HEINE NT4 MED V

Similar documents
UNIVERSAL BATTERY CHARGER II

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Installation manual wall-mounted distributor

Universal Battery Charger II.

Installation manual portable distributors

Language specific user manuals are available on

User Manual SONESTA S2 & S3

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Instructions for use of S5 Endo Motor

Charging Station - Instructions For Use

Rechargeable laryngoscope handles Directions for use

SmartVent. Instructions for Use Version 4 (Dec 2009)

SurePower TM II Battery Pack Guide

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

Hand-held Fundus Camera (Model :HFC) Operating Manual

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

SurePower Battery Pack Guide

Operating instructions Accu Jet

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

ACROBAT SWING STAND MODEL

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

362 Clamp Meter. Users Manual

Power Blade Charger Users Guide

AXIAL FANS Axis / Tubo OPERATION MANUAL

i3000s/i2000 Flex AC Current Probe

Handheld LED Light Source (HLS) Operator s Manual

portable ac/dc suction pump USER S MANUAL ITEM # 18605

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

IsoLED FLEX I CUSTOMER MANUAL

Multi-Mover Charger for model L25

Charging base guide. A Sonova brand

Invacare. Battery Charger User Manual. Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU

ELORA BATTERY INTERFACE. Owner s Manual

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Xenon Fiberoptic Lightsource

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

c-go 24V/6A 24V/8A 24V/12A

ADN-W L 10. Battery Charger. Instruction manual

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

Language specific user manuals are available on

Cordless Rechargeable Saw Instructions for Use

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

80 Series V Digital Multimeter Safety Information

DenLite Illuminated Dental Mirror

Lumitester PD-20 Control Kit

Fixed Ceiling Lift FL

Assembly and Maintenance Manual Type ASNU

ADN-W CASE. Transport & Charging Case. Instruction manual

Technical Documentation

2-Year Limited Warranty. See the Users Manual for the full warranty.

i400s Calibration Information Introduction

L Charger. Instruction manual

Intelligent NiMH/NiCd/Li-ion Charger TN456

3-Year Limited Warranty. See the Users Manual for the full warranty.

Operating Instructions. International English. CCS Dust Extractor

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

SUBMERSIBLE WATER PUMP

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

C3 Operating Instructions

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

PowerAir Compressor Installation

Instructions for use. Quick couplings RQ-03, RQ-04, RQ-14, RQ-24, RQ-34

Model 605 Portable Aspirator

Battery Charger JCB- SCH20LI.2

Operating instructions

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Laerdal Compact Suction Unit 4

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

PY-11 Voltage & Continuity Tester

ACROBAT SWING STAND MODEL

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

User s Manual Power Supply IM E. 5th Edition

USE, CARE & STERILIZATION INSTRUCTIONS. Consumable Accessories Burs Saw Blades K-Wires Steinmann Pins Twist Drills Rasps Ortho Pins/Drills Guide Wires

Instructions for use. Prosthodontic screwdriver IA-400

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Battery Charger JCB-FCH20LI2

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

ADN-W BA. Li-Ion Battery Pack. Instruction manual

Assembly and Maintenance Manual Type AS

OPERATION MANUAL. Motor Handpiece System for Root Canal Enlargement

Battery Charger JCB-FCH12Li

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

seca 874 Instructions for Use

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

V3700UK OWNER S GUIDE.

Register your instrument! HeatSealer S100. Operating manual

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

6 Bay Battery Charger Operation Manual

Keeler Spectra Plus. Instructions. Next

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

1 Intended Use. 2 Precautions for handling and operation. English

Transcription:

HEINE NT4 MED 113594 2018-01-23 V-200.00.601

HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively for charging HEINE 4 series rechargeable handles. These must include a HEINE rechargeable battery. Federal law restricts this device to sale by or on the order of a Physician or Practitioner! Warnings and Safety Information CAUTION! Indicates potential hazardous situations. Ignoring the corresponding instructions may lead to dangerous situations of mild to moderate extent. (Background color, yellow; Foreground color, black for color print, or black in light-gray background.) NOTE! Indicates valuable advice in terms of set up, operation, maintenance or repair, as applicable. Notes are important, but not related to hazardous situations. Product overview Setting up USA primary plug: The mains socket adapter of the power supply is interchangeable, this enables worldwide operation. The pictograms describe the procedure of changing the adapters. Place the power supply in such a position where it is accessible and easily unplugged. Do not place the device on soft surfaces or fabrics. Apart from the appropriate charging handles, no foreign objects (e.g. paperclips) should be placed into the charging slots. By plugging the mains transformer into the mains socket, the charger is ready for use. The charger ensures that batteries are kept in good condition irrespective of handle size. Instruments placed next to each other must not touch one another. When using different sized handles, reduction rings can be used or exchanged to ensure an optimal fit for all handles at any time. 2/8 MED 113594 2018-01-23

Reduction rings for BETA 4 NT: After use, the handle can be replaced into the charging slot and remain there. Handles cannot be overcharged. The device must be disconnected from the mains supply when the adaptors are being fitted. If the second charging compartment is not in use it can be sealed off by the dust cap which is supplied with the unit. The pulsating charge indicator (light ring) around the charging slot, indicates that a charging current is flowing and the battery is charging. The charging process takes place in accordance with the JEITA* temperature standard for Li-ion batteries. This can lead to short-term charging interruptions at ambient temperatures > 30 C which optimizes the battery life. (* Japan Electronics and Information Technology Industries Association) A constant light around the charge indicator indicates that a HEINE handle is present but no charging process is taking place. The charge indicator does not light up when the charging slot is empty or a malfunction is present. If a fully charged handle remains in the charger, there will be brief recharging cycles (< 5 min) this is visible from the flashing of the charge indicator. The handle is fully charged and ready for use. The LED indicates the operational readiness of the power supply. The charger may only be operated with the mains voltage specified on the nameplate of the power supply. Unplug the unit from the mains if not in use over long periods. In the event of fluid ingress in the housing, the charger should be taken out of service and checked by an authorized person. Follow the instructions for the charger and rechargeable handles. When replacing the handles in the charging compartments, ensure that the internal contacts in the compartment are clean and that the instruments are switched off. The rechargeable battery can only be charged when fitted to the handle. The HEINE charger is intended for installation in medical areas outside the patient environment (at least 1.5 metres from the patient or patient support pursuant to IEC 60601-1, see figure). Fig1: The above figure defines the patient environment (minimum radius around the patient). To prevent mechanical and electrical breakdown, never install or store the charger in the following areas: - areas exposed to high moisture or condensation, - areas exposed to extreme environmental conditions, - areas subject to constant vibrations, - areas severe temperature fluctuations, - outdoors. MED 113594 2018-01-23 3/8

Hygienic Reprocessing Instructions on hygienic reprocessing must be adhered to, based on national standards, laws and guidelines. Classification according to KRINKO: non-critical Spaulding Classification USA: non-critical Before reprocessing, disconnect the device from the power source. In the event of suspected contamination, carry out hygienic reprocessing of the instrument. The described reprocessing measures do not replace the specific rules applicable for the establishment. Only the reprocessing agents and procedures called out in this instruction for use are approved. The reprocessing is to be carried out by persons with adequate hygienic expertise. Observe the instructions of the manufacturer of the reprocessing media. Place only reprocessed handles into the charger. Hold the charger with the slots facing down when cleaning and disinfecting. Procedure Clean and disinfect the device manually (wipe clean and wipe disinfect). Recommended agents Cleaning agent, if necessary: enzymatic (e.g. Cidezyme by ASP ) Disinfectant agent: quaternary ammonium compounds (e.g. Sani-Cloth AF3 by PDI, Sani-Cloth HB by PDI ) Maintenance The device is maintenance free. The power supply must not be opened (risk of electrical shock). Service The device has some components serviceable by the end user. General Warnings Check the correct operation of the device before use! Do not use the device if there are visible signs of damage. Do not use the device in fire- or explosive risk area (e.g. oxygen saturated or anaesthetic environments). Do not modify the device. Use only original HEINE parts, spare parts, accessories and power sources. Repairs shall only be carried out by qualified persons. Turn the handle off during the charging process. The device must not be placed near strong magnetic fields, e.g. MRI units. General Notes The warranty for the entire product is invalidated if non-genuine HEINE products or non-original parts are used and if repairs or modifications are made to the device by persons not authorized by HEINE. For more information, please visit www.midmark.com. The expected life cycle, when the device is normal used and the warning and safety information as well as the maintenance instructions are observed, is up to 10 years. Beyond this period, the product may continue to be used if it has been determined to be in safe and good condition. Do not pull on the cord/cable to disconnect the power supply from the mains. 4/8 MED 113594 2018-01-23

Disposal The product must be recycled as separated electrical and electronic devices. Please observe the relevant state-specific disposal regulations. Technical specifications Environmental conditions for operation Environmental conditions for storage Environmental conditions for transport Main Power Supply Current consumption Output Fuse Charging time Class Protection class IP 20 +10 C to +35 C 30 % to 75 % rel. humidity 700 hpa to 1060 hpa +5 C to +45 C 45 % to 80 % rel. humidity 500 hpa to 1060 hpa -20 C to +50 C 45 % to 80 % rel. humidity 500 hpa to 1060 hpa 100 240 V AC / 50 60 Hz max. 205 ma max. 6 V / 0,9 A Integral overload protection max. 6 h II MED 113594 2018-01-23 5/8

Electromagnetic disturbances Requirements and tests The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such environments. Statement for the operational environments: Performance features of the ME system that have been determined to be essential to the performance Warning Inside hospitals except for: near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances are high. None Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the NT4, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. A list of all cables, transducers and other accessories that are relevant for the EMC compliance Test None Compliance RF emissions CISPR11 Group 1 Class B Harmonic Emissions Voltage Fluctuations/Flicker Passed Passed 6/8 MED 113594 2018-01-23

Explanation of utilized symbols The following symbols are used on the device or on the packaging: The CE mark indicates that the product complies with the European medical device directive 93/42/EEC. REF Catalogue- or order number SN Serial number Manufacturer Date of manufacture Product bearing this symbol may not be disposed of together with general household waste, but instead requires separate disposal according to local provisions. (European Waste Electrical and Electronic Equipment Directive, WEEE) Temperature limits in C for storage and transport Temperature limits in F for storage and transport Humidity limitation for storage and transport Pressure limitation for storage and transport Instructions for use Alternating current (AC) Fragile, handle with care! Keep dry! Follow instructions for use! (Background color, blue; Foreground color, white for color print, or white on black background.) MED 113594 2018-01-23 7/8

Approval mark of SIQ UL Recognized Component Mark (for USA and Canada). Class II equipment Manufacturer HEINE Optotechnik GmbH & Co. KG Kientalstr. 7 82211 Herrsching GERMANY www.heine.com Distributed by Midmark Corporation 60 Vista Drive Versailles, Ohio 45380 www.midmark.com