GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) HC- series. Classic

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

DCS- series. Classic

OFFLINE SERIES GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Compressor Aftercoolers GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

BYPASS SERIES GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

AKG 2009 (changes and errors expected) AKG 2010 (changes and errors expected) Water Cooled

When working with original equipment manufacturers, hydraulic system designers and plant maintenance engineers, one of the key factors for long

THERMAL SYSTEMS, INC.

Fluid Cooling Mobile AOHM / AOVHM Series

Off-line filter / cooler unit BKF

SERIES. Dirty Environment Oil Coolers ACD

Fluid Handling: Panel Unit

A global leader in manufacturing highly engineered heat transfer technologies

Fluid Cooling Industrial COLW Series

Off-Line Filter BNF. FluidControl

Cooling Systems CC Series TT rail 20/30lpm

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

Oil/air cooler BLK. Fluidcontrol

Circulation pumps BFP-ATEX-T3/T4

Low Pressure Filters

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Oil/air cooler BLK. Fluidcontrol

Off-line filter / cooler unit FGSL

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

Cooling Systems Air Cooled / Liquid Cooled

15/40/80CN Series. Medium Pressure Filters

Essentials encapsulated 3-20 HP

Fluid Power Conference and Expo

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

Sullair: An Industry Leader

Coolers. Air Cooled / Liquid Cooled

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

SPIN-ON FILTER - LOW PRESSURE LINE

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

OFFLINE FILTRATION SYSTEMS

Oil/air cooler BLK ATEX-3GD

15/40/80CN Series Coreless Medium Pressure Filters

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17

SPIN-ON FILTERS & ELEMENTS

LKI LKI-HYD COOLING. Series. advanced quality customized designs made in europe. Oil/Air heat exchangers. Low noise level. High performance.

HYDRAULIC MOTOR FAN DRIVEN PRODUCTS

Installation Instructions Precision Sport Shifter

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

High Speed Hydraulic Motors

D SERIES HYDRAULIC PUMP

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

LT Series Lubricant Management System (LT-LMS)

PRODUCT BROCHURE. Innovative Fluid Transfer, Filtration, and Tank Cleaning Systems

Fluid Power Fluid Power

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

EG Series Screw Air Compressors

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Sullair: An Industry Leader

IXON PUMPS. Innovative Fluid Transfer, Filtration, and Tank Cleaning Systems

Filter Cart. hyprofiltration.com/fc

DS V1. Rig Compressors. The most trusted brand in water-well drilling industry Rugged and Reliable

Gerotor pump, fixed displacement volume

Essentials encapsulated kw

PIPELINE INJECTION PRODUCTS

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Series 774 Automatic Skid Package

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

SCR Variable Speed Series Rotary Screw Compressor

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

ELH Series - Hydraulic Fan Drive

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

Duplex Pressure Filters

EG Series Screw Air Compressors Life source of industries

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

Transcription:

OFFLINE SERIES GLOBAL STANDARD COOLER Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com

OIL-to-AIR COOLING SYSTEMS Product Information AKG Offline Series, based on AKG Cool-Line Series, is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known for it`s world-wide presence, German engineering and extremely reliable product quality on the one hand and very competitive prices on the other hand. The AKG Offline series consist of different offline cooler models to be used for cooling, filtration or lubrication circuits at low pressures in industrial or mobile applications. These Offline coolers are also available with noise-optimized models. All of AKG s solutions have been developed with state-ofthe-art technology, produced in compliance with the highest quality standards and are comprehensively tested in the company s own research and test facility. Features of the -series - High-Performance Aluminum cooling assemblies complete with aluminum cooler, fan, guard, integrated gerotor pump/ motor and optional filter. - The heat is transferred from the medium to be cooled to the ambient air. - Ideal for systems with varying flow rates or pressure spikes in return lines. Applications include cooling gearboxes, lube oil, hydraulic presses, CNC machining, injection molding presses, etc. - Suitable for low pressure applications with wide viscosity ranges (up to 000 cst) - Optional filters available on all Offline cooler models. - Integrated cooling system with pump flows ranging from 8.9 gpm up to 4.1 gpm. - Cooler/pump combination can be exposed to operating pressures of up to 1 bar. BENEFITS - Highly flexible, ready-to-connect complete offline cooling package. Requires minimal space and installation effort. - Compact and robust design, field-tested during many years of use in rugged real life conditions. - Largest and most comprehensive series of Offline recirculation coolers. - Best heat transfer results per given cooler size due to comprehensive research and development. - Available from stock or at short notice. - As a standard, equipped with AKG s patented double-life hollow sections designed to increase cooler service life. - Noise-optimized models available (Low-noise L series). /L OFFLINE SERIES FEATURES/BENEFITS New AKG Thermal Systems Offline Cooler series are available in cooler with integrated pump models as well as cooler with integrated pump and filter models. New optimized series offline coolers provides the best HEAT TRANSFER per given cooler size in the industry. New L low noise series offline coolers offer slower fan speeds for reduced noise level & lower fan HP requirements. New /L optimized series offline coolers have proprietary R & D designed, engineered and tested internal and external fins unique to AKG THERMAL SYSTEM coolers. All /L series offline coolers are available with FILTER option. Series Offline Coolers available with 7V, Explosion proof, and custom motors. Contact factory for more information. Series Pump/Motor skid unit available as stand alone item. User can convert Standard Cooler to Offline Cooler using Pump/Motor skid unit. Contact factory for more information. New /L optimized series offline coolers offer the largest, most comprehensive offline cooler size ranges with competitive pricing and deliveries from stock. PATENTED FLEXIBLE AKG HOLLOW PROFILE CooL-Line uses patented AKG hollow profiles to reduce local peak strains. This way the strength of heat exchangers is significantly increased and their service life time considerably prolonged. - Reduced Strain: Strength calculations show that when using AKG hollow profiles maximum strain is reduced by a factor of - Prolonged Service Life Time: Extensive rig tests have shown that service life time increases by a factor ranging from to with standard profile with hollow profile Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com

Performance Data /L10 to /L0 0-40 0 L0-40 0 1 10 0-0 0-40 0-0 10-0 1 10 L0-0 L0-40 L0-0 L10-0 0 0 0 10 0 0 40 0 60 0 10 0 0 40 0 60 Specifications: Pump Type AC Motor Voltages Low-Pressure Gerotor, Fixed Displacement, Self-Priming 08-0/460 @ 60 HZ 190/80 @ 0 HZ Fluids Mineral Oil To DIN 14 Part Max Pressure With Pump Pump Rated Suction Pressure Viscosity Ambient Temperature W/Pump PSI (1 BAR).7 TO.0 BAR 10 TO 000 cst -0 TO 80 C Max Oil Temperature W/Pump 80 C (176 F) Performance Data /L TO /L160 10 80 0 160-100 160-80 10-100 10-80 10-100 10-80 70-100 70-80 -100-80 8 6 4 L160-100 L160-80 L10-100 L10-80 L10-100 L10-80 L70-100 L70-80 L-100 L-80 0 10 0 0 40 0 60 0 10 0 0 40 0 60 Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com

ap/apl Series technical data Model Number Pump Size (CC) and Flow Rate (gpm) @ 60 HZ Fan Motor/Pump Operating Speed @ 60 HZ (RPM) Motor Output @ 60 HZ (HP) Approx Noise Level (db(a), 1 m) Weight (lbs) L L L L /L10 0/8.9 0/.9 7 71 1 /L0 0/8.9 0/.9 40/18. 40/1. 8 74 14 8 74 19 /L0 0/8.9 0/.9 40/18. 40/1. 8 7 180 8 7 19 /L Fan - 0. Fan - 0. 90 81 18 90 81 /L70 Fan - 0.7 Fan - 0.7 9 8 9 8 60 /L10 /L10 /L160 Fan - Fan - Fan - Fan - Fan - 7. Fan - 7. Fan - 1 Fan - 1 Fan - 1. Fan - 1. 9 86 40 9 86 410 97 88 0 97 88 98 89 67 98 89 680 All data based at nominal speed Coolers available with 7V, Explosion proof, and custom motors. Consult factory for more information. Ap/ApL SERIES Dimensions Model Number A B C (Aprox.) D E F G H /L10 1.0 17.70 4.00 4.0 11.0 /L0 18.90.60 4.00 4.0 1.0 /L0.40 7.60 4.00 4.0 19.70 /L 6.0.0 8.00 7.84 19.0 /L70 1.40 8.0 8.00 10.70.00 /L10.0 9.00 48.40 10.70 4.00 /L10 7.60 40.90 0.70 9.80 9.0 /L160 8.40 4.60 46.0 9.90 1.0 1 /16-1 UN-B 1 /16-1 UN-B 1 /16-1 UN-B #0 SAE 1 /8-1 UN-B #0 SAE 1 /8-1 UN-B #0 SAE 1 /8-1 UN-B #0 SAE 1 /8-1 UN-B #0 SAE 1 /8-1 UN-B 1 1/ SAE 1 1/ SAE 1 1/ SAE SAE SAE SAE SAE SAE Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com All dimensions in inch

Cooler Dimensions /L10 to /L0 Cooler Dimensions /L to /L160 ORDERING INFORMATION Model Code: MODEL SIZE: PUMP CODE: FILTER CODE: MODEL CODE: = Standard L = Low Noise MODEL SIZE: Selected (10 to 160) PUMP CODE: 0 = 0CC, Standard 8.9 GPM, Low Noise.9 GPM (Model 10/0/0) 40 = 40CC, Standard 18. GPM, Low Noise 1. GPM (Model 0/0) 80 = 80CC, Standard/Low Noise 6. GPM (Model /70/10/10/160) 100 = 100CC, Standard/Low Noise 4.1 GPM (Model /70/10/10/160) FILTER TYPE: 00 = No Filter, No Hoses or Connectors 41 = Spin-On, 9 Micron Media, 0 PSI Bypass, Visual Indicator, GPM 1 = Spin-On, 9 Micron Media, 0 PSI Bypass, Visual Indicator, 0 GPM NOTE: OTHER FILTERS AVAILABLE, CONSULT FACTORY FOR MORE INFORMATION ORDER EXAMPLE: Offline 0 Cooler, 17 HP, 18. GPM Pump, Spin-On Filter GPM 0-40-41 Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com