Thermal overload relay TF140DU and TF140DU-V1000

Similar documents
Thermal overload relay TF65 and TF96

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter magnetic only MO325

Manual motor starter MS116

Manual motor starter MS116

Manual motor starter MS132

Mini contactors B6, BC6 with 3 pole

Thermal Overload Relays

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

MS General Information Extended Product Type: MS

Manual motor starters Overview and benefits

Selective main circuit breakers S 750 series Technical Data

AF40... AF96 3-pole contactors Technical data

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

TA25DU0.4 Overload Relay a. Features. Descriptions

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ABB i-bus KNX DG/S x DALI-Gateway Basic

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Short form catalogue Motor protection and control Manual motor starters

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Overloadrelay,10-16A,1N/O+1N/C. Articleno

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

SIRIUS 3RU2 Thermal Overload Relays

Short form catalogue. Motor protection & control

Data Sheet Manual Motor Starters Ex9SN Series

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Mini Contactors Applications and Segments

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ASL09..S 3-pole Contactors - Spring Terminals

ZS50-PE Screw Clamp Terminal Blocks Ground

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

E16DU, E45DU, E80DU, E140DU electronic overload relays 0.10 to 140 A

DBL distribution blocks 3x1 pole

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Bulletin 193-T1 Bimetallic Overload Relays

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4 Screw Clamp Terminal Blocks Feed-through

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

B Mini Contactor V Hz

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Protection Equipment

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS6 Screw Clamp Terminal Blocks Feed-through

Panorama. Contactors Motor protection Accessories

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-PE Screw Clamp Terminal Blocks Ground

Transcription:

Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and phase failures. Starter combinations are setup together with contactors. 2CDC231007V0013 Description Overload protection trip class 10A Phase loss sensitivity Temperature compensation from -25 +55 C Adjustable current setting for overload protection Automatic or manual reset selectable Trip-free mechanism Status indication STOP and TEST function Direct mounting onto block contactors Order data TF140DU and TF140DU-V1000 screw terminals For AF contactors Setting range Type Order code Packing unit Weight per PCE A PCE kg 66... 90 TF140DU-90 1SAZ431201R1001 1 0.820 80... 110 TF140DU-110 1SAZ431201R1002 1 0.820 100... 135 TF140DU-135 1SAZ431201R1003 1 0.820 110... 142 TF140DU-142 1SAZ431201R1004 1 0.820 66... 90 TF140DU-90 -V1000 1SAZ431301R1001* 1 0.820 80... 110 TF140DU-110-V1000 1SAZ431301R1002* 1 0.820 100... 135 TF140DU-135-V1000 1SAZ431301R1003* 1 0.820 110... 142 TF140DU-142-V1000 1SAZ431301R1004* 1 0.820 * With ATEX certification Suitable for mounting on: AF116, AF140

Functional description 1 1 Terminals 1L1, 3L2, 5L3 2 TEST 3 Current setting range Adjustable current setting for overload protection 2CDC232025F0013 2 3 4 5 6 7 8 9 4 RESET Automatic or manual reset selectable 5 RESET-STOP or RESET selectable 6 Status indication 7 Tripping contacts 95-96 8 Signaling contacts 97-98 9 Terminals 2T1, 4T2, 6T3 Application / internal function The thermal overload relays are three pole relays with bimetal tripping elements (1 per pole). The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements become bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). The contact 95-96 is used to control the load contactor. The overload relays have a setting scale in Amperes, which allows the direct adjusting of the relay without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current). The relays are constructed in way that they protect themselves in the event of an overload. The overload relay has to be protected against short-circuit. The appropriate short-circuit protective devices are shown in the table. Operation mode 1~ 3~ 2CDC232001F0010 2-2CDC106061D0201

a Relay tripped Relay not tripped Press blue button Contacts Manual RESET Automatic RESET Manual RESET Automatic RESET 95-96 97-98 Button R - RESET function 95-96 closes when button is pressed 97-98 s when button is pressed - - - - - - Button R/0 - RESET and STOP function 95-96 closes, when button is released - s when button is pressed, closes when button is released s when button is pressed, closes when button is released 97-98 s, when button is pressed - - - TEST 95-96 97-98 - -, while TEST is operated Wiring diagram R 95 97 2/T1 4/T2 6/T3 96 98 2CDC232002F0011 Resistance and power loss per pole and short-circuit protective devices Type Setting range Resistance per pole Power loss per pole Short-circuit protective device coordination type 2 lower value A upper value A mω at lower value W at upper value W TF140DU-90 / TF140DU-90-V1000 66 90 0.540 2.4 4.4 200 A, Fuse type gg TF140DU-110 / TF140DU-110-V1000 80 110 0.378 2.4 4.6 224 A, Fuse type gg TF140DU-135 / TF140DU-135-V1000 100 135 0.318 3.2 5.8 224 A, Fuse type gg TF140DU-142 / TF140DU-142-V1000 110 142 0.255 3.1 5.1 250 A, Fuse type gg Technical diagrams Intermittent periodic duty (Op/h) 140 120 100 switching frequency 80 60 40 20 t a = 3 s t a = 1.5 s t a = 5 s t a = 1 s t = 0.5 s 0 0 20 40 60 80 100 (%) duty ratio 2CDC232004F0214 Motor starting time 2CDC106061D0201-3

Dimensions 89 3.5" 29.75 1.17" 29.75 1.17" 6.4 3.5" 19.9 0.78" 4 0.16" 37 1.46" 5.5 0.22" 13.45 0.53" 51 2.01" 98 97 96 95 73.8 2.91" 140 5.51" 67.3 2.65" 82.3 3.24" 2/T1 4/T2 6/T3 25 0.98" 25 0.98" 8 0.31" 58.8 2.31" 126 4.96" 6 0.24" 5.3 0.21" 50 1.97" 68 2.68" 80 3.15" 84.2 3.31" 2CDC232008F0012 TF140DU / TF140DU-V1000 4-2CDC106061D0201

Technical data IEC/EN Data at T A = 40 C and at rated values, if nothing else indicated Main circuit 2T1-4T2-6T3 Rated operational voltage U e 690 V AC - V DC Setting range - thermal overload protection see table on page 1 Rated operational current AC-3 I e see upper value of setting range, table on page 3 Trip class 10A Rated frequency 50/60 Hz Number of poles 3 Resistance per pole see table on page 3 Power loss per pole see table on page 3 Short-circuit protective devices see table on page 3 Isolation data 2T1-4T2-6T3 Rated impulse withstand voltage U imp 8 kv Rated insulation voltage U i 690 V Pollution degree 3 Overvoltage category up to III Electrical connection Connecting capacity solid 1/2 x 16... 70 mm² stranded 1/2 x 16... 70 mm² flexible with ferrule 1/2 x 16... 70 mm² flexible with ferrule insulated 1/2 x 16... 70 mm² flexible without ferrule 1/2 x 16... 70 mm² Stripping length 25 mm Tightening torque 8 10 Nm Recommended screw driver M8 Hexagon 2CDC106061D0201-5

Auxiliary circuit 95-96, 97-98 Rated operational voltage U e 500 V AC, 440V DC Conventional free air thermal current I th NC/NO 10 A / 6 A Rated frequency Number of poles Rated operational current I e acc. to IEC/EN 60947-5-1 for utilization category 50/60 Hz 1NC + 1NO at AC-15 at 110-120 V NC, 95-96 3.00 A 1.50 A at AC-15 at 220-230-240 V NC, 95-96 3.00 A 1.50 A at AC-15 at 440 V NC, 95-96 1.00 A 1.00 A at AC-15 at 480-500 V NC, 95-96 1.00 A 1.00 A at DC-13 at 24 V NC, 95-96 1.25 A 1.25 A at DC-13 at 60 V NC, 95-96 0.25 A 0.25 A at DC-13 at 110-120-125 V NC, 95-96 0.25 A 0.25 A at DC-13 at 250 V NC, 95-96 0.12 A Minimum switching capacity 0.04 A 17 V / 3 ma Short-circuit protective devices NC, 95-96 10 A, Fuse type gg 6 A, Fuse type gg Isolation data 95-96, 97-98 Rated impulse withstand voltage U imp 6 kv Rated insulation voltage U i 690 V Pollution degree 3 Overvoltage category up to III Electrical connection 95-96, 97-98 Connecting capacity solid 1/2 x 0.75... 4 mm² stranded 1/2 x 0.75... 4 mm² flexible with ferrule 1/2 x 0.75... 2.5 mm² flexible with ferrule insulated 1/2 x 0.75... 2.5 mm² flexible without ferrule 1/2 x 0.75... 2.5 mm² Stripping length 9 mm Tightening torque 0.8... 1.2 Nm Recommended screw driver M3.5 (Pozidriv 2) 6-2CDC106061D0201

General data Duty time 100 % Operating frequency without early tripping Dimensions (W x H x D) Weight up to 15 operations/h or 60 operations/h with 40 % duty ratio, if the motor breaking current 6 x I n and the motor starting time does not exceed 1 s see dimension drawing see ordering data Mounting mount on the contactor and tighten the screws of the main circuit terminals Mounting position optional, position 1-5 Minimum distance to other units same type horizontal 5 cm vertical not applicable Minimum distance to electrical conductive board horizontal none vertical none Degree of protection housing IP20 main circuit terminals IP10 Maximum operating altitude 2000 m Environmental data Ambient air temperature Operation - compensated -25... +55 C -25... +55 C Storage -40... +70 C Ambient air temperature compensation acc. to IEC/EN 60947-4-1 Vibration (sinusoidal) acc. to IEC/EN 60068-2-6 (Fc) 1g / 3... 150 Hz Shock (half-sine) acc. to IEC/EN 60068-2-27 (Ea) 12g / 11 ms Standards / directives Standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC 2CDC106061D0201-7

Technical data UL/CSA Full load amps and short-circuit protective devices Type Full load amps Short-circuit protective device (FLA) 480 / 600 V AC 480 / 600 V AC 480 / 600 V AC Short circuit rating RMS symmetrical Fuse type Short circuit rating RMS symmetrical Fuse type Short circuit rating RMS symmetrical TF140DU-90 90 A 10 ka 250 A, K5 / RK5 100 ka 250 A, Class J 100 ka 250 A TF140DU-110 110 A 10 ka 250 A, K5 / RK5 100 ka 250 A, Class J 100 ka 250 A TF140DU-135 135 A 10 ka 250 A, K5 / RK5 100 ka 250 A, Class J 100 ka 250 A TF140DU-142 142 A 10 ka 250 A, K5 / RK5 100 ka 250 A, Class J 100 ka 250 A Listed circuit breaker Main circuit Maximum operational voltage Trip rating Full load amps (FLA) Short-circuit rating RMS symmetrical Short-circuit protective devices 600 V AC 125 % of FLA see table above see table above see table above Electrical connection Connecting capacity stranded 1/2 x AWG 6-2/0 flexible without ferrule 1/2 x AWG 6-2/0 Stripping length Tightening torque Recommended screw driver 25 mm 77... 88 Ib.in M8 (Hexagon) Auxiliary circuit Conventional thermal current NC / NO 10 A / 6 A Making and breaking capacity NC / NO B600 / C300 Electrical connection Connecting capacity stranded 1/2 x AWG 18-14 flexible without ferrule 1/2 x AWG 18-14 Stripping length 9 mm Tightening torque 12 Ib.in Recommended screw driver M3.5 (Pozidriv 2) 8-2CDC106061D0201

Contact us ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Brochure number 2CDC 106 061 D0201 (12.2014) Copyright 2014 ABB All rights reserved