Elimsan High Voltage Disconnectors

Similar documents
Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

NRB Disconnector for outdoor installation

Disconnectors and earthing switches up to 25 kv AC

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

RAPIER DSB Disconnectors

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

SF6 Gas-Insulated Metal Enclosed Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

045 : 2000 CEB STANDARD

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

DBM Range 1500VDC (13,5kA to 20kA)

B kv Gas-insulated Substations

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Publication No.: PSG

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

Gas Insulated Switchgear

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2


Single-Column Pantograph Disconnectors for Outdoor Installation Type TFB three poles installation

Disconnectors FA range 750VDC 250 to 2000Amp

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Disconnectors FA range 1500VDC 250 to 2000Amp

Independent Testing Laboratory for High Voltage Equipment

Section 2 - Substation Switchgear

Vacuum Circuit Breaker

SWITCHGEAR. 4G cam switches

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

Transmission Switching

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

AIR CORE REACTORS. Phoenix Electric Corporation

Vacuum Circuit Breaker

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

132/11 kv, 25 MVA MOBILE SUBSTATION

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Disconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device

E-12 Low-voltage Switchboard

ONIII. Outdoor disconnector DTR EN

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

1. Safety practices General Introduction Standards...3

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

PIX-H Metal-clad switchgear up to 17.5kV

SUSPENSION 04 CLAMPS

Vistop TM isolating switches 63 to 160A

High Power Switchgear. We can create a solution that s both effective and cost-effective

Outdoor vacuum breaker for railway applications - FSK II

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

MESG 12 / 17.5 / 24 / 36 KV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Extensible Unit - VCE2a

HMI, APRIL, Test Laboratories in Ratingen

IEC Low Voltage General Purpose Protection

B kv T&D GAS INSULATED SWITCHGEAR

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SF 6 Gas Insulated Load Break Switch

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

INDEX Bustrunking System Standard & Specifications Technical Parameters Copper Aluminum Components

INTER PLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR AC CABIN FAN. Corresponding IS does not exist IPSS:

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

TECHNICAL SPECIFICATIONS

High Voltage Disconnect Switches

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NXPLUS C Single busbar. Maintenance-free for lifetime

Benefits, typical uses

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Transformer bushings, type GOH. Technical guide

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Euroload Changeover Switch

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Size and Configurations

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Transcription:

Elimsan High Voltage Disconnectors Pantograph Type Center-Break Type Double-Break Type Vertical-Break Type Standards IEC 62271-102 IEC 62271-1 Nature is our most distinguished partner YG-EN-12-01

Elimsan High Voltage Disconnectors

General information All Elimsan high voltage disconnectors have common properties as given below; Type test of the Elimsan High Voltage disconnectors are carried out in well known international laboratories such as CESI-Italy and KEMA-Holland. Application Regulations Test Earthing Switches Disconnector and earthing switch machanism Auxiliary switch Installation Maintenance Application Disconnectors ensure mechanical isolation of electrical systems. When a disconnector is open, visible isoloted space is obtained. Elimsan High Voltage disconnectors can be easily applied to all types of substations. If desired, disconnector poles can be equipped with an earthing system. Regulations The disconnectors are manufactured in compliance with IEC 62271-102, IEC 60694 standards. Test Type test of the Elimsan High Voltage disconnectors are carried out in well known international laboratories such as CESI-Italy and KEMA-Holland. All required electrical and mechanical routine test are also carried out, during manufacturing of disconnectors Earthing switches Earthing blade moves by rotating about 90 degrees.while disconnectors are closed, earthing blade is in the parallel position to the ground. Earthing blade is wanted to close, operating mechanism can be operated by hand or a motor.earthing blade rotates around the pivot until it settles into the fix contacts through the transmission from the mechanism. After earthing blade settles into the fix contacts, earthing blade can not be opened due to the any external factors in this position. It means safe earthing is ensured Disconnector and earthing switch machanism Depends on the requirements disconnector and earthing switch mechanism can be motor controlled or manual. There is an electrical interlocking between disconnector and earthing mechanism in motor controlled system. Before the disconnector is opened, earthing switch can not be operated. The system is also mechanically locked. In manual operation unless disconnector is open, earthing switch can not be closed. Auxiliary switch Auxiliary switch receives motion from the operating mechanism. This switch unit does not change position until the arms of the disconnectors are not changed. Installation Elimsan High Voltage disconnectors are shipped in the form of pre assembled units, which have to be assembled at site. Disconnectors are designed in order to be easily installed and adjusted at site. Maintenance Normally, Elimsan High Voltage disconnectors do not require maintenance. It is sufficient to clean only the insulators once every four or five years. 3

High Voltage Pantograph Type Disconnector Leak-proof mechanism High safety Easy operating system

Pantograph type Design and drive High safety and mechanical rigidity, even in the short circuit Elimsan pantograph type disconnectors (EDP) are designed in double scissors form and it contains operating mechanism, mechanism of current arms, insulator, earthing switches (if needed). Current arms are manufactured from aluminum alloy profiles, designed to ensure high safety and mechanical rigidity, even in the short circuit. The connection terminals are placed at both sides of mechanism of current arms. Pantograph arms are permanently lubricated for miantenance free operation. The operation mechanism is placed on the chassis and drives the mechanism of the current arms through a rotating insulator. The operation mechanism is leak-proof and made of noncorrosive material and can be manufactured up to IP65 protection level. Each pole of the pantograph type disconnector is operated with an individual operation mechanism for disconnectors over 170. The motion from the operating mechanism istransmitted by operating insulator to the Disconnector type EDP-145 EDP-170 EDP-245 EDP-362 EDP-420 EDP-525 A- Distance between ins ulator and fixed contact mm 2600 2920 3450 5075 5075 5675 B- Height of disconnector arm (in closed position) mm 2400 3110 3700 5450 5450 6050 C- Height of insulator mm 1500 1700 2300 2900 3350 4400 D- Width of disconnector mechanism mm 435 550 E- Width of disconnector arm mm 500 597 610 F- Distance from top of mechanism to insulator mm Customer requirements G- Height of ground to top of mechanism mm Customer requirements H- Minimum isolating distance mm 1500 2100 2540 3500 3500 4150 J- Lenght of disconnector arm (in open position) mm 2500 2060 2500 2210 2210 K- Catching range mm mm 300 300 450 500 550 L mm 50 M mm 50 Main dimension of EDP disconnector 5

Pantograph type mechanism of current arms and from there it sent to the pantograph arms. Up to 170, three phases pantograph disconnectors can be controled by one operating mechanism. Safety and durability The arms rise and catch hanger type fixed terminal securely. In this position current arms have to apply enough pressure on contacts for transmitting current properly but this pressure shouldn t cause erosion and deformation on contacts. Mechanism of current arm ensures lock according to dead point position and only the operation mechanism can change this position. The movement of current arms are prevented from the effect of external forces. The disconnector can not be opened even in severe conditions of nature such as strong winds, earthquake, etc. Ice-layers that form because of the bad weather conditions can be broken easily by opening and closing forces of current arms opening and closing operations can be performed. Connection Hanger type fix terminals are connected to the bar by flexible conductors. The connection terminals are placed at both sides of mechanism of current arms for the second system. The fix contacts of 145, 170, and 245 pantograph type disconnectors are connected with single conductor and fix contacts of 362, 420 and 550 disconnectors are connected with double flexible conductor EDP with earthing switches EDP without earthing switches A B E 6

Pantograph type Pantograph type disconnecton EDP-145 EDP-170 EDP-245 EDP-362 EDP-420 EDP-525 Rated voltage 145 170 245 362 420 525 Rated normal current A Rated peak withstand current ka 100 100 100 125 125 125 Rated short time withstand current (1s.) ka (rms) 40 40 40 50 50 50 Rated 1 min power freguency withstand voltage (50 Hz) Rated lighting impulse To earth and between poles (rms) 275 325 460 450 520 620 Across the isolating distance (rms) 315 375 530 520 610 760 To earth and between poles 650 750 1050 1175 1425 1550 Withstand voltage (1,2/50 µs) Across the isolating distance 750 860 1200 1175 (+205) 1425 (+240) 1550 (+315) Rated switching impulse withstand Voltage (250/2500 µs) To earth and between poles ka 950 1050 1175 Across the isolating distance class ka 950 1050 1175 Across the isolating dist. class B ka 800 (+295) 900 (+345) 900 (+450) Discharge inception voltage >95 >110 >160 >230 >270 >335 Three-phase breaking capacity Admissible mechanical Terminal load Overall height of support insulator Inductive, capacitive A 2 2 1.5 1 1 1 Resistive A 3 3 3 2 2 2 Static and dynamic'5fc N 5600 5600 5600 5600 Static N 1000 1000 2000 2000 2000 2000 mm 1500 1700 2300 2900 3350 4400 On earthing switch +E +E +E +E +E +E EDP technical list 7

High Voltage Center Break Type Disconnector Robust steel structure Adjustable arms Easy operating system 8

Center break type to have maintenance free disconnectors. The steel components are hot-dip galvanized to protect disconnectors from atmospherical effects. Design and drive Strong and functional structure The center-break type disconnector (EDC) s chassis are made of steel. Support insulators are on top of rotating feet on the chassis. The support insulators carry aluminum current arms. Axis deviations can be easily corrected by adjusting bolts on the rotating feet. If required, disconnector can be equipped with an earthing unit. The earthing unit has an indivual operating mechanism. All parts are designed Separate control systems The disconnector and earthing units are operated with separate control systems. The motion transmitted to the rotating feet from the operating mechanism, is immediately transferred to the other phases by the cross levers and ensures simultaneous drive of all three phases. Current arms are rotated 90 degree and become parallel each others when EDC is open. Depends on the requirements, disconnectors can be delivered manual or motor controlled. All of three disconnectors phases are activated by only one operating Disconnector type EDC-36 EDC-52 EDC-72 EDC-123 EDC-145 EDC-170 EDC-245 EDC-362 EDC-420 EDC-525 A mm 720 720 1250 1520 2000 2300 2750 3800 4100 4100 B mm 620 620 1000 1300 1700 2050 2500 3500 3500 3500 C mm 759 900 1150 1675 2000 2150 2670 3270 4300 4300 D mm 350 350 550 750 900 1075 1300 1800 2250 2250 E mm 1000 1250 1500 2000 2600 3000 Customer requirements F mm 1300 1500 2000 2600 3400 5200 Customer requirements G mm 500 690 1080 1380 1800 1820 2400 2715 3715 3715 Main dimension of EDC disconnector 9

Center break type mechanism (up to 245 ) and earthing unit is activated by another separated operating mechanism. Adjustment is possible with the motion pipes placed between the phases. There is a mechanical and electrical interlocking facility between disconnector and earthing units. Thus the earthing blade cannot be closed when the disconnector is in closed position. Ice-layers formed because of the bad weather conditions can be broken easily by opening and closing forces of current arms thus opening and closing operation are performed Connection Disconnectors are connected to the system through the terminals. These terminals are cylindrical, and they are made of electrolytic copper with silver coating these terminals rotate also on their axis. These terminals diameters and lengths are variable depends on the disconnectors voltage and current ratings. There is one / two earthing bolt on the chassis for earthing connections Parallel installation Serial installation 10

Center break type Centre break type disconnector EDC-36 EDC-52 EDC-72 EDC-123 EDC-145 EDC-170 EDC-245 EDC-362 EDC-420 EDC-525 Rated voltage 36 52 72.5 123 145 170 245 362 420 525 Rated normal current A 800-1600 2500 2500 2500 Rated peak withstand current ka 80 80 80 100 100 80 100 125 125 125 Rated short time current (1s.) ka (rms) 31.5 31.5 31.5 40 40 31.5 40 50 50 50 Rated 1 min power freguency To earth and between poles (rms) 70 95 140 230 275 325 460 450 520 620 Withstand voltage (50 Hz) Across the isolating distance (rms) 80 110 160 265 315 375 530 520 610 760 Rated lighting impulse To earth and between poles 170 250 325 550 650 750 1050 1175 1425 1550 Withstand voltage (1,2/50 ms) Across the isolating distance 195 290 375 630 750 860 1200 1175 (+205) 1425 (+240) 1550 (+315) Rated switching impulse withstand Voltage (250/2500 ms) To earth and between poles Across the isolating distance class A Across the isolating distance class B 950 1050 1175 950 1050 1175 800 900 900 (+295) (+345) (+450) Discharge inception (rms) >22 >34 >48 >80 >95 >110 >160 >230 >270 >335 Three-phase breaking capacity Inductive, capacitive A 2 2 2 2 2 2 1.5 1 1 1 Resistive A 3 3 3 3 3 3 3 2 2 2 Admissible mechanical Static and dynamic N 5600 5600 5600 5600 Terminal load Overall height of support insulator Static N 1000 1000 1000 1000 1000 1000 2000 2000 2000 2000 mm 445 560 770 1220 1500 1700 2300 2900 3350 4400 On earthing switch +E +E +E +E +E +E +E +E +E +E EDP technical list 11

High Voltage Double Break Type Disconnectors High mechanical rigidity Electrical and mechanical interlocking Support insulators

Double break type If required, disconnector can be equipped with earthing units. The earthing unit has an individual operating mechanism. All parts have been permanently lubricated and designed to have maintenance free operation. Design and drive Robust structure The Double side break type (EDB) disconnectors chassis are made of steel. Rotating feet on the chassis carries moving insulators, each phase comprise 2 fixed insulator connected to chasis at both side and one rotating insulator connected to rotating feet in the middle. Rotating insulators carry current arms. Current arms are manufactured from aluminum alloy profiles for 123 disconnectors and over, up to 123 from electrolitic copper. Axis deviation on the insulators can be easily adjusted by the bolts on the rotating feet. The steel components are hot-dip galvanized to protect from atmospherical effects. The connection terminals are placed on the insulators at both sides. High mechanical rigidity Double break type system ensures high mechanical rigidity and safe current transmission in short circuit. It requires less distance between the phases. The disconnector can be delivered as manual or motor controlled. Easy control Three poles of disconnector and earthing unit could be activated by only one operating mechanism (up to 245 ). Adjustment is possible through the connection levers placed in between the Disconnector type EDB-12 EDB-36 EDB-52 EDB-72 EDB-123 EDB-145 EDB-170 EDB-245 EDB-420 Figure 1 1 1 1 2 2 2 2 2 A mm 740 1150 1170 1240 1800 2200 2500 3300 5200 B mm 215 440 560 770 1220 1500 1700 2300 3650 C mm 360 585 850 950 1700 1900 2100 2700 4400 D mm 700 800 950 1100 1700 2000 2300 3300 E mm 320 550 820 900 1600 1800 2000 2600 4300 F mm 840 1250 1400 1500 1550 2500 2800 3600 5800 G mm Customer requirements H mm Customer requirements Main dimension of EDB disconnector 13

Double break type poles. There is a mechanical and electrical interlocking facility between the disconnector and earthing units thus, earthing contacts can not be closed when the disconnector is in closed position. Disconnector and earthing unit are operated with an individual operation mechanism. The motion transmitted from the operation mechanism trough the rotating insulator is immediately transferred to the other phases by the cross levers and ensures simultaneous drive of all three phases. Each phase is operated by an individual mechanism over 245 disconnectors. Special locking system Current arms rotate through rotating insulator that is in the middle of each phase. Because of the lengths of motion transmission pipes between the phases are adjustable, to ensure simultaneous motion for each phase, the positions can be adjusted accurately. Unnecessary motions are restricted by mechanical stoppers. Mechanism system ensures electromechanical lock in open and closed position. This interlock prevents motions may be caused by external factors such as short circuit forces, winds, and earthquake. Ice-layers that form because of the bad weather conditions can be broken easily by opening and closing forces of current arms thus opening and closing operation are performed. Connection The main circuit connections are placed on the insulators and both sides. It is suitable for fixing any kind ofconnection means EDB 72 and belove EDB 123 and above 14

Double break type Double break type disconnector EDB-12 EDB-36 EDB-52 EDB-72 EDB-123 EDB-145 EDB-170 EDB-245 EDB-420 Rated voltage 12 36 52 72 123 145 170 245 420 Rated normal current A Rated peak withstand current ka 80 80 80 80 100 100 100 100 125 Rated short time current (1s.) Rated 1 min power freguency withstand voltage (50 Hz) To earth and between phases Across the isolating distance ka (rms) 31,5 31,5 31,5 31,5 40 40 40 40 50 (rms) 28 70 95 140 230 275 325 460 520 (rms) 32 80 110 160 265 315 375 530 610 Rated lighting impulse withstand voltage (1,2/50 ms) To earth and between phases Across the isolating distance 75 170 250 325 550 650 750 1050 1425 85 195 290 375 630 750 860 1200 1425 (+240) Rated switching impulse withstand To earth and between phases 1050 voltage (250/2500 ms) Across the isolating distance 900 (+345) Three-phase breaking capacitive, enductive A 2 2 2 2 2 2 2 1.5 1 resistive A 3 3 3 3 3 3 3 3 2 Static mechanical N 400 400 400 400 500 500 800 1000 2000 terminal loads N 130 130 130 130 170 170 250 330 660 On earthing switch +E +E +E +E +E +E +E +E +E EDP technical list 15

High Voltage Vertical Break Type Type Disconnectors Multi functional design Seperate operating mechanism Strong structure

Vertical break type fix contacts are manufactured from electrolytic copper). If required, disconnector can be equipped with an earthing unit. Design and drive Steel chasis The Vertical type disconnector (EDV) s chassis are made of steel. Rotating feet on the chassis carries operating insulators for the 72.5 disconnectors and over.( For the 52 rated voltage disconnectors and less, use operating rod and support insulators ) Each phase comprise 2 fix insulator connected to chasis at both side and one moving operating insulator connected to rotating feet at the end. Support insulators carry current arms and fixed contact. Protected against hard atmospherical effects Current arms are manufactured from aluminum alloy profiles (For 52 and less, current arms and The earthing unit has a separate operating mechanism. All parts have been permanently lubricated and designed to have maintenance free disconnectors. The steel components are hot-dip galvanized to protect from atmospherical effects. The connection terminals are placed at both sides of the support insulators. During the closing process, disconnector arm moves to down first and when reach to the contact level, it goes into contact through moving along its axis for the disconnectors over 72.5 ; thus ensure high safety and additional lock against external effects. Less distance between phases Vertical type breaking system require less distance between the phases. The operating mechanism is put inside a box that is made from aluminum alloy or stainles steel (Up to IP65). Disconnector type EDV-12 EDV-36 EDV-52 EDV-72 EDV-123 EDV-145 EDV-170 EDV-245 EDV-420 Figure 1 1 1 1 2 2 2 2 2 A mm 740 1150 1170 1240 1800 2200 2500 3300 5200 B mm 215 440 560 770 1220 1500 1700 2300 3650 C (in closed position) mm 360 585 850 950 1700 1900 2100 2700 4400 D mm 700 800 950 1100 1700 2000 2300 3300 E mm 320 550 820 900 1600 1800 2000 2600 4300 F mm 840 1250 1400 1500 1550 2500 2800 3600 5800 G mm Customer requirements H mm Customer requirements Main dimension of EDV disconnector 17

Vertical break type Adjustable control system The disconnector can be delivered as manual or motor controlled. Three poles of disconnector and earthing unit could be activated by only one driving mechanism (up to 170 ). Adjustment is possible through the connection levers placed in between the poles. There is a mechanical and electrical interlocking facility between the disconnector and earthing units thus, earthing contacts can not be closed when the disconnector is in closed position. High safety to external factors Disconnector and earthing unit are operated with an individual operating mechanism. The motion transmitted from the operating mechanism trough the operating insulator isimmediatelytransferred to the other phases by the cross levers and ensures simultaneous drive of all three phases.current arms rotate through operating insulator and rise to upward in open position. By the means of adjustable lengths of motion transmission pipes between the phases, 3 phases motion can be adjusted accurately. The stoppers restrict the motion at required position. Mechanism system ensures mechanical lock in open and closed position. This provides safe operation against external factors, such as short circuit forces, winds, and earthquake. Ice-layers that form because of the bad weather conditions can be broken easily by opening and closing forces of current arms thus opening and closing operation are executed. Connection The main circuit connections are placed on the post insulators at both sides. It is suitable for connecting bus bar with 4 bolts other type of connection means are possible. EDV 72 and over EDV 52 and less 18

Vertical break type Vertical break type disconnector EDV-12 EDV-36 EDV-52 EDV-72 EDV-123 EDV-145 EDV-170 EDV-245 EDV-420 Rated voltage 12 36 52 72 123 145 170 245 420 Rated normal current A Rated peak withstand current Rated short time current (1s.) Rated 1 min power freguency withstand voltage (50 Hz) Rated lighting impulse withstand voltage (1,2/50 ms) Rated switching impulse withstand voltage (250/2500 ms) To earth and between phases Across the isolating distance To earth and between phases Across the isolating distance To earth and between phases Across the isolating distance ka 80 80 80 80 100 100 100 100 125 ka (rms) 31,5 31,5 31,5 31,5 40 40 40 40 50 (rms) 28 70 95 140 230 275 325 460 520 (rms) 32 80 110 160 265 315 375 530 610 75 170 250 325 550 650 750 1050 1425 85 195 290 375 630 750 860 1200 1425 (+240) 1050 900 (+345) Three-phase breaking capacitive, enductive A 2 2 2 2 2 2 2 1.5 1 resistive A 3 3 3 3 3 3 3 3 2 Static mechanical N 400 400 400 400 500 500 800 1000 2000 terminal loads N 130 130 130 130 170 170 250 330 660 On earthing switch +E +E +E +E +E +E +E +E +E EDP technical list 19

Note : Elimsan s policy is continuous development and improvement. Therefore the right is reserved to supply products which may differ in detail from those described and illustrated in this publication. Elimsan Switchgear Equipment and Electromechanics Industry and Trade, Inc. IZMIT / TURKEY Tel : 90 262 375 23 60 Fax : 90 262 375 23 22 sales@elimsangroup.com www.elimsangroup.com