Fusible Link (replaceable) Horizontal Mount

Similar documents
Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-212. Combination FIRE SMOKE DAMPERS

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Fire Dampers Catalogue

HCD-230 Industrial Control Damper

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

CURTAIN TYPE FIRE DAMPER

table of contents PRODUCT SUMMARY 2

MODEL 151B FIRE DAMPER

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Motorized Fire Dampers

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20 3V CONTROL DAMPER

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Fire, Smoke, and Combination Fire Smoke Dampers

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

AMD-33 Air Measuring Station with VCD-33 Control Damper

MULTI-BLADE FIRE DAMPERS

VCD-23. Flange Options. Size Limitations

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

MULTI-BLADE FIRE DAMPERS

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

VCD-23 Low Leakage CONTROL DAMPER

Installation, Operation and Maintenance Instructions

SD-1250 and SD-1600 Series Smoke Dampers

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Model VCD-43 Extruded Airfoil Blade Control Damper

Smoke Dampers. Installation Instructions

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Installation, Operation and Maintenance Manual

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Thermal Isolation. Break

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

SMOKE DAMPER - CLASS F MODEL BMSD

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Part # Installation,Operation and Maintenance Instructions

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

HVAC Control & Balancing Dampers

AIR DUCT ACCESSORIES

CFSD Series. Product Description

BC 03. Fire Dampers FD-GB-30-AS LISTED

Nobody delivers dampers and louvers faster!

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Propeller Hooded Roof Fans

Installation, Operation and Maintenance Manual

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Air Measuring Products AMD AMS IAQ

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Installation, Operation, and Maintenance Manual. Automatic Fire Damper


Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

CEILING & INLINE/CABINET VENTILATORS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

University of Delaware

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Transcription:

Application Model SSFD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a 2 hour UL fire damper label. UL555 classifies static rated fire dampers for use in HVAC systems that are automatically shut down in the event of fire. SSFD-50 is contructed out of 04 stainless steel. Ratings UL555 Fire Resistance Rating Fire Rating: 2 hours Model SSFD-50 Static Rated Fire Dampers 2 Hour Fire Resistance Rating Construction Standard Optional Frame Material 04SS* - Frame Depth Optional Features Sealed transitions (sleeve required) and sleeves Security Bars 6 in. (94mm) Blade Material 04SS* - Closure Spring Stainless Steel - Fusible Link 65 F (74 C) 22 F or 286 F (00 C) or (4 C) Mounting Vertical Horizontal * in gauges required by UL listing R-7 One piece retaining angles (POC) Transitions (B, B2, C, CO, CR, R) - * These dimension are furnished approximately 4 in. (6mm) undersize. See complete marking on product. UL 555 Classification R7 Model SSFD-50 meets the requirements for fire damper established by: National Fire Protection Association (NFPA Standards 80, 90A & 0) Underwriters Laboratories Standard 555 (Listing #R7) IBC International Building Codes New York City (MEA listing #260-9-M) California State Fire Marshall (Listing #225-98:02) Stainless Steel Closure Spring Fusible Link (replaceable) K side Horizontal Mount Installation All fire damper installations require the use of sleeves, angles and methods described in Greenheck Fire Damper Installation Instructions. Sleeves can be field fabricated or factory furnished as a complete damper/sleeve assembly. Installation instructions available at www.greenheck.com

Factory Sleeve Option SSFD-50 SSFD-50 Fire Dampers are available in factory furnished sleeves. Sleeves are 04 stainless steel and are available in 6 and 20 ga. (mm -.5mm) thicknesses and lengths up to 6 in. (94mm). K dimension specifies location of damper within the sleeve. Minimum is 4 in. (02mm), maximum is L less 4 in. (02mm), which allows for mounting angle installation and duct connection at each end of sleeve. If K dimension is not specified, the damper will be centered in the sleeve. Note: If using access doors, the doors should be installed on the K side of the damper. Sleeve Damper K Damper CL Damper Frame Location L Overall Sleeve Length When sealed option is selected, B transitions will need to be field sealed in the area where duct to sleeve connection is made. Type B with sleeve Type B corner profile

Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. If ordered with a factory sleeve, multi-section dampers are factory assembled ready for installation. If ordered without a factory sleeve, multi-section dampers require field assembly. The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Size Limitations Inches (mm) Vertical Vertical** Horizontal Horizontal** Type A Type B & B2 Minimum Maximum Minimum Maximum 4 x 4 (02 x 02) 4 x 4 (02 x 02) SSFD-50 Type A 48 X 48 (29 X 29) 96 X 48 or 20 x 40 (248 x 29 or 048 x 06) 6 x 6 (94 x 94) 4 X (02 X 76) 4 x (02 x 76) 48 X 42 (29 X 067) 96 x 42 or 20 x 5 (248 x 067 or 048 x 889) 6 x (94 x 787) Maximum Dimensions 2 - Limitations Maximum height is 48 in. (29mm) when width is 96 in. (248mm) or less. 48 in. (29mm) 48 in. (29mm) 48 in. (29mm) 96 in. (248mm) Sizing Data SSFD-50 Type B & B2 Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. If ordered with a factory sleeve, multi-section dampers are factory assembled ready for installation. If ordered without a factory sleeve, multi-section dampers require field assembly. Maximum Dimensions 2 - Limitations Maximum height is 42 in. (067mm) when width is 96 in. (248mm) or less /2 in. Varies /2 in. 42 in. (067mm) 42 in. (067mm) K dim. 48 in. (29mm) 96 in. (248mm) Sleeve Length Varies B2 side view * All multiple section dampers, with B transitions, will include a factory installed sleeve. All dampers with B2 transition will include a factory installed sleeve.

SSFD-50 Type B & B2 cont... 5 (27) 2 (584) 27 (686) 4 (02) 6 (52) 24 (60) 28 (7) 5 (27) 7 (78) 25 (65) 29 (77) 6 (52) 8 (20) 26 (660) 0 (762) 7 (78) 9 (229) 27 (686) (787) 8 (20) 0 (254) 28 (7) 2 (8) 9 (229) (279) 29 (77) (88) 0 (254) 2 (05) 0 (762) 4 (864) (279) (0) (787) 6 (94) Type B 2 (05) 4 (56) (0) 5 (8) 2 (8) 7 (940) (88) 8 (965) 4 (56) 6 (406) 4 (864) 9 (99) 5 (8) 8 (457) 5 (889) 40 (06) 6 (406) 9 (48) 6 (94) 4 (04) 7 (42) 20 (508) 7 (940) 42 (067) 8 (457) 2 (5) 8 (965) 44 (8) 9 (48) 22 (559) 20 (508) 2 (584) 9 (99) 45 (4) 40 (06) 46 (68) 2 (5) 24 (60) 4 (04) 47 (94) 22 (559) 26 (660) 42 (067) 48 (29) Sizing Data Type B2 * Dimensions in inches (mm). These dimensions are furnished 4 in. (6mm) undersize. (All H dimensions larger than 4 in. (092mm) are two sections high. The bottom section is a Type A and the top section is a Type B.) SSFD-50 Type CR, CO, C & R Dampers larger than maximum single section size are supplied in 2 or more sections of equal size. If ordered with a factory sleeve, multi-section dampers are factory assembled ready for installation. If ordered without a factory sleeve, multi-section dampers require field assembly. The following chart show minimum and maximum damper sizes. Dimensions are in inches (mm in parentheses). Inches (mm) Vertical Vertical** Horizontal Type CR Type CO & C Type R* Minimum Maximum Minimum Maximum Minimum Maximum 4 (04) 0 (762) X (76 X 76) X (76 X 76) 46 X 4 (68 X 04) 94 X 4 or 8 x 4 (288 x 04 or 2997 x 864) 4 x (864 x 787) 0 (762) 46 (68) 4 (864) * With 2 in. (50mm) offset. Sizes adjust with 0 offset and offset.

SSFD-50 Type CR, CO, C & R cont... D*+2 Type CR Maximum Dimensions T ype C T ype CO 4 in. (04mm) 46 in. (68mm) - Limitations 4 in. (04mm) 46 in. (68mm) Type CO D* +2 C, CO, CR transitions are positioned from bottom of sleeve +2 Type CR Type R Type C in. (76mm) min. 4 in. (04mm) in. (76mm) min. 46 in. (68mm) * All multiples section dampers, with transitions, will include a factory installed sleeve. or D* or D* 6 (52) 2 (584) 28 (7) 4 (02) 7 (78) 24 (60) 29 (77) 5 (27) 8 (20) 25 (65) 0 (762) 6 (52) 9 (229) 26 (660) (787) 7 (78) 0 (254) 27 (686) 2 (8) 8 (20) (279) 28 (7) (88) 9 (229) 2 (05) 29 (77) 4 (864) 0 (254) (0) 0 (762) 6 (94) (279) 4 (56) (787) 7 (940) 2 (05) 5 (8) 2 (8) 8 (965) (0) 6 (406) (88) 9 (99) 4 (56) 8 (457) 4 (864) 40 (06) 5 (8) 9 (48) 5 (889) 4 (04) 6 (406) 20 (508) 6 (94) 42 (067) 7 (42) 2 (5) 7 (940) 44 (8) 8 (457) 22 (559) 8 (965) 45 (4) 9 (48) 2 (584) 9 (99) 46 (68) 20 (508) 24 (60) 40 (06) 47 (94) 2 (5) 26 (660) 4 (04) 48 (29) 22 (559) 27 (686) - * Dimensions are inches (mm). These dimensions are furnished approximately 4 in. (6mm) undersize, except round and oval dimensions (D, H, W) are approximately 8 in. (mm) undersize. (All H dimensions larger than single section height are two sections high. Refer to chart.) Copyright 207 Greenheck Fan Corporation SSFD-50 Rev. 9 December 207