Bard Throw-Away and Permanent Air Filter Specifications. Bard offers a wide selection of permanent and replaceable filters for various applications.

Similar documents
Maxi-Grid. A Complete Line of Internally-Supported Panel Filters. Koch Filter Corporation

PANEL & CARTRIDGE FILTERS

SPECIFICATION FOR FILTERS, AIR (HVAC) (This specification is released for procurement purposes until revised or rescinded.)

EZ FLOW II FIBERGLASS FILTER

Product Selection Guide. We provide superior filtration solutions to improve the quality of life

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

PRODUCT SELECTION GUIDE FILTRATION SOLUTIONS TO IMPROVE THE QUALITY OF LIFE

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

WELCOME. Give us a call.

SECTION HVAC AIR CLEANING DEVICES

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

REPLACEMENT PARTS MANUAL

quatroair.com AIR TECHNOLOGIES INC.

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

TOTALINE ELECTRONIC AIR CLEANERS

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

REPLACEMENT PARTS MANUAL

microns microns 70% 85%

REPLACEMENT PARTS MANUAL

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

Excelair. Every filter is created to perfection!

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB

...And Watch Your Grow!

Factory Option Codes L M E S P R D V F F H E

nivia utilities Why Air Filters???

Introduction. Duct-Free Plenum Boxes. I-TEC Accessories Plenum Boxes, Risers, Trim Kits, and Wall Curbs

Complete Line of Airguard Synthetic Bag Filters

Filtration Equipment

INDOOR ENVIRONMENTAL SOLUTIONS

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

1 of 8. Air Solutions Sdn. Bhd. Euro Carb. Box Type Chemical Filter

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

ISC Sales. ISCEnclosureCooling.com Toll Free:

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

AIR FILTER The World's Most Unique Filtration System

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

FOR USE IN SOLUTION AIR HANDLING UNITS

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

FlowAir CATALOG.

PAINT BOOTHS ARRESTORS

TRI-DEK FILTERS OVER 40 YEARS OF INNOVATION

REPLACEMENT PARTS MANUAL

ALL PRODUCTS BROCHURE

REPLACEMENT PARTS MANUAL

ASHRAE GAS-PHASE AIR CLEANER TEST REPORT. Test Laboratory: RTI 3040 Cornwallis Road Research Triangle Park, NC

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

Product Data. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR) EZ Flext (EXPXX) Sizes 16, 20, 24. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR)

ENERGY RECOVERY SYSTEM 60 HZ

A. NU2035 HRV Specifications NU2035

PAINT BOOTHS ARRESTORS

High Performance Fan Coils FCHG Genesis Series Horizontal

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

PAINT BOOTHS ARRESTORS

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

REPLACEMENT PARTS MANUAL

Downflo workstation DuSt ColleCtorS

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH301 WH361. Models: Contents. General Notes. Important. Description

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

REPLACEMENT PARTS MANUAL

WE GUIDE AIR LOUVERS

downflo workstation dust collectors

TECHNICAL SPECIFICATIONS

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

EXT HEPA/CARBON FUME HOOD

FRG Air Cleaners. Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: SH381 SH431 SH491. Contents. General Notes. Important

Models: WL302, WL372. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS. Models: W30H1 W36H1. Contents. General Notes. Important. Description

EXT DUCTLESS FUME HOOD

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

DESKTOP CONTAINMENT SYSTEM

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

FilterMax F. Modular dust collector with integrated pre-separator

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL WA302, WA372. Models: Contents. General Notes. Important.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

melt-blown layer provides more surface loading so the filter is easier to pulse clean. Specialty filters, such as PTFE and spunbond filters, also are

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

RCBA- MULTIFLEX INDOOR COILS

Instruction P/N:EVO1800

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

AIR-AIR ENERGY CONSERVATION MODULE

For Residential and Light Commercial Applications

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

THE WORLD LEADER IN CLEAN AIR SOLUTIONS. (Low Pressure Drop, High Capacity)

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: W42A1 W42A1D W48A1 W48A1D W60A1 W60A1D. General Notes. Contents.

Our heritage enables us to take a small company approach to the day to day activities of each and every customer.

Portable Filter Carts Models 5MF and 10MF

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

FILTRATION FOR ANY APPLICATION

MODEL 900 IMPELLER-TYPE FLOW METER

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

F 45 R REVERSE POCKET FILTERS

Transcription:

Bard Throw-Away and Permanent Air Filter Specifications Introduction Bard offers a wide selection of permanent and replaceable filters for various applications. Replaceable throw-away filters must be replaced with filters of the same size and rating shown in the unit specification sheets. Improper filter sizing or filter rating may result in poor unit performance, dust or improper filtration, and unit damage. When installing a replaceable filter, always insert the filter media with the airflow directional arrow aligned with the unit airflow direction. Permanent filters are meant to be cleaned in the field on a regular basis. Replacement of permanent filters must be ordered from Bard to ensure proper unit operation. Improper filter replacement may result in air bypass around the filter or unwanted debris and dust being recirculated. Improper permanent filters in outdoor applications may result in water infiltration inside the unit and unit damage. When installing a permanent filter, always insert the filter media with the airflow directional arrow aligned with the unit airflow direction. Bard 7003-XXX Permanent Indoor Filters Bard permanent indoor filters are normally a way to save maintenance costs of replacing throw-away indoor filters. Typically permanent indoor filters are made of foam, synthetic, or other washable media. Cleaning the filter with a non-abrasive soap or detergent is required to maintain proper filtration during the lifetime of the product. Filters must be inspected for media damage and replaced if necessary with a Bard approved filter. Foam Media Synthetic Media Bard 7003-XXX Permanent Outdoor Filters Bard permanent outdoor filters are used to reduce the amount of larger debris entering the unit, and in some cases reduce potential rain or snow infiltration. Permanent outdoor filters must be replaced with Bard approved filter. Be sure to look at the side of the filter and identify the Bard part number when ordering replacement filters. Because of several layers of media inside the filter, it is very important to install the filter with the airflow arrow in the correct orientation. Also inspect the media for weep holes in the frame perimeter. Weep holes must always be in the bottom of the filter when installed. Foam and Aluminum Media Part Number Identification Aluminum Media Supersedes NEW Page 1 of 6

Throw-Away Air Filters Bard throw-away filters are available in 1 and 2 depths. Various MERV ratings are available for different applications. When replacing a throwaway filter, make sure to use a replacement that meets the same size and filtration specifications of the existing filter. The filter must also be agency approved to meet required flame/smoke ratings for indoor HVAC products. Always use a high quality undamaged filter to ensure dust, dirt, and debris does not bypass or pass through filter media. Failure to do so may result in unit damage, shortened unit life cycle, or unit failure. Never attempt clean & reuse a throw away filter as the integrity will be compromised. 2" Pleated Filter 1" Fiber Throw-Away 1" Filter Information 2" Filter Information Indoor Filter MERV Ratings MERV Rating Dust Spot Efficiency Arrestance Particle Size Filtration Typical Applications MERV2 <20% 65-70% >10ppm Minimal Filtration Applications MERV8 30-35% >90% 3 to 10ppm Light Filtration Commercial Applications MERV11 60-65% >95% 1 to 3ppm Medium Filtration Commercial Applications MERV13 89-90% >98%.3 to 1ppm High Filtration Commercial Applications Nominal Filter Dimensions Throw-away filter dimensions are normally given in nominal sizes. Nominal filter length: Width (A) -.5" to.63" Length (B) -.5" to.63" Depth (C) -.13" to 25" C Permanent filter dimensions are normally given in actual measured dimensions. A B Supersedes NEW Page 2 of 6

7004-XXX Throw-Away Filters Page 1 All throw away filter dimensions are in nominal measurements. Obsolete filters are in red.** Dimension Dimension Dimension A B C * Restriction is given in inches WC. ASHRAE 52.2 MERV Min Rating Max Initial Restriction @ 500FPM* UL900 Class Bard Part # Nominal* Nominal* Nominal* II (Y/N) Pleated 7004-001** 10 20 1 MERV 2 0.15 Yes No 7004-003 12 20 1 MERV 2 0.15 Yes No 7004-006** 14 25 1 MERV 2 0.15 Yes No 7004-007** 15 20 1 MERV 2 0.15 Yes No 7004-008** 15 30.63 1 MERV 2 0.15 Yes No 7004-009 16 16 1 MERV 2 0.15 Yes No 7004-010 16 20 1 MERV 2 0.15 Yes No 7004-011 16 25 1 MERV 2 0.15 Yes No 7004-012** 20 20 1 MERV 2 0.15 Yes No 7004-013** 12 25 1 MERV 2 0.15 Yes No 7004-014** 16 25 2 NA NA NA NA 7004-015** 24 24 1 MERV 2 0.15 Yes No 7004-016 20 30 1 MERV 2 0.15 Yes No 7004-017** 22 22 1 MERV 2 0.15 Yes No 7004-018** 25 25 1 MERV 2 0.15 Yes No 7004-019 16 30 1 MERV 2 0.15 Yes No 7004-020 10 25 1 NA NA NA NA 7004-021 16 25 1 NA NA NA NA 7004-022** 16 34 1 NA NA NA NA 7004-024** 15 31.125 1 NA NA NA NA 7004-025 16 25 2 MERV 8 0.30 Yes Yes 7004-026 16 30 2 MERV 8 0.30 Yes Yes 7004-027 20 30 2 MERV 8 0.30 Yes Yes 7004-028** 10 20 2 MERV 8 0.30 Yes Yes 7004-029** 16 25 2 MERV 8 0.30 Yes Yes 7004-030** 16 30 2 MERV 8 0.30 Yes Yes 7004-031** 20 30 2 MERV 8 0.30 Yes Yes 7004-032 16 16 2 MERV 2 0.30 Yes No 7004-033 16 20 2 MERV 2 0.30 Yes No 7004-034 16 16 2 MERV 8 0.30 Yes Yes 7004-035 16 20 2 MERV 8 0.29 Yes Yes 7004-036 16 25 2 MERV 2 0.30 Yes No 7004-037** 16 25 2 MERV 6 NA NA NA 7004-038 10 17 1 MERV 2 0.15 Yes No 7004-039 14 28 1 MERV 2 0.15 Yes No 7004-040 20 25 2 MERV 8 0.29 Yes Yes 7004-041** 16 20 1 MERV 2 0.30 Yes Yes 7004-042** 20 20 1 MERV 2 0.30 Yes Yes Supersedes NEW Page 3 of 6

7004-XXX Throw-Away Filters Page 2 All throw away filter dimensions are in nominal measurements. Obsolete filters are in red.** Dimension Dimension Dimension A B C * Restriction is given in inches WC. ASHRAE 52.2 MERV Min Rating Max Initial Restriction @ 500FPM* UL900 Class Bard Part # Nominal* Nominal* Nominal* II (Y/N) Pleated 7004-043** 20 25 1 MERV 2 0.30 Yes Yes 7004-048 16 30 2 MERV 11 0.31 Yes Yes 7004-049 20 30 2 MERV 11 0.31 Yes Yes 7004-050 24 30 2 MERV 8 0.30 Yes Yes 7004-051 24 30 2 MERV 11 0.31 Yes Yes 7004-052 20 20 2 MERV 8 0.29 Yes Yes 7004-053 24 30 2 MERV 13 0.31 Yes Yes 7004-056 12 24 1 MERV 2 0.30 Yes Yes 7004-057 12 24 2 MERV 8 0.30 Yes Yes 7004-059 16 25 2 MERV11 0.31 Yes Yes 7004-060 20 20 2 MERV11 0.31 Yes Yes 7004-061 16 25 2 MERV13 0.31 Yes Yes 7004-062 16 30 2 MERV13 0.31 Yes Yes 7004-063 20 20 2 MERV13 0.31 Yes Yes 7004-064 20 30 2 MERV13 0.31 Yes Yes 7004-065 20 24 2 MERV8 0.30 Yes Yes 7004-066 20 24 2 MERV11 0.31 Yes Yes 7004-067 20 24 2 MERV13 0.31 Yes Yes Supersedes NEW Page 4 of 6

7003-XXX Permanent Filters Page 1 Note: All permanent filter dimensions are in actual measurements. Obsolete filters are in red.** Indoor/ Outdoor Bard Part # Dimension A Dimension B Dimension C Rating Media Type Weep Holes 7003-001** 10 20 1 indoor Foam 20-25fpi No 7003-002** 14 25 1 Indoor Par 10 Fiber No 7003-003** 15 20 1 indoor Foam 20-25fpi No 7003-004** 16 25 1 indoor Foam 20-25fpi No 7003-005** 20 20 1 indoor Par 10 Fiber No 7003-006** 20 22 1 indoor Par 10 Fiber No 7003-007** 17.5 17.5.5 indoor Par 10 Fiber No 7003-008** 17 32 1 Indoor Par 10 Fiber No 7003-009** 11.5 19.5.75 indoor Foam 20-25fpi No 7003-010** 24 24 1 indoor Par 10 Fiber No 7003-011** 22 23.5 1 indoor Par 10 Fiber No 7003-012** 15 30.63 1 indoor Par 10 Fiber No 7003-013** 22 22 1 indoor Par 10 Fiber No 7003-014** 18.75 20 1 indoor Par 10 Fiber No 7003-015** 20 22.75 1 indoor Par 10 Fiber No 7003-016** 13 20 1 indoor Foam 20-25ppi No 7003-017** 4 26 1 indoor Rigid pad No 7003-018** 13 20 1 Indoor Hog hair No 7003-019** 4 25.63.5 Indoor Foam 30ppi No 7003-020** 11.5 17 1 indoor Foam 20-25fpi No 7003-021** 10 20 1 Indoor Foam 20-25ppi No 7003-022** 15 20 1 Indoor Foam 20-25ppi No 7003-023** 9.5 20 1 Indoor Foam 20-25ppi No 7003-024** 14 25 1 Indoor 1171 BW Disp. No 7003-025** 15 30.63 1 Indoor 1171 BW Disp. No 7003-026** 20 30 1 Indoor 1171 BW Disp. No 7003-027 12.63 25.44.25 Indoor Foam 20ppi No 7003-028** 25 25 1.25 Indoor Foam 20-25ppi No 7003-029** 15 30.63 1 Indoor Foam 20ppi No 7003-030 20 30 1 Indoor Foam 20ppi No 7003-031 15.5 29.5.75 Indoor Foam 20ppi No 7003-032 16 25 1 Indoor Foam 20ppi No 7003-033 8.88 27.63.88 Outdoor Alum mesh Yes 7003-034 8.88 22.63.88 Outdoor Alum mesh Yes 7003-035 12.63 32.63.88 Outdoor Alum mesh Yes 7003-036 7.88 25.5.5 Indoor Foam 30ppi No 7003-037** 12 20 1 Indoor Foam 20-25ppi No 7003-039 5.75 21.88.88 Outdoor Alum mesh Yes 7003-040 16 20 1 Outdoor Alum mesh Yes 7003-041** 20 20 1 Outdoor Alum mesh Yes 7003-042 20 25 1 Outdoor Alum mesh Yes Supersedes NEW Page 5 of 6

7003-XXX Permanent Filters Page 2 Note: All permanent filter dimensions are in actual measurements. Obsolete filters are in red.** Indoor/ Outdoor Bard Part # Dimension A Dimension B Dimension C Rating Media Type Weep Holes 7003-043 16 25 1 Outdoor Alum mesh Yes 7003-044 9.44 30.25.88 Outdoor Alum mesh Yes 7003-046 14 25 1 Outdoor Alum mesh Yes 7003-047** 8.88 17.63.88 Outdoor Alum mesh Yes 7003-048 12 14 1 Outdoor Alum mesh Yes 7003-054 12.75 27.88.88 Outdoor Alum mesh Yes 7003-055** 20 30 1 Outdoor Alum mesh Yes 7003-056 12.38 16.75.88 Outdoor Alum mesh Yes 7003-057 10 36.5 Outdoor Alum mesh Yes 7003-058 12.66 24.25.88 Outdoor Alum mesh Yes 7003-059 9 26 1 Outdoor Alum mesh Yes 7003-060 16.75 19.38.88 Outdoor Alum mesh Yes 7003-061 12 32.63 1 Outdoor Alum mesh Yes 7003-062 17.88 40.13.88 Outdoor Alum mesh Yes 7003-063 7.5 28.5.88 Outdoor Alum mesh Yes 7003-064 8 16.75.5 Outdoor Alum mesh Yes 7003-066 15.75 36.25.88 Outdoor Alum mesh Yes 7003-067 15.75 31.25.88 Outdoor Alum mesh Yes 7003-068 5.82 19.75.88 Outdoor Alum mesh Yes 7003-069 6.38 39.19 Outdoor Bug Screen No 7003-070 6.38 34.19 Outdoor Bug Screen No 7003-071 6.38 27.19 Outdoor Bug Screen No 7003-072 12.25 26.25.88 Outdoor Alum mesh Yes 7003-073 12 24 1 Indoor Foam No 7003-074 12.25 30.38.88 Outdoor Alum mesh Yes 7003-075 11.75 26.25.5 Outdoor Uni-foam 25ppi No 7003-076 11.75 20.88.5 Outdoor Alum mesh Yes 7003-077 16 30 2 Outdoor Synthetic No 7003-078 20 30 2 Outdoor Synthetic No 7003-079 15.75 36.25.88 Outdoor Alum mesh Yes 7003-080 15.75 31.25.88 Outdoor Alum mesh Yes 7003-081 20 34.75.5 Outdoor Alum mesh Yes Supersedes NEW Page 6 of 6 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S3569 May 2018 Supersedes: NEW