HVAC Rebates Rebate Application

Similar documents
HVAC Rebates Rebate Application

Motors & Drives Rebate Application

Premium Efficiency Motor Rebate Program (Retrofit Applications) Efficiency Requirements Page

Prescriptive Program Rebate Application

Cooling Efficiency 2017 Cooling Equipment Rebate Application

Prescriptive Program Rebate Application

2017 Commercial & Industrial Program K-12 Schools Program Rebate Application

InvestSmart Business Energy Upgrades HVAC Equipment Catalog 01/01/2017

Company name Date submitted. Billing address City State ZIP. Phone ( ) *

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

Prescriptive HVAC and Mechanical Equipment Application

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph:

COMMERCIAL HVAC REBATES

ENERGY EFFICIENCY FINANCIAL INCENTIVES HEATING, COOLING AND AIR-CONDITIONING MEASURES

OREGON SCHEDULE 115 COMMERCIAL AND INDUSTRIAL ENERGY EFFICIENCY RETROFIT INCENTIVES 20,000 SQUARE FEET OR LESS NO NEW SERVICE Page 1

Motor and Drive Efficiency Motor rebate application

Prescriptive Lighting Rebate Application

Motor and Drive Efficiency

2014 Motor Rebate Application

Motor and Drive Efficiency Motor Rebate Application

COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION

Motor and Drive Efficiency Constant Speed Motor Controller Rebate Application

2018 Program Manual CoolSaver

COMMERCIAL MOTORS & VARIABLE SPEED DRIVES REBATE APPLICATION

The Rebate Program can change without notice. CPS Energy reserved the right to discontinue the program at any time.

Motor and Drive Efficiency Drive rebate application

Prescriptive Rebate Program

Lighting Retrofit Incentive Application for Business Customers

Prescriptive Program Rebate Application

Prescriptive Program Rebate Application

Contents. 04 Overview. 05 Residential Energy Efficiency Program. 07 Heating Ventilation and Air Conditioning (HVAC) Systems

Lighting Retrofit Incentive Application for Business Customers

Lighting Retrofit Incentive Application for Business Customers

Heating, Ventilation and Air Conditioning Rebate Catalog Saving energy for a brighter future

Rebate Program Application

Lighting Retrofit Incentive Application for Business Customers

Company name Date submitted. Billing address City State ZIP

InvestSmart Business Energy Upgrades Custom Equipment Catalog 01/01/2017

LIGHTING INCENTIVES FOR BUSINESS CUSTOMERS

Lighting Efficiency Lighting Retrofit Rebate Application

INDUSTRIAL EQUIPMENT INCENTIVES FOR OREGON BUSINESS CUSTOMERS

Commercial & Industrial Retrofit 2017 Compressed Air Incentive

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

REBATE APPLICATION. 1. Rebate Applicant Information. 2. Dealer Information OKLAHOMA NATURAL GAS COMPRESSED NATURAL GAS (CNG)

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Sustainability Strategies

CARL MOYER MEMORIAL AIR QUALITY STANDARDS ATTAINMENT PROGRAM OFF-ROAD COMPRESSION-IGNITION (CI) APPLICATION

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

City Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.

InvestSmart Business Energy Upgrades Cool Roof and Window Film Equipment Catalog 01/01/2018

Appendix G - Danvers Electric

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

SINGLE PACKAGE HEAT PUMPS

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Small Business Lighting

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Lighting Efficiency Lighting Retrofit Rebate Application

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

R-22, 13 SEER 60 Hertz

Q7RE Series Single Packaged Heat Pump, Single Phase

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

CAC SERIES 12-1/2 Thru 20 Ton

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

Lighting Efficiency (For all customer peak demands) LIGHTING NEW CONSTRUCTION REBATE APPLICATION

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

Lighting Efficiency Lighting Retrofit Rebate Application

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

PACKAGE AIR CONDITIONERS

DIMENSION AND SELECTION GUIDE

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Lighting Efficiency Lighting Retrofit Rebate Application

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

Energy Efficiency Program Overview

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Ductless Mini-Splits

High Cap. (Btuh) HSPF COP

Lighting Efficiency Lighting Retrofit Rebate Application

APPENDIX A. Mechanical Equipment Sheets: York Chiller Marley Cooling Towers Calmac IceBank Storage Tanks Low Temp Air Cooling Coils

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Residential Packaged Geothermal Heat Pump

TECHNICAL SPECIFICATIONS

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Grocery and Convenience Stores October 11, 2012

TRAVERSE CITY LIGHT & POWER

Small Business Lighting

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity

Q7RE Series Single Packaged Heat Pump, Single Phase

AIR CONDITIONERS WA16 SERIES

Transcription:

Rebate Application Business Member Information Business Name Installation Address City, State, Zip Contact Name Email Phone Number Account Number Rebate Recipient Please Send Rebate to: Recipient Name Mailing Address City, State, Zip Contact Name Application Check List Rebate application with signature Itemized project invoices (labor & materials) Equipment specifications The undersigned does hereby certify that the undersigned is solely responsible for the accuracy of the information contained in this application. All rules of the program have been followed and the installation is complete. The undersigned acknowledges that nothing contained in the application imposes any liability on the cooperative for the work performed and information presented by the member, member's engineer, contractor, or vendor. The undersigned also authorized payment of incentive directly to the specified rebate recipient. Member Signature Date 952.492.2313 800.282.6832 125 MN Valley Electric Dr Jordan, MN 55352 Reviewed 11/2016

Rules & Information Warranty Information Rebate qualifications do not imply any representation or warranty of such equipment, design or installation by the cooperative. The cooperative shall not be responsible or liable for any personal injury or property damage caused by this equipment. The cooperative does not guarantee that a specific level of energy or cost savings will result from the implementation of energy conservation measures or the use of products funded under this program. In no event shall the cooperative be liable for any incidental or consequential damages. General Program Rules 1. Installation must be complete before application is submitted and funds are issued. 2. Members and vendors must submit itemized equipment invoices, rebate application, and manufacturer equipment specifications. To ensure that the equipment installed meets the cooperative's performance standards, these invoices must itemize labor charges, quantity and price of the equipment installed, as well as information regarding the manufacturer and model numbers for all equipment included in the rebate. 3. The cooperative reserves the right to conduct random inspections of installations. 4. Rebates must be applied for within 12 months of invoice date. 5. The member is responsible for checking with the cooperative to determine whether funding is available and to verify program parameters. 6. Project must comply with all program specific rules and qualifications. 7. The member is responsible for checking with the cooperative to determine funding availablility and to verify program parameters. 8. Qualifying members must apply for rebates no later than November 17, 2017. RTUs, Split Systems, ASHP, RTU Economizers Only new central air conditioning units and remote condensing unit retrofits qualify. Rebuilds do not qualify If the efficiency rating is in SEER and the application asks for ERR, EER = SEER x.855 Split Systems Both the condensing unit and the A-coil must be purchased to qualify for this rebate. Economizers Enthalpy controls are required to qualify for this rebate. CO₂ controls are optional but recommended. PTAC, Mini-Split, & Water-Source Heat Pumps Only new equipment units qualify. Rebuilds do not qualify. Ground-Source Heat Pump (Geothermal) Only new installations with a new loop fields qualify Replacement heat pumps with existing loop fields may qualify under the custom grant program.

Rules & Information (continued) Chillers, Cooling Towers, & Air Handler VAVs Chillers 1. No rebates will be provided for back-up systems. Back-up systems are defined as a separate chiller that is required only when a primary chiller fails. 2. The basis for the rebate efficiency level will be design conditions and chiller efficiency data as contained in the manufacturer specifications. 3. Use the Full-Load Efficiency for the base rebate on centrifugal chillers 150 tons. Cooling Towers 1. Rebate is paid per nominal tower ton. 2. Only new towers for electric chillers are eligible. 3. For purposes of determining rebate eligibility, design condensing water flow rate must be 3.0 gallons per minute per ton. 4. the design condensing water temperature to the chiller must be 84 F or less. 5. Cooling tower size must be larger than that which would be used to achieve a design condensing water temperature to the chiller of 85 F at wet bulb temperature of 78 F. 6. The brake horsepower per cell of tower fans must not increase as compared to the tower which would deliver 85 F design condensing water temperature. 7. The motors used in the cooling tower fans must meet the cooperative's NEMA Premium Efficient Motor program standards. See Premium Efficient Motor Rebate application. Air Handler Variable Air Volume (VAV) box 1. Rebate is paid per VAV box. One box serves each air handling unit zone. 2. The installation may be new or retrofit applications. Baseline VAV model compares air-handling zone which is being converted from constant volume. 3. The zone must be air conditioned by electric cooling equipment. 4. Only new VAV boxes (without fans) for retrofit applications qualify. 5. Supply and return fans (if return fans are used) serving the VAV zones must be equipped with Variable Frequency Drives (VFD). 6. Appropriate controls must be included to reduce fan energy usage. 7. The motors and/or VFDs for air handling fans must meet the cooperative's NEMA Premium Efficient Motor and VFD program standards. See Premium Efficient Motor Rebate and VFD Rebate applications. 8. The maximum rebate amount shall be the lesser of 50% of the project cost or $5,000.

RTU, Split System, ASHP, & Economizers Equipment Type Rooftop Units (RTU) 65,000 Btuh 65,000 - < 135,000 135,000 - < 240,000 240,000 - < 760,000 760,000 Split Systems 65,000 65,000 - < 135,000 135,000-250,000 Air Source Heat Pumps 65,000 65,000 - < 135,000 135,000-250,000 Condensers > 65,000 - < 135,000 135,000 RTU Economizers Minimum Qualifying Criteria Unit Tons EER ieer < 5.4 13.5 SEER 13.5 5.5-11.3 10.8 13.0 11.4-19.9 10.7 13.0 20.0-63.3 10.2 12.0 63.3 9.6 12.0 < 5.4 13.5 SEER 5.5-11.3 10.8 11.4-19.9 10.7 HSPF < 5.4 13 SEER 7.7 5.5-11.3 10.1 8.5 11.4-20 9.3 8.5 5.5-11.3 10.8 SEER 11.4 10.7 Enthalpy controlled Base Rebate $/ton $18.00 $200.00 $18.00 Incremental rebate, $/ton per 0.1 $13 / Ton $5.00 $18.00 $5.00 $5.00 $5.00 Roof top Units (RTU)/Split Systems Tonnage Efficiency Min Efficiency Quantity Rebate Rebate = ($18*tonnage)+($5*tonnage*(Eff - Min Eff)*10)*Qty Air Source Heat Pump (ASHP) Tonnage Efficiency Min Efficiency Quantity Rebate Rebate = ($200*tonnage)+($5*tonnage*(Eff - Min Eff)*10)*Qty RTU Economizers Manufacturer Tonnage Quantity Enthalpy* CO 2 ** Rebate yes no *Must be Enthalpy Controlled to qualify for Economizer rebate **CO 2 Controls optional The maximum rebate amount shall be the lesser Project Cost of 50% of the project cost or $5,000. Total Rebate 952.492.2313 800.282.6832 125 MN Valley Electric Dr Jordan, MN 55352

A/C Tune Up HVAC Contractor Company Name Address City, State Zip Phone Contact Name Equipment Information $25 per unit rebate Year # Units SEER or EER Tonnage 0 The maximum rebate amount shall be the lesser of 50% of the project cost or $5,000. Rebate 0.00 A/C Tune Up Requirements air conditioner must be in operating condition unit must be more than three years old and not had a tune-up in the last two years check points required for rebate clean condensor coil lube motor, if needed check refrigerant level test controls check refrigerant pressure blow out drain lines check indoor filter visual inspection of entire system check belt discuss proper O&M with owner 952.492.2313 125 MN Valley Electric Dr 800.282.6832 Jordan, MN 55352

Packaged Terminal Air Conditioners, Mini-Split, Water Source Heat Pump Minimum Qualifying Criteria Packaged Terminal Air Conditioners (PTAC) With electric resistance heating With heat pump heating* Mini-Split With electric resistance heating With heat pump heating* Water-Source Heat Pumps with C.O.P. 4.1 EER - Energy Efficiency Ratio (Btu/Watt) C.O.P. - Coefficient of Performance EER / C.O.P. 10.0 10.0 / 2.5 13.0 13.0 / 2.5 Base Rebate, $/ton $10.00 $200.00 $300.00 Incremental rebate, $/ton per 0.1 EER above base $1.75 $3.50 $0 12.0 $13.00 $1.30 PTAC w/ Resistance Heating PTAC Heat Pump w/ Resistance Heating Mini-Split A/C w/ Resistance Heating Mini-Split Heat Pump w/ Resistance Heating Water-Source Heat Pump The maximum rebate amount shall be the lesser Project Cost of 50% of the project cost or $5,000. Total Rebate 952.492.2313 125 MN Valley Electric Dr 800.282.6832 Jordan, MN 55352

Ground Source Heat Pump (Geothermal Heat Pump) Minimum Qualifying Criteria Equipment Type Minimum Efficiency Rebate $/ton Specific Rules Geothermal Heat Pumps EER C.O.P. ISO 13256-1 Closed Loop 13.4 3.1 (EWT @ 32 F Heat & 77 F Cooling) $400 ISO 13256-1 Open Loop 16.2 3.6 (EWT @ 50 F heat & 59 F Cooling) EER - Energy Efficiency Ratio (Btu/Watt) C.O.P. - Coefficient of Performance Ground Source Heat Pump Number EER COP # Units Tons/unit Rebate $0 $0 $0 Project Cost Total Rebate 0 The maximum rebate amount shall be the lesser of 50% of the project cost or $5,000. Required Information Building Square Footage Earth Loop Specifications Heat Output (BTUs) Contractor Architect Mechanical Engineer vertical horizontal slinky open 952.492.2313 125 MN Valley Electric Dr 800.282.6832 Jordan, MN 55352

Chillers, Cooling Tower & Air Handling VAVs Equipment Type Unit Tons Air Cooled Chillers Water Cooled Chillers < 150 Tons (centrifugal) 150 Tons (centrifugal) < 150 Tons (screw/scroll) 150 Tons (screw/scroll) Cooling Towers Air Handling Systems (VAV) FLV - Fully Loaded Value Minimum Qualifying Criteria Base Base Efficiency Rebate, $/ton FLV - EER IPLV - SEER 9.70 13.00 $10.00 FLV (kw/ton) 0.74 0.66 0.74 0.66 $20.00 $3 / nominal tower ton $170 / VAV Box Incremental rebate $/ton per.1 SEER/EER $2.00 Incremental rebate $ per 0.01 kw/ton $2.00 Air Cooled Chillers Manufacturer Model # of Units Tons/Unit Base Eff Eff Rebate Water Cooled Chillers < 150 Tons # of Units Tons/Unit Base FLV FLV Type Rebate Water Cooled Chillers 150 Tons # of Units Tons/Unit Base FLV FLV Type Rebate Cooling Tower centrifugal Manufacturer # of Units Tonnage screw/scroll Rebate Air Handling Systems (VAVs) Manufacturer # of Units CFM Rebate Project Cost Total Rebate The maximum rebate amount shall be the lesser of 50% of the project cost or $5,000. 952.492.2313 800.282.6832 125 MN Valley Electric Dr Jordan, MN 55352