General Precautions. Personnel Precautions

Similar documents
LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

Solar Charge Controller

SCC-MPPT Solar Charge Controller

AC CONVERTER / BATTERY CHARGER

USER MANUAL. GS Series Hybrid Inverter

IPS3000P 3KVA INVERTER / CHARGER. Version 1.00 (English) BEFORE GETTING STARTED

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

IPS5000 5KVA INVERTER / CHARGER. Version 1.00 (English) BEFORE GETTING STARTED

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PW Series Inverter / Charger

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

BRAVER UPS. (Uninterruptible Power System) User s Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

S150,S300 Series Pure Sine Wave Inverter User s Manual

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

AUTO CHARGE D PUMP PLUS

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Table of Contents 文管中心 發行章

PureSine 150/300 Pure Sine Wave Inverter User s Manual

PI1500X Power Inverter User s Manual

BATTERY CHARGER CHR-1445

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

IMPORTANT SAFETY INSTRUCTIONS

400 Watt Backup Power System Owner s Manual

PSJ-2212, PSJ-3612, PSJ-4424

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

MASTERsine Inverter PXA Series Installation Guide

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

CX-SERIES ADVANCED BATTERY CHARGER

PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

USER MANUAL. PSC Plus3K Series Hybrid Inverter

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Uninterruptible Power System

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Model: SE-4020-CA Automatic Battery Charger

User Manual 1KVA-5KVA INVERTER / CHARGER

BS20 BATTERY CHARGER For lead-acid batteries

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SP6. Automatic Battery Charger. Model

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Sentry Battery Charger. Installation and Operations Manual Section 75

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Go Power! Manual. GP-Smart Charger

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

BATTERY SAVER LOW RIPPLE HO

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Models: SP3, SPSS3 Automatic Battery Charger

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

MODEL 6017 OPERATOR'S MANUAL

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

GSL Electronics Modified Sine Wave Power Inverters

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

OPERATOR S MANUAL. Portable Power 950. Model No

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

INTELLIGENT BATTERY CHARGER/MAINTAINER

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Guardian Battery Charger Series. Installation and Operations Manual Section 75

PANcharge1k Battery Charger User's Manual

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

Pure Sine Wave Inverter Charger

User Manual 200Ah INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER

Power Inverter 400 MW Owner s Manual

Battery Enclosure Installation Instructions

Cruising Charger Series OWNER S MANUAL

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

LESTRONIC II BATTERY CHARGER MODEL 07210

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Transcription:

USER MANUAL

General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only lead-acid rechargeable batteries. Other types of batteries may cause damage and injury. 3. Do not expose Inverex to rain, snow or liquids of any type. Inverex is designed for indoor. 4. Do not disassemble Inverex. Take it to a qualified service center when service or repair is required. 5. WARNING: Provide ventilation to outdoors from the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. 6. NEVER charge a frozen battery. 7. Input/output AC wiring must be no less than 18 AWG gauge copper wire and rated for 75 o C or higher. Battery cables must be rated for 75 o C or higher and should be no less than 10AWG gauge. The inner diameter of the copper ring terminal which is used to connect battery cables to Inverex DC terminals should be no less than 6mm. 8. Be extra cautious when working with metal tools around batteries. Short-circuiting the batteries could cause an explosion. 9. Read the battery manufacturer s installation and maintenance instructions prior to operating. Personnel Precautions 1. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 2. Avoid touching eyes while working near batteries. 3. NEVER smoke or allow a spark or flame in vicinity of a battery. 4. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. Batteries can produce a short-circuit current high enough to make metal melt, and could cause severe burns. 5. If a remote or automatic generator start system is used, disable the automatic starting circuit or disconnect the generator to prevent accident during servicing.

Introduction Inverex is a DC-to-AC inverter with auto line-to-battery transfer and integrated charging system, serving as an extended run UPS, a standalone power source or an automotive inverter. Inverex supplies power from AC power and DC source. When AC cable is connected to a wall socket, utility power goes to connected equipment(s) and/or charges the battery set via charging system. In UPS mode, Inverex automatically convert battery energy into AC power for backing up the connected devices. Features: Automatic line-to-battery switchover Selectable Input voltage ranges High efficient DC-to-AC conversion, minimizing energy loss Rack Tower design for flexible placement Built-in enhanced charger Intelligent 2-stage charger control for efficient charging and preventing overcharge Provides overload protection Auto restart while AC recovery Multi-function LED indications and buzzer alarms

Operation Front Panel Controls and LED Indicators Shown below are the controls and indicator lights on the front of Inverex. Figure 1 Front Panel Power On/Off power on/off button is shown as above. Once Inverex has been properly installed and batteries are connected, press this button and Inverex will turn on automatically, and works in mains mode or inverter mode according to input AC source s status. When press this button again, Inverex will turn off automatically. Mains Mode LED The green LED will blink or light steadily when power mains is normal. Note: The green LED blinks every 2 seconds to indicate that battery capacity is not full enough and battery is being charged by high rate. Inverter Mode LED The Yellow LED will light when power mains is abnormal. And unit will work in inverter mode. Fault LED

The red LED will light when fault occurs. Back Panel Description Shown below are the components on the back of Inverex. Figure 2 Back Panel 1. DC Input Connector (Battery Terminal) 2. Input Breaker 3. AC Input Connector (Three-station Terminal Block) 4. Output Receptacle(s) 5. Input Voltage Range Selector : (Input voltage range is defined in specification chapter, and output voltage is the same as input voltage in mains mode) A. Select Narrow setting for general electrical appliance: If you select this mode, the Inverex operating voltage in Line mode is within

170~280Vac (90~145Vac) with the same output voltage. The line sensitivity is higher. Hence, you can connect the computer systems or other precision home equipment when you select this mode. B. Select Wide setting to save energy: If you select this mode, the Inverex operating voltage in Line mode will be extended within 90~280Vac (50~145Vac) with the same output voltage. The Inverex is with the lower line sensitivity. Moreover, there will be taking a long transfer time when the Inverex transfer from Normal mode to Battery mode during power failure. Hence, you can connect the home equipments, such as light bulb, fan, fluorescent tube, or TV when you select this mode. Caution!! If you select the Wide mode and connect the computer to the output of Inverex, the computer may reboot if the input voltage is too low to be accepted. In addition, the long transfer time will happen when power failure makes the computer reboot. Battery Connection Step 1- Pinch the bottom of DC input cover and Open it. See Figure 4. Step 2- Following battery polarity guide located near battery terminal! Place the battery cable ring terminal over Inverex s battery terminal. Tighten the M5 nut. Do not place anything between the flat part of battery terminal and the battery cable ring terminal, or overheating may occur. Caution! DO NOT place anything between battery cable ring terminals and battery terminals. The terminal stud is not designed to carry current. Apply Anti-oxidant paste to terminals after terminals have been torqued. Figure 4 Battery Cable Connection to Inverex

Step 3- Connect battery cables to your batteries Single battery connection: When using a single battery, its voltage must be equal to the voltage of Inverex Nominal Input Voltage (Apply to Inverex 500/1000) For the user operation safety, we strongly recommend that you should isolate the battery terminals before you start to operate the unit. Please refer to below instruction for further information. If you parallel more batteries to extend the backup time, please make sure that you already use tapes to isolate the rest battery terminals before you start to operate the unit.

Series battery connection: When using multiple batteries in series, all batteries must be equal in voltage and amp hour capacity, and the sum of their voltages must be equal to the voltage of Inverex Nominal Input Voltage (Apply to Inverex 1000/1500/2000) Parallel battery connection: When using multiple batteries in parallel, each battery s voltage must be equal to the voltage of Inverex Nominal Input Voltage (Apply to Inverex 500/1000 extend the backup time)

AC Connection Before having AC connection, match the power requirements of connected devices with the power output of Inverex to avoid overload. Consult a qualified electrician, and follow local code for the proper wire sizes, connectors and conduit requirements. Step 1- A three-station terminal block is provided to make AC input connections. Remove the cover plate. Caution!! Be sure that AC source is disconnected before attempting to connect AC to Inverex. Step 2- Connect the hot wire (black/brown) of AC input cable to the HOT IN terminal. Step 3- Connect the neutral wire (white/blue) of AC input cable to the NEU IN terminal Step 4- Connect the ground wire (green) of AC input cable to the GND IN terminal Step 5- Tighten screws to affix wires in terminal block. Step 6- Cover up the AC Input by the plastic cover. Step 7- Simply plug your equipment(s) into the output receptacle(s). Step 8- Turn on Inverex when you are using connected equipment(s). Figure 5 AC Input Connections

Troubleshooting Problem Possible Cause Remedy No LED display 1. Battery Weak 1. Re-charge battery cable and DC input connection. 2. Battery defect 2. Battery replacement. Mains normal but works in inverter mode Alarm buzzer beeps continuously Back up time is shorten 3. Power switch is not 3. Press and hold power pressed switch. 1. AC Input is missing 1. Check AC input connection. 2. Input protector is 2. Reset the input effective protector. 1. Overload 1. Verify that the load matches the capability specified in the specs. 1. Overload 1. Remove some non-critical load. 2. Battery voltage is too 2. Charge battery for 8 low. hours or more. If any abnormal situations occur that are not listed above, please call service people immediately.

MODEL Specification INVEREX 500 INVEREX 1000 INVEREX 1500 INVEREX 2000 INVEREX 1000 CAPACITY VA/W 500VA/300W 1000VA/600W 1500VA/900W 2000VA/1200W 1000VA/600W INPUT Nominal Voltage 110/120VAC or 220/230/240VAC Voltage Range 90-145VAC or 170-280VAC (Narrow Range) 50-145VAC or 90-280VAC (Wide Range) OUTPUT Voltage 120VAC or 230VAC Voltage Regulation(Batt. Mode) +10% / -18% Frequency 50Hz or 60Hz Frequency Regulation (Batt. Mode) +/-0.1 Hz Output Waveform BATTERY & CHARGER Charger Current 8 Amp +/- 1Amp 10 Amp +/- 1Amp Modified Sine-wave 10 Amp +/- 1Amp 10 Amp +/- 1Amp 6A +/-1Amp DC Voltage 12V +/- 0.2V 12V +/- 0.2V 24V +/- 0.4V 24V +/- 0.4V 24V +/- 0.4V Overcharge Protection 14.5V +/- 0.3V charger stops and fault 29V +/- 0.6V charger stops and fault 15-20ms TRANSFER TIME Typical 8ms Typical Typical EFFICIENCY AC to AC >95% INDICATOR DC to AC >80% AC Mode Battery Mode Battery Charging Mode Overload Fault AUDIBLE ALARM Low Battery at Battery Mode Overload Green lighting Yellow lighting Green flashing every 2 seconds Red flashing every 0.5 second Red lighting Sounding every 2 seconds Sounding every 0.5 second Fault Continously sounding PROTECTION Full Protection Discharge, overcharge, and overload protection PHYSICAL Dimension (DxWxH) mm 224 X 255 X 80 ENVIRONMENT Net Weight (kgs) 2.0 2.3 2.5 Operating Environment Noise Level * Product specifications are subject to change without further notice 0-40 C, 0-90 % relative humidity (non-condensing) Less than 55dB