VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

Similar documents
D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

SINGLE DUCT AIR TERMINAL UNITS

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

SINGLE DUCT TERMINAL UNITS

LMHS BASIC UNIT NO CONTROLS

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

SINGLE DUCT AIR TERMINAL UNITS

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

C2-2. Table of Contents DUAL DUCT TERMINAL UNITS

FAN POWERED TERMINAL UNITS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

Variable Air Volume Dampers

IAQ. ROUND DUCT RETROFIT Model ARR

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

FAN POWERED TERMINAL UNITS

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

RETROFIT TERMINAL UNITS

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Variable Air Volume (VAV) Pressure Independent Control

FDCLP2 Constant Volume Series Flow, Low Profile

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

University of Delaware

I Fan Powered Terminal Unit

SECTION AIR TERMINAL UNITS

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

HOW TO SPECIFY SDV UNITS

single / dual duct terminals

Fan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow

catalog SDL Single-Duct, Low-Height, VAV Terminals

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

High Performance Fan Coils FCHG Genesis Series Horizontal

VAV TERMINAL UNITS. VVD VAV Diffusers

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

fan powered terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals

Laboratory Room Single Duct Supply Air Terminal

Laboratory Room Single Duct Supply Air Terminal

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

engineering guide TCS Series Fan-Powered, VAV Terminals

FCVC Series VERTICAL FAN COILS

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Technical information

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

Fan - Powered Terminal Unit Series Flow

catalog VFR Parallel Flow, Fan-Powered, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals

catalog SDR Single-Duct VAV Terminals

catalog VFL Parallel Fan-Powered, Low-Height, VAV Terminals

catalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals

catalog CFR Series Fan-Powered, VAV Terminals

STR Circular VAV Terminal Units

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

Fan-Powered Parallel

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

TSS Single-Duct VAV Terminals

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

PIM Pressure Independent Module

NV series. Induction VAV air volume control terminals

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

Laboratory Exhaust Air Terminal

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Air-Cooled Fluid Cooler

Dual Duct Variable Air Volume Terminal (Model TDS)

Rosemex Products 96 VENTILATION INDUCTION UNIT

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

ROUND DIFFUSERS G1. RM, RA Series Cone Diffusers. Introduction: RM, RA Series ROUND DIFFUSERS R M - R A S E R I E S

LINEAR SLOT DIFFUSERS PLENUMS

Smoke Dampers. Installation Instructions

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

FN Fan-Coil Units High-Performance, Horizontal

SPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

WAC Air Curtains Technical Guide

FPV, FDV Series Variable Volume Parallel Flow

SINGLE DUCT TERMINAL UNITS 3000 SERIES

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES Metal Industries, Inc.

Circular VAV and CAV air volume control terminals

EGG CRATE RETURN GRILLE

Fan-Powered Parallel

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

VAV TERMINAL BOXES TYPE: BA BT

VARYCONTROL VAV Dual Duct Terminal Boxes

Submittal PESVD

Mechanical mixing box MBM

Transcription:

TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also used in exhaust, non reheat, or other supply applications requiring a round to round duct connections. L This unit is designed to maintain optimum occupant comfort by varying the amount of cold air from the constant volume air handler and bypassing the excess cooling air into the ceiling plenum or return air duct. SVE This slide-in, retrofi t terminal unit is designed to convert constant volume or booster coil systems into modern, energy effi cient variable air volume systems with low installation costs. MS The rueger Measuring Station (MS) is designed to accurately measure airfl ow with a linear or four-quadrant multi-point differential pressure sensor in round duct applications. MODEL RVE Introduction & Unit Capacities... E-3 Product Description & Selection Guidelines... E-4 Retrofi t Procedures... E-5 RVE Unit Dimensional & Product Information... E-6 RVE Unit Performance Data... E-7 RVE Control Information... E-9 Engineering Specifi cation... E-10 MODEL L Introduction, Product Description, & Unit Capacities... E-11 L Unit with Pneumatic Controls Dimensional & Product Information... E-12 L Unit with Electric Controls Dimensional & Product Information... E-13 L Performance Data & Control Information... E-14 Engineering Specifi cation... E-15 MODEL SVE Introduction & Unit Capacities... E-16 Product Description & Selection Guidelines... E-17 SVE Application Information... E-18 SVE with Electronic Controls Dimensional & Product Information... E-19 SVE Sensor Signal Chart... E-20 SVE Performance Data... E-21 SVE Control Information... E-23 Engineering Specifi cation... E-24 MODEL MS Introduction, Product Description, Unit Capacities, & Dimensional Information... E-25 Engineering Specifi cation... E-26 E-2 Excellence in Air Distribution

L YPASS INTRODUCTION: L The Model L is designed to maintain optimum occupant comfort by varying the amount of cold air from the constant volume air handler and bypassing the excess cooling air back to the air handler. The L responds to the thermostat demand for cooling by varying the position of the unit damper, which in turn controls the amount of air entering a zone. During reduced loads, the damper position changes to defl ect supply air into the ceiling plenum or return air duct. In this way, the air handler operates at constant volume, while individual zones benefi t from increased control of comfort levels. Savings result from the elimination of variable speed drives for the air handling system fan(s). At reduced zone loads, cool primary air is returned to the air handler via the plenum or return air duct without experiencing zone heat gains. The lower return air temperature allows the air handler to operate more effi ciently. MODEL MODEL L - ypass Terminal Unit FEATURES L L PRODUCT DESCRIPTION CASING All L unit casing panels are constructed of 20 gage galvanized steel. RETROFIT/YPASS TERMINAL UNITS 20 Gage Galvanized Steel Casing Construction Single-blade Design Results in Fewer Parts and Leads to Increased Reliability and a Low Pressure Drop Manual Discharge Damper with No Spring Loaded Parts to Fail Side ypass Discharge for Easy Access to alancing Dampers Manual Inlet Air Damper to Control Air Volume Entering the Unit Low Pressure Drop; Requires Less Energy than Competing Models and a Lower Central Fan Motor Horsepower Requirement Insulated Case Provides Thermal And Acoustical Insulation Capacities as High as 4400 CFM to Increase Design Flexibility Choice of Pneumatic or Electric Controls on Top or ottom of Unit; Results in Flexibility to Fit Most uilding Control Packages L UNIT CAPACIES L, UNIT CAPACITIES Unit Size Max CFM [L/s] 6 500 [236] 8 900 [425] 10 1300 [614] 12 2000 [944] 14 2500 [1180] 16 3600 [1699] 18 4400 [2077] COLLARS All collars are round to accommodate standard fl ex duct sizes. An optional manual inlet damper is available. CONNECTIONS ypass and outlet connections are round. Optional multiple outlet is available. Optional manual dampers are available. INSULATION Casing insulation is 1/2 thick, 1 1/2 lb. dual density, fi berglass liner meeting UL 181 and NFPA 90A requirements. CONTROLS Pressure dependent pneumatic and electric control types are available. A no control unit is also available for fi eld mounting of controls. HANGER RACETS Optional hanger brackets are available. CONTROL TRANSFORMERS Electric controlled units are available with a factory supplied and wired optional 24 volt control transformer, mounted inside the control enclosure. LAELS Label information adhered to each unit includes model, size, airfl ow (CFM) and tagging information. PACAGING Multiple units are palletized. Each pallet of units is banded and stretch wrapped with cellophane. L Excellence in Air Distribution E-11

L YPASS L UNIT WITH PNEUMATIC CONTROLS DIMENSIONAL INFORMATION L UNIT WITH PNEUMATIC CONTROLS, PLAN & SIDE VIEWS ACTUATOR RETROFIT/YPASS TERMINAL UNITS 6 1/4" (159) C G SIDE VIEW F YPASS E D YPASS PLAN VIEW REVERSE ACTING AIR FLOW A AIR FLOW PLAN VIEW DIRECT ACTING L UNIT WITH PNEUMATIC CONTROLS, DIMENSIONAL DETAILS Unit Size Max CFM [L/s] A C D E F G 6 500 [236] 12 7/8" (327) 7 1/8" (182) 11 1/8" (283) 5 7/8" (149) 4 1/4" (108) 12 3/8" (314) 5 9/16" (141) 8 900 [425] 12 7/8" (327) 7 1/8" (182) 11 1/8" (283) 7 7/8" (200) 5 1/4" (133) 12 3/8" (314) 5 9/16" (141) 10 1300 [614] 14 7/8" (378) 8 1/8" (210) 13 1/8" (333) 9 7/8" (251) 6 1/4" (159) 14 3/8" (365) 6 9/16" (167) 12 2000 [944] 18 7/8" (479) 10 1/8" (257) 17 1/8" (435) 11 7/8" (302) 7 1/4" (184) 18 3/8" (467) 8 9/16" (217) 14 2500 [1180] 18 7/8" (479) 10 1/8" (257) 17 1/8" (435) 13 7/8" (352) 8 1/4" (210) 18 3/8" (467) 8 9/16" (217) 16 3600 [1699] 22 7/8" (581) 12 1/8" (308) 21 1/8" (537) 15 7/8" (403) 9 1/4" (235) 22 3/8" (568) 10 9/16" (268) 18 4400 [2077] 22 7/8" (581) 12 1/8" (308) 21 1/8" (537) 17 7/8" (454) 10 1/4" (260) 22 3/8" (568) 10 9/16" (268) Dimensions in ( ) are mm. D dimension is diameter of inlet, bypass, and outlet connections. Unit may be jobsite rotated 180 to have controls located on the bottom of the unit. L L UNIT WITH PNEUMATIC CONTROLS FEATURES & OPTIONS STANDARD FEATURES 20 Gage Galvanized Steel Casing Construction 1/2 Thick Dual Density Fiberglass Insulation Meeting NFPA 90A and UL 181 Safety Requirements ypass Discharge Collar Outlet Discharge Collar 5-10 psi Spring Range Actuator alancing Damper Operates on a 0-20 psi Thermostat Signal OPTIONAL FEATURES Manual Inlet Damper Manual ypass Damper Hanger rackets Thermostat E-12 Excellence in Air Distribution

L YPASS L UNIT WITH ELECTRIC CONTROLS DIMENSIONAL INFORMATION L UNIT WITH ELECTRIC CONTROLS, PLAN & SIDE VIEWS D F YPASS CONTROL ENCLOSURE G E RETROFIT/YPASS TERMINAL UNITS A C 4 1/4" (108) PLAN VIEW SIDE VIEW L UNIT WITH ELECTRIC CONTROLS, DIMENSIONAL DETAILS Unit Size Max CFM [L/s] A C D E F G 6 500 [236] 12 7/8" (327) 7 1/8" (182) 11 1/8" (283) 5 7/8" (149) 4 1/4" (108) 12 3/8" (314) 5 9/16" (141) 8 900 [425] 12 7/8" (327) 7 1/8" (182) 11 1/8" (283) 7 7/8" (200) 5 1/4" (133) 12 3/8" (314) 5 9/16" (141) 10 1300 [614] 14 7/8" (378) 8 1/8" (210) 13 1/8" (333) 9 7/8" (251) 6 1/4" (159) 14 3/8" (365) 6 9/16" (167) 12 2000 [944] 18 7/8" (479) 10 1/8" (257) 17 1/8" (435) 11 7/8" (302) 7 1/4" (184) 18 3/8" (467) 8 9/16" (217) 14 2500 [1180] 18 7/8" (479) 10 1/8" (257) 17 1/8" (435) 13 7/8" (352) 8 1/4" (210) 18 3/8" (467) 8 9/16" (217) 16 3600 [1699] 22 7/8" (581) 12 1/8" (308) 21 1/8" (537) 15 7/8" (403) 9 1/4" (235) 22 3/8" (568) 10 9/16" (268) 18 4400 [2077] 22 7/8" (581) 12 1/8" (308) 21 1/8" (537) 17 7/8" (454) 10 1/4" (260) 22 3/8" (568) 10 9/16" (268) Dimensions in ( ) are mm. D dimension is diameter of inlet, bypass, and outlet connections. Unit may be jobsite rotated 180 to have controls located on the bottom of the unit. L UNIT WITH ELECTRIC CONTROLS FEATURES & OPTIONS STANDARD FEATURES 20 Gage Galvanized Steel Casing Construction 1/2 Thick Dual Density Fiberglass Insulation Meeting NFPA 90A and UL 181 Safety Requirements ypass Collar Round Discharge to Room 24 VAC Actuator OPTIONAL FEATURES Manual Inlet Damper Manual ypass Damper alancing Damper Hanger brackets Thermostat 24 Volt Transformer L Excellence in Air Distribution E-13

L YPASS L PERFORMANCE DATA RETROFIT/YPASS TERMINAL UNITS L, DISCHARGE & RADIATED SOUND DATA Unit Size 6 8 10 12 14 16 18 Discharge Sound Radiated Sound 0.5" Ps 0.5" Ps Flow Rate Min Ps Octave and Lp Min Ps Octave and Lp Sound Power, Lw Sound Power, Lw CFM (L/s) "WG (Pa) 2 3 4 5 6 7 NC "WG (Pa) 2 3 4 5 6 7 NC 200 (94) 0.004 (1.0) 34 31 29 23 18 - - 0.069 (17.2) 48 41 37 37 30 20-300 (142) 0.009 (2.2) 46 42 39 35 30 23-0.155 (38.6) 59 52 49 49 43 34 23 400 (189) 0.016 (4.0) 54 51 47 43 39 33-0.276 (68.6) 67 60 57 57 52 44 32 500 (236) 0.025 (6.2) 61 57 53 49 45 41-0.431 (107.3) 73 67 63 64 59 51 39 300 (142) 0.003 (0.7) 31 28 25 20 16 - - 0.049 (12.2) 44 36 32 30 24 14-500 (236) 0.008 (2.0) 46 42 38 35 31 26-0.136 (33.8) 58 50 47 45 40 31 21 700 (330) 0.016 (4.0) 55 51 47 44 41 37-0.266 (66.3) 67 60 56 55 50 42 31 900 (425) 0.026 (6.6) 63 58 54 52 48 45-0.440 (109.6) 74 67 64 62 58 51 40 500 (236) 0.003 (0.8) 34 31 27 24 20 13-0.056 (13.9) 46 37 34 31 25 16-700 (330) 0.006 (1.5) 44 40 36 34 30 25-0.109 (27.2) 55 47 43 41 36 27-1000 (472) 0.013 (3.1) 54 50 46 44 41 37-0.223 (55.5) 65 57 54 51 47 39 28 1300 (614) 0.021 (5.3) 62 57 53 51 48 46-0.377 (93.8) 72 64 61 59 55 48 38 800 (378) 0.004 (1.0) 38 34 30 29 25 19-0.069 (17.1) 43 34 30 27 21 11-1200 (566) 0.009 (2.2) 50 45 41 40 37 34-0.155 (38.6) 57 49 45 42 38 29-1600 (755) 0.016 (4.0) 58 53 49 48 46 44-0.275 (68.5) 68 60 56 53 50 41 32 2000 (944) 0.025 (6.2) 65 59 55 54 52 52 21 0.430 (107.1) 76 68 65 61 59 51 42 1000 (472) 0.003 (0.8) 36 32 28 27 24 19-0.061 (15.1) 47 37 34 30 25 16-1500 (708) 0.008 (1.9) 48 43 39 39 36 33-0.136 (34.0) 58 49 46 41 38 29-2000 (944) 0.013 (3.3) 57 52 47 47 45 43-0.243 (60.4) 66 57 54 50 47 39 30 2500 (1180) 0.021 (5.2) 63 58 53 53 51 51-0.379 (94.3) 72 63 61 56 54 46 38 1200 (566) 0.003 (0.7) 35 31 26 26 23 18-0.049 (12.2) 45 35 32 26 22 12-1800 (849) 0.006 (1.6) 47 42 37 37 35 32-0.110 (27.4) 56 46 43 38 34 26-2700 (1274) 0.014 (3.6) 58 53 48 49 47 46-0.248 (61.7) 67 58 55 50 47 40 31 3600 (1699) 0.025 (6.3) 67 61 56 57 56 56 24 0.440 (109.6) 75 66 63 58 56 49 41 1600 (755) 0.003 (0.8) 37 33 28 28 26 21-0.054 (13.5) 38 36 33 27 23 14-2400 (1133) 0.007 (1.8) 49 44 39 40 38 35-0.122 (30.3) 53 48 45 39 36 28-3200 (1510) 0.013 (3.1) 57 52 47 48 46 46-0.217 (54.0) 64 56 53 47 45 37 27 4400 (2077) 0.024 (5.9) 66 60 55 57 56 57 23 0.410 (102.0) 76 65 62 57 55 48 43 All sound data is based on tests conducted in accordance with ARI 880-98. Ps is the difference in static pressure from inlet to discharge. Sound power levels are in d, re 10-12 watts. Discharge sound power is the sound emitted from the unit discharge. Radiated sound power is the sound emitted from the unit casing. NC application data is from ARI Standard 885-98 Appendix E, as a function of fl ow rate shown. Dash (-) indicates a NC less than 20. Minimum Ps for discharge sound has damper full open for 100% discharge. Minimum Ps for radiated sound has damper full closed for 100% bypass. See Engineering section for reductions and defi nitions. L CONTROL INFORMATION The following list of standard control arrangements are available with the L product offering. Each control approach offers pressure dependent, variable air volume, control to the zone. Control functions are identifi ed by the rueger control package designation. PNEUMATIC CONTROL ARRANGEMENTS Each control arrangement includes a factory supplied and installed pneumatic actuator. ELECTRIC CONTROL ARRANGEMENT Pressure dependent control package consists of a 24 volt electric actuator, optional 24 volt transformer and a control enclosure. 3500 - Temperature Responsive Control 1600 - Actuator Only; DA-NC Pressure Dependent Control 1601 - Actuator Only; RA-NO Pressure Dependent Control L Pneumatic Control Legend: DA - Direct Acting Thermostat RA - Reverse Acting Thermostat NO - Normally Open Damper Position to the Zone NC - Normally Closed Damper Position to the Zone E-14 Excellence in Air Distribution

L YPASS L SUGGESTED SPECIFICATION & CONFIGURATION 1. SERIES: (XXX) L - ypass Terminal Unit L UNIT Furnish and install rueger model L bypass terminal units of the sizes shown in the plans. 2. SENSOR TYPE: (X) 0 - No Sensor 3. UNIT STYLE: (X) 0 - Standard L 1 - L with Multiple Outlets 4. CODE: (XX) 06-6 08-8 10-10 12-12 14-14 16-16 18-18 5. CONTROL TYPE: (XXXX) 1600 - DA/NC Pneumatic 1601 - RA/NO Pneumatic 3500 - Electric 6. UNIT ACCESSORIES: (X) (X) (X) (X) 0 - None S - Hanger rackets C - Damper, Manual Inlet D - Damper, Manual - One for each multiple outlet E - Damper, Manual ypass G - 24-24 Vac Transformer H - 120-24 Vac Transformer J - 208-24 Vac Transformer - 240-24 Vac Transformer L - 277-24 Vac Transformer Unit casing shall be constructed of not less than 20 gage galvanized steel. All air inlet/outlet collars shall accommodate standard spiral and fl ex duct sizes. Controls must be capable of being located on top or bottom of unit casing. Unit casing shall be lined with 1/2 thick, 1 1/2 lb. dual density fi berglass insulation that meets UL 181 and NFPA 90A. The radiated and discharge attenuation factors for the specifi ed NC levels shall be based on attenuation factors from ARI Standard 885-98 Appendix E, which includes room absorption, environmental adjustment factor, duct insertion, end refl ection and duct branching. Label information shall be adhered to each unit to include model size, airfl ow (CFM), and tagging information. Terminals shall be tested in accordance with the latest ARI Standard 880. RETROFIT/YPASS TERMINAL UNITS SAMPLE CONFIGURATION: L - 0-0 - 08-1600 - S - 0-0 - 0 L Excellence in Air Distribution E-15