Application for Energy and Fuels

Similar documents
Application for Energy and Fuels

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Chemical and Petrochemical Applications of Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

Prodigy ICP Application Note: # 1039

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

X-ray Analysis in Petrochemical and Polymer Industries: Challenges and Solutions

AVIO 200/500 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

lubricants analysis. complete solutions for your lab. Lubricants Analysis

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

CALIBRATION AND VERIFICATION STANDARDS

Elemental Analysis Advanced

GLASS EXPANSION NEWSLETTER

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Calibration & Verification Standards

CALIBRATION AND VERIFICATION STANDARDS

The Analysis of Biodiesel for Trace Metals and the Development of Certified Biodiesel Standards

Certificate of Accreditation

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

Petrochemical standards

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,

Determination of chlorine/chlorides using MWD- XRF

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Analysis of Sulfur and Trace Element Content in FAME

Metals Determination in Biodiesel (B100) by ICP-OES with Microwave Assisted Acid Digestion

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

S-PRO 3200 GC System for Sulfur Analysis

MINIMIZE WORKFLOW INTERRUPTIONS

Monitor Chlorine in Crude at Sub-ppm Levels

is a division of SCP SCIENCE Calibration and verification standards version 10.0 The benchmark for accurate measurements

DaimlerChrysler Alternative Particulate Measurement page 1/8

INTERPRETATION OF USED COOLANT ANALYSIS

Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

X-ray Essentials from XOS Proven Performance

breakthrough versatility

DCI-11 Corrosion Inhibitor for Gasoline-Alcohol fuels

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

Where oxygenates are used, ethers are preferred. Methanol is not permitted. (5)

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Determination of Sudan Dyes I IV in Curry Paste

The Role of Chemical Metrology in Transportation Industry

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

UL ALTERNATIVE FUELS & STANDARDS UPDATE

Non-exhaust contributions to PM levels in 5 EU cities. 39 th PMP Meeting 9-10 March 2016

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

TRACE ELEMENTS IN URINE. Event #3, 2012

Application Note. Abstract. Authors. Environmental Analysis

TSHR 7000 series TN-TS-TX analyzer

Thermal Exploitation of Wastes in Lignite Combustion Facilities

Certificate of Accreditation

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

The benchmark for accurate measurements SCP SCIENCE. Calibration and erification standards. version is a division of

DANI Transformer Oil Gas Analyzer

better analysis counts

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Pyrolytic Graphite Platforms

HPLC System S 600 Series

S 1125 HPLC Pump System

CHEMICAL CHARACTERIZATION OF PARTICULATE MATTER EMISSIONS FROM A CATALYZED TRAP EQUIPPED NATURAL GAS FUELED TRANSIT BUS

IFPAC 2003 Dr. Berthold Andres

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

TRACE ELEMENTS IN URINE

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Surface Preparation and Wet Cleaning for Germanium Surface

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

APPLICATION VAPODEST ALCOHOL IN BEVERAGES AND INTERMEDIATES

Water analysis, QC and more:

ACQUITY UPLC I-Class System with 2D Technology

4 A village survey: Mandari, Lakshmipur

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

On-Line NIR Analysis for Blending

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

ANNEX 2, REFERENCE FUELS

MEASURES TO IMPROVE AIR QUALITY IN THE SUBWAY SYSTEM

Internal Combustion Engines

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Metal and metalloid determination in biodiesel and bioethanol

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

TOTAL Cylinder Care ONBOARD IRON MEASUREMENT

The Impact of Oil Consumption Mechanisms on Diesel Exhaust Particle Size Distributions and Detailed Exhaust Chemical Composition

For Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others

HPLC SYSTEM S 500 SERIES

Transcription:

Application for Energy and Fuels Improved Throughput for Wear Metals Analysis by ICP-OES Using Next Generation Sample Introduction Technology Patrick Simmons, Doug Shrader & Phil Lowenstern Agilent Technologies 1

Typical Aqueous Application Conditions Details: Four-acid digest: HCl, HNO3, HClO4 and HF Calibration: stabilized with 30% v/v HCl Typical low flow plasma conditions High throughput with SVS-2 2

Organic Application Considerations The challenge: High vapour pressure from solvents Plasma instability Extinguished plasma Carbon build up on injector Poor precision and drift Down time - injector requires regular cleaning Nebulizer blockage Poor precision Down time - nebulizer needs cleaning 3

Organic Application Considerations The solution: Carbon build up Use radially viewed vertically oriented plasma Minimizes carbon build-up Exhaust positioned directly above plasma, efficiently extracts carbon byproducts Use oxygen addition into auxiliary gas flow to facilitate removal of carbon and reduce background Mandatory with axial ICP Nebulizer blockage Use nebulizer with large ID to reduce blockage from particulates e.g. SeaSpray, Slurry or V-groove nebulizer Use new OneNeb nebulizer Filter samples or allow to settle and sample from the top Conikal nebulizer produces finer aerosol 4

One Piece Torches Radial ICP Torches Designed specially for organic solvents Annealed for greater durability Choice of 0.8 and 1.4mm ID. injector 1.4 mm ID suitable for organic solvents of low to moderate volatility 0.8 mm ID suitable for highly volatile organic solvents 5

Nebulizers Sample particulates may block standard concentric nebulizers Dependent on sample composition e.g. wear metal particulates Poor precision Down time - nebulizer needs cleaning Quartz nebulizer Conikal, Seaspray and Slurry Faster washout V-groove nebulizer Made of PEEK polymer Minimizes particulate blockage Quartz nebulizer V-groove nebulizer 6

Spray Chambers Double-pass glass cyclonic spray chamber Double pass design Reduces solvent load Increased sensitivity Fast washout Suitable for low vapour organic solvents Cooled spray chamber Externally jacketed or Peltier cooled designs Can cool sample to -10 o C or lower Reduces solvent load Made of quartz Excellent for highly volatile organic solvents e.g. naphtha 7

Compatibility of Pump Tubing Pump Tubing Solvent PVC Viton PVC Solva Kerosene Gasoline Fuel Coolant N/A = unsatisfactory, = satisfactory, N/A = no data available 8

Organic Application Considerations The challenge: Various elements of interest May need to calibrate for 30 to 60 different elements Unknown concentration of analytes in samples Down time to perform multiple dilutions for the same sample Difficult interferences to overcome Poor accuracy 9

700 Series Optical Design Echelle Optical Design Full wavelength coverage Maximum flexibility for extended linear working range Elimination of spectral interferences All wavelengths captured in one reading Maximum speed and productivity Fewer optical components Excellent signal-to-noise Lowest detection limits Thermostatted to 35 o C Excellent long term stability Fast start-up, increasing sample throughput 10

11 Structured Background from Na 589nm in Oil - Diluted in white spirit FACT Corrected

Measuring Petroleum Products Successfully The solution: Linear dynamic range Use wavelength flexibility to extend the upper limit Still achieve best detection limits Structured backgrounds Radial ICP-OES Use patented Fast Automated Curvefitting Technique (FACT) Speed of analysis 725 simultaneous CCD system Fastest possible read out speed 12

Sample and Standard Preparation Sample Preparation Up to 1 in 10 dilution on a weight per volume basis Use suitable organic solvent e.g. xylene, kerosene, Shellsol Standard Preparation Multi-element organometallic standard (e.g. Conostan S-21) Select dilution ratio to achieve required concentration Add extra neutral base oil (No. 75) to ensure consistent viscosity 19

Typical Organic Instrument Conditions Plasma power 1.3-1.5kW Plasma gas flow 15 18 L/min Auxiliary gas flow 0.75 2.25 L/min (axial radial) Nebulizer gas flow (axial) Optimize (0.5 0.8 L/min) Nebulizer gas flow (radial) Set bullet to top of torch (0.5 0.8 L/min) AGM-1 setting 2-6 Stabilization delay Optimize via time scan Pump speed 5-10 rpm Uptake Rate < 1 ml/min Fast Pump Yes or No? 20

Wear Metals Analysis A High Throughput Application 15

Accuracy CRM Analysis 1084a Wear metals in lubricating oil Elements & Wavelength (nm) Results (ppm) CRM 1084a (ppm) % Recovery Ag 328.068 96.3 101.4 95 Al 167.019 105.6 104 102* Cr 267.716 96.9 98.3 99 Cu 327.395 99.1 100 99 Fe 238.204 100.6 98.9 102 Mg 279.553 100.6 99.5 101 Mo 202.032 96.6 100.3 96 Ni 231.604 99.5 99.7 100 Pb 220.353 107.7 101.1 107 S 181.972 2022 1700 119** Si 251.611 100.7 103 98* Sn 189.927 91.5 97.2 94 Ti 336.122 101.3 100.4 101 V 292.401 101.3 100.4 101 * Uncertified results ** Uncertified results, result was high because of kerosene contamination 16

Plasma Stability Concentration (ppm) 10 9 8 7 6 5 4 3 2 1 8 Hour Stability Run - NO Int. Std. Worksheet S21Stab7.vws 0 0:00 1:12 2:24 3:36 4:48 6:00 7:12 Time (Hrs:Min) Ag 328.068 Al 396.152 Ba 455.403 Ca 396.847 Cd 214.439 Cr 267.716 Cu 327.395 Fe 238.204 Mg 279.553 Mn 257.610 Mo 202.032 Na 588.995 Na 589.592 Ni 231.604 P 213.618 Pb 220.353 Si 251.611 Sn 189.927 Ti 336.122 V 292.401 Zn 213.857 90 % Limit 110 % Limit Eight hour stability run for elements in oil/kerosene - Conostan S21 17

Introduction In order to predict when equipment maintenance may be required or to prevent having to perform maintenance, lubricating oils in equipment are regularly analyzed to monitor changes in levels of wear-metals, and additive and contaminant elements. The analyst is mainly interested in trending changes over time, not exact values. So high sample throughput could be considered more important than accuracy, precision, long-term stability and repeatability/reproducibility. In this work, an Agilent 725 Series ICP-OES inductively coupled plasma optical emission spectrometer with Agilent SPS 3 Sample Preparation System and Agilent SVS 2 Switching Valve System was used. The SVS 2 improves efficiency by greatly reducing sample uptake and washout times. The typical ICP-OES sample analysis cycle time was halved (to 33 seconds per sample), significantly reducing operating costs, without compromising accuracy, precision, long-term stability and repeatability/reproducibility. 18

Measurement challenge Challenge While long-term stability and repeatability/reproducibility are important in wear-metal analysis, since analytical results are used only for trend analysis, accuracy becomes a less important factor and sample throughput is often the most critical consideration. Solution Using the Agilent SVS 2 Switching Valve System with an Agilent 725 Series radiallyviewed ICP-OES and Agilent SPS 3 Sample Preparation System more than halves the sample analysis cycle time of about 90 seconds without the SVS 2, to about 33 seconds per sample using the SVS 2, without compromising accuracy, precision or stability. 19

Experimental Instrumentation Instrument: Agilent 725 Series simultaneous ICP-OES with radially-viewed plasma. Accessories: Agilent SPS 3 Sample Preparation System; Agilent SVS 2 Switching Valve System. 725 ICP-OES Switching Valve System 2 Increase Productivity Higher sample throughput Decreased wear and tear on nebulizer/spraychamber/torch Lower operating cost through reduced argon use 20

SVS Productivity Packages How does it work? Comparison of the sample uptake, measurement and rinse profiles of 100 mg/l manganese without a SVS and the SVS 2. The data shows a dramatic increase in productivity while maintaining consistent data quality. 21

SVS 2 Switching Valve System Second Generation Switching Valve SVS 2 in Sample Load Position SVS 2 in Sample Inject Position Load Analyze 22

Experimental Instrumentation Agilent 725 Series ICP-OES instrument operating parameters Condition Setting Power 1.35 kw Plasma gas flow rate 15 L/min Auxiliary gas flow rate 2.25 L/min Spray chamber Glass cyclonic double-pass (Twister) Torch One-piece quartz radial (1.5 mm id injector) Transfer tube Glass Nebulizer Glass concentric (SeaSpray) Nebulizer flow rate 0.55 L/min Viewing height 9 mm Pump tubing Rinse/instrument: Gray/gray SolventFlex (1.30 mm id) Waste: Purple/black SolventFlex (2.29 mm id) Pump speed 12 rpm Total sample usage 2 ml Replicate read time 2 s Number of replicates 3 Sample uptake delay 0 s Stabilization time 12 s Rinse time 0 s Fast pump Off Background correction Fitted Note: An all-glass sample introduction system (part number 9910117900) was used. 23

Experimental Instrumentation Agilent SVS 2 Switching Valve System operating parameters Condition Loop uptake delay Uptake pump speed refill Uptake pump speed inject Sample loop size Time in sample Bubble inject time Setting 7 s 500 rpm 150 rpm 0.5 ml 6 s 6.9 s Note: The internal standard/diluent channel was not used. 24

Experimental Standard and sample preparation Calibration solutions of 0, 5, 10, 25 and 50 mg/l were prepared from Conostan S-21 + K certified standard, which contains 22 elements (Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V and Zn) at 500 mg/kg in oil. These calibration solutions were viscosity matched using Conostan Element Blank Oil (75 cst) and diluted with kerosene to give a total oil concentration of 10 % (w/v) in each solution. Duplicate 0.5 g portions of NIST SRM 1084a (Wear-Metals in Lubricating Oil) and 2 g of Element Base Oil were accurately weighed into 25 ml volumetric flasks and made up to volume with kerosene. A third 0.5 g portion was similarly prepared, spiked with S-21 + K standard. Duplicate 0.5 g portions of NIST SRM 1085b (Wear-Metals in Lubricating Oil) and 4.5 g of Element Base Oil were accurately weighed into 50 ml volumetric flasks and made up to volume with kerosene. 25

Experimental 3σ method detection limits (MDLs) & linearity correlation coefficients Element &wavelength MDL (mg/l) Ag 328.068 0.003 Al 308.215 0.018 B 249.678 0.011 Ba 493.408 0.002 Ca 422.673 0.008 Cd 228.802 0.005 Cr 205.560 0.010 Cu 327.395 0.007 Fe 259.940 0.004 K 766.491 0.081 Mg 285.213 0.006 Mn 260.568 0.004 Mo 204.598 0.015 Na 588.995 0.062 Ni 230.299 0.018 P 177.434 0.069 Pb 283.305 0.031 Si 251.611 0.101 Sn 283.998 0.128 Ti 334.941 0.002 V 292.401 0.003 Zn 213.857 0.015 Element &wavelength r 2 Ag 328.068 0.9998 Al 308.215 0.9998 B 249.678 0.9998 Ba 493.408 0.9996 Ca 422.673 0.9996 Cd 228.802 0.9999 Cr 205.560 0.9999 Cu 327.395 0.9997 Fe 259.940 0.9999 K 766.491 0.9996 Mg 285.213 0.9998 Mn 260.568 0.9998 Mo 204.598 0.9999 Na 588.995 0.9999 Ni 230.299 0.9999 P 177.434 0.9999 Pb 283.305 0.9997 Si 251.611 0.9999 Sn 283.998 0.9999 Ti 334.941 0.9997 V 292.401 0.9999 Zn 213.857 0.9999 26

Results NIST SRM 1084a Wear-metals in lubricating oil sample source NIST US Department of Commerce. Note: Values in parentheses () not certified (information only). Element & wavelength Certified (mg/kg) Found (mg/kg) Duplicate (mg/kg) Recovery (%) RPD dup. (%) Spike level (mg/l) Recovered (mg/l) Recovery (%) Ag 328.068 101.4 100.3 101.1 98.9 0.9 2.17 2.27 104.6 Al 308.215 (104) 99.7 100.4 95.9 0.7 2.17 2.27 104.3 Cr 205.560 98.3 104.3 105.5 106.1 1.2 2.17 2.27 104.3 Cu 327.395 100.0 102.7 103.6 102.7 0.8 2.17 2.27 104.5 Fe 259.940 98.9 105.2 105.4 106.4 0.2 2.17 2.25 103.5 Mg 285.213 99.5 102.5 102.9 103.0 0.4 2.17 2.28 104.9 Mo 204.598 100.3 106.2 106.3 105.9 0.1 2.17 2.28 104.9 Ni 230.299 99.7 106.2 107.0 106.5 0.7 2.17 2.28 104.9 Pb 283.305 101.1 103.1 105.7 102.0 2.5 2.17 2.30 105.9 Si 251.611 (103) 100.2 100.4 97.3 0.2 2.17 2.31 106.1 Sn 283.998 97.2 105.8 105.6 108.8 0.2 2.17 2.31 106.3 Ti 334.941 100.4 105.2 105.2 104.8 0.0 2.17 2.27 104.5 V 292.401 95.9 105.4 105.9 109.9 0.4 2.17 2.30 106.0 27

Results NIST SRM 1085b Wear-metals in lubricating oil sample source NIST US Department of Commerce. Note: Values in parentheses () not certified (information only), values in brackets {} not certified (reference only). Element & wavelength Certified (mg/kg) Found (mg/kg) Duplicate (mg/kg) Recovery (%) RPD dup. (%) Ag 328.068 304.6 307.0 315.9 100.8 2.9 Al 308.215 {300.4} 300.8 306.6 100.1 1.9 B 249.678 (300) 312.4 327.8 104.1 4.9 Ba 493.408 (314) 331.3 339.1 105.5 2.4 Ca 422.673 (298) 292.7 300.6 98.2 2.7 Cd 228.802 302.9 305.1 310.8 100.7 1.8 Cr 205.560 302.9 324.1 329.7 107.0 1.7 Cu 327.395 295.6 303.0 311.1 102.5 2.7 Fe 259.940 {301.2} 310.7 316.9 103.1 2.0 Mg 285.213 297.3 303.6 309.8 102.1 2.1 Mn 260.568 (289) 291.3 296.8 100.8 1.9 Mo 204.598 (296) 312.7 317.8 105.6 1.6 Na 588.995 305.2 299.4 309.7 98.1 3.5 Ni 230.299 295.9 315.5 319.7 106.6 1.3 P 177.434 {299.9} 317.0 317.4 105.7 0.1 Pb 283.305 297.7 308.7 313.2 103.7 1.5 Si 251.611 {300.2} 315.1 314.8 105.0 0.1 Sn 283.998 (294) 317.2 322.7 107.9 1.7 Ti 334.941 {301.1} 311.5 317.2 103.5 1.8 V 292.401 297.8 309.1 314.5 103.8 1.8 Zn 213.857 296.8 308.8 314.9 104.1 2.0 28

Results System stability 29

Experimental Washout / carryover & speed of analysis Washout/carryover Blank measurement Carryover (% of standard concentration) Ba 493.408 Ca 422.673 Fe 259.940 Cu 327.395 Mg 285.213 Zn 213.857 1 0.039 0.047 0.035 0.043 0.045 0.027 2 0.039 0.032 0.032 0.046 0.057 0.026 3 0.052 0.034 0.035 0.039 0.058 0.037 4 0.050 0.034 0.038 0.040 0.047 0.037 Speed of analysis Tube-to-tube analysis time averaged 33 seconds, equating to > 100 samples/hour. 30

SVS 2 Results Summary Were able cut the sample analysis cycle time from about 90 seconds to about 33 seconds per sample using the SVS 2, without compromising accuracy, precision or stability. Dead time is eliminated (sample uptake, stabilization and washout times) SVS 2 utilizes stacked switching valves, sample loop and high speed, positive displacement motor Constant solution flow improves plasma stability Sample never contacts pump tubing, inert sample path reduces sample carryover 31

Application Papers Available on the Agilent Technologies Web site (http://www.agilent.com) SI-A-1413 Determination of metals in oils by ICP-OES SI-A-1417 Determination of V, Ni and Fe in crude oils and bitumen with Sc as an internal standard SI-A-1420 Determination of wear metals in lubricating oil with Axial ICP SI-A-1422 Determination of Pb in Unleaded Gasoline with Axial ICP SI-A-1423 Determination of trace elements in a xylene solution of oil by ICP-AES with ultrasonic nebulization and membrane desolvation SI-A-1427 Multi-element analysis of fuel and lubricating oils by simultaneous ICP-OES SI-A-1431 Improving Throughput for Oils Analysis by ICP-OES PLUS: SI-A-1202, SI-A-1415 and SI-A-1418 32

Questions? THANK YOU 33 Next