Engine Generator Circuit Breakers

Similar documents
2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Switchboards Instant Service

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Cutler-Hammer. January 2001

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Pow-R-Flex low ampere busway

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Cutler-Hammer. January 2001

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

2.3. Molded Case Circuit Breakers. Contents

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Molded Case Circuit Breakers

Product Line Overview. The Most Logically Designed Contact Assembly

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Product Specification Sheet #3LD2.1

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Multi-Pak Group Control

25.5. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Application guide. Tmax Link OEM UL 891 Switchboard Program

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

Medium Voltage Metal-Enclosed Switches

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

5.2. Power Pedestals. Contents Description

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

6.2. Power Pedestals. Contents

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Dry-Type Transformers Mini-Power Centers

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Molded Case Circuit Breakers

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

3. Coils shall be of molded construction

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Molded Case Circuit Breakers Reference Guide

Medium Voltage Metal-Enclosed Switches

Quik-Spec Electrical Gear

Effective December 2015 Supersedes September 2013

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Molded Case Circuit Breakers

Air Conditioning Disconnects Molded Case Switch

PANELBOARDS C1/C2 SECTION 6

Bussmann series Quik-Spec Coordination Panelboard

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Enclosures. See Section Typical Description

SECTION PANELBOARDS

Molded Case Circuit Breakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Lighting and Power Distribution Panelboards

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

4.1. Definite Purpose Contactors and Starters. Contents

Molded Case Circuit Breakers

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Molded Case Circuit Breakers

Modular Metering. Canadian Version

Compact Circuit Protector (CCP)

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Molded Case Circuit Breakers

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Bulletin 1489 Circuit Breakers. Selection Guide

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters

EOEM panelboard and switchboard (OPS) Program

Transcription:

Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications...................................... 2 Technical Data and Specifications.................................. 2 Catalog Number Selection........................................ 3 Product Selection............................................... 4 Accessories................................................... 6 Breaker Dimensions............................................. 9 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 1

Engine Generator Circuit Breakers Product Description Eaton s engine generator molded case circuit breakers are designed specifically for application on diesel engine powered standby generators where high interrupting circuit breakers are not required. The JG through NG breakers are equipped with a special trip unit, that includes standard thermal (overload) protection and special low magnetic pickup range (FG includes a fixed thermalmagnetic pickup). The standard thermal trip unit provides overload protection for conductors per the National Electrical Code. The low magnetic pickup range is approximately two to five times the continuous rating and provides closer low-level short-circuit protection when applied on generators that have very low short-circuit capacity. This combination allows the user to customize the breaker to the generator output. Application Description Engine generator circuit breakers are suitable for reverse feed application. Standards and Certifications Engine generator molded case circuit breakers are designed to conform with the following standards: Underwriters Laboratories Standard UL 489, Molded Case Circuit Breakers and Circuit Breaker Enclosures File E7819 Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch Circuit Breakers International Electrotechnical Commission Recommendations IEC 947-2, Circuit Breakers Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application. Technical Data and Specifications UL 489 Interrupting Capacity Ratings Volts AC (50/60 Hz) 240 18,000 480 14,000 600 10,000 Interrupting Capacity (Symmetrical Amperes) IEC 947-2 Interrupting Capacity Ratings Volts AC (50/60 Hz) Interrupting Capacity (Symmetrical Amperes) I cu /I cs 220, 240 18,000/ 9,000 380, 415 14,000/ 7,000 660, 690 18,000/ 9,000 14,000/ 7,000 10,000/5,000 2 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com

Catalog Number Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers. FG breakers include both line and load side terminals JG, KG, LG and NG breakers with W catalog number suffix do not include any terminals JG, KG, LG and NG breakers without W catalog number suffix include both line and load terminals Contact Eaton for additional ratings and internal/external accessories Accessories shown for F-Frame have a quick ship availability Circuit Breakers FG, JG, KG, LG and NG FG 3 100 W A06 Frame FG Number of Poles 3 = Three-pole Trip Amperes 015 020 025 030 035 040 045 050 060 070 080 090 100 125 150 175 200 225 Suffix W = Without terminals Blank = Terminals included Accessory A06 = 1A 1B A13 = 2A 2B B06 = 1 Mk 1 Brk C05 = 1A 1B/Mk Brk S02 = 12 24 Vac S06 = 48 127 Vac S18 = 12 24 Vac S22 = 48 127 Vac N02 = 24 Vdc U14 = 110 127 Vdc JG 175 200 225 250 KG 300 350 400 LG 450 500 600 NG 700 800 900 1000 1200 Accessories shown are for common F-Frame only; other configurations are available. See catalog for other frame sizes. Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 3

Product Selection The following table lists FG through NG engine generator breakers with the maximum generator kva and kw rating. Engine generator breakers are applied at 115% of the generator full load current rating (FLA). The maximum kw rating is based on threephase generators at 80% power factor. Breakers shown below include line and load terminals. Thermal-Magnetic Magnetic Pickup Range Maximum Generator Rating 60 Hz Notes Breaker continuous current is based on 115% of the generator full load ampere rating. Based on three-phase generators at 80% power factor. FG, JG, KG include thermal-magnetic trip units; LG and NG include electronic trip units. The following catalog numbers have center tap studs for dual voltage applications: JG3070CT, JG3100CT, JG3125CT, KG3175CT, LG3300CTW. Engine Generator Breaker 240 Vac 480 Vac 600 Vac Catalog kva kw kva kw kva kw Number Fixed 5 4 11 9 14 11 FG3015 Fixed 7 6 14 12 18 14 FG3020 Fixed 9 7 18 14 23 18 FG3025 Fixed 11 9 22 17 27 22 FG3030 Fixed 13 10 25 20 32 25 FG3035 Fixed 14 12 29 23 36 29 FG3040 Fixed 16 13 32 26 41 32 FG3045 Fixed 18 14 36 29 45 36 FG3050 Fixed 22 17 43 35 54 43 FG3060 Fixed 25 20 51 40 63 51 FG3070 Fixed 29 23 58 46 72 58 FG3080 Fixed 32 26 65 52 81 65 FG3090 Fixed 36 29 72 58 90 72 FG3100 Fixed 40 32 79 64 99 79 FG3110 Fixed 45 36 90 72 113 90 FG3125 Fixed 54 43 108 87 135 108 FG3150 Fixed 63 51 126 101 158 126 FG3175 Fixed 72 58 144 116 181 144 FG3200 Fixed 81 65 162 130 203 162 FG3225 350 700 63 51 126 101 158 126 JG3175 350 700 72 58 144 116 181 144 JG3200 350 700 81 65 162 130 203 162 JG3225 350 700 90 72 181 144 226 181 JG3250 500 1000 108 87 217 173 271 217 KG3300 500 1000 126 101 253 202 316 253 KG3350 1000 2000 144 116 289 231 361 289 KG3400 4 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com

Electronic Magnetic Pickup Range Maximum Generator Rating 60 Hz Engine Generator Breaker 240 Vac 480 Vac 600 Vac Catalog kva kw kva kw kva kw Number 500 2500 162 130 325 260 406 325 LG3450 500 2500 181 144 361 289 451 361 LG3500 500 2500 217 173 433 347 542 433 LG3600 500 2500 253 202 505 404 632 505 NG3700 500 2500 289 231 578 462 722 578 NG3800 1250 5000 325 260 650 520 812 650 NG3900 1250 5000 361 289 722 578 903 722 NG31000 1250 5000 433 347 867 693 1083 867 NG31200 Notes Breaker continuous current is based on 115% of the generator full load ampere rating. Based on three-phase generators at 80% power factor. FG, JG, KG include thermal-magnetic trip units; LG and NG include electronic trip units. Breaker includes line and load terminals. The following catalog numbers have center tap studs for dual voltage applications: JG3070CT, JG3100CT, JG3125CT, KG3175CT, LG3300CTW. Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 5

Accessories Selection Guide and Ordering Information Enclosures Type 1 General Purpose Surface or flush mounting 15 1200 ampere range 600 Vac, 500 Vdc Type 1 enclosed breakers are designed for use in commercial buildings, apartment buildings and other areas where a general purpose enclosure is applicable. The breaker is front operable and is capable of being padlocked in either the ON or OFF position. Ratings through 1200 amperes are listed with Underwriters Laboratories as approved for service entrance application. Both surface and flush mounted enclosures are available. Type 12 Dustproof Surface Mounting No knockouts or other openings 15 1200 ampere range 600 Vac, 500 Vdc The Type 12 enclosure is designed in line with specifications for special industry applications where unusually severe conditions involving oil, coolant, dust and other foreign materials exist in the operating atmosphere. The handle padlocks in the OFF position and the cover is interlocked with the handle mechanism to prevent opening the cover with the circuit breaker in the ON position. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application. Type 3R Rainproof Surface Mounting Interchangeable hubs (through 400 amperes) 15 1200 ampere range 600 Vac, 500 Vdc This general purpose outdoor service center employs a circuit breaker inside a weatherproof sheet steel breaker enclosure to serve as a main disconnect and protective device for feeder circuits. Ratings through 1200 amperes are listed by Underwriters Laboratories as suitable for service entrance application. Enclosure Selection Data Breaker Frame Amperes FG 15 225 JG 175 250 KG 300 400 LG 450 600 NG 700 1200 Enclosure Type Class A B C D E Approx. Weight Lbs (kg) Conduit Sizes, Inches Catalog Number Type 1 23.25 (590.6) 8.41 (213.6) 6.28 (159.5) 18.75 (476.3) 1.20 (30.5) 15 (7) 0.25, 0.50, 0.75, 1, 1.25, 1.50, 2, 2.50 SFDN225 Type 3R 25.66 (651.8) 8.84 (224.7) 9.31 (236.5) 24.28 (616.7) 1.70 (43.2) 19 (9) 0.25, 0.50, 0.75, 1, 1.25, 1.50, 2, 2.50 RFDN225 Type 12 25.66 (651.8) 8.84 (224.7) 9.31 (236.5) 24.28 (616.7) 1.70 (43.2) 18 (8) JFDN225 Type 1 34.70 (881.4) 10.92 (277.4) 7.20 (182.9) 30.00 (762.0) 1.88 (47.8) 31 (14) 0.25, 0.50, 2, 2.50, 3 SJDN250 Type 3R 37.50 (952.5) 11.56 (293.6) 10.22 (259.6) 35.77 (908.6) 1.94 (49.3) 40 (18) 0.25, 0.50, 2, 2.50, 3 RJDN250 Type 12 37.53 (953.3) 11.56 (293.6) 10.22 (259.6) 35.77 (908.6) 1.94 (49.3) 37 (17) JJDN250 Type 1 38.81 (985.8) 11.06 (280.9) 10.94 (277.9) 34.00 (863.6) 2.28 (57.9) 53 (24) 0.25, 0.50, 0.75, 1.50, 2, 2.50, 3, 3.50 SKDN400 Type 3R 41.69 (1058.9) 11.75 (298.5) 14.06 (357.1) 39.90 (1013.5) 1.97 (50.0) 60 (27) 0.25, 0.50, 0.75, 2.50, 3, 3.50 RKDN400 Type 12 41.69 (1058.9) 11.75 (298.5) 14.06 (357.1) 39.90 (1013.5) 1.97 (50.0) 53 (24) JKDN400 Type 1 45.88 (1165.4) 14.31 (363.5) 12.38 (314.5) 46.56 (1182.6) 1.91 (48.5) 81 (37) 0.25, 0.50, 0.75, 3, 3.50, 4 SLDN600 Type 3R 48.31 (1227.1) 14.91 (378.7) 15.50 (393.7) 46.56 (1182.6) 1.92 (48.8) 84 (38) 0.25, 0.50, 0.75, 3, 3.50, 4 RLDN600 Type 12 48.31 (1227.1) 14.91 (378.7) 15.50 (393.7) 46.56 (1182.6) 1.92 (48.8) 81 (37) JLDN600 Type 1 61.22 (1555.0) 21.44 (544.6) 15.41 (391.4) 61.84 (1570.7) 1.97 (50.0) 178 (81) SNDN1200 Type 3R 63.59 (1615.2) 22.00 (558.8) 17.63 (447.8) 61.84 (1570.7) 1.97 (50.0) 175 (79) RNDN1200 Type 12 63.59 (1615.2) 22.00 (558.8) 17.63 (447.8) 61.84 (1570.7) 1.97 (50.0) 170 (77) JNDN1200 6 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com

Type 1 Surface Mounted Type 3R Rainproof Type 12, 12K Dustproof E B C E C E C D A A D ON OFF A D ON OFF B B Enclosures, continued Neutral Kits, Insulated and Groundable Max. Enclosure Rating (Amperes) Main Lug Number Size Cu/Al Ground Lug Size Cu/Al Catalog Number 100 (1) 14 1/0 (1) 14 1/0 INK100 250 (1) 6 350 kcmil (1) 4 300 kcmil INK250 400 (1) 4 750 kcmil or (2) 1/0 250 kcmil (1) 4 300 kcmil INK400 600 (2) 250 500 kcmil (1) 4 300 kcmil INK600 1200 (3) 1/0 to 750 kcmil or (4) 1/0 to 750 kcmil (1) 6 250 kcmil INK1200 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 7

Options and Accessories Internal Accessories Standard Terminals Breaker Frame Max. Amp Rating Optional Terminals AWG Wire Range Metric Wire Range mm 2 Catalog Number FG 100 14 1/0 2.5 50 3T100FB FG 150 4 4/0 25 95 3TA225FD JG 250 4 350 kcmil 25 185 TA250KB KG 350 250 500 kcmil 120 240 TA350K KG 400 3/0 250 kcmil (2) 95 120 3TA400K LG 600 250 500 kcmil (2) 120 240 3TA603LDK NG 700 1 500 kcmil (2) 50 300 TA700NB1 NG 1000 3/0 400 kcmil (3) 95 185 TA1000NB1 NG 1200 4/0 500 kcmil (4) 120 300 TA1200NB1 Breaker Frame Max. Amp Rating AWG Wire Range Z Suffix (Line and Load Terminals) Catalog Number FD, FG 100 14 1/0 LZ04 3T100FB 225 4 4/0 LZ05 3TA225FD JD, JG 250 4 350 kcmil N/A TA250KB KD, KG 225 (1) 3 350 kcmil Z01 TA300K 350 (1) 250 500 kcmil Z02 TA350K 400 (2) 3/0 250 kcmil Z04 3TA400K LD, LG 400 (1) 4/0 600 kcmil Z12 3TA401LDK 450 (2) 4 4/0 Z22 TA450LD 500 (2) 3/0 350 Z01 TA602LD 600 (2) 400 500 kcmil Z04 3TA603LDK ND, NG 700 (2) 1 500 kcmil Z01 TA700NB1 1000 (3) 3/0 400 kcmil Z02 TA1000NB1 1200 (4) 4/0 500 kcmil Z04 TA1200NB1 1200 (3) 500 750 kcmil Z03 TA1201NB1 Auxiliary Switch Breaker Frame Shunt Trip Factory Mounted 1A-1B Field Kit Catalog Number Factory Mounted Notes Package of three terminals. Other accessories are available. Same as standard frame breakers. Field installation on the FG Frame is not UL listed. 2A-2B Field Kit Catalog Number FG A06 A1X1PK A13 A2X1RPK JG A06 A1X2PK A13 A2X2PK KG A06 A1X3PK A13 A2X3PK LG A06 A1X4PK A13 A2X4PK NG A06 A1X5PK A13 A2X5PK Breaker Frame Rating Factory Mounted Field Kit Catalog Number FG 12 24 Vdc S02 SNT1LP03K JG 12 24 Vdc S42 SNT2P04K KG 12 24 Vdc S42 SNT3P04K LG 12 24 Vdc S02 SNT4LP03K NG 12 24 Vdc S02 SNT5LP03K 8 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com

Breaker Dimensions FG-Frame, Three-Pole Front View Side View On Off 6.00 (152.4) 4.13 (104.9) 3.38 (85.7) JG-Frame, Three-Pole 0.34 R (8.7 R) Front View Cutout 1.56 (39.7) 0.78 (19.8) Front View 4.13 (104.8) Side View 3.94 (100.0) 0.72 (18.2) 0.50 (12.7) Diameter 3 Megger Holes if Required 0.19 R (4.8) R C L Handle C L Breaker 2.75 (69.9) 3.50 (88.9) 2.92 (74.2) 0.88 (22.2) 3.33 (84.5) 1.38 (34.9) 1.75 (44.5) 10.00 (254.0) ON OFF 4.06 (103.2) Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 9

KG-Frame, Two- and Three-Pole Front Cover Cutout Front View 5.49 (139.4) Side View 4.31 (109.6) 0.34 R (8.7 R) C L Handle 0.83 (21.0) 3.75 (95.3) 1.64 (41.7) 0.19 R (4.8 R) 2.63 (66.7) 2.39 (60.7) 4.78 (121.5) 1.31 (33.3) 1.25 (31.8) ON OFF 10.13 (257.2) LG-Frame, Two- and Three-Pole 1.72 (43.7) C L Handle Front Cover Cutout 3.44 (87.3) C L Breaker 0.25 (6.4) R 1.33 2.29 (33.7) (58.2) 3.28 (83.3) Front View 10.75 (273.1) Side View 3.81 (96.8) 8.21 (208.6) 3.64 0.19 R (92.5) 1.50 (4.8) R 7.28 (38.1) (184.9) 8.25 (209.6) NG-Frame, Two- and Three-Pole Front Cover Cutout Front View Side View 3.44 (87.3) 3.68 (93.2) 1.72 (43.6) 1.91 (48.4) C L Handle 0.25 R (6.4 R) CLHandle 0.19 R (4.8 R) 16.00 (406.4) ON/I OFF/O 1.50 (38.1) 3.19 (80.9) 6.38 (161.9) 8.25 (209.6) 5.50 (139.7) 10 Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com

Engine Generator Circuit Breakers CA01214001E June 2011 www.eaton.com 11

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customerdriven PowerChain solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved Printed in USA Publication No. CA01214001E / Z10660 June 2011 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.