.flaktwoods.com. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMRO and RMRP Ceiling diffusers 73 Sound power level L w Subdivision into frequency-divided sound power L w is done on the basis of the L A values in the graphs and the correction K oct below. RMR(O,P) with insulated plenum box Size Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 160 9 9 6-2 -3-3 -11-13 0 6-1 -3-5 -12-13 2 11 5 1-4 -6-13 -14 315 13 12 5 1-3 -7-13 -14 0 15 13 6 1-5 -11-14 -14 Tolerance ± 6 3 2 2 2 2 2 3 RMR(O,P) with uninsulated plenum box Size Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 125 16 9 4-1 -1-6 -14-13 160 5 6 3 2-3 -4-11 -18 0 9 3 1-1 -9-14 -13 2 8 5 1-3 -8-13 -14 315 9 4 1-3 -4-8 -12 0 11 8 4 1-4 -4-6 - Tolerance ± L w = L A + K oct 6 3 2 2 2 2 2 3 RMR(O,P) with uninsulated plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 125 14 15 13 11 14 8 6 8 160 19 9 11 12 4 7 6 8 0 17 8 4 4 6 8 2 17 8 9 7 5 5 6 9 315 9 6 6 3 5 5 6 0 7 6 4 3 3 3 4 6 Tolerance ± 6 3 2 2 2 2 2 3 RMR(O,P) without plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 125 15 4 3 2 3 4 160 18 12 8 4 3 2 4 5 0 16 8 7 5 3 1 3 4 2 14 8 5 5 3 3 5 6 315 12 7 6 6 2 3 4 5 0 5 7 4 2 2 4 7 Tolerance ± 6 3 2 2 2 2 2 3 Air stream diffusion Vertical bv = 0,07 x l 0,2 bv RMR(O,P) without plenum box Size Correction of sound level K oct (db) 63 125 2 0 00 00 00 8000 Hz 125 9 12 7 1-1 -1-15 - 160 8 12 5 1 0 - -15-0 7 8 4 2 0-8 -15-2 8 7 2 4-1 -9-15 - 315 7 12 3 2-2 -6-15 - 0 14 13 4 2-2 -12-15 - Tolerance ± 6 3 2 2 2 2 2 3 Horizontal 4-way diffusion radial diffusion 360 3-way diffusion radial diffusion ca 270 l 0,2 l 0,2 Sound attenuation ΔL RMR(O,P) with insulated plenum box Size Sound attenuation ΔL (db) 63 125 2 0 00 00 00 8000 Hz 160 15 16 12 15 18 11 15 0 15 8 11 7 11 11 14 2 15 9 9 8 9 8 13 315 7 6 5 8 12 15 0 12 5 5 3 8 9 14 Tolerance ± 6 3 2 2 2 2 2 3 2-way diffusion bh = 0,85 x l 0,2 (diffusion pattern 180 ) bh = 1, x l 0,2 (diffusion pattern 90 ) 90 bh l 0,2 180 1-way diffusion bh = 0,85 x l 0,2 l 0,2 bh bh l 0,2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 74 RMRO and RMRP Ceiling diffusers Dimensions and weights Ceiling diffusers RMRO, RMRP Product summary ØA ØE ØD RHSZ-04-aaa RHSZ-05 H S S = 15, 25, 35 mm RHSZ-01-aaa RHSZ-02 Size ØA ØD ØE 1) H Weight kg 125 2 124,3 160 60 0,6 160 2 159,3 0 60 0,9 0 3 199,3 0 45 1,1 2 4 249,3 0 45 1,6 315 5 314,3 0 60 2,2 0 5 399,3 0 60 2,3 1) Assembly opening RMRP RMRO Plenum box ATTC Min 25 Size ØD1 mm ØD2 mm H mm L mm B mm K mm Weight kg 0-125 99,3 125 170 3 3 123 2,3 0-160 125-160 125-0 160-0 160-2 0-2 0-315 2-315 2-0 315-0 99,3 124,3 124,3 159,3 159,3 199,3 199,3 249,3 249,3 314,3 80 L 160 160 0 0 2 2 315 315 0 0 170 170 170 5 5 245 245 295 295 360 ½B c = 0, 1, 4 c = 2, 3, 6 12 ½H 12 ½H ØD1 ØD2 H K 3 470 470 0 0 6 6 700 700 700 B ØD1 H 3 3 3 4 4 5 5 570 570 570 ØD2 1 1 160 170 195 195 228 228 255 255 2,9 2,9 3,0 4,2 4,2 5,7 6,0 7,6 7,8 8,0 Application and function RMR(O, P) are ceiling air diffusers with good technical characteristics. Diffusion directions and throw can be changed easily, and a measurement socket is provided on the terminal to facilitate access when balancing and measuring the air flow. The plenum box ATTC has a combined measurement and adjustment damper with very low noise generation. The measurement and adjustment damper can be easily dismantled for inspection and cleaning without changing the setting of the damper. The plenum box is insulated or uninsulated and its airtightness class is C. The perforated diffuser RMRP can also be used as an exhaust air terminal. Material and surface finish Air diffusers RMRO, RMRP and plenum box ATTC are made from hot-dip galvanized steel sheet. The diffusers are powder coated for a high surface finish and good impact and scratch resistance. Standard colour RAL-90. Other colours on request. Instructions Instructions for installation, adjustment and maintenance are supplied with every product. The instructions are also available on www.flaktwoods.com. Technical data and dimensioning For complete dimensioning details, please see Fläkt Woods product selection program. Contact our nearest sales office for further information. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RMRO and RMRP Ceiling diffusers 75 Product code Ceiling diffuser Execution P = perforated air diffuser O = unperforated air diffuser RMR(P,O)-aaa False ceiling plate, painted 595x595 Size of diffuser connection in mm (aaa) 125,160, 0, 2, 315, 0 RHSZ-01-aaa-b Size (diffuser connection in mm) 125, 160, 0, 2, 315, 0 Diffuser type (b) 1 = for circular terminal Plenum box Duct connection in mm (aaa) Diffuser connection in mm (bbb) Type (c) 0 = uninsulated 4 = marine insulated ATTC-aaa-bbb-c Screw kit RHSZ-02 For fine adjustment of the diffuser s vertical position Extension sleeve Height 70 mm. RHSZ-04-aaa Size of diffuser connection in mm (aaa) 125,160, 0, 2, 315, 0 An extension sleeve is used to take up differences in height between the connection box and the ceiling. Profiles for installation in a false ceiling (kit) RHSZ-05 The profiles are adapted for false ceilings with c - c 600 mm between the ceiling profiles and are used for centring the air diffuser in the false ceiling plate. The profiles are provided with grooves for the respective size of connection box. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 76 CTPB Ceiling diffuser CTPB is a quiet 1-way air diffuser, which is normally positioned in a ceiling, although it can also be positioned on a wall. The air gap is variable, and the desired air diffusion direction can be set by rotating the diffuser. The diffuser is easily installed on the mounting ring with mounting brackets and is easy to keep clean thanks to its large, smooth surfaces. CTPB is available in two sizes, with connections 125 and 160. Quick selection at Pa Air diffuser Connection, mm Air flow l/s (m 3 /h) at sound level Size Diffuser with box 25 db db 35 db CTPB-125 0-125 33 38 (119) - CTPB-160 125-160 48 56 (2) - Product facts High sound attenuation Easy to install Product code example: Ceiling diffuser CTPB-125 Plenum box ATTC-0-125-4 Mounting ring KGEZ-01 - = outside working area Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue CTPB Ceiling diffuser 77 Size 125 Size 160 q, m3/h 0 0 2 q, m3/h 0 0 360 Throw, m 5 2 Zone length, m 5 2 s = mm 35 Throw, m 5 2 Zone length, m 5 2 s = 25 mm 1 1 70 q, l/s 1 1 0 q, l/s Size 125 with plenum box ATTC-0-125-4 Size 160 with plenum box ATTC-125-160-4 Δp t, Pa 0 0 0 0 % L A, db(a) 60 q, l/s 0 % 25 35 Δp t, Pa 0 0 0 0 % 25 0 q, l/s 35 L A, db(a) 0 % Size 125 without plenum box Size 160 without plenum box 1 1 Δp t, Pa 0 45 25 35 15 60 q, l/s s = mm s = 35 mm LA, db (A) Δpt, Pa 0 s = 25 mm s = mm 25 25 0 q, l/s 35 LA, db (A) 45 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 78 CTPB Ceiling diffuser Air stream diffusion bv Dimensions and weights Ceiling diffuser CTPB 1-way bv = l 0,2 x 0,1 bh = l 0,2 x 1,5 l 0,2 bh Sound power level Subdivision into frequency-divided sound power L w is done on the basis of the L A values in the graphs and the correction K oct below.: L w = L A + K oct Ceiling diffuser without plenum box Size Size Size Correction of sound level, K oct in db at 63 125 2 0 00 00 00 8000 Hz 125 4 4 3-2 -8-14 -14 160 8 3 2-2 -6-14 -14 Ceiling diffuser with plenum box Correction of sound level, K oct in db at 63 125 2 0 00 00 00 8000 Hz 125/0-125 9 8 6 1-2 -7-8 -8 160/125-160 9 5 2-4 -7-8 -7 Sound attenuation Ceiling diffuser without plenum box Sound attenuation in db at 63 125 2 0 00 00 00 8000 Hz 125 16 12 7 6 8 8 160 19 14 11 16 12 8 8 Ceiling diffuser with plenum box l 02 Size A B Smin Smax Dmax Weight, kg 125 0 17,5 35 54 0,55 160 2 25,0 25 59 0,80 B = eccentricity Plenum box ATTC Min 25 K 12 80 L Size ØD1 ØD2 H L B K W 0-125 99,3 125 170 3 3 123 2,3 125-160 124,3 160 170 470 3 1 2,9 W = Weight, kg ½B Hole dimensions = D2 + ± 5 mm Mounting rings KGEZ-01, KGEZ-05 B ØD1 ½H ØD2 H Size Sound attenuation in db at 63 125 2 0 00 00 00 8000 Hz 125/0-125 21 16 12 16 16 11 9 8 160/125-160 19 14 11 16 12 8 8 Instructions Directions for installation, adjustment and care are set out in detail in our technical instruction which accompanies each product. The instruction is also accessible on www.flaktwoods.com. Packaging The air diffuser is supplied as standard in a carton containing: Size Quanitity Weight, kg Volume, m 3 CTPB-125 12 0, CTPB-160 24 0,12 ØA 44 46 EXT. ØD1 INT. ØD2 KGEZ-01 KGEZ-05 Size A D1 D2 Weight, kg Holes 1) 125 1 124,3 125 0, Ø 135 160 185 159,3 160 0,16 Ø 170 1) Tolerance ± 5 mm Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue CTPB Ceiling diffuser 79 Installation Air diffuser connected via plenum box ATTC KGEZ CTPB Size ØD1 ØD2 U G min G max ØU 125 99,3 125 135 2 2 135 160 124,3 160 170 2 2 170 Air diffuser connected directly to the duct Material and surface finish Air diffuser CTPB is made from hot-dip galvanized steel sheet and meets the requirements for corrosivity class C2 in accordance with SS-EN ISO 12944-2. The diffusers are powder-coated for a high surface finish and good impact and scratch resistance. Standard colour White RAL-90. Other colours on request. The plenum box is supplied as standard in hot-dip galvanized steel sheet. Technical data and dimensioning For complete dimensioning details, please see Fläkt Woods product selection program. Contact our nearest sales office for further information. Descriptive text Air diffuser CTPB manufactured by Fläkt Woods, for example in size 125, with a plenum box with a removable damper and mounting ring. Product code Ceiling diffuser CTPB-aaa KGEZ Size connection dimension in mm 125, 160 Plenum box 1) ATTC-aaa-bbb-c Application and function CTPB CTPB is a quiet 1-way air diffuser, which is normally positioned in a ceiling, although it can also be positioned on a wall. The air gap is variable, and the desired diffusion direction can be set by rotating the diffuser. The diffuser is easy to install with clamps to the valve frame and is easy to keep clean thanks to its large, smooth surfaces. CTPB is available in two sizes, with connections 125 and 160. The diffuser is also shown with plenum box ATTC. The plenum box ATTC has a combined measurement and adjustment damper with very low noise generation. The patented multipoint measuring of the measurement and adjustment damper enables balanced and accurate values. The measurement and adjustment damper can be easily dismantled for inspection and cleaning without changing the setting of the damper. The plenum box is insulated or uninsulated and its air tightness class is C. Size 0 125, 125 160 Connection dimension in mm to duct (aaa) Connection dimension in mm to diffuser (bbb) Type (c) 0 = uninsulated 4 = marine insulated Mounting ring - insertion connection Mounting ring - fit-on connection Size 125, 160 KGEZ-01-bbb KGEZ-05-bbb 1) For a complete supply, mounting ring KGEZ-01 must be ordered for plenum box ATTC. Fläkt Woods EN 14.05 All rights reserved.

Diffusers New shape, Higher quality, Easier to install than ever! www.flaktwoods.com

Marine Catalogue CTUR Air diffuser 81 CTUR air diffuser is especially well-suited for installation in galleys, istitutional kitchens and in laboratories in which the hygienic requirements and the demands on corrosion resistance are high. The CTUR is also suitable for use in comfort environments in which unique design solutions are important. The air diffuser is completely made of stainless steel and has, in all respects, the same appearance as diffusers with plenum box ATTC. The CTUR has smooth surfaces both inside and out, and has no sharp edges. These features make the air diffuser very easy to clean. The air diffuser is available in two versions with or without rim bolt nuts and six sizes for air flows up to and including 1 l/s and is available with connection diameter ranging from 125 mm up to 0 mm. The CTUR can be connected dirctly to the ducting or across a plenum box. Product facts High sound attenuation Easy to install Made of stainless steel Product code example: Air diffuser CTUR-125-0 Plenum box ATTC-0-125-4 Fläkt Woods EN 14.05 All rights reserved.

CTUR Made of stainless steel Easy to install High sound attenuation Hygienic www.flaktwoods.com

Marine Catalogue CTUR Air diffuser 83 Air flow, zone length, throw, pressure drop, sound level q, m 3 /h 80 0 0 0 00 The ATTC plenum box is used for connection to horizontal circular ducts. The ATTC plenum box has internal anti-condensation insulation on all sides. Plenum box Throw, m 5 2 Zone length, m 5 2 125 160 0 2 315-0 1 1 0 0 0 q, l/s 35 Air diffuser p t, Pa 125 160 0 2 315 0 5 0 0 2 q, l/s 0 25 L A, db (A) p m The air diffuser is normally supplied preset for 4-way diffusion however it can be easily modified for other air diffusion patterns. Design The visible parts of the diffuser consists of two concentric discs. The upper disc has a connection spigot fitted with a seal. The diffuser is normally used together with the ATTC plenum box. However it can also be connected directly to the duct. Materials and finish Diffuser: Stainless steel SS 2333. Connection box: Galvanised sheet steel. Packaging Diffuser: Carton and shrink-film packaging. Plenum box: Carton or shrink-film packaging, if larger quantities are delivered. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 84 CTUR Air diffuser Dimensions All dimensions in mm. Installation air diffuser connected directly to the ducting ATTC ØD ØC ØD = ØD2 G CTUR (aaa) ATTC (aaa-bbb) A B C 1) D1 D2 E 1) F H min H max 125 0-125 2 2 1 99 124 90 190 215 260 160 0 2 315 0 0-160 125-160 125-0 160-0 160-2 0-2 0-315 2-315 2-0 315-0 275 275 370 370 470 470 570 570 570 570 2 2 3 3 4 4 5 5 5 5 165 165 5 2 255 255 3 3 5 5 99 124 124 159 159 199 199 249 149 314 159 159 199 199 249 249 314 314 399 399 90 90 90 90 90 90 90 90 90 90 235 235 3 3 4 4 5 5 5 5 215 215 215 2 2 290 290 3 3 5 260 260 260 295 295 335 335 385 385 4 0 315-0 600 700 6 314 499 90 5 5 4 With nuts 1) min measurement for cut-out when b = 1 or 2 2) when b = 1 or 2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue CTUR Air diffuser 85 Product code Air diffuser CTUR-aaa-b Size (aaa) connection diameter in mm: 125, 160, 0, 2, 315, 0, 0 Version (b) 0 = without nuts (G = 34 mm) 1 = with nuts (G = mm) 2 = with nuts (G = 0 mm) - only at size 0 Plenum box Duct connection in mm (aaa) Diffuser connection in mm (bbb) ATTC-aaa-bbb-c Type (c) 0 = uninsulated 4 = marine insulated Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 86 MCSA Air supply unit for the REGOVENT single duct system The air supply unit is a single duct unit and designed for ceiling mounting above the false ceiling. The air supply unit is intended for climate control in spaces onboard ship, such as cabins, offices, messes and utility spaces. The MCSA unit consists of an internally insulated casing with a throttling device for airflow control. The maximum and minimum airflow is adjustable with adjusting screws inside the unit. The MCSA units should be used together with a CTGA or a CTLM supply air diffuser. Product facts Provides good thermal comfort. Offers individual temperature control by manual or automatic adjustment of the supply air flow. Is available with electrical re-heater. Offers simple and quick installation and commissioning. The internal insulation satisfies the criteria of IMO Resolution A.799 (19) as well as IMO FTPC Part 1 for classification as non-combustible. Conforms to the provisions of IMO Resolution A.754 (18) for false ceilings with fire resistance rating B15. Satisfies the vibration and temperature requirements specified by Det Norske Veritas. Product code example: Air supply unit MCSA-2-1-0-00-0-1 Supply air diffuser CTGA-2-1-2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCSA Air supply unit 87 All MCSA units The MCSA unit is designed for ceiling mounting and consists of an internally insulated casing with a throttling device for airflow control. The MCSA unit with supply air diffuser with knob for manual control The maximum and minimum airflow is adjustable with adjusting screws inside the unit. The MCSA units should be used together with a CTGA or a CTLM supply air diffuser. The supply air diffusers are available with or without knob. Supply air diffusers with knob should be used together with units with manual control. Supply air diffusers without knob should be used with units for constant air volume, CAV, or controlled by electric or pneumatic actuator. All supply air diffusers have a bayonet mounting for fast and secure connection to the outlet of the unit. The pattern of diffusion of the supply air can be adjusted to suit the requirements, by blanking of 1, 2 or 3 directions of discharge. CTLM MCSA CTGA For the CTGA supply air diffuser, this is carried out by means of a CTGZ-01 cover strip for blanking off part of the perforated surface of the diffuser, and the CTGZ-02 edge-sealing gasket for blanking off the gap between the diffuser and the surface of the ceiling. The CTGA is delivered without cover strip or edge sealing gasket. On the CTLM supply air diffuser, blanking off is carried out by means of CTLZ-12-035 cover plates. The CTLM is delivered without cover plates. Supply air diffuser without knob for Constant Air Volume, CAV, or with electric or pneumatic actuator CTGA CTLM Supply air temperature at the unit outlet Maximum: C. Minimum: C below the room temperature. Minimum air flows The table below shows the minimum airflows that are allowed in versions with electrical re-heater Output kw Min airflow l/s 0,3 0,6 25 0,9 25 1,2 1,5 35 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 88 MCSA Air supply unit Air supply unit with manual control The supply airflow can be adjusted manually by means of a knob in the diffuser. Supply air Air supply unit designed for automatic control with an electric actuator The airflow is controlled via an electrical actuator. The actuator is designed for 3-point control at 24V AC. The temperature in the cabin is controlled via a thermostat (not included in the MCSA) by changing the supply air via the electrical actuator Supply air Knob for airflow adjustment Supply air diffuser Actuator Air supply unit designed for manual control with an electric re-heater The supply airflow can be adjusted manually by means of a knob in the diffuser. The electric re-heater is designed for a 1V, 2V or 0V /60 Hz power supply. Other voltage supplies are available on request. The unit has two overheat thermostats, one of which must be reset manually, the other resets automatically when the heater has cooled down. Supply air Electric reheater Cabin thermostat (not included in the MCSA) Ceiling CTGA or CTLM air diffuser Air supply unit designed for automatic control with an electric actuator and an electric re-heater The airflow is controlled via an electrical actuator. The actuator is designed for 3-point control at 24V AC. The temperature in the cabin is controlled via a thermostat (not included in the MCSA) by changing the supply air via the electrical actuator and the output of the electrical re-heater. The electric re-heater is designed for a 1V, 2V or 0V /60 Hz power supply. Other voltage supplies are available on request. The unit has two overheat thermostats, one of which must be reset manually, the other resets automatically when the heater has cooled down. Knob for airflow adjustment Supply air diffuser Supply air Actuator Electric reheater Controller (not included in the MCSA) Cabin thermostat (not included in the MCSA) Ceiling CTGA or CTLM air diffuser Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCSA Air supply unit 89 Charts The charts are applicable under the following conditions: Total pressure drop: At an air density of 1.2 kg/m 3. Sound level: Flow-generated sound, db(a). The specified sound levels are applicable at a room attenuation of 4 db, which corresponds to the at tenu ation in a room with an equivalent sound absorption area of m 2. The specified sound levels are subject to a tolerance of ± 2 db. Zone length Zone length is the distance between the air supply unit and the wall, or half the distance between two adjacent units. All particulars are applicable to a unit with four-way diffusion. MCSA size 2, without electrical re-heater, with supply air diffuser CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 MCSA size 2, with electrical re-heater and supply air diffuser CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 Total pressure drop, Pa 0 0 0 0 45 Sound level, db(a) 1 35 60 70 80 Airflow, l/s Total pressure drop, Pa 0 0 0 0 45 Sound level, db(a) 1 35 60 70 80 Airflow, l/s MCSA size 3, without electrical re-heater, with supply air diffuser CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 MCSA size 3, with electrical re-heater and supply air diffuser CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 Total pressure drop, Pa 0 0 0 0 1 25 35 25 60 70 80 90 0 Airflow, l/s 45 Sound level, db(a) Total pressure drop, Pa 0 0 0 45 0 1 35 25 60 70 80 90 0 Airflow, l/s Sound level, db(a) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 90 MCSA Air supply unit Sound power level The sound power level L w in db can be calculated by adding the correction value K oct to the value of L A obtained from the charts on previous page in ac cord ance with the following formula: L w = L A + K oct K oct is a mean value for the entire normal operating range. MCSA-a-2-0-00-0-1 Air supply unit designed for automatic control with an electric motor-driven actuator for three-position control. The 24 V cable from the cabin thermostat must be connected to the plug connector supplied. The plug connector is located at the inlet end wall of the unit. Operate the actuators only on safety extra-low voltage AC 24 V (SELV). The damper will open to maximum cold airflow Size Electrical re-heater Correction values K oct, db Octave band, mid-frequency, Hz 63 125 2 0 00 00 00 8000 2 without 6 14 8 2-6 - -16-22 3 without 5 12 6 1-1 -8-16 -22 2 with 4 11 7 2-4 -11-17 -23 3 with 3 9 6 2-2 - -17-23 Air supply unit MCSA BK (Black) BU (Blue) BR (Brown) Y1 G Y2 24 V (SELV) Sound attenuation The specified sound attenuation is the reduction in the sound power level between the duct and the room. Size Sound attenuation, db Octave band, mid-frequency, Hz 63 125 2 0 00 00 00 8000 2 22 19 19 26 25 21 23 3 17 18 19 24 23 19 21 Wiring diagram MCSA-a-1-0-dd-2-1 (dd should not be 0) Air supply unit designed for manual control with an electric re-heater Air supply unit MCSA 1 1. Electrical re-heater element 2 3 2. Manually reset overheat protection 3. Automatic reset overheat protection 4. Interlocking of airflow (fan) with pressure switch. 5. Room thermostat. Not included in the MCSA unit. L 0 4 5 L 0 The damper will close to minimum cold airflow Air supply unit MCSA BK (Black) BU (Blue) BR (Brown) MCSA-a-2-0-dd-2-1 (dd should not be 0) Air supply unit designed for automatic control with an electric actuator and an electric re-heater. See wiring diagram and function above. Materials and finish Casing: Galvanised sheet steel, aluminium on request Throttling device: PVC-coated felt Control mechanism: Galvanised steel, brass and nylon. Insulation: Glass wool panels, with the exposed side covered with glass fibre fabric. Electric re-heater element: Stainless steel. Supply air diffuser: Galvanised sheet steel, powder painted white with colour NCS 02-Y-08-R (which corresponds to RAL90, BS 00 EE 55 and Munsell N 95, gloss %). Knob: Grey ABS plastic Swing down door and frame: Galvanised sheet steel, powder painted white with colour NCS 02-Y-08-R (which corresponds to RAL90, BS 00 EE 55 and Munsell N 95, gloss %). Packaging Y1 G Y2 The MCSA is delivered on a pallet, with common cardboard packaging. The CTGA and CTLM are delivered in cartons. 24 V (SELV) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCSA Air supply unit 91 Dimensions and weights SIze A B C D1 D2 E F All dimensions in mm. 2 425 425 180 99,3 2 132 158 3 495 495 180 124,3 2 169 2 F 4 425 425 180 79,3 0 132 158 Weight, kg Size a b c d CTGA CTLM 2, 4 6,5 7,2 7,5 8,2 1,3 1,6 ØD1 ØD2 II 3 8,5 9,2 9,5,2 1,3 1,6 a = Versions without actuator and re-heater b = Versions with actuator c = Versions with re-heater d = Versions with actuator and re-heater II Swing down door and frame: 4,5 kg 24 VAC Plug contact (only versions with electric actuator) 32 B 2 VAC connection (only versions with electric re-heater) A E 84 C Min Max 75 Example of installation in the space above the false ceiling Self-tapping screws CTGA air diffuser (View A) Knob for manual controlled air flow only Not included in the MCSA unit Size A 2,3 3 4 260 ØE +5 0 Dia. of opening in the ceiling 70-75 A 4 View A CTLM air diffuser 70 CTGA Ceiling CTLM -75 Ceiling Size ØE 2,3 255 4 5 A 25 Size A 2,3 352 4 275 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 92 MCSA Air supply unit Specification Air supply unit Size (a) 2 = Ø2 6 = Aluminium* 3 = Ø2 7 = Aluminium* 4 = Ø0 Control - airflow (b) 0 = CAV, constant air volume without knob 1 = manual with knob 2 = electrical 4 = electrical (modbus) 5 = pneumatic* MCSA-a-b-c-dd-e-f Supply air diffuser (to be ordered separately) Size (a) 1 = Ø0 2 = Ø2 CTGA-a-b-2 CTLM-a-b-1 Version (b) 1 = with knob for MCSA with manual airflow 3 = without knob for MCSA with CAV and/or electric or pneumatic motor Suspension (c) 0 = without 1 = with U-brackets (as shock proof) 2 = with L-brackets 3 = swing down door, frame fitted 4 = swing down door, frame delivered separate as accessory Heating coil, effect (dd) 00 = without heating coil 03 = 0,3 kw (only where a=2, 4) 06 = 0,6 kw 09 = 0,9 kw 12 = 1,2 kw 15 = 1,5 kw (only where a =3, 5) Current (e) 0 = without heating coil Offshore 1 = 1 V 7 = 1 V 2 = 2 V 8 = 2 V 4 = 0 V 9 = 0 V Options (f) 1 = standard 2 = pressure switch for fan interlocking (not Offshore) for the CTGA Cover strip set, 5 2 m Edge-sealing gasket set, 5 2 m Spare part kit Contents: Control knob, shaft & signs Set of pcs Spare part kit Contents: Driving gear wheels Set of pcs for the CTLM Cover plate set, for one discharge side CTGZ-01 CTGZ-02 CTGA-99-01 CTGA-99-02 CTLZ-12-035 MCSZ-aa (aa) 01 = suspension profile, swing down 02 = swing down frame 03 = swing down door with frame fitted the above are accessories for separate delivery *) On request Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCDA Air supply unit for the DUOVENT dual duct system 93 The air supply unit MCDA is a dual duct unit and designed for ceiling mounting above the false ceiling. The air supply unit is intended for climate control in spaces onboard ship, such as cabins, offices, messes and utility spaces. The MCDA unit consists of an internally insulated casing with two throttling devices for controlling the cold and warm air. The two airflows are mixed in the unit before being discharged through a supply air diffuser. The MCDA units should be used together with a CTGA or a CTLM supply air diffuser. Product facts Provides good thermal comfort. Offers individual temperature control of both the supply air temperature and the supply air flow. Is available for manual or automatic control by means of a pneumatic or electric motor. Offers simple and quick installation and commissioning. The internal insulation satisfies the criteria of IMO Resolution A.799 (19) as well as IMO FTPC Part 1 for classification as non-combustible. Conforms to the provisions of IMO Resolution A.754 (18) for false ceilings with fire resistance rating B15. Product code example: Air supply unit MCDA-2-2-0-1 Supply air diffuser CTGA-2-3-2 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 94 MCDA Air supply unit All MCDA units The MCDA unit is designed for ceiling mounting and consists of an internally insulated casing with two throttling devices for controlling the cold and warm air. The two airflows are mixed in the unit before being discharged through a supply air diffuser. The MCDA units should be used together with a CTGA or a CTLM supply air diffuser The supply air diffusers exist with or without knob. Supply air diffusers with knob should be used together with units with manual control. Supply air diffusers without knob should be used with units controlled by an electric or pneumatic actuator. All supply air diffusers have a bayonet mounting for fast and secure connection to the outlet of the unit. The pattern of diffusion of the supply air can be adjusted to suit the requirements, by blanking of 1, 2 or 3 directions of discharge. For the CTGA supply air diffuser, this is carried out by means of a CTGZ-01 cover strip for blanking of part of the perforated surface of the diffuser, and the CTGZ-02 edge-sealing gasket for blanking of the gap between the diffuser and the surface of the ceiling. The CTGA is delivered without cover strip or edge sealing gasket. On the CTLM supply air diffuser, blanking off is carried out by means of CTLZ-12-035 cover plates. The CTLM is delivered without cover plates. The MCDA unit with supply air diffuser with knob for manual control CTLM Supply air diffuser without knob for electrical or pneumatic control MCDA CTGA CTGA CTLM Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCDA Air supply unit 95 Air supply unit designed for manual control The mix of the cold and the warm supply airflow can be adjusted manually by means of a knob in the diffuser. Operation The MCDA can be preset and employed for either constant or variable total airflow, as shown in the charts below. Cold air Warm air Air flow Cold air Warm air Knob for airflow adjustment Ceiling CTGA or CTLM air diffuser Cold air setting Warm air setting Variable supply air flow Air supply unit designed for automatic control with an electric actuator The mix of the cold and the warm supply airflow is controlled via an electrical actuator. The actuator is designed for 3-point control at 24V AC. The temperature in the cabin is controlled via a thermostat (not included in the MCDA) by changing the mix of the cold and the warm supply air flow via the electrical actuator. Air supply unit designed for automatic control can also be equipped with a pneumatic actuator instead of an electric actuator. Constant supply air flow Cold air setting Cold air Warm air Warm air setting Air flow Supply air temperature at the unit outlet Maximum: C. Minimum: C below the room temperature. Cold air Warm air Actuator Cabin thermostat (not included in the MCDA) Ceiling CTGA or CTLM air diffuser Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 96 MCDA Air supply unit Charts The charts are applicable under the following conditions: Total pressure drop: At an air density of 1.2 kg/m 3. Sound level: Flow-generated sound, db(a). The specified sound levels are applicable at a room attenuation of 4 db, which corresponds to the at tenu ation in a room with an equivalent sound absorption area of m 2. The specified sound levels are subject to a tolerance of ± 2 db. Zone length Zone length is the distance between the air supply unit and the wall, or half the distance between two adjacent units. All particulars are applicable to a unit with four-way diffusion. MCDA size 2, Cold air with CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 MCDA size 2, Warm air with CTGA or CTLM 00 Total pressure drop, Pa 0 0 0 0 45 Sound level, db(a) 1 35 60 70 80 Airflow, l/s Total pressure drop, Pa 0 45 0 0 35 0 1 60 Airflow, l/s Sound level, db(a) MCDA size 3, Cold air with CTGA or CTLM Zone length, m 0,6 1,0 2,0 00 MCDA size 3, Warm air with CTGA or CTLM 00 Total pressure drop, Pa 0 0 0 0 45 Sound level, db(a) 1 25 35 25 60 70 80 90 0 Airflow, l/s Total pressure drop, Pa 45 0 0 0 0 35 Sound level, db(a) 1 25 25 60 Airflow, l/s Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCDA Air supply unit 97 Sound power level The sound power level L w in db can be calculated by adding the correction value K oct to the value of L A obtained from the charts on previous page in ac cord ance with the following formula: The damper will close to minimum cold airflow Air supply unit MCDA BK (Black) Y1 BU (Blue) G BR (Brown) 24 V (SELV) Y2 L w = L A + K oct K oct is a mean value for the entire normal operating range. Size Correction values K oct, db Octave band, mid-frequency, Hz 63 125 2 0 00 00 00 8000 2 6 14 8 2-6 - -16-22 3 5 12 6 1-1 -8-16 -22 Sound attenuation The specified sound attenuation is the reduction in the sound power level between the duct and the room. Size Sound attenuation, db Octave band, mid-frequency, Hz 63 125 2 0 00 00 00 8000 2 22 19 19 26 25 21 23 3 17 18 19 24 23 19 21 Wiring diagram MCDA-a-2-0-1 Air supply unit designed for automatic control with an electric motor-driven actuator for three-position control. The 24 V cable from the cabin thermostat must be connected to the plug connector supplied. The plug connector is located at the inlet end wall of the unit. Operate the actuators only on safety extra-low vol-tage AC 24V (SELV) MCDA-a-3-0-1 Air supply unit designed for automatic control with a pneumatic motor-driven actuator. The damper will open to maximum cold airflow at a air control pressure of 0,2 bar and close to minimum cold air flow at air pressure of 1,2 bar. Materials and finish Casing: Galvanised sheet steel Throttling device: PVC-coated felt Control mechanism: Galvanised steel, brass and nylon. Insulation: Glass wool panels, with the exposed side covered with glass fibre fabric. Supply air diffuser: Galvanised sheet steel, powder painted white with colour RAL90. Knob: Grey ABS plastic Packaging The MCDA is delivered on a pallet, with common cardboard packaging. The CTGA and CTLM are delivered in cartons. The damper will open to maximum cold airflow Air supply unit MCDA BK (Black) BU (Blue) BR (Brown) Y1 G Y2 24 V (SELV) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 98 MCDA Air supply unit Dimensions and weights All dimensions in mm. SIze A B C D1 D2 E F 2 425 425 180 99,3 2 132 158 F 3 495 495 180 124,3 2 169 2 4 425 425 180 79,3 0 132 158 Weight, kg Cold air ØD1 ØD2 Warm air Ø79,3 II Size a b CTGA CTLM 2, 4 7,0 7,6 1,3 1,6 3 9,0 9,6 1,3 1,6 II a = Versions without actuator b = Versions with actuator 24 VAC Plug contact (only versions with electric actuator) 32 B 98 A E 84 C Min Max 75 Example of installation in the space above the false ceiling Self-tapping screws CTGA air diffuser (View A) Knob for manual controlled air flow only Not included in the MCSA unit Size A 2,3 3 4 260 A 4 ØE +5 0 Dia. of opening in the ceiling 70-75 View A CTLM air diffuser 70 CTGA Ceiling CTLM -75 Ceiling Size ØE 2,3 255 4 5 A 25 Size A 2,3 352 4 275 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue MCDA Air supply unit 99 Specification Air supply unit Size (a) 2 = Ø2 6 = Aluminium* 3 = Ø2 7 = Aluminium* 4 = Ø0 Control - airflow (b) 1 = manual with knob 2 = electrical 4 = electrical (modbus) 5 = pneumatic* MCDA-a-b-c-d Suspension (c) 0 = without 1 = with U-brackets (as shock proof) 2 = with L-brackets 3 = swing down door, frame fitted 4 = swing down door, frame delivered separate as accessory Supply air diffuser (to be ordered separately) Size (a) 1 = Ø0 2 = Ø2 Version (b) 2 = with knob for MCDA with manual airflow 3 = without knob for MCDA with electric or pneumatic motor for the CTGA Cover strip set, 5 2 m Edge-sealing gasket set, 5 2 m Spare part kit Contents: Control knob, shaft & signs Set of pcs CTGA-a-b-2 CTLM-a-b-1 CTGZ-01 CTGZ-02 CTGA-99-01 Options (d) 1 = standard (aa) 01 = suspension profile, swing down 02 = swing down frame 03 = swing down door, frame fitted the above are accessories for separate delivery MCSZ-aa Spare part kit Contents: Driving gear wheels Set of pcs for the CTLM Cover plate set, for one discharge side CTGA-99-02 CTLZ-12-035 *) On request Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 0 KGEB Exhaust valve The KGEB exhaust valve is suitable for use in mechanical ventilation systems. The valve can be wall mounted or ceiling mounted and its air flow is simple to adjust. The KGEB has a low noise level, even if the pressure drop is high, and it has good natural sound attenuation. Quick selection Size KGEB-0 KGEB-125 KGEB-160 Connection alternative T-piece Mounting ring Angle duct T-piece Mounting ring Angle duct T-piece Mounting ring Air flow l/s (m 3 /h) at sound level 25 db db 35 db 16 14 22 29 16 42 47 19 24 16 25 34 55 (68) (86) (58) (90) (122) (72) (180) (198) 23 27 19 28 38 23 58 64 Product facts Low noise level, even if the pressure drop is high Good natural sound attenuation Both for new installation and renovation Manufactured of steel Product code example: Exhaust valve KGEB-0-C Mounting frame KGEZ- Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue KGEB Exhaust valve 1 Size 0 with T-piece Δp t, Pa 0 0 0 b = -14 25 3 4 5-12 -9 q, l/s -6 Size 0 with mounting ring Δp t, Pa 0 0 0 b = -14 Size 0 with angle duct Δp t, Pa Size 125 with T-piece 0 +6 35 LA, db (A) 25 3 4 5 0 0 0-12 -12 b = -14-9 q, l/s -6 0 +6 35 LA, db (A) 25 3 5 0 q, l/s -9-6 0 +6 35 LA, db (A) Size 125 with mounting ring Δp t, Pa 0 0 0 b = -22 5 25-18 q, l/s Size 125 with angle duct Δp t, Pa 0 0 0 b = -22 Size 160 with T-piece Δp t, Pa -12-6 Size 160 with mounting ring 0 +6 35 LA, db (A) 25 35 5 q, l/s 0 0 0-18 -12-6 0 +6 45 LA, db (A) 25 0 0 b = -24-18 q, l/s -12-6 0 +6 45 35 LA, db (A) 0 0 45 Δp t, Pa 0 b = -22 35 25 5-18 q, l/s -12-6 0 +6 45 LA, db (A) Δp t, Pa 0 b = -24-18 -12-6 0 +6 25 0 q, l/s 35 LA, db (A) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 2 KGEB Exhaust valve Sound power level Angle duct KGEZ-43 KGEB Correction of sound level (db) at 63 125 2 0 00 00 00 8000 0 6 5 1-2 -4-7 -12 125 17 2 3-1 -1-4 -8-12 160 18 4 3 0 1-4 -12-14 EXT. ØD2 B Sound attenuation Connection KGEB fitting KGEZ-01-0 0 KGEZ-05-0 KGEZ-43-0 KGEZ-01-125 125 KGEZ-05-125 KGEZ-43-125 160 KGEZ-01-160 KGEZ-05-160 Dimensions and weights Exhaust valve KGEB ØA Sound attenuation (db) at 63 125 2 0 00 00 00 8000 25 22 21 14 18 9 25 22 21 14 18 9 27 23 17 16 19 12 13 24 24 29 22 22 25 18 18 17 17 19 16 16 15 15 12 12 12 11 11 13 14 14 12 12 13 B 7 7 9 9 7 7 8 8 C ØD1 A Size A B C D 1 D 2 Weight, kg 0-080 1 39 148 125 79,3 0,4 0-0 1 39 98 125 99,3 0,4 125-080 115 36 161,5 131 79,3 0,35 125-0 146 45 1 1 99,3 0,5 Mounting frame KGEZ-12 Holes Ø 4 mm 15 mm from the edges 0 Size A B Weight, kg 0 1 45 0,3 125 155 56 0,4 160 190 65 0,6 Mounting ring KGEZ-01, insertion conn. / Mounting ring KGEZ-05, fit-on conn. ØA 15 44 46 Used to replace earlier types of valves by KGEB-0 and KGEB-125 respectively. Mounting frame KGEZ- ØD 180 Size D Weight, kg 0 0 0,2 125 125 0,2 Seal Spring EXT. ØD 1 INT. ØD2 180 KGEZ-01 KGEZ-05 Size A D 1 D 2 Weight, kg Hole size 0 123 99,3 0 0, Ø1 125 149 124,3 125 0, Ø135 160 185 159,3 160 0,16 Ø170 53 Weight 0,3 kg Ø0 Used when old KGD valves are replaced with KGEB-0 or KGFC-1-0. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue KGEB Exhaust valve 3 Installation, adjustment and maintenance Instructions for installation, adjustment and maintenance are described in detail in our technical instructions, also available on the Internet at: www.flaktwoods.com. Valve KGEB connected to a mounting ring KGEZ-05 KGEB Valve KGEB connected to an angle duct Application The KGEB exhaust valve is suitable for use in all type of air treatment installation. The valve can be wall or ceiling mounted and the air flow is easy to adjust. KGEB has a low noise level, even if the pressure drop is high, and it has good natural sound attenuation. The valve has accessories adapted to different kinds of installations. Exhaust valves in sizes 125 and 160 fit renovationconstructions in older KGEZ-branches in equivalent sizes. Material and surface finish The valve is manufactured from hot galvanized steel sheet. The grille is powder coated for a high surface finish and good impact and scratch resistance. Standard colour White RAL-90. CleanVent coating as standard.. 0 125 160 Packing KGEZ-43 KGEB Delivery in cartons containing pc. q = k p m (l/s) (Pa) b -11-9 -6 0 +6 +9 k-factor 0,39 0,56 0,82 1,36 1,9 2,2 b -22-18 -12-6 0 +6 k-factor 0,88 1,3 1,8 2,4 2,9 3,4 b -24-18 -12-6 0 +6 k-factor 1,8 2,5 3,1 3,9 4,6 5,4 * Applicable for KGEB produced after 01.01.03 b b b Technical data and dimensioning For complete dimensioning details, please see Fläkt Woods product selection program. Contact our nearest sales office for further information. Descriptive text KGEB exhaust valve manufactured by Fläkt Woods in size, with fit-on type mounting ring/insertion type mounting ring/angle duct. Product code Exhaust valve KGEB-aaa-C Size 0, 125, 160 Mounting ring - insertion connection KGEZ-01-bbb Size 0, 125, 160 Mounting ring - fit-on connection KGEZ-05-bbb Size 0, 125, 160 Mounting frame KGEZ-12-bbb Size 0, 125 Mounting frame (for KGD-frames) KGEZ- Angle duct KGEZ-43-bbb-ccc Size Connection dimension in mm to valve to duct: 0 080, 0 0, 125-080, 125 0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 4 SV2, SV1 Grilles SV1 SV2 SV2 and SV1 grilles are designed for use as supply air devices for e.g. in offices and commercial premises. They are also suitable for exhaust and transfer air and have adjustable spread patterns and throws. The grilles which are intended for mounting on a wall or in the ceiling, can be completed with mounting frame K or connection box TG/TGE, which has a silent measurement damper. As accessory there is also adjusting device S which makes it possible to adjust the air flow. Quick selection supply air without connection box Grille model Air flow range l/s (m 3 /h) at sound level 25 db(a) db(a) 35 db(a) SVn-aaaa-0 58-2 77-280 (277-08) 95-3 SVn-aaaa-1 0-0 1-390 (468-14) 160-490 SVn-aaaa-0 1-360 160-470 (576-1692) 0-580 SVn-aaaa-0 2-460 290-600 (44-2160) 360-7 SVn-aaaa-0 4-6 5-8 (1980-60) 700-10 Product facts Low sound level Can be mounted without mounting frame Easy to adjust Product code example: Grille SV2-00-0 Connection box supply air TG-00-0-A Connection box exhaust air TGE-00-0-B Mounting frame K-00-0 Adjusting device S-00-0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SV2, SV1 Grilles 5 Air flow, pressure drop, sound level α q v (l/s) α k α L α (1 l/s = 3,6 m 3 /h) p t (Pa) L 0,2 (m) L pa [db(a)] L 0,3 ~ 0,67 x L 0,2 Height Korkeus H (mm) Width Leveys W B (mm) B b b 0,25 x L 0,2 α = 0 b 0,6 x L 0,2 α = 45 b 0,7 x L 0,2 α = 60 b 1,2 x L 0,2 α = 90 L 0,2 Exhaust air H 0 h h 0,06 x L 0,2 t = 0 C The diagrams are valid for supply air. When used for exhaust air the sound level grows approx. 5 db and the pressure drop falls with %. Supply air H 800 L 0,2 free vapaa-asennus mounting L 0,2V = 0,7 x L 0,2 h h 0,1 x L 0,2 t = 0 C When using chilled air, recommended height H is 0 mm and max chilled air Δt = approx. -5 C. Increase in sound level and pressure drop caused by back blades: L pa(tot) = L pa + L α p t(tot) = K α x p t When connection box TG or TGE is used, see acoustical and pressure data for each product Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 6 SV2, SV1 Grilles Dimensions Grille SV2 Grille SV1 Adjusting device S, exhaust air open 22 22 (H+24) x (B+24) H x B (H+24) x (B+24) H x B Mounting frame K SV-1 Adjusting device S 47 12 (H 4) x (B 4) For dimensions H and W see heading Dimensioning on previous page. (H 17) x (B 17) Adjusting device S, supply air (H 12) x (B 12) Total sound level of grille and adjusting device: Difference of sound levels between grille and adjus ting device Addition to the higher sound pressure level Calculation example 0-1 2-3 4-9 db 3 2 1 0 db 1. The required isothermal supply air q v to room is 0 l/s. 2. Throw suitable for the size of the room is L 0,2 ~ 8 m. 3. Required sound pressure level in the room L pa = db(a). 4. Ensure that the duct system can be adjusted. open Solution: 1. SV2-600-0 is selected. 2. With angle α = 60 o of the back blades is L 0,2 ~ 8 m, L pa(tot) + 6 = 26 db(a) and p t(tot) ~ 2 x 2 = 4 Pa. 3. Allowed sound pressure level L pa, paying attention to the real room attenuation, the influence of the number of supply and exhaust devices etc., is f.ex. 44 db(a). 4. When using the adjusting device S the adjustment is: 0,2 m 3 /s v k = ~ 1,7 m/s ; A k = 0,12 m 2 0,6 x 0,2 m 2 K A = +8 db Sound level of adjusting device: L pas = L pa + K A Velocity of the face area: vk = q v B x H [ ] m 3 /s Influence of the face area (A k ) to the sound pressure level: A k = B x H 0,03 0,06 0,12 0,2 0,4 m 2 K A ±0 +3 +8 +11 +15 db m 2 Allowed sound pressure L pa = 44 8 = 36 db(a). Difference of sound pressure levels of the grille and adjusting device = 36 26 db (the grille does not raise the total sound pressure level in this case). The adjustment range achieved with the adjusting device p t ~ 35 Pa. The adjustment range achieved with connection box TG is 0 Pa in this case. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue SV2, SV1 Grilles 7 Construction Product code SV2: horizontal, directional front blades (flow pattern can be steplessly directed upwards and downwards) and vertical directional back blades (flow pattern and throw can be regulated steplessly Grille (supply, exhaust, transfer air) Width, mm Height, mm SV2-aaaa-bbb SV1-aaaa-bbb SV1: horizontal, directional front blades (exhaust air use) Grilles, larger than width W>00 and/or height H> are available with modular construction. In case of modular construction the dimensions of the installation hole (WxH in mm) should be stated. Max. height of the adjusting device S is 600 mm. Adjusting devices, larger than width W>600 are available with modular construction. Grille with mounting frame Width, mm Height, mm Mounting frame installed SV2-aaaa-bbb-K SV1-aaaa-bbb-K Material and surface finish The grilles are manufactured from aluminium profiles. Mounting frame K and adjusting device S are manufactured from hot galvanized sheet steel. The regulation blades are manufactured from aluminium. The devices are powder coated for a high surface finish and good impact and scratch resistance. Connection box supply air Connection box exhaust air Length of grille connection, mm Height of grille connection, mm TG-aaaa-bbb-c TGE-aaaa-bbb-c Standard colour white RAL-90, gloss 70. Other colours on request. Installation The grilles are fitted into mounting frame K or connection box TG with springs or screwed directly on the wall or ceiling. If the grille is screwed on the ceiling, this should be stated in the order. The springs are ready in all sizes, screw holes in sizes W>600 mm or H>0 mm. If screw holes are needed for a smaller grille, this should be stated in the order. Connection alternative A = from the side B = from the rear C = from above / from below Mounting frame Size, grille Width in mm Height in mm K-aaaa-bbb Placement SV2 SV1 Wall, supply and exhaust Ceiling, supply and exhaust Instructions Instructions for installation, adjustment and maintenance are described in detail in our technical instructions also available on the internet at www.flaktwoods.com. Adjusting frame Size, grille Width in mm Height in mm S-aaaa-bbb Technical data and dimensioning For complete dimensioning, please see Fläkt Woods product selection program. This is applicable especially when connection box TG/TGE is in use because device and box is not accounted for in the catalogue material. Contact our nearest sales office for further information. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 8 USR Grille The grille USR is designed for use as exhaust air terminal device. It can be mounted into a wall or onto a ceiling. It may also be mounted into a connection box TGE. The adjusting device S is also available as an additional accessory. Quick selection exhaust air without connection box Size Connection TGE Air flow l/s (m 3 /h) at sound level (B - H) against duct, Ø mm 25 db(a) db(a) 35 db(a) USR-0-0 125 58 (9) 67 USR-0-0 160 85 98 (353) 1 USR-0-0 160 0 1 (432) 1 USR-0-0 0 1 1 (5) 170 USR-600-0 2 175 0 (7) 225 USR-800-0 2 2 2 (900) 290 USR-00-0 2 290 3 (1188) 375 USR-0-1 0 1 1 (5) 170 USR-0-1 2 175 0 (7) 225 USR-0-1 2 2 2 (900) 290 USR-600-1 2 2 280 (08) 3 USR-800-1 315 0 0 (14) 4 USR-00-1 315 480 480 (1728) 5 USR-0-0 2 2 280 (08) 3 USR-0-0 315 290 3 (1188) 375 USR-600-0 315 3 0 (14) 4 USR-800-0 315 4 480 (1728) 5 USR-00-0 315 0 580 (1980) 760 Product facts Designed for use as exhaust air terminal device With or without connection box Adjusting device as accessory Product code example: Grille USR-600-0 Connection box TGE-600-0-A Adjusting device S-600-0 Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue USR Grille 9 Selection diagram Dimensions and weights Size Storlek (WxH), (b x h), mm Squares Rutor 12,5 12,5 x 12,5 x 12,5 45 27 B Δp t, Pa 5 0-0 0-0 0-0 0-0, 0-1 q v, l/s 600-0, 0-1 Sound attenuation 800-0, 0-1 600-1, 0-0 00-0, 0-0 Grille without a connection box / check plate Sound attenuation L (db) Size Octave bands, mean frequency (Hz) 125 2 0 00 00 00 8000 0-0 6 2 - - - - 0-0 9 4 2 - - - - 0-0 8 4 1 - - - - 0-0 7 3 1 - - - - 600-0 6 3 1 - - - - 800-0 5 2 - - - - - 00-0 4 1 - - - - - 0-1 8 4 1 - - - - 0-1 7 3 1 - - - - 0-1 6 3 1 - - - - 600-1 5 2 - - - - - 800-1 4 1 - - - - - 00-1 3 1 - - - - - 0-0 5 2 - - - - - 0-0 5 2 - - - - - 600-0 4 1 - - - - - 800-0 3 1 - - - - - 00-0 3 1 - - - - - Tol. ± 3 2 2 2 2 2 3 800-1, 600-0 25 0 0 0 00 00 00-0 00-1, 800-0 35 L pa, db(a) A Size A B Weight, kg 0-0 221 0,36 0-0 321 0,45 0-0 421 0,54 0-0 521 121 0,63 600-0 621 0,72 800-0 821 0,90 00-0 21 1,09 0-1 321 0,53 0-1 421 0,63 0-1 521 0,74 171 600-1 621 0,85 800-1 821 1,06 00-1 21 1,27 0-0 421 0,72 0-0 521 0,85 600-0 621 221 0,97 800-0 821 1,21 00-0 21 1,46 Mounting frame K Adjusting device S 47 12 (H-4) x (B-4) (H-12) x (B-12) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 1 USR Grille Adjusting device S, exhaust air open Calculation example 1. The need for the air flow is 1 l/s. 2. The requirement for the sound attenuation of the room is L pa db(a). 4. Check that the ducts are adjustable. Solution: 1. Select the grille USR-600-0. 2. Calculate the permitted sound level L A in consideration of the actual room attenuation and other devices of the room, for example 44 db(a). 3. When using the adjusting device S it is to be calculated as follows: v k = 0,15 m 3 /s ~ 2,5 m/s ; A k = 0,06 m 2 0,6 x 0, m 2 K A = +3 db Sound level of adjusting device: L pas = L pa + K A Velocity of the face area: Influence of the face area (Ak) to the sound pressure level: A k = B x H 0,03 0,06 0,12 0,2 0,4 m 2 K A ±0 +3 +8 +11 +15 db vk = q v B x H [ ] m 3 /s m 2 Permitted sound level for the adjusting device is L A = 44 3 = 41 db(a). Sound level difference of the grille and adjusting device is 41 21 = db (in this case the grille doesn t increase the total sound level). The pressure control area when using the adjusting device S is p t = 35 Pa. Total sound level of grille and adjusting device: Difference of sound levels between grille and adjus ting device Addition to the higher sound pressure level 0-1 2-3 4-9 db 3 2 1 0 db Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue USR Grille 111 Construction The USR grille is designed for use as exhaust air terminal device. It can be mounted on a wall or in a ceiling. It may also be mounted into connection box TGE. The adjusting device S is also available as an additional accessory. USR has a frame and grid blades of fixed regulation blades. The dimensions of the installation hole (WxH in mm) are given with the order. The gradation of the grilles in width is 0 mm and in height mm, in the design of 0x0 to 00x0. Bigger sizes are also available. Grilles, larger than width W> and/or height H>600 are available with modular construction. Max. height of the adjusting device S is 600 mm. Adjusting devices, larger than width W>600 are available with modular construction. Material and surface finish The USR grilles (frame and grid blades) are manufactured from aluminium. The mounting frame K and the adjusting device S are manufactured from hot galvanized steel sheet. The regulation blades are manufactured from aluminium. The grille is powder coated for a high surface finish and good impact and scratch resistance. Standard colour is white, RAL-90, gloss. Installation The grille is fitted into a mounting frame K or into a connection box TGE by using springs (all sizes) or screw holes (sizes W 600 mm or H 0 mm). Product code Grille Width in mm Height in mm Connection box Length of grille connection, mm Height of grille connection, mm Connection alternative A = from the side B = from the rear C = from above / from below Mounting frame Width in mm Height in mm Adjusting device Width in mm Height in mm USR-aaaa-bbb TGE-aaaa-bbb-c K-aaaa-bbb S-aaaa-bbb Instructions Instructions for installation, adjustment and maintenance are described in detail in our technical instructions which are supplied with every product. The instructions are also available on the internet at www.flaktwoods.com. Technical data and dimensioning For complete dimensioning, please see Fläkt Woods product selection program. Contact our nearest sales office for further information. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 112 RIS External louvres General RIS external weather louvre of robust design for air intake and discharge. meets the requirements of standard EUROVENT 2/5 for water penetration, low pressure drop, well shaped to prevent particles from being built up, can easily be removed from the ventilation frame, genuine surface finish. Construction The RIS external louvre consists of louvre, installation frame and protective mesh. Large louvres are made as modul construction. Louvres can be continuous with active and non-active sections. RIS-aaa-bbb: General louvre for air intake or discharge. Minimum size for single louvre (width B x height H) is 0 x 0 mm and maximum is 1600 x mm. Larger louvres are made of moduls. Width and height can be supplied in mm increments. The actual size for fitting is 7 mm less than the nominal size. RIS-aaa-bbb-J: Outer grille for exhaust air. Same as RIS, but the louvres are formed especially for exhaust air and directed upwards. Exhaust air louvre is designed to be used in equipment for continuous operation. For equipment for intermittent operation, the recommended installation includes either a rain cover above the grille or a drain in the connecting duct, leading out the possibly accumulated water during standstill periods. RISD-aaa: Circular RIS-type louvre. Rigid construction. Sizes from ø 0 up to ø 10 mm as a single louvre ( mm increments). Larger louvres are made of moduls. RIS RISD RISV-aaa / RISV-aaa-J: Louvre assembled with circular Veloduct jointing collars supplied with rubber sealing gaskets. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RIS External louvres 113 Pressure drop RIS, RISD 0 The efficiency of rainwater rejection RIS, RISD 0 0 90 p t, (Pa) 70 5 3 C A D B 1 2 A B C D E (%) 80 70 60 2 0,3 0,5 1 2 3 4 5 7 v m (m/s) 1 = installed in duct 2 = application without duct 0 0 1 2 3 4 v m (m/s) 0 125 160 0 2 315 0 0 6 800 00 12 Pressure drop RISV Selection diagram p t, (Pa) 0 5 4 3 2 4 5 0 0 0 00 00 00 q v, (l/s) 2 v k (m/s) Pressure drop for RIS-aaa-bbbJ is half of pressure drop for RIS. Rainwater rejection performance and air flow performance characteristics are determined based on EN 1:01 Selection example Air volume q v = 2,3 m 3 /s, specified face velocity v m = 2 m/s. From above diagrams can be read pressure drop p t = 23 Pa and E = 76%. From selection diagram can be read the required face area A 0 = 1,2 m 2. Selection examples are RIS-10-10 or RIS--00 etc. 3 q v (m 3 /s) 5 3 2 1 0,5 0,3 0,2 0,1 0,1 Definitions vm = 4,0 m/s vm = 3,0 m/s vm = 2,5 m/s vm = 1,5 m/s vm = 1,0 m/s 0,2 0,3 vm = 2,0 m/s 0,5 1 A 0 (m 2 ) vm average velocity (m/s) pt total pressure drop (Pa) qv air flow (l/s) vk velocity in duct (m/s) E efficiency of rainwater rejection % 2 3 5 5 4 3 2 1 0,5 0,3 q v (00 m 3 /h) Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 114 RIS External louvres Dimensions RIS RISV B + 73 H + 73 (H - 7) x (B - 7) (H - 5) x (B - 5) ød - 1 70 19 70 19... RISD ød - 7 70 ød + 53...73 RISV Veloductjoint d 0 x 0 125 0 x 0 160 2 x 2 0 0 x 0 2 3 x 3 315 4 x 4 0 5 x 5 0 6 x 3 6 8 x 8 800 x 00 10 x 10 12 Material and surface finish Hot dip galvanized steel SFe (standard) Aluminium profile An (no surface treatment, anodized or stove enamelled) Acid proof steel Hst Model RISD is available in hot dip galvanized steel only. Standard colour is grey RAL 7000 (stove enamelled), other colours as special order. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue RIS External louvres 115 Installation The louvre frame is attached with screws on steel and wooden structure. On brick and concrete structures the louvre is fitted by means of fix arms in the frame. The assembly of the louvre is made according to the picture below. 4 1 Assembly frame Louvre 3 Wire mesh screen 2 Modular construction The modular construction is used when the dimension of the louvre exceeds the maximum dimension of a separate louvre. Fitting margin is the same as with a single louvre. Fläkt Woods EN 14.05 All rights reserved.

Marine Catalogue 116 RIS External louvres Product code Standard external louvre, hot dip galvanized steel RIS-aaa-bbb External louvre, aluminium profile RIS-aaa-bbb-A External louvre, acid proof steel RIS-aaa-bbb-H External louvre for exhaust air RIS-aaa-bbb-J Width, mm (aaa) Height, mm (bbb) Circular external louvre RISD-aaa Size, mm 0-10 External louvre with Veloduct joint RISV-aaa External louvre with Veloduct joint for exhaust air RISV-aaa-J Size, mm 125-12 Fläkt Woods EN 14.05 All rights reserved.

MCDA Air supply unit The air supply unit MCDA is a dual duct unit which provides good thermal comfort. The MCDA is simple to install and quick to comission. www.flaktwoods.com

We Bring Air to Life Photo copyright STX Finland Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide rande of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required functions and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for industry and infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for installation on walls, ceiling or floor are all included in our large range and fit all types of applications. Chilled Beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or flush-mounted ceiling installation - and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Residential ventilation A complete range of products for residential ventilation. Consists of ventilation units, exhaust air fans and cooker hoods designed to optimise indoor comfort and save energy. Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1800 kw. Designed to minimise annual energy consumption in all types of buildings. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Marine Application Technical data / EN / 05.14 / All rights reserved. Fläkt Woods representative: