Servo-Assisted, Modular, 8mm Wide / and 4/ Multi-Way Valves; Servo Assisted; Flow Rate: 0.6 ft /min.; /8 NPT and /4 O.D. Legris Connections Advantages / Benefits Optimum system solutions due to high level of modularity High flow rate in a compact design Long service life even with non-lubricated air Manual override standard Easily expanded due to modular assembly Various options for the connection ports and 4 High cycle life Fieldbus compatible Wide selection of cable plugs available with added circuitry Light weight Approval Design/Function includes high cycle life, diaphragm seat design valves in / and 4/ way versions. The valve consists of three modules; valve body with servo-diaphragm, plungers and seat seal, solenoid operator and sub-base assembly. The body and valve internal parts are made of high quality thermoplastic, and a stainless steel return spring. A 6 mm rocker solenoid valve type 606 with rectifier is used as the pilot. Spade connectors are used for electrical contact, per DIN 4 650 Form C. Spades are compatible with Type 506 cable plugs or female receptacles or Burkert valve manifolds. Coils can be rotated to position the spades in front for cable plugs and out the back for modular connection. Burkert Contromatic USA 60 McGaw Avenue Irvine, CA 964 Tel. 949..00 Fax 949..98 www.burkert-usa.com The manifolds can be powered through various fieldbus systems, multipole or common terminals. The block assembly is made with pneumatic modules using integrated locking technology. Type 606 impulse version is a bistable valve used as pilot valve for. The operation has to be done through external pole reversal (e.g. PLC). The advantages of the impulse version are functional safety during short time power failure, saving of energy and low heat generation. It is applicable for switching systems with impulse control. Burkert Contromatic Inc. 760 Pacific Road, Unit Oakville, Ontario, Canada L6L 6M5 Tel. 905.847.5566 Fax 905.847.9006 Applications Fluids Lubricated and non-lubricated air, neutral gases Applications Control valves actuation (single valves, valve manifolds) for pneumatic linear and rotary actuators ideal for: Food and beverage industry General processing industry Packaging machine manufacturers Textile industry Machine tool manufacturers Woodworking machine manufacturers Fluid Control Solutions
Servo-Assisted, Modular, 8mm Wide Technical Data (Valve Assembly) Circuit Functions Symbol Circuit Functions Symbol C / way valve, when de-energized, outlet port exhausted 4 4 0 D / way valve, when de-energized, port pressurized 0 C / way valve, with impulse at terminal outlet port A exhausted, with impulse at terminal outlet port A pressurized G 4/ way valve, when de-energized, pressure inlet port connected to outlet port, outlet port 4 exhausted Specifications Circuit Function Orifice ) C v Pressure Port Connections Range [mm] [PSI] C (/) 4.0. 8-00 supply ports and : sub-base D (/) 4.0. 8-00 service ports and 4: threaded port NPT /8 G (4/) 4.0. 8-00 push-in coupling /4 O.D. or screwed tube connector SL 6/4 mm ) Q = 0.6 ft /min. with 85 PSI upstream and 5 PSI pressure drop across the valve at 68 F Valve Specifications Body material PA (Polyamide) Valve internal parts PA (Polyamide) Return spring Stainless Steel Seal material NBR Fluids Lubricated, non-lubricated compressed air, or neutral gases Media temperature 4 F to F (-0 C to 50 C) Ambient temperature 4 F to 0 F (-0 C to 55 C) Response times ) W coil / W coil Open (On) 5 ms 5 ms Close (Off) 0 ms ms (without electronics) Close (Off) 0 ms 0 ms (with electronics) 4) Response times for impulse versions Minimum duration of impulse: Release coil (spade and ) Operating coil (spade and 4) 0 ms 0 ms Port connections Connection and Sub-base at the back Connection and 4 /8 NPT in front Plug-in coupling /4 O.D. tubing below or in front Screwed tube connector SL 6/4 mm, in front Solenoid Specifications Operating voltage 4 VDC 4 V impulse (external pole reversal necessary) 0-0 VDC 0-40 VDC (for alternating current cable plug Type 506 with rectifier necessary) 4) Voltage tolerance ±0% Electrical power W, W, W consumption Duty cycle Electr. connection Rating Ex-approval 00% continuously rated Spade connectors in front or at the back acc. DIN 4 650 Form C, for cable plugs Type 506 (see accessories) NEMA 4 (with cable plug) (see datasheet Ex-versions) 4) When using electronics (diodes for controlling LEDs or for rectifying), the closing time is delayed 8 to 0 ms. Installation Mounting position: Any, but preferably with solenoid system upright ) Measured at connection ; time from electrical switching to pressure increase to 90% (opening) or pressure drop to 0% (closing) of operational pressure of 88 PSI. The valves given apply for DC and AC.
Servo-Assisted, Modular, 8mm Wide Dimensions Single Valve [mm] / way valves, circuit function C, supply ports and as sub-base, spade connectors in front or at the back ) Manual override Picture : /4 O.D., below. Picture : /4 O.D. tubing, below. Spade connectors at the back. 4/ way valves, circuit function G, port connections and as sub-base, spade connectors in front or at the back ) Manual override Threaded port Picture : Threaded port /8 NPT, in front. Picture 4: /4 O.D. tubing and /8 NPT threaded port in front, with one-way flow restrictor. Pict. 5: /4 O.D. tubing, in front. Pict. 6: /4 O.D. tubing, below. Pict. 7: Screwed tube connector SL 6/4 mm, in front. ) Spade connectors in front: for block assembly; spade connectors at the back: for assembly on valve blocks All sub-base valves are available with spade connectors in front or at the back (see ordering chart)
Servo-Assisted, Modular, 8mm Wide Dimensions [mm] Block and Wall Mounting with Pneumatic Modules Type MP05 55 up to 76 (depending on service port) Exploded View of with Pneumatic Modules Type MP05, Coil Spacing 9 mm Connector module - left - Basic module - valve space - Interface module: Supply ports pushed through for additional pressure supply or Connector module: Supply ports closed; - right - thereby various operating pressures in one manifold possible Supply ports (R), (P) Basic module Connector module - valve space - - right - Example of a valve manifold. Single modules or pre-mounted manifold are available When ordering, please specify the desired configuration from right to left. For information on assembly of a valve manifold, please see datasheet Customized Pneumatic Systems Solutions. 4
Servo-Assisted, Modular, 8mm Wide Ordering Chart Valves (Other Versions on Request) Standard delivery: All valves have manual override and NBR seals; supply ports and as sub-base version; with mounting screws and sub-base seal; spade connectors per DIN 4 650 C front or at the back; without cable plug (see accessories) Elect. connection: For manifold assembly with spade connectors in front: cable plug Type 506 (see accessories) For manifold assembly with spade connectors at the back: integrated female connectors on the electrical output modules of the manifold assembly Circuit Orifice Function [mm] C 4.0 D 4.0 C v........ Pressure Range [PSI] 8-00 8-00 8-00 8-00 8-00 8-00 8-00 8-00 Port Connections 4 and /4 O.D. tubing, below (Picture and ) /4 O.D. tubing, below (Picture and ) /4 O.D. tubing, in front (Picture 5) /4 O.D. tubing, below (Picture 6) /4 O.D. tubing, in front with one-way flow restrictor (Picture 4) Threaded port /8 NPT, in front (Picture ) Threaded port /8 NPT, in front with one-way flow restrictor (Picture 4) Screwed tube connector SL 6/4 mm, in front (Picture 7) Voltage/ Frequency* [V/Hz] 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 04/Impulse 0-0/DC 0-40/DC 0-0/DC 0-40/DC Electrical Power Consumption [W] *) For AC current the cable plug Type 506 with rectifier must be used, see accessories. Item No. Spade Connectors at the Back for Electrical Output Modules 456 707 G 458 84 E 45777 W 456708 R 456709 J 45886 G 4567 V 45895 H 45778 F 45674 W 45675 X 4589 F 45676 Y 45888 J 45779 G 45677 Z 45678 A 45678 C 45889 K 457740 M 45679 D 45670 A 4567 X 45774 A 4567 Y 4567 Z Item No. Spade Connectors in Front for Individual Plug Connections*) 458 85 F 458 87 H 458 96 A 458 94 G 5 5 Q 5 6 R 64 K 66 M 5
Servo-Assisted, Modular, 8mm Wide Ordering Chart Pneumatic Modules Type MP05 Module Item No. Module Item No. Connector module left, G /8 75 N Connector module right, G /4 54 H Connector module left, NPT /8 76 P Connector module right, NPT /4 55 A Connector module left, G /4 5 F Basic module valve space 56 B Connector module left, NPT /4 5 G Basic module valve space 57 C Connector module right, G /8 77 Q Basic module valve space with -way flow restrictor 58 M Connector module right, NPT /8 78 Z Basic module valve space with -way flow restrictor 59 N Ordering Chart Accessories Accessory Part Description Item No. Cable plug Type 506 ) without circuit, 0-50 V 008 5 P Cable plug Type 506 ) with LED, - 4 V 008 40 A Cable plug Type 506 ) with LED and varistor, - 4 V 008 408 Q Cable plug Type 506 ) with LED, rectifier and varistor, - 4 V 008 54 Q Cable plug Type 506 ) with LED, rectifier and varistor, 0-0 V 008 55 R Cable plug Type 506 ) with LED, rectifier and varistor, 00-40 V 008 56 J Manifold G /8 Intermediate supply 64 09 C Manifold NPT /8 Intermediate supply 64 08 D Blanking screw G /8 6 09 Y Blanking screw G /4 6 00 V Blanking plug for push-in coupling /4 O.D. tubing US-055 Blanking plug for screw tube connector SC6/4 005 90 E Covering plate (black) for vacant valve spaces 64 D Indicating tag 64 pieces 6 86 L ) With these accessories, only a partial list of possible cable plugs with built-in circuit function are mentioned. For other versions, see data sheet Type 506. A flat seal and a mounting screw come with each cable plug Operation of Impulse Versions Standard cable plug Type 506 - through external pole reversal (e.g. PLC) Cable plug - with internal pole reversal In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. US_5470M_0/00 6