Round duct diffuser DBB-RR

Similar documents
Round duct grille Model KG-RR

Ceiling Slot Diffuser Model DSX

Compact Grille Model KG

Ventilation grille Model AL

Ventilation grille Model IB-R

Ceiling diffuser 4DE

Nozzle Jet Diffuser Model DSA

Ceiling diffuser 4DF

Swirl Diffuser Model DQF

Round Duct System Accessories RR - accessories

Ceiling Slot Diffuser DSC

ceiling swirl diffuser Model DQJA / DQJR

Ceiling Slot Diffuser DSC

Round Duct System Model RR-Complete

ceiling swirl diffuser DQJ

Round Duct System Model RR-Complete

WGA Long throw nozzle grille

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Ceiling Slot Diffuser DSC

Ceiling impulse diffuser Model PIL

Ventilation Grille PA

DSC-PLASTER Slot diffuser for plasterboard ceilings

Ceiling Swirl Diffuser DQJ

Air diffuser system Model AUDIX -AW

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-601

Long Throw Nozzle WDA

Lint separator FLARE

LAQ Return air diffuser

Volumetric Flow Limiter VOLKOM

Mechanical mixing box MBM

Particle Filter Box FKU

Weather protection grille ALAS

Slot diffusers, Round duct diffusers. IMP Klima

Technical documentation

Particle Filter Box Model FKF

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

WALL VENTILATION GRILLES CBP

Ventilation grilles for installation into walls, sills or rectangular

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

series 90-GV Variable geometry units

Ventilation grilles for installation into walls, sills or rectangular

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Ceiling swirl diffusers with perforated face plate

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

DRUM SLOT DIFFUSER TYPE: RT350

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Ventilation grilles for installation into walls, sills or rectangular

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Slot diffusers for ceiling installation

Duct Nozzle Diffuser. L e

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Fan coil unit NBS 100/150

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Air Displacement Vent Units

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Ventiduct nozzle ducts

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

For installation into ductwork

Ventiduct nozzle ducts

KLIMA Active Chilled Beams

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Grilles Linear Grilles

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

ACTIVENT System. Specifications. Product code example ACTA

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

CornerAir. CornerAir. Active chilled beam

IMP Klima. Swirl diffusers. Variable swirl diffusers

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Displacement flow diffusers. L e

Catalog Swirl diffuser DAL 359

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

series KLR Linear slot diffusers

Type VSD35. Nominal length up to 1500 mm: one spigot

Catalog Linear Diffuser SAL 50

Floor Swirls Models BZD and SZD

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

CTVK Supply air diffuser

LINEAR SLOT DIFFUSERS

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Transcription:

Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Construction... 3 Model... 3 Accessories... 3 Fastening... 3 Blade adjustment options... 4 Blade position... 4 Models and dimensions...5 Dimensions... 5 Accessories... 6 Technical data...7 Pressure loss and noise level... 7 Maximum end velocity of jet... 8 Maximum penetration... 8 Temperature ratio... 8 Induction ratio... 8 Legend...9 Order details... 10 Specification texts... 11 01/05-2

Description In modern architecture, sheet metal and spiral ducts of air-conditioning systems are often incorporated in the design of the room. Emphasis is often placed deliberately on parts of the supply system. In this visible installation of the ventilation ducts, it is a good idea to integrate the air diffusers into the ducts. In order to be able to offer planners a technically advanced air diffuser, which can also be well integrated into modern architectural concepts, we have developed our round duct diffuser type DBB-RR. The diffuser type DBB-RR consists of a round duct with integrated, linear nozzles, which can also be adjusted by hand on-site, with integrated hit-and-miss damper, which allows the air to be blown absolutely uniformly over the entire diffuser area. The centrally arranged blades in support profile sections ensure that the free cross-section at every blade is the same. As a result, the noise level and pressure are not affected by changing the blade position. In heating mode, this allows a large penetration depth, thus providing an effective, cost-saving heating phase. In cooling mode, the maximum end velocity of jet and temperature difference are reduced to such an extent that no draughts are produced in the occupied zone. This uniform admission allows the round duct diffuser type DBB-RR to be installed at any point along the duct system. Accessories, such as dummy pipes, end covers and connecting sleeves complete the range for this diffuser (See documents: Accessories for round duct systems). For maintenance, service, retrofitting, etc., inspection openings in sufficient number and size must be provided on-site. Model DBB-RR-Z DBB-RR-A Accessories Fastening - Supply air model with air deflection blades. - Return air model without air deflection blades. - Rubber lip seal - on both sides, made of EPDM Other accessories - Separate brochure on request Suspension - Prepared for suspended installation by using an M8 threaded rod to be provided by the customer. Attention! We would like to point out that for cleaning stainless steel models, only suitable cleaning materials may be used! Please note that for vertical throw a distance of at least 100 mm must be available between the weld seam and the diffuser. This means that the weld seam must be offset accordingly. Advantages: - Sound power level and pressure loss remain constant in all blade positions. - Dimensionally stable smooth duct is easy to clean. Construction Blades - Plastic, similar to RAL colour 9010 (white) or RAL 9005 (black) - Aluminium painted to the RAL colour of the faceplate. The painted blades cannot be adjusted subsequently. Round duct - Galvanised sheet steel (-Sv) - Sheet steel painted to RAL 9010 (white) (standard, -St) - Stainless steel 1.4301 (V2A) painted in the colour sand silver (-ES) Hit-and-miss damper - made of the same material as the round duct - Galvanised sheet steel - Stainless steel 1.4301 (V2A) 01/05-3

Blade adjustment options Throw directions (blade position 6 o'clock) one-way horizontal (-He) Blade position 6 o'clock (-6U, standard) two-way horizontal (-Hb) 3 o'clock (-3U) vertical (-V) 9 o'clock (-9U) crosswise (-K) 12 o'clock (-0U) Ex works, the blades are set to the 6 o'clock blade position. On request the blade position "3 o'clock", "9 o'clock" or "12 o'clock", each in the air flow direction, is also available. 01/05-4

Models and dimensions Dimensions DBB-RR Banding from size 500 Detail Y Threaded rod on site M8 riveting nut Only applies to suspended installations from the ceiling: prepared for suspended installation from the ceiling by using an M8 threaded rod to be provided by the customer. Hit-and-miss damper Air flow direction Available sizes NW ød Number of slots along circumference Length L Number of slots 2 4 6 8 10 12 14 lengthwise 200 198 x x - - - - - 224 222 x x - - - - - 500 1 250 248 x x - - - - - 280 278 x x x - - - - 750 2 315 313 x x x - - - - 355 353 x x x x - - - 1000 3 400 398 x x x x - - - 450 448 x x x x - - - 1500 4 500 498 x x x x x x x 560 558 x x x x x x x 1750 5 630 628 x x x x x x x 710 708 x x x x x x x 2000 6 800 798 x x x x x x x 900 898 x x x x x x x x = available - = not available 1-part 2-part 01/05-5

Length of sections 1-part: Length 500 Length 750 Length 1000 2-part: Length 1500 Length 1750 Length 2000 Round duct diffusers having a length of > 1000 mm are produced in two sections and joined at the factory using a sleeve. The dimensions of the dummy pipes are the same as the dimensions of the diffuser type DBB-RR. A different length of sections is possible on request. However, the maximum length for a middle or end piece is 1000 mm. Accessories - Rubber lip seal 01/05-6

Technical data Pressure loss and noise level OPEN OPEN OPEN OPEN = hit-and-miss damper position Correction factor pressure loss and noise level V Stirn = V zu (m³/h) : (FQ x 3600 x KF) NW V ZU FQ (m²) Length KF (at v K =1 m/s) Number of slots along circumference L (m³/h) [l/s] 2 4 6 8 10 12 14 200 108 30 0,01 0,02 - - - - - 224 139 39 0,01 0,02 - - - - - 500 x 0.5 250 174 48 0,01 0,02 - - - - - 280 219 61 0,01 0,02 0,03 - - - - 750 x 0.75 315 277 77 0,01 0,02 0,03 - - - - 355 356 99 0,01 0,02 0,03 0,04 - - - 1000 x 1.00 400 448 124 0,01 0,02 0,03 0,04 - - - 450 567 158 0,01 0,02 0,03 0,04 - - - 1500 x 1.5 500 701 195 0,01 0,02 0,03 0,04 0,05 0,06 0,07 560 978 272 0,01 0,02 0,03 0,04 0,05 0,06 0,07 1750 x 1.75 630 1115 310 0,01 0,02 0,03 0,04 0,05 0,06 0,07 710 1417 394 0,01 0,02 0,03 0,04 0,05 0,06 0,07 2000 x 2.0 800 1801 500 0,01 0,02 0,03 0,04 0,05 0,06 0,07 900 2280 633 0,01 0,02 0,03 0,04 0,05 0,06 0,07 Correction factor pressure loss and noise level for DBB-RR without hit-and-miss damper L WA 100% OPEN x 0,877 Δp t 100% OPEN x 0,78 1-part 2-part 01/05-7

Maximum end velocity of jet Temperature ratio one-way horizontal throw Correction factormaximum end velocity of jet Number of slots along circumference 2 4 6 8 10 12 14 one-way horizontal x1 x1.2 x1.4 x1.68 x2.02 x2.42 x2.88 horizontal left / right x0.58 x0.72 x0.8 x0.96 x1.17 x1.39 x1.67 Maximum penetration Induction ratio one-way horizontal throw Correction factor max. penetration Number of slots along circumference 2 4 6 8 10 12 14 vertical x1 x1.17 x1.36 x1.59 x1.86 x2.18 x2.56 crosswise x1.2 x1.44 x1.73 x2.08 x2.49 x2.99 x3.58 01/05-8

Legend V ZU (m³/h/m/2s) = Supply air volume per meter per 2 slots V ZU [l/s/m/2s] = Supply air volume per meter per 2 slots V X (m³/h) [l/s] = total air jet volume at point x Δp t (Pa) = Pressure loss v stirn (m/s) = Intake velocity, blower stream velocity, outflow velocity, relative to A stirn v max (m/s) = Maximum end velocity of jet v K (m/s) = Duct velocity L WA [db(a)] = A-weighted sound power level x+y (m) = Horizontal + vertical throw y H (m) = Maximum penetration in heating mode ΔT O (K) = Temperature difference between supply air temperature and room temperature (ΔT O = t ZU - t R ) ΔT X (K) = Temperature difference at point x t zu ( C) = Supply air temperature t R ( C) = Room temperature i (-) = Induction ratio (i = V X / V ZU ) TV (-) = Temperature ratio (TV = ΔT X / ΔT O ) KF (-) = Correction factor FQ (m²) = Free cross-section NW = Nominal width SU = Number of slots along circumference 01/05-9

Order details Round duct diffuser DBB-RR Round duct made of of Galvanised sheet sheet steel painted steel to RAL painted 9010to (white, RAL standard) 9010 (white, -St standard) Round duct made of Sheet steel galvanised -SV Round duct made of Stainless steel 1.4301 (V2A) -ES with hit-and-miss damper Supply air -Z with blades Return air -A without blades made of plastic similar to colour RAL 9010 (white) - LW similar to colour RAL 9005 (black) - LS made of aluminum painted (to the RAL colour of the round duct) - LA horizontal one-way -He Blade adjustment options (outflow directions) horizontal two-way -Hb vertical -V crosswise -K 3 o'clock -3U Mounting position 6 o'clock -6U 9 o'clock -9U 12 o'clock -0U 500-0500 Length 1-part 750-0750 1000-1000 1500-1500 Length 2-part 1750-1750 2000-2000 NW 200 224 250 280 315 355 400 450 500 560 630 710 800 900 Accessories: Rubber lip seal -GD Order example: DBB-RR-St-Z-LS-Hb-6U-1000-400 Unless stated otherwise, the thick-frame model will be delivered. 01/05-10

Specification texts Round duct diffuser suitable for connection to DIN ducts. With integrated, manually adjustable air deflection blades in support blade profile form made of plastic, similar to RAL colour 9010 (white), RAL 9005 (black) or aluminium painted to the RAL colour of the round duct (subsequent adjustment of blades not possible). Sound power level and pressure loss remain constant in all blade positions. With integrated hit-and-miss damper for simple air volume regulation and ductwork regulation, made of the material the round duct is made of. Product: SCHAKO type DBB-RR-Z - for return air, without air deflection blades Product: SCHAKO type DBB-RR-A - Round duct made of - Galvanised sheet steel (-Sv) - Sheet steel painted to RAL 9010 (white) (standard, -St) - Stainless steel 1.4301 (V2A) painted in the colour sand silver (-ES) - Blade position - 3 o'clock (-3U) - 6 o'clock (-6U, standard) - 9 o'clock (-9U) - 12 o'clock (-0U) - Blade adjustment options (throw directions) - one-way horizontal (-He) - two-way horizontal (-Hb, standard) - vertical (-V) - crosswise (-K) - Length - 1-part: 500 / 750 / 1000 (-0500/-0750/-1000) - 2-part: 1500 / 1750 / 2000 (-1500/-1750/-2000) Accessories (at an extra charge): - Rubber lip seal - on both sides, made of EPDM 01/05-11