ULTRASONIC FLOWMETER TIME DELTA-C

Similar documents
Applicable pipe diameter is 13mm to 6000mm

ULTRASONIC FLOWMETER <

ULTRASONIC FLOWMETER < >

PORTABLE TYPE ULTRASONIC FLOWMETER

Time Delta S Fixed Transit-Time Flow Meter System

SERIES ULTRASONIC FLOWMETER

PORTABLE TYPE ULTRASONIC FLOWMETER

SERIES ULTRASONIC FLOWMETER

ULTRASONIC FLOWMETER < S (Standard Type)> DATA SHEET

ULTRASONIC FLOWMETER < >

Ultrasonic Flowmeters

ULTRASONIC FLOWMETER M-Flow

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Instruction Manual ULTRASONIC FLOWMETER TYPE: UXF1 SX1, PSX2 ULTRASONIC FLOW METER. Dwyer Instruments, Inc. Bulletin F-69

FEATURES SPECIFICATIONS FSV-2, FSS, FLY SERIES ULTRASONIC FLOWMETER < > DATA SHEET. Operational specifications. EDSX6-142b. Flow transmitter (FSV S)

UL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

Portable Ultrasonic Flow Measuring System prosonic flow 92

Ultrasonic Flowmeters

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

UTM10 Series Ultrasonic Transit-time Flowmeters

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Liquid Turbine Flow Meter OwnerÊs Manual

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Inline Ultrasonic Flowmeter

Paddle-wheel flow controller for On/Off control

Appendix. Clearance. Skewed profiles. Application Schematics

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Octave Water Meter Installation Manual

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

PORTABLE TYPE ULTRASONIC FLOWMETER (PORTAFLOW-C)

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Paddle-wheel flow controller for On/Off control

SRT1000 Series THERMAL FLOWMETER

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

TRANSIT TIME FLOW METERS

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

FLOWX3 F3.60M.S Insertion Magmeter

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

EASZ-10P Operating Instructions

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Ultrasonic Sludge Blanket Monitoring System

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

TOWA SEIDEN INDUSTRIAL CO., LTD.

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

F-2600 SERIES INLINE VORTEX FLOW METER

An Innovative Flow Sensor

Model TUR-200D Turbine Flowmeter

F-1500 SERIES INSERTION TURBINE FLOW METER

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

mass flowmeter for compressed air

Fuji Instrumentation & Control. Flowmeter. Series ECNO:620

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Model DFX Doppler ultrasonic flow meter

better measurement Simply a question of

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Signet 2551 Magmeter Flow Sensor

JUMO ecotrans Lf 01/02

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

OVERVIEW OF CONTROLS

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Application. Battery. Public Grid GS HYBRID INVERTER

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

F-2700 SERIES INSERTION VORTEX FLOW METER

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

Ultrasonic Sludge Blanket Monitoring System

Electromagnetic flowmeter. Descriptions. Specifications

Pressure Transmitter

Digital Engine Tachometer

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide

Electromagnetic Flowmeters. Product Overview.

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Vortex Eggs Delta Flowmeter

Transcription:

Fuji Instrumentation & Control ULTRASONIC FLOWMETER TIME DELTA-C The latest advance in high performance transit time flow measurement Superior signal processing and best-in-class anti-bubble performance in a compact and lightweight package (FLS) transmitter (FSV...S) High accuracy measurement :.0% of rate Superior anti-bubble performance : Our Advanced ABM method is adopted. Maintenance free operation : Non-invasive setup with no moving parts Compact and lightweight : Size and mass reduced by 2/3 (compared with model FLV). Flexible communication functions : RS-232C or RS-485 (MODBUS) Wide application range : 3 to 6000mm applicable pipe diameters Quick and easy setup : Simple menu guided setup from the front panel or PC interface Advanced ABM method: anti-bubble measuring method. ECNO:636d

Applicable pipe diameter is φ3mm to φ6000mm High accuracy measurement of fluid flow rate:.0% of rate Quick response: 0.2 sec. or less (quick response mode) Minimal Influence by the pressure of measured fluid and temperature Superior anti-bubble performance (Advanced AMB method * is adopted.) * Advanced ABM method: anti-bubble measurement method Advanced received signal digital processing results in higher performance flow measurement Normal propagation Propagation interrupted by bubble Bubble Bubble v Received signal : t Summed 28 or 256 times for a single output v Received signal : Nothing Digital data of the received signals : v Synchronized summation of received signals t t In the case of an analog system, measurement failure will occur. Acceptable value of bubble quantity 2 0 2 (Note) meter indicates the volumetric flow rate, including bubbles. 8 7.0 Advanced ABM method 6 4 4.0 Conventional method.5 [vol.%] 2.2 0.4 0.03 0.02.0 2.0 3.0 4.0 5.0.0 0.02 velocity [m/s] A wide range of detectors is available, and no piping work is required (A detector is simply attached to the exterior of the piping.) Classification Appearance type Applicable pipe inner diameter (mm) Measured fluid temperature Mounting/structure Compact type FLSE φ25 to φ00 FLSE2 φ50 to φ225-20 to 00 C or 0 to 20 C V method mounting Jet structure (equivalent to IP65) Small diameter type High temperature type FSD22 φ3 to φ00-40 to 00 C FSD32 φ50 to φ400-40 to 200 C Common type FSGS3 φ50 to φ300-40 to 80 C V mounting method Watertight structure (equivalent to IP67) V or Z method mounting Splash-proof structure (equivalent to IP52) V method mounting Watertight structure (equivalent to IP67) Submersible type available Large diameter type FSGS4 φ200 to φ200 FSGS5 φ200 to φ6000-40 to 80 C V or Z method mounting Watertight structure (equivalent to IP67) Submersible type available Measuring principle With ultrasonic pulses propagated diagonally between the upstream and downstream sensors mounted on the exterior of the pipe, the flow rate is measured by detecting the time difference caused by the flow. Sensor Sensor 2

Both the mass and volume of the flow transmitter are reduced by 2/3! Compact and lightweight flow transmitter (/3 size of model FLV) Easy to carry and install on a system <Our FLV type> <Our FSV type> 70mm 220mm Mass: approx.5kg Mass: approx 4.5kg 230mm 42mm Mounting method: wall or pipe mounting Operation can be performed from the outside panel (In case of IP66 type) Various settings can be made from the front side without opening the cover of the flow transmitter. (Parameter setting, input of mounted pipe data, automatic calculation of mounting dimensions and similar) Parameter setting and data collection can be performed via optional PC communications interface. Normal: green / Extraordinary: Red Instantaneous flow velocity value (8-digit display) Total flow rate value (8-digit display) Waterproof keypad LCD display with backlight is clearly legible, even in dark places. RS232C or RS485 Communication PC loader software for the setting of various parameters and the collection of measured data is a standard accessory (Note) The communication cable for PC loader is an optional accessory. (Type: ZZP*TK4J236) Signal and process interfaces are designed with functionality as priority. Input signal from the detector No-voltage contact input (option point) (zero adjustment, total value preset) Analog output point (4 to 20mA, insulated) (with arrester, max. load resistance: k) Relay contact output point (insulated, with arrester) Output frequency: P/s max., pulse width 50 to 200ms Transistor contact 2 points (insulated, with arrester) Output frequency: 000P/s max., pulse width 5 to 200ms) Communication signal (RS232 or RS485 communication) (Insulated, with arrester) Power supply voltage (with arrester, 00 to 240VAC or 20 to 30VDC) Fully equipped with extensive functions Zero adjustment Damping Low flow rate cut Alarm contact output Output burnout Forward and backward ranges Auto 2-range switch Total value switch one-touch adjustment while the flow is stopped Used to reduce the fluctuation of the measured value. Setting range: 0 to 00 sec. (setting per 0. sec.) Output may be cut when the flow rate is low. Setting range: 0 to 5m/s (setting in 0.0m/s unit) Contact output at condition of hardware and process faults When measurement cannot be made because the pipe is empty or bubbles are entrained in the fluid, contact output is activated while analog output is held. Ranges may be set arbitrarily. The digital output of the operation range is available. 2 forward ranges are independently configurable. Digital output of operation is available. Contact output is made when the upper or lower limit values of the instantaneous flow rate are reached Contact output is made when the upper limit value of the total flow rate (forward) exceeds the setting value. Display of various units Unit may be set in m/s, L/s, L/min, L/h, L/d, KL/d, ML/d, m 3 /s, m 3 /min, m 3 /h, m 3 /d, Km 3 /d, Mm 3 /d Multilingual display The display language may be selected from 5 choices, including Japanese (Katakana), English, French, Spanish and German. 3

Application example The ultrasonic is a liquid used in various applications.. Measuring system for the paint flow rate The flow rate of thick paint is measured by a detector mounted on the pipe already constructed. Paint (red) transmitter Paint (blue) transmitter Paint (yellow) transmitter 2. An energy-saving system for measuring and controlling the flow rate of a pump A detector is attached to the already constructed pipe to measure the flow rate at the pump outlet, and a regulator is used to implement inverter control of the pump. Pump Inverter transmitter (type: FSV) Application: To pump underground water Pump Application: Water supply to high-rise condominiums and buildings Pump rate regulator (type: PXH) Water supply (type: FLS) 3. rate measurement in a water purifying system for semi-conductors Advantages of using an ultrasonic for the system 4. A system for measuring heat transfer and efficiency Heat is transferred by water flow in the process of HVAC loop ) It can be easily mounted on the exterior of a pipe, helping reduce mounting cost. 2) As a sensor, it can operate without coming into contact with fluid, so the fluid is not affected by metallic ions. 3) This meter, compact and lightweight, can be easily carried and mounted. Raw water Electromagnetic transmitter (type: FSV) (type: FLS) Ultrapure water is supplied Measurement of the raw water flow rate Semi-conductor manufacturing device It can be mounted on the pipe already constructed. Small, lightweight and easy to mount Computing unit Heat source Temperature sensor T: Temperature of the heating medium on the emitting side Temperature sensor T2: Temperature of the heating medium of the receiving side Consumed heat quantity signal (4 to 20mADC) Heat quantity total value pulse signal (DO) Consumed heat quantity K: heat quantity conversion factor (For heating K = 4.23) transmitter (type: FSV) (type: FLS) Q: rate of the heating medium Load Major applications Backup for the already constructed Water supply and sewage systems... leakage investigation of water pipe and investigation of the flow direction in the water distribution pipe Power plant...flow rate measurement of the boiler water supply, condenser circulating pump and turbine oil Various plants...flow rate measurement of cooling water, plating solution and corrosive liquid Food manufacturing plan...flow rate measurement of raw material and washing water Semiconductor manufacturing plant...flow rate measurement of pure water Air-conditioning equipment...flow rate measurement of hot water and chilled water in heating and cooling Hot spring...measurement of suction quantity 4

CODE SYMBOL transmitter IP66 IP67 (Language) (4th digit) Standard (Communication) (5th digit) RS232CDI RS485DI (6th digit) Single measuring path (Power supply)(7th digit) 00 to 240VAC 50/65Hz 20 to 30VDC (Case structure) (9th digit) IP66 IP67 (Wire connection port) (0th digit) Weatherproof gland provided Union (for plica) with gland [G/2 female screw] (when "H" is specified 9th digit) (Combination with an explosion-proof detector) (th digit) (Parameter setting) (2th digit) Setting provided Setting provided + tag Tag (Mounting method) (3th digit) Pipe mount (if the 9th digit is S) Wall mount Pipe mount (if the 9th digit is H) (Area) (4th digit) America Europe, Middle East, Africa Asia, common / large diameter type Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) Small sensor MHz (ø50 to ø300)* 2 V method Middle sensor MHz (ø200 to ø200) Large sensor MHz (ø200 to ø6000) V or Z Large sensor 0.5KHz (ø200 to ø6000)* 2 method Acoustic coupler (0th digit) * 5 Silicon rubber (KE348) Silicone-free grease (HIGH-Z) (Note 2) Silicone grease (G40M) (Note 2) Additional specification (th digit) Tag plate Wire rope for mounting (2th digit) Specify it in the case of FSGS4 or FSGS5. Nominal diameter: up to ø500mm Nominal diameter: up to ø000mm Nominal diameter: up to ø500mm Nominal diameter: up to ø3000mm Nominal diameter: up to ø6000mm Can be specified only for FSGS5 *2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select FSGS3 or FSGS50. *3: Procure type FLY for the signal cable. *5: Silicone rubber (KE-348W) is provided as a standard accessory to fill the wiring mold. (It can also be used as an acoustic coupler.) If an additional acoustic coupler is required, select one among A, B and C., small diameter/high temperature type Smoall diameter senser(3 to 00)V method High-temperature senser* (50 to400)v or Z method *: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, use an optional guide rail (TK4C664C), and carry out mounting by Z method. Applicable diameter range V method: ø50 to ø250 Z method: ø50 to ø400 Note: As standard acoustic coupler, silicone rubber (KE-348W) is provided for small diameter sensor, or grease for high temperature (KS62M) for high-temperature sensor., Compact type 3 Note : When the 9th digit in the code symbol is A, the applicable piping diameter is up to 50mm. Note 2: Normally silicone rubber is selected as an acoustic couplant. Silicone rubber is provided in a tube (00g). If you place an order for several units, tube may suffice for every 5 units.select silicone-free grease for semiconductor equipment or similar that is vulnerable to silicone. The silicone-free grease is water-soluble and cannot therefore be used in an environment exposed to water or on piping subject to condensation. Since the grease does not set, periodic maintenance (cleaning, refilling every about 6 months at normal temperatures) is necessary. Note 3: Select silicone grease for Teflon-coated piping. Version (4th digit) Standard Type (5th and 6th digits) Small diameter detector (25 to 00mm) Small detector (50 to 225mm)(note ) Acoustic coupler (7th digit) (Note 2) Silicone rubber Silicone-free grease (Note 3) Fluid temperature range (9th digit) -20 to 00 C -0 to 20 C Optional specification (0th digit) Tag, submersible type Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) Small sensor MHz (ø50 to ø300)* 2 Middle sensor MHz (ø200 to ø200) Large sensor MHz (ø200 to ø6000) Large sensor 0.5KHz (ø200 to ø6000)* 2 Dedicated signal cable (9th digit) 0m 20m 30m 40m 50m 60m 70m 80m 90m 00m 0m 20m 30m 40m 50m Specified length (Contact us if length is more than 50m. Max. length is 300m.) Acoustic coupler (0th digit) Silicon rubber (KE348) Silicone grease (G40M) (Note 2) Additional specification (th digit) Tag plate Wire rope for mounting (2th digit) Specify it in the case of FSGS4 or FSGS5. Nominal diameter: up to ø500mm Nominal diameter: up to ø000mm Nominal diameter: up to ø500mm Nominal diameter: up to ø3000mm Nominal diameter: up to ø6000mm V method V method V or Z method Can be specified only for FSGS5 *2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select FSGS3 or FSGS50. Scope of delivery transmitter (when you choose pipe mount option provided with a U-bolt for pipe mounting) (provided with a mounting fixture and acoustic couplant) *in case of conpact type detector acoustic couplant is option. CD-ROM (contains an instruction manual and loader software for PC communication) Optional accessories () Signal cable (type: FLY) (2) Loader cable (type: ZZP*TK4J236) Cable between detector and flow transmitter Note: Cable is attached for a submersible detector. 5

Specifications Applicable subjects and operation environment Applicable fluid Applicable piping and fluid temperature Homogeneous liquids capable of ultrasonic wave propagation Bubble quantity: 0 to 2Vol% (reference diameter 50A, water and flow velocity of m/s) Turbidity of fluid: 0000 degrees (mg/l) or less Straight pipe length: upstream side 0D or more, downstream 5D or more (D: pipe inner diameter) State of flow: fully developed turbulent or laminar flow in round pipe filled with fluid Classification type Pipe inner diameter (mm) Applicable pipe material Mounting method Fluid temperature range (Note 3) φ25 to φ00 Plastic (PVC, etc.) (Note ) The 9th digit of the FLSE2 Metal pipe (SS, steel pipe, copper φ50 to φ00 code symbols pipe, aluminum pipe, etc.) (Note 2) Y : -20 to 00 C Compact type V method Plastic (PVC, etc.) (Note ) A : 0 to 20 C (Note 4) FLSE22 φ50 to φ225 Metal pipe (SS, steel pipe, copper Heat shock resistance 50 C for 30 min. pipe, aluminum pipe, etc.) (Note 2) Small diameter type FSD22 φ3 to φ00 V method -40 to 00 C Common type FSGS3 φ50 to φ300 Plastic (PVC, etc.) (Note ) V method FSGS4 φ200 to φ200 Metal pipe (SS, steel pipe, copper -40 to 80 C Large diameter type FSGS5 φ200 to φ6000 pipe, aluminum pipe, etc.) (Note 2) V or Z method High temperature type FSD32 φ50 to φ400-40 to 200 C Note : If the pipe material is PP or PVDF, select FSGS3, FSGS4 or FSGS50. Note that the wall thickness is 5mm or less for PP, 9mm or less for PVDF. Note 2: For cast iron pipes, lining pipes, old steel pipes or similar, through which the ultrasonic signal cannot easily be transmitted, select FSGS3, FSGS4 or FSGS50. Lining material: Tar epoxy, mortar, rubber, etc. * In case the lining suffers from peeling-off, measurement may be impossible. Note 3: If silicone-free grease is used as an acoustic couplant, the fluid temperature range is 0 to 60 C, regardless of the detector. Note 4: When the 9th digit in the code symbol is A, the applicable piping diameter is up to 50mm. 0 to ±0.3... ±32m/s 00 to 240VAC 50/60Hz or 20 to 30VDC 5VA or less (AC power supply), 6W or less (DC power supply) Coaxial cable (60m max. for compact type detector (FLS), 300m max. for other others) Heat resistance: 80 C Non-explosive area not exposed to direct sunlight, corrosive gas or heat radiation velocity range Power supply voltage Power consumption Signal cable (between the detector and converter) Installation environment Ambient temperature transmitter: -20 to 55 C : -20 to 60 C or -20 to 80 C (FLSE2 2 -A) Ambient moisture 95% RH max. Grounding Class D (00Ω) Arrester Provided as standard at the output and power supply Performance specifications Accuracy rating Classification type Pipe size (inner diameter) Accuracy velocity Applicable pipe material φ25 toφ50 2.0% of rate 2 to 32m/s 0.04m/s 0 to 2m/s FLSE2 φ50 to φ00.0% of rate 2 to 32m/s 0.02m/s 0 to 2m/s Plastic Compact type φ50 to φ00 2.0% of rate 2 to 32m/s 0.04m/s 0 to 2m/s Metal pipe FLSE22 φ50 to φ225.0% of rate 2 to 32m/s 0.02m/s 0 to 2m/s Plastic φ50 to φ225 2.0% of rate 2 to 32m/s 0.04m/s 0 to 2m/s Metal pipe Small diameter type FSD22 φ3 to φ50 2.5% of rate 2 to 32m/s 0.05m/s 0 to 2m/s φ50 to φ00.5% of rate 2 to 32m/s 0.03m/s 0 to 2m/s Common type FSGS32.0% of rate 2 to 32m/s φ50 to below φ300 High temperature type FSD32 0.02m/s 0 to 2m/s.0% of rate 0.75 to 32m/s Large diameter type FSGS5 φ300 to φ6000 0.0075m/s 0 to 0.75m/s Plastic, metal pipe Common type FSGS3.5% of rate 2 to 32m/s φ50 to below φ300 FSGS4 0.03m/s 0 to 2m/s Large diameter type.5% of rate 0.75 to 32m/s FSGS50 φ300 to φ6000 0.03m/s 0 to 0.75m/s Response time 0.5 sec. (standard mode), 0.2 sec. depending on setting (quick response mode) 6

Functional specifications Analog signal Digital output Digital input Serial communication Display device Indication language velocity / flow rate indication Total indication Setting function Zero adjustment External zero adjustment Damping Low flow rate cutoff Alarm Burnout Bi-directional range Auto 2-range switch Total switch Physical specifications Type of enclosure Mounting method Acoustic couplant Note: The acoustic couplant is a medium that eliminates the gap between detector and pipe. Outer dimensions, mass 4 to 20mA DC ( point), Load resistance: kω max. Forward total, reverse total, alarm, acting range, flow switch, total switch assignable arbitrarily () Mechanical relay contact (isolated, socket provided, arrester incorporated) (2) Transistor contact (isolated, open collector, arrester incorporated) Output: point Output: 2 points Normal: Open/Close selectable Normal: ON/OFF selectable Contact capacity: 240VAC/30VDC, A Contact capacity: 30VDC, 0.A Output frequency: P/s max. (pulse width: 50, 00, 200ms) Output frequency: 000P/s max. (pulse width: 5, 0, 50, 00, 200ms) point (no-voltage contact)/set zero, preset total assignable RS-232C equivalent or RS-485, isolated, arrester incorporated Connectable quantity: unit (RS-232) /up to 3 units (RS-485: MODBUS) Stop bits: or 2 bits selectable Baud rate: 9600, 9200, 38400bps Cable length: 5m max. (RS-232C)/km max. (RS-485) Parity: /Odd/Even selectable Data: velocity, flow rate, forward total, reverse total, status, etc. 2-color LED (Normal: green, Abnormal: red), LCD display (2 lines of 6 digits, back light provided) Japanese (Katakana), English, French, German, Spanish (switchable) Instantaneous flow velocity / instantaneous flow rate indication (minus indication for reverse flow) Numerals: 8 digits (decimal point is counted as digit) English and metric units selectable. Metric system Inch system Unit: Velocity m/s ft/s rate L/s, L/min, L/h, L/d, kl/d, ML/d, m 3 /s, m 3 /min, m 3 /d, km 3 /d, gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, ft 3 /s, ft 3 /min, ft 3 /d, Kft 3 / Mm 3 /d, BBL/s, BBL/min, BBL/h, BBL/d, kbbl/d, MBBL/d d, Mft 3 /d, BBL/s, BBL/min, BBL/h, BBL/d, kbbl/d, MBBL/d Forward or reverse total value indication (negative indication for reverse direction) Numerals: 8 digits (decimal point is counted as digit) English and metric units selectable. Metric system Inch system Unit: Total ml, L, m 3, km 3, Mm 3, mbbl, BBL, KBBL gal, kgal, ft 3, kft 3, Mft 3, mbbl, BBL, kbbl, ACRE-ft Setting available with 4 keys (ESC,,, ENT) on the front Set zero/clear available Set zero available by digital input setting 0 to 00s (setting per 0. sec.) for analog output and flow velocity/flow rate indication 0 to 5m/s in terms of flow velocity Digital output available for Hardware fault or Process fault Analog output: Hold /Over-scale/Under-scale/zero (selectable) rate total: Hold/Count (selectable) Burnout timer: 0 to 00s (every s) Forward and reverse ranges configurable independently / Hysteresis: 0 to 0% of working range / Working range applicable to digital output 2 forward ranges configurable independently / Hysteresis: 0 to 0% of working range / Working range applicable to digital output Lower limit, upper limit configurable independently (Digital output available for status at actuated point) Upper limit of the forward total settable (Digital output available when actuated) transmitter: IP66 or IP67 / : IP52/IP65/IP67 (Depend on ditector type) Mounted on wall or by 2B pipe / : Clamped on existing piping. Silicone rubber, silicone grease or silicone-free grease Type Silicone rubber (type:ke-348w) Silicone grease (type:g40m) Silicone-free grease (type:high Z) Grease for high temperature (type:ks62m) Fluid temperature -40 to +50 C -30 to +50 C 0 to +60 C -30 to +250 C Teflon piping Not usable Good Good Good See outline diagrams. Loader software (standard accessory) Compatible PC model Main function OS Memory requirement Hard disk capacity PC/AT compatible instrument Operation is undefined for PC98 series (NEC) Software for setting/change of the main unit parameters and for collection of the measured data on PC Windows 2000/XP 25MB min. Minimum free space of 52MB or more Note: Loader cable (code symbol ZZP*TK4J236) is additionally required. Connection diagram Earth terminal (M4) AC power supply L 2 N 3 4 00 to 240VAC 50/60Hz DC power supply 2 3 4 20 to 30VDC 2 3 4 5 6 7 8 9 DO TR out DO2 TR out Max. 30VDC, 0.A DO3 RELAY I out Max. 240VAC/ 30VDC, A 0 GND To the upstream-side sensor 2 3 HF GND HF2 * SH To the downstream-side sensor * Only for double shield cable (type FLY8, 9) * SH Option DI Status input 2 3 4 SHILD TXDR2 TXDR RS-485 DI 2 3 GND RXD 4 TXD RS-232C Status input M3 screw 7

Meter Outline diagram of the flow transmitter (unit: mm) IP66 type transmitter Type: FSV...S (Weight:.5kg) 2.5 2.5 Mounting plate 75 42 70 0 Mounting hole 9x0 IP67 type flow transmitter Type FSV H (Weight: 4.5kg) U-bolt (M8) 20 2-9 72 5.7 95 4 230 Earth terminal 39 220 0 9 U-bolt (M8) SS tag ESC ENT 70 200 (233) 277 32 Mounting Pipe (2B) TIME DELTA-C 25 Cable gland 53 Bracket Earth terminal (M4) Mounting Pipe For sensor cable (PF3/8) For power supply/output cable (PG3.5) For power supply/output cable (PF/2) 40 40 40 40 For sensor cable (PF/2) Outline diagram of detector (unit: mm) Compact type detector Type: FLSE (diameter φ25 to φ00) Type: FLSE2 (diameter φ50 to φ225) SS tag L Common type detector Type: FSGS3 (diameter φ50 to φ300, Weight: 0.6kg) 5 Frame Sensor 40 400 5 Sensor BNC connector Frame Lock clip H 50 50 33 47 Spacing : 0 to 270mm 34 28 Mounting spring Spacing (Adjustment by every 3mm) Type Pipe size (mm) L FLSE2 25 to 00 FLSE22 50 to 225 228 348 H 3 30 Spacing 2 to 20 2 to 240 Mass approx.(kg) 0.3 0.4 46 Scale (inch) BNC connector Scale (mm) Saddle Saddle Spacing 0 to 330 Name plate Lock nut Element holder Spacing 0 to 33 Scale (inch) Cursor inch mm Scale (mm) BNC connector Lock nut Element holder 320 37 54 Wire rope 78 84 Wire rope 26 Cursor High-temperature sensor Type: FSD32 (diameter φ50 to φ400, Weight:.6kg) 90max 52.5 36 Small diameter sensor Type: FSD22 (diameter φ3 to φ00, Weight: 0.6kg) 46 Large diameter sensor Type FSGS4 (diameter φ200 to φ200, Weight: 0.3kg) 67 Large diameter sensor Type: FSGS5 (diameter φ200 to φ6000, Weight:.2kg) Caution on Safety * Before using products in this catalog, be sure to read their instruction manuals in advance. International Sales Div.5 Sales Group Gate City Ohsaki, East Tower, -2, Osaki -chome, Shinagawa-ku, Tokyo 4-0032, Japan http://www.fesys.co.jp/eng Phone: 8-3-5435-7280, 728 Fax: 8-3-5435-7425 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan 200-/**FIS