Product Selection Guide. We provide superior filtration solutions to improve the quality of life

Similar documents
PRODUCT SELECTION GUIDE FILTRATION SOLUTIONS TO IMPROVE THE QUALITY OF LIFE

F 45 R REVERSE POCKET FILTERS

Maxi-Grid. A Complete Line of Internally-Supported Panel Filters. Koch Filter Corporation

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Our COmpany... Our products ExCEllEnCE in CuSTOmEr SErviCE...

PANEL & CARTRIDGE FILTERS

Our heritage enables us to take a small company approach to the day to day activities of each and every customer.

Excelair. Every filter is created to perfection!

WELCOME. Give us a call.

1 of 8. Air Solutions Sdn. Bhd. Euro Carb. Box Type Chemical Filter

Complete Line of Airguard Synthetic Bag Filters

TRI-DEK FILTERS OVER 40 YEARS OF INNOVATION

ALL PRODUCTS BROCHURE

PAINT BOOTHS ARRESTORS

Bard Throw-Away and Permanent Air Filter Specifications. Bard offers a wide selection of permanent and replaceable filters for various applications.

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II

PAINT BOOTHS ARRESTORS

PAINT BOOTHS ARRESTORS

Filtration Equipment

microns microns 70% 85%

THE WORLD LEADER IN CLEAN AIR SOLUTIONS. (Low Pressure Drop, High Capacity)

Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258

INNOVATIVE FILTRATION SOLUTIONS

EZ FLOW II FIBERGLASS FILTER

nivia utilities Why Air Filters???

ALL PRODUCTS BROCHURE

WORLD STAR ENGINEERING

Creating Clean Air. A Product Guide. Taking small steps together, always ahead, towards a better world

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

SPECIFICATION FOR FILTERS, AIR (HVAC) (This specification is released for procurement purposes until revised or rescinded.)

FlowAir CATALOG.

Filtration Solutions Edition. Fort Myers 6461 Topaz Court Fort Myers, FL Tel: (239) Fax: (239)

SECTION HVAC AIR CLEANING DEVICES

Shenzhen Xiangnan High-Tech Purify Equipment Co., Ltd

Airpocket Select Ultrasonically-sealed

TECHNICAL DATA. Replacement Elements. Standard Replacement Elements. Solberg Replacement Elements

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

Downflo workstation DuSt ColleCtorS

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

DOWNFLO II DUST COLLECTORS

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

downflo workstation dust collectors

Table of Contents. Panel Filters Deep Bed Bag Filters Magnehelic Gauges HEPA Filters & Modules Grease Filters...

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

the filter and hvac store

Inlet House Air Filters Presented By: Zahi Youwakim

Compact Finedust / HEPA Filter

Proprietary technology that performs

quatroair.com AIR TECHNOLOGIES INC.

AstroCel. Better Air is Our Business ss. High Efficiency Particulate Air Filters (HEPA) Ultra Low Penetration Air Filters (ULPA)

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Air Boss M-Series Media & Adsorption Air Cleaner

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

Britannia FM Supplies Ltd. Product catalogue. Filters for air conditioning technology Filters for painting and drying technology

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION HVAC AIR CLEANING DEVICES

Your Filtration Solution Provider, Offering Value with Choice.

FILTRATION FOR ANY APPLICATION

UltraWebisAlwaysBetter.com

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

Efficiency powered to infinity. Nederman Filtac oil mist filters for continuous operation

A GLOBAL POWER EQUIPMENT GROUP COMPANY

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

Specialists in HEPA Filtration and Negative Air Machines

Meltblown. sawascreen

...And Watch Your Grow!

TOTALINE ELECTRONIC AIR CLEANERS

Cleaner Air Comes From Within

ASHRAE GAS-PHASE AIR CLEANER TEST REPORT. Test Laboratory: RTI 3040 Cornwallis Road Research Triangle Park, NC

Looks like a safe because it s built like a safe. Gold Series. Farr APC. Gold Series Brochure. Air Pollution Control

PROPRIETARY TECHNOLOGY THAT PERFORMS

PROPRIETARY TECHNOLOGY THAT PERFORMS

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

XLR TM. Next generation air filtration

CRYSTAL-AIRE. concealed commercial air cleaners

Splash-proof Terminal HEPA Filter

PRODUCT SELECTOR GUIDE

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

PLEATED BAG FILTERS WITH ULTRA-WEB

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

Denray Machine s Product Catalog

Downflo Systems. Containment. With Triple-Sealed Bag-In/Bag-Out for filters and hopper discharge

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

FILTRATION TECHNOLOGY FOR THE GRAIN INDUSTRY

PRODUCT BROCHURE Universal duct air filter DELBAG MultiMaster-Vario. More versatile by variable adaptation

There are two general ways to capture airborne pollutants:

DOWNFLO EVOLUTION DUST COLLECTORS

Torit PowerCorE. VH Series

PLEATED BAG FILTERS WITH ULTRA-WEB

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax F. Modular dust collector with integrated pre-separator. Models

Pleated bag filters With ultra-web sb

AS , EN12469 (Microbiological Testing Method)

Transcription:

Product Selection Guide We provide superior filtration solutions to improve the quality of life REVISION JANUARY 2010

The viledon difference In today s complex world, it takes an equally complex combination of intelligence, commitment and scientific resources to solve air filtration problems. For more and more companies faced with such problems...viledon is not just a product. It s a total solution. viledon air filtration products are designed to meet the requirements of specific applications from the development of custom-made media through to the finished product.

Our committment to you... When a market need arises, viledon s media scientists and filter design engineers work in concert to develop a comprehensive solution to the problem. All the resources required to generate such solutions regardless of their complexity are available within the Freudenberg Filtration Technologies organization. No other manufacturer has the depth of experience and scientific expertise in place to make this level of commitment.

Blue is the new Green! GREENGUARD

First in Blue viledon celebrates its 50 year history of leadership by moving the industry toward a healthier IAQ solution. Contact viledon to help you select the right filter product for your green building needs. First in Green All viledon filters approved and recognized by Greenguard s stringent testing methods: Microbial Resistant (Tested to ASTM D 6329-98) Low Emitting and Sustainable

Cut Pads, Slit Rolls, Bulk Rolls, Panels & Links P15 (150S/350S/500S) Prefiltration for general equipment and HVAC systems High humidity prefiltration 100% washable MERV Rating (150S-3, 300S-5, 500S-6) Inchs WG 400 800 1200 1600 2000 Air Flow (CFM) P15/500 S P15/350S P15/150S PSB (145S/275S/290S) Prefiltration for general equipment and HVAC systems Progressively structured media UV Resistant Media MERV Rating (145S-3, 275S-5, 290S-6) Inchs WG 400 800 1200 1600 2000 Air Flow (CFM) PSB/290S PSB/275S PSB/145S R2/3- R2/4 Prefiltration for general equipment and HVAC systems Welded 10 gauge steel frame for Panels & Links Triple layer progressively structured media made from synthetic fibers Thermally bonded with tackifier High humidity environments SC: Scrim option available viledon Migration Test Rating- S2 WinAir Panel Prefiltration for general equipment and HVAC systems Multi-Layered media Adhesive tackifier viledon Migration Test Rating- S2 0.18 0.12 0.04 0.02 0.34 0.28 0.24 0.12 0.09 0.03 50 100 150 200 250 300 350 400 450 500 Air Flow Rate (FPM) 0.18 0.11 0.02 50 100 150 200 250 300 Air Flow Rate (FPM) Performance Unit P15 PSB Style 150S 300S 500S 145S 275S 290S R2/3-R2/4 WinAir Nominal Media Velocity FPM 400 300 200 400 300 200 500 FPM 100 FPM Initial Resistance w.g..08.10.12.08.08.10.40.05 Max Temperature F 212 Peaks@250 MERV/viledon Migration Test 1-16 3 5 6 3 5 6 S2 S2 Nominal Thickness in 1/4 1/2 3/4 3/8 5/8 7/8 1 1/4 1 Size Availability Cut Pads,Slit Rolls & Bulk Rolls Cut Pads, Slit Rolls, Bulk Rolls, Panels & Links Panels & Links UL 900 Classification Class2 Not Classified Class 1 Not Classified

High Efficiency Diffusion Media R1, R1SC Final filtration for crossdraft and down-draft paint spray booths Prefiltration for general equipment and HVAC systems Equipment protection Special adhesive tackifier Progressively structured SC: Scrim option available viledon Migration Test Rating- S1 0.24 0.18 0.12 0.03 50 100 150 200 250 Air Flow Rate (FPM) PA/560 G-10 Final filtration (ceiling media) for crossdraft and down-draft paint spray booths Proprietary tackification process Progressively structured viledon Migration Test Rating-S0 0.6 0.5 0.4 0.3 0.2 0.1 0 0.48 0.42 0.34 0.28 0.22 0.1 25 50 75 100 125 150 175 200 Air Flow Rate (FPM) PA-5micron Final filtration (ceiling media) for crossdraft and down-draft paint spray booths Proprietary tackification process Progressively structured Increased pressure drop to enhance laminar, even flow pattern viledon Migration Test Rating-S0 0.90 0.83 0.72 0.63 0.52 0.44 0.29 0.22 0.12 25 50 75 100 125 150 175 200 Air Flow Rate (FPM) Performance Unit R1-R1SC PA/560 G-10 PA-5micron Rated Air Flow FPM 100 Initial Resistance w.g..07.22.44 Max Temperature F 212 Peaks@250 viledon Migration Test rating S1 S0 S0 Nominal Thickness in 3/4 1 1 1/4 Size Availability Cut Pads, Slit Rolls, Bulk Rolls, Panels & Links UL 900 Classification Class1 Class1 Class1 Robotic Zone (50/75 fpm) (Initial Resistance) w.g. N/A (.10/.15) (.22/.29)

Medium Efficiency Filters WinAir Pleat General HVAC filtration Prefilter for second stage of high-efficiency filters Standard sizes available MERV Rating 7 0.41 0.33 0.27 0.23 0.02 0.03 WinAir Pleat 2" WinAir 4" Pleat MINI RF General HVAC filtration Gas Turbine Prefilter Prefilter for second stage of high-efficiency filters Standard sizes available All plastic construction Washable MERV Rating 7 R1/ES3 General HVAC filtration Prefiltration for high efficiency filters 2 layer progressive media Adhesive tackifier LEED Construction minimum filtration MERV Rating 8 F45S General fine filtration for HVAC where depth is restricted Gas Turbine Prefilter Prefilter for second stage of high-efficiency filters Low pressure drop LEED Construction minimum filtration MERV Rating 8 0.12 0.04 0.02 0.12 0.09 0.04 0.04 0.02 0.02 0 0.34 0.17 0.04 0.18 0.11 0.02 Performance Unit WinAir Pleat MINI RF 2 4 2 4 R1/ES3 F45S Rated Air Flow CFM 1968 1968 1968 Initial Resistance w.g..23.27.10.09.25.18 Max Temperature F 160 Peaks@200 212 Peaks@250 160 Peaks@200 Final Resistance w.g. 1.00 1.00 1.50 1.50 1.50 1.50 MERV@1968 1-16 7 7 7 7 8 8 UL 900 Classification Class2 Class2 Class1 Class1 Class2 Class2 Burst Strength w.g. >2 >2 >4 >4 >4 >12

WinAir Pocket Filters WinAir 75 Final/Prefiltration for general equipment and HVAC systems Dual-Layer synthetic media Non-shedding synthetic fibers Resistant to moisture and chemicals MERV Rating 12 0.34 0.26 0.18 0.11 WinAir 85 Final filtration for general equipment and HVAC systems Dual-Layer synthetic media Non-shedding synthetic fibers Resistant to moisture and chemicals MERV Rating 14 DISCONTINUED NOVEMBER 1ST 2009 0.19 WinAir 95 Final filtration for general equipment and HVAC systems Dual-Layer synthetic media Non-shedding synthetic fibers Resistant to moisture and chemicals MERV Rating 14 0.52 0.39 0.26 Performance Unit WinAir 75 WinAir 85 WinAir 95 Rated Air Flow CFM 1968 Initial Resistance w.g..26.40.39 Max Temperature F 150 Final Resistance w.g. 1.50 MERV@1968 1-16 12 14 14 ASHRAE 52.1 Equivalent Efficiency* % 70-75% 90-95% 90-95% UL 900 Classification Class2 Burst Strength w.g. >9

Medium Efficiency Pocket Filters F50 General fine filtration for HVAC systems High humidity prefiltration General gas turbine prefiltration Prefiltration for industrial paint spray booths Prefilter for second stage of high-efficiency filters Self-Supporting pocket filter MERV Rating 9 T60 General fine filtration for HVAC systems Gas turbine prefiltration Prefiltration in industrial paint spray booths Solid/liquid separation, demisting and salt coalescing Self-Supporting pocket filter MERV Rating 10 0.02 0.29 0.21 0.09 GF55 General fine filtration for HVAC systems Gas Turbine prefiltration Prefiltration in industrial paint spray booths Non-Migrating adhesive tackifier for environments with high concentration of non-sticky dust. Self-Supporting pocket filter MERV Rating 9 GF65 General fine filtration for HVAC systems Gas turbine prefiltration Prefiltration in industrial paint spray booths Non-Migrating adhesive tackifier for environments with high concentration of non-sticky dust. Self-Supporting pocket filter MERV Rating 9 MINIMUM ORDER REQUIRED- PLEASE SEE VILEDON REPRESENTATIVE 0.03 0.21 MINIMUM ORDER REQUIRED- 0.11 PLEASE SEE VILEDON REPRESENTATIVE 0.02 Performance Unit F50 T60 GF55 GF65 Rated Air Flow CFM 1968 Initial Resistance w.g..14.21.15.16 Max Temperature F 160 Peaks@200 Final Resistance w.g. 1.50 MERV@1968 1-16 9 10 9 9 UL 900 Classification Class2 Burst Strength w.g. >12

High Efficiency Pocket Filters MF70 General fine filtration for HVAC systems 3 layer progressively structured media Prefiltration in industrial paint spray booths LEED occupied building minimum filtration MERV Rating 13 0.22 0.19 MF90 Ultrafine synthetic filtration for HVAC systems pharmaceuticals, electronics, gas turbine fine filtration, and industrial paint spray booths Prefilters for HEPA filters VOC abatement systems MERV Rating 14 0.47 0.36 MF95 Ultrafine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Final filters on air discharged to environment Prefilters for HEPA filters MERV Rating 16 (highest MERV rating of any pocket filter) 0.67 0.36 0.23 0.13 Performance Unit MF70 MF90 T98 MF95 Rated Air Flow CFM 1968 Initial Resistance w.g..23.36.38.50 Max Temperature F 160 Peaks@200 Final Resistance w.g. 1.50 1.50 1.50 1.50 MERV@1968 1-16 13 14 15 16 ASHRAE 52.1 Equivalent Efficiency* % 85-90% 90-95% >95% UL 900 Classification Class2 Burst Strength w.g. >12

High Efficiency Extended MINI Surface Filters MINI 75 Compact design for air handlers with space restrictions Fine filtration in HVAC Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Gas turbine prefiltration All plastic light-weight construction MERV Rating 12 MINI 85 Compact design for air handlers with space restrictions Fine filtration in HVAC Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths All plastic light-weight construction LEED occupied building minimum filtration MERV Rating 13 MINI 95 Compact design for air handlers with space restrictions Fine filtration in HVAC Ultra Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths All plastic light-weight construction MERV Rating 14/15 1.00 0.90 1.00 0.90 0.17 0.11 0.04 0.12 0.03 0.12 MINI 75 2" MINI 75 4" 0.19 0.11 0.21 0.12 MINI 85 2" MINI 85 4" 0.33 0.21 MINI 95 2" MINI 95 4" 0.26 0.19 0.3 0.34 0.22 0.34 0.28 0.56 0.39 Performance Unit MINI 75 MINI 85 MINI 95 2 4 2 4 2 4 Rated Air Flow CFM 1968 Initial Resistance w.g..25.16.26.19.45.30 Max Temperature F 160 Peaks@175 Final Resistance w.g. 1.50 MERV@1968 1-16 12 12 13 13 14 15 ASHRAE 52.1 Equivalent Efficiency* % 70-75% 85-90% 90-95% UL 900 Classification Class1 Burst Strength w.g. >4

WinAir MVP High Efficiency Extended Surface V-Style Filters MVP12 Nano Proprietary hybrid synthetic media filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction MERV Rating 12 MVP75 Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, gas turbine prefiltration and industrial paint spray booths Fully potted construction MERV Rating 12 MVP85 Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction LEED occupied building minimum filtration MERV Rating 13 MVP95/MVPFR95 (UL 900 Class 1) Ultrafine synthetic filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction UL 900 Class 1 MERV Rating 15 0.41 0.31 0.22 0.39 0.28 0.18 0.39 0.28 0.18 0.46 0.33 0.22 0.12 Performance Unit MVP 12 MVP 75 MVP 85 MVP 95 MVPFR95 Rated Air Flow CFM 1968 Initial Resistance w.g..31.28.28.46.46 Max Temperature F 160 Peaks@175 Final Resistance w.g. 1.50 MERV@1968 1-16 12 12 13 15 15 ASHRAE 52.1 Equivalent Efficiency* % 70-75% 80-90% >95% >95% UL 900 Classification Class2 Class1 Burst Strength w.g. >12

High Efficiency Extended Surface V-Style Filters MV75 Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, gas turbine prefiltration, and industrial paint spray booths Fully potted construction Patented 1 Recess MERV Rating 12 1.00 0.90 0.04 0.22 MV85 Fine synthetic filtration for HVAC systems pharmaceuticals, electronics, gas turbines, and industrial paint spray booths Fully potted construction Patented 1 Recess LEED occupied building minimum filtration MERV Rating 13 1.00 0.90 0.22 0.04 MV95/MVFR95 Ultrafine synthetic filtration for HVAC systems pharmaceuticals, electronics, gas turbine fine filtration, and industrial paint spray booths Fully potted construction Patented 1 Recess MERV Rating 16 1.00 0.90 0.41 0.31 0.22 Performance Unit MV75 MV85 MV95 MVFR95 Rated Air Flow CFM 1968 Initial Resistance w.g..21.23.31.31 Max Temperature F 160 Peaks@175 Final Resistance w.g. 1.50 MERV@1968 1-16 12 13 16 16 ASHRAE 52.1 Equivalent Efficiency* % 70-75% 80-90% >95% >95% UL 900 Classification Class2 Class1

High Efficiency MV Nano Extended Surface V-Style Filters MV12 Proprietary hybrid synthetic media filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction Patented 1 Recess MERV Rating 12 0.03 0.13 0.27 MV13 Proprietary hybrid synthetic media filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction Patented 1 Recess LEED occupied building minimum filtration MERV Rating 13 0.43 0.33 0.23 MV15/MVFR15 (UL 900 Class 1) Proprietary hybrid synthetic media filtration for HVAC systems pharmaceuticals, electronics, and industrial paint spray booths Fully potted construction Patented 1 Recess UL900 Class 1 MERV Rating 15 0.51 0.29 0.19 0.09 Performance Unit MV12 MV13 MV15 MVFR15 Rated Air Flow CFM 1968 Initial Resistance w.g..20.33.40.40 Max Temperature F 160 Peaks@175 Final Resistance w.g. 1.50 MERV@1968 1-16 12 13 15 15 ASHRAE 52.1 Equivalent Efficiency* % 70-75% 80-90% >95 >95 UL 900 Classification Class2 Class1

High Efficiency Compact and Rigid Filters MX95 Ultrafine filtration for HVAC systems pharmaceuticals, electronics, gas turbine fine filtration, and industrial paint spray booths Prefiltration for HEPA and ULPA filters VOC abatement systems Single header, Double header and Box Style available MERV Rating 14 0.37 MX98 Ultrafine filtration for HVAC systems pharmaceuticals, electronics, gas turbine fine filtration, and industrial paint spray booths Prefiltration for HEPA and ULPA filters VOC abatement systems Single header, Double header and Box Style available MERV Rating 15 0.59 0.44 0.18 MX100 Ultrafine filtration for HVAC systems pharmaceuticals, electronics, gas turbine fine filtration, and industrial paint spray booths Prefiltration for HEPA and ULPA filters VOC abatement systems Single header, Double header and Box style available MERV Rating 16 1.40 1.20 1.00 1.24 0.96 0.46 0.21 Performance Unit MX95 MX98 MX100 Rated Air Flow CFM 1968 1968 1968 Initial Resistance w.g..37.44.96 Max Temperature F 160 Peaks@175 Final Resistance w.g. 1.50 1.50 1.50 MERV@1968 1-16 14 15 16 ASHRAE 52.1 Equivalent Efficiency* % 80-90% >95% >99% Burst Strength w.g. >10 >10 >10

Depth Loading Cartridge Filters TFP 90 Designed for use in supply air systems for gas turbines and turbocompressors Provides favorable pressure drops over maximized useful lifetime Achieves an optimum ratio between filtering area, pleat depth and number of pleats TFP 90 exceeds 25 w.g. in the 72 hour wet breech test TFP 90 IS NOT DESIGNED FOR PULSING. MERV Rating 16 0.76 150 300 450 600 750 TFP 90P Is designed for demanding corrosive environments. Plastic non-corrosive end caps and stainless steel internal liner. Achieves an optimum ratio between filtering area, pleat depth and number of pleats TFP 90 exceeds 25 w.g. in the 72 hour wet breech test TFP 90 IS NOT DESIGNED FOR PULSING. MERV Rating 16 0.76 150 300 450 600 750 GTC 90P Is designed for demanding corrosive environments. Plastic non-corrosive end caps and stainless steel internal liner. Achieves an optimum ratio between filtering area, pleat depth and number of pleats GTC 90P is Viledon s non-corrosive pulsable cartridge filter. MERV Rating 12 2.00 1.80 1.60 1.40 1.20 1.00 1.58 1.10 0.71 408 815 1223 1630 2038 Performance Unit TFP90 TFP90P GTC90P Rated Air Flow CFM 600 600 1630 Initial Resistance w.g..50.50 1.10 Max Temperature F 160 Peaks@175 160 Peaks@175 160 Peaks@175 Final Resistance w.g. 3.20 3.20 4.0 MERV@1968 1-16 16 16 12 ASHRAE 52.1 Equivalent Efficiency* % >95% >95% 70-75% Burst Strength w.g. 25 25 25 Corrosion Resistant NO YES YES Torque Recommendations ft/lbs 4 4 10

High Temperature Filters LH1000 High temperature filtration of recirculated air in curing ovens Glass fiber media enclosed in expanded metal protection grid Two-stage filtration High-humidity applications 30 per carton 100 200 300 400 500 600 700 Performance Unit LH1000 Rated Air Flow CFM 600 Initial Resistance w.g..30 Max Temperature F 575 F Final Resistance w.g. 1.0 Weight oz. 10 Depth in.55

High Efficiency Extended Surface Carbon Filters DuoPleat Ultrafine odor filtration for HVAC systems pharmaceuticals and electronics Eliminate pollutant gases, unwanted odors Activated-carbon media MERV Rating 15 1400 1200 1000 800 600 400 200 0 Toluene SO² Butane NOX CarboPleat Odor elimination for HVAC systems pharmaceuticals and electronics High humidity prefiltration General prefiltration MERV Rating 8 0.42 0.38 0.32 0.28 0.23 0.18 0.13 0.11 0.04 500 1000 1500 2000 2500 DP CP MINI CP Odor elimination for HVAC systems pharmaceuticals and electronics High humidity prefiltration General prefiltration MERV Rating 7 800 700 0.29 0.2 0.13 0.04 0.03 Mini CP 4" Mini CP 2" 600 500 400 300 200 100 0 Toluene SO² Butane NOX Mini CP 2" Mini CP 4" Performance Unit CarboPleat DuoPleat MINI CP 2 4 Rated Air Flow CFM 1968 1968 1968 1968 Initial Resistance w.g..28.32.20.35 Thermal Stability F 160 Final Resistance w.g. 1.50 MERV@1968 1-16 8 15 7 7 ASHRAE 52.1 Equivalent Efficiency* % 30-35% >95 25-30% 25-30%

Freudenberg Filtration Technologies LP 2975 Pembroke Road Hopkinsville, Ky 42240 Tel: 1-270-887-5145 Fax: 1-270-890-0743 www.freudenberg-filter.com Distributed By: