KAWAMOTO PACKAGED BOOSTER PUMP UNIT <NON-INVERTER TYPE> 2 POLES / 50 Hz SUCTION SIZE JIS 32~65

Similar documents
VERSION 1 VU4. KAWAMOTO SUBMERSIBLE PUMP 4 POLES / 50 Hz SIZE MM. 100 % SOLID PASSAGE MODEL VORTEX IMPELLER KAWAMOTO PUMP ASIA CO.,LTD.

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

3-Way Ball Valve Type 23H

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

3M TM Filter Housing 1BS-T/1BS-TW Series

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Butterfly Valve Type 58 (PDCPD)

Diaphragm Valve Type 72

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Submersible Pump Instructions. Safety Instructions

MPC-B2800 User manual Maxell Rechargeable Power Bank MPC-B2800

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Battery Unit BHM60PC/BHM100PC Instruction Manual

TPAK Series COOLANT PUMP

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

PRESSURE BOOSTER 150

KINESIS K3 ONE (1) YEAR LIMITED WARRANTY AND RETURN POLICY

GL Ludemann Y-Strainers

I. Safety precautions

Handling Precautions, Prohibitions and General Supply Notices for VARTA Microbattery GmbH CoinPower Lithium-Ion Batteries

Diaphragm Valves Type 15

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

USER S GUIDE FOR AUTO TRANSMISSION FLUID

OPERATOR'S MANUAL Model CHL91302 Battery Charger for use with LITHIUM EARTHWISE Lithium-ion Battery Pack

Oil Pump. Features: AISIN aluminum die-casting technology allows for size and weight reduction.

Installation Manual DIAPHRAGM WELL TANK

MULTI-CHARGER FOR 12 TO 18V NI-CD OR LI-ION BATTERIES

Butterfly Valve Type 57P

Instruction Manual. Q Series 2 Motor Control Modules - OEM

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

Please take time to read and understand the following

BRAVER UPS. (Uninterruptible Power System) User s Manual

IN120L / IN120LB / TM120L/TM120LB IN2400L

BOSTON TOWER MERCHANDISER ILLUMINATION KIT (P/N ) INSTALLATION INSTRUCTIONS

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Operator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

ESC Series Engine Shutdown Control

Butterfly Valves ASAHI AV VALVES

Owner s Manual & Safety Instructions

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

PL Submersible, Semi-Vortex, Water Feature Pump

STANDARD OPERATING PROCEDURE

IN & TM Series User Manual

Manufacturer Kakogawa, Japan DC5S

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

PE 20 SERIES ELECTRIC POWER PUMPS

SANWA STAINLESS STEEL MAGNET DRIVE PUMP INSTRUCTION MANUAL. Request to Users

EEMB CO., LTD. Specification

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Owner's Manual. Safety Instructions Customer Care Warranty. Safety Instructions. This Product is Distributed Exclusively by

COMPRESSORS REPLACEMENT PROCEDURE

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

EEMB CO., LTD. Specification

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1

Hydraulic Immediate Need Power Pack

AQUARIUMVAC.COM TOBOQ AQUARIUM WATER PUMP & VACUUM. User Manual V 1.0

P/N Water/Methanol Injection V2 Nozzle Kit Includes T-Fitting, Hose, 250cc, 500cc, & 1000cc Jets STOP!

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

MODEL P INSTALLATION INSTRUCTIONS

Air duct switching damper

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

12 Volt Heavy-Duty Air Inflator

Submersible Tank Pump

OPERATING MANUAL 18V Ni-Cd Battery Pack

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

12V CONSTANT PRESSURE PUMP

Specifications. Important Safety Information

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

12V Oil Extractor Pump

Hydraulic PTO Flow Device

Thank you for selecting the GD submersible grinder pump.

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

EEMB CO., LTD. Lithium Thionyl Chloride Battery Specification. High Power Type. Prepared Checked Approved. Signature Checked Approved

Driver Drowsy Warning System

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Guide

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Operating Instructions & Parts Manual. Portable Power Supply & Jump Starter ! WARNING

DELUXE TELESCOPING LANCE ASSEMBLY

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Thank you for purchasing a Borla Performance Stainless Steel Header.

Voltmaster Centrifugal Trash Pumps

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

FHM Series. Magnetic Separator. RoHS FH HOW

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

SUNC3000 / Item #40885

Lithium Polymer Rechargeable Battery Pack Tested and approved to UN38.3

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

60 Watt Industrial LED Low Bay Light

SS/SSH Submersible Pump. Owner s Manual

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

CHECKING COOLING SYSTEM - AS OF MY 2003 (ALL MODELS)

TactAir 4-Stage PCP Hand Pump. Operation Manual

Transcription:

KAWAMOTO PACKAGED BOOSTER PUMP UNIT <NON-INVERTER TYPE> 2 POLES / 50 Hz SUCTION SIZE JIS 32~65

APPLICATIONS AND FEATURES AUTOMATIC OPERATION CONSTANTPRESSURE PUMP PACKAGED PUMP UNIT COMPLETE WITH PUMP(s),CONTROL PANEL, PRECHARGED PRESSURE TANK(ACCUMULATOR), VALVES, SWITCHES ETC., READY FOR INSTALLATION SUITABLE FOR DRINKING WATER AS IT IS NO FEAR OF MAKING RED DISCOLOUMENT OF WATER SPECIFICATIONS 1

APPLICATIONS AND FEATURES MICRO-COMPUTER MONITORING (ALTERNATE AND ALTERNATE/PARALLEL OPERATION TYPE) STATUS OF INDIVIDUAL DISPLAY 2

SELECTION ALTERNATE OPERATION ALTERNATE/PARALLEL OPERATION SPECIFICATIONS 3

CONTROL PANEL <TYPE:ECFW-F> SPECIFICATIONS 4

DIMENSIONS 5

DIMENSIONS 6

DIMENSION DIAGRAM - 3PHASES 380V L1 L2 L3 U1 V1 W1 U2 V2 W2 A1 A2 A3 A10 A11 E4 E5 E32 E31 A4 A5 A6 A7 A8 A9 E3 E2 E1 7

VERSION 1 WIRING DIAGRAM - 3 PHASES 380V 8

DIMENSION DIAGRAM - 1 PHASE 220V L1 N U1 V1 U2 V2 A1 A2 A3 A10 A11 E4 E5 E32 E31 A4 A5 A6 A7 A8 A9 E3 E2 E1 9

CIRCUIT DIAGRAM - 1 PHASE 220V 10

SECTION VIEW VIEW A VIEW B 11

VERSION 1 PUMP DATA 12

MOTOR DATA & OPTIONAL EQUIPMENT MOTOR DATA OPTIONAL EQUIPMENT 13

SECTION VIEW UNIT PUMP PARTS LIST MAIN PUMP PARTS LIST 12 11 10 7 8 2 3 1 4 5 13 9 6 14

IMPORTANT SAFETY PRECAUTIONS Always read the manual thoroughly and fully comprehend the contents for safe operation before starting use. Precautions for using products safely and for preventing personal injuries or physical damage are given in the manual. Matters falling under the following may not be covered by the warranty: uses out of the specified scope of application, failure to comply with precautions, improper repairs and alterations, matters arising from natural disasters, matters arising from the installation environment (improper power source, foreign objects, sand etc.), non-compliance with laws and regulations or standards pertaining thereto, accidental or intentional damage or injury, replacement of consumable parts, defects due to resale, etc. Do not use the product for applications out of the product specifications. Doing so may cause electric shock, fire, water leakage, etc. Have spare equipment ready when using pumps for equipment for living things (fish farms, fish tanks, aquariums, etc.) or critical equipment. Pump failure may cause lack of oxygen and water quality deterioration, and may affect the lives of the living things. When using pumps for equipment for living things (fish farms, fish tanks, aquariums, etc.), do not install the pump in the tank where the living things are put into. The current leakage or sealing liquid leak from the mechanical seal may cause the death of the living things. If used to transport food-related items, give due consideration to the materials used. Contamination by foreign objects may occur. Avoid using for living things which disagrees with copper alloy. It may affect the lives of the living things. Select a product which is appropriate for your application. Inappropriate use of products may cause accidents. Conduct construction in accordance with the applicable laws and regulations (the Technical Standards of Electric Installation, interior wiring regulation, Building Standards Act, Water Supply Law, etc.). Not only does it violate the laws and regulations, but it also may cause injuries due to electric shock, fire, falling and tipping over. Do not use in places where people are assumed to get in contact with the product (baths, pools, lakes, etc.). Electric leak may occur and cause electric shock. Depending on the equipment, attach a filter etc. appropriate for your application on the discharge side before use, perform thorough flushing to check that there is no contamination. Cutting oil, rubber mold releasing agent, foreign objects etc. from the manufacturing line and cutting oil, foreign objects etc. from the pipeline may contaminate the liquid which is to be handled. Do not operate pumps with a specification of at 60Hz. It may cause damage due to overpressure or burn damage of motors etc. due to overload. Do not operate pumps with a specification of 60Hz at. Pump performance may be reduced. Only repair technicians may disassemble, repair, modify the product or replace cables. Defects may cause failure, damage, electrification or fire. It is recommended that both periodic and daily inspections be performed in order to ensure that the pump will operate reliably for as long as possible. Failure to perform inspections may lead to pump failure, accidents etc. For periodic inspections, please consult your distributer or our nearest sales office. Note Specifications/Configurations may be altered as a result of improvements and such. Unauthorized reproduction of this document is prohibited. 15