Bourdon tube pressure switch with infinitely variable switching pressure differential

Similar documents
Bourdon tube pressure switch with infinitely variable switching pressure differential

RK / HED 3 OA3X/.. with plug-in connector HED 3 OA3X/..K6.. HED 3 OA3X/..KL..Q with plug-in connector. with plug-in connector

Throttle and throttle check valve

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

RK /02.03 HED 2 OA 2X/.. HED 2 OA 2X/..L.. HED 2 OA 2X/..KL.. HED 2 OA 2X/..K.. HED 2 OA 2X/..K6.. HED 2 1/6 RK /02.

Pressure reducing valve, pilot operated

2-way flow control valve

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure relief valve, pilot operated

Check valve, pilot operated

Supply pressure compensator, direct operated

Pressure reducing valve, direct operated, with pressure monitoring

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Hydro-electric pressure switch

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Double throttle check valve Type Z2FS 10

Meter-in pressure compensator, direct operated

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Twin throttle check valve

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Check valve, pilot operated

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure sequence valve, direct operated

Check valve cartridge Type M-SR

Proportional flow control valve, 2-way version

Proportional pressure relief valve, directly operated, rising characteristic curve

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Throttle and throttle check valve

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Pressure relief valve, pilot operated

Pressure relief valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Proportional flow control valve, with integrated pressure compensator

2-way flow control valve

Pressure sequence valve, direct operated

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Check valve, pilot operated

Pressure relief valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

2/2 directional seat valve, direct operated with solenoid actuation

Check valve, pilot operated

Pressure reducing valve, direct operated

2-way proportional throttle valve for block installation

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Check valve, pilot operated

Servo solenoid valves with on-board electronics (OBE)

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated

Throttle and throttle check valve

Pressure reducing valve, direct operated

2/2-way poppet valves with solenoid operation Type KSDER1

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional flow control valve, with inductive position transducer

Reservoir oil filler/breather

Pressure reducing valve, pilot operated Type DR

3/2 and 4/2 directional poppet valve with solenoid actuation

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated

Electronic pressure switch with two switching outputs

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Block mounting filter, for lateral flange-mounting

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Hydraulic inch power brake valve LT 31

Block mounting filter, for lateral flange-mounting

Return line filter for direct tank mounting Type ABZFR

Proportional pressure reducing valve, pilot operated

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Directional servo-valve of 4-way design

Proportional pressure reducing valve, 3-way variant, pilot operated

Inline filter with filter element according to DIN 24550

Block mounting filter, for sandwich plate mounting

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Block mounting filter, for vertical flange-mounting

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Pressure relief valve, directly operated

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Transcription:

Bourdon tube pressure switch with infinitely variable switching pressure differential RE 00/06. Replaces: 0.0 /8 Type HED Component series X Maximum operating pressure 00 bar CCC TB0008 Table of contents Contents Page Features Ordering code Plug-in connectors Function, section, symbol Technical data Unit dimensions, 6 Pin assignment 7 Circuit examples 7 Features Indicator lamp, optional Electrical connection Cable gland Plug-in connector Lockable cap, optional

/8 Bosch Rexroth AG Hydraulics HED RE 00/06. Ordering code HED OA X * Bourdon tube pressure switch Component series 0 to 9 = X (0 to 9: unchanged installation and connection dimensions) Pressure range max. bar = Pressure range max. 6 bar = 6 Pressure range max. 00 bar = 00 Pressure range max. 00 bar = 00 Pressure range max. 00 bar = 00 ) Plug-in connectors, separate order, see below. No code = Q = No code = L = L0 = L0 = No code = K ) = K6 ) = Further details in clear text Without lockable cap With lockable cap Without Indicator lamp Indicator lamp for V (0 V to V) Indicator lamp for 0 V (90 V to 0 V) Indicator lamp for 0 V (80 V to 0 V) Electrical connection Cable gland Plug-in connection -pin + PE Plug-in connection 6-pin + PE Plug-in connectors Plug-in connector -pin + PE Plug-in connector 6-pin + PE; EN 70-80 Pg Pg Colour: red Colour: grey for connection K Material no. R900008 for connection K6 Material no. R9000080

RE 00/06. HED Hydraulics Bosch Rexroth AG /8 Function, section, symbol Hydro-electric pressure switches of type HED are Bourdon tube pressure switches. They basically consist of housing (), Bourdon tube () with actuating lever (), micro-switch () and two adjustment elements (). Pressure switches assume the task of opening or closing an electrical circuit in dependence upon pressure. The pressure to be monitored acts on Bourdon tube (). Bourdon tube () bends, and actuating lever () fixed to it transmits the movement of Bourdon tube () to micro-switch (). This causes the electrical circuit to open or close depending on the circuit setup. When the pressure continues to increase, Bourdon tube () bends further, which causes actuating lever () to operate the second micro-switch and to open or close the electrical circuit depending on the circuit set-up. Adjustment of the switching pressure The two switching pressures required, which are determined by the position of the micro-switches, can be adjusted separately and independently of each other on two adjustment elements (). When a switching relay is used, the switching pressure differential is infinitely variable. Symbols Without Indicator lamp With Indicator lamp P P P

/8 Bosch Rexroth AG Hydraulics HED RE 00/06. Technical data (for applications outside these parameters, please consult us!) General Weight kg 0.8 Installation position Optional Ambient temperature range C 0 to +0 (NBR seals) Conformity CCC EN 608-:99, IEC 6097-- Hydraulic Pressure range 6 00 00 00 Maximum operating pressure (briefly) bar 0 70 0 0 0 Switching pressure differential ) bar to. to 9 to 9 0 to 90 to 80 Falling pressure minimum bar. 6 0 0 maximum bar 6 00 00 00 Increasing pressure minimum bar. 8 0 maximum bar 7 67 0 0 Hydraulic fluid Mineral oil (HL, HLP) to DIN ; fast bio-degradable hydraulic fluids to VDMA 68 (see also data sheet 90); HETG (rape seed oil); other hydraulic fluids on enquiry Hydraulic fluid temperature range C 0 to +80 (NBR seals) Viscosity range mm /s 0 to 800 Max. permissible degree of contamination of the hydraulic fluid - cleanliness class to ISO 06 (c) Class 0/8/ ) Electrical Contact assignment AC voltage V AC 0 V; A DC voltage V DC 0 V; A In the case of DC voltage with inductive load, provide a spark suppressor to prolong the service life. Maximum switching frequency /h 800 Switching accuracy (repeatability) aprox. ± % of set pressure Long-term drift of switching point 0 000 load cycles approx. + % of max. set pressure 00 000 load cycles ) approx. +0 % of max. set pressure Type of protection to EN 609 IP 6 with plug-in connector mounted and locked Electrical connection Cable gland Pg Plug-in connector Pg Maximum cable Cable gland mm. cross-section Plug-in connector mm. ) Constant over the entire adjustment range ) The cleanliness classes specified for components must be adhered to in hydraulic systems. Effective filtration prevents malfunction and, at the same time, prolongs the service life of components. For the selection of filters, see www.boschrexroth.com/filter. ) It is not possible to make any statements for long-term drift above 00 000 load cycles. Notes: Use of the pressure switch Bourdon tube pressure switches may only exposed to dampened mechanical vibration (mounting with rubber buffers). To compensate for pump pulsation, we recommend that the pressure switch be connected by means of minimess hoses (DN approx. mm, min. length meter). Switching pressure differential To ensure the reliability of the switching signal, the actual pressure differential obtained must be greater than the existing switching pressure differential of the pressure switch. Long-term drift of switching points Because the set switching point may change over the lifetime, the pressure switch is not suitable for use in safety applications.

RE 00/06. HED Hydraulics Bosch Rexroth AG /8 Unit dimensions (dimensions in mm), 9 90 7 8 8 7 06 90 8 Pg 7 7 0, 6 6 0 9. 8 7 G/;., 0,,, 66 09. Set screw, self-locking, for switch minimum switching pressure. Set screw, self-locking, for switch maximum switching pressure Pressure port P Nameplate Lockable cap, optional (spare key, material no. R900006980, separate order) Space required to remove key 6 fixing holes 7 Electrical connection via cable gland Pg

6/8 Bosch Rexroth AG Hydraulics HED RE 00/06. Unit dimensions: Electrical connection (dimensions in mm) HED OAX/.K.. HED OAX/.K6.. Pg 66 7 ca. Pg 6 7 67 ca. 0 8,, HED OAX/.KL.. 66 6 7 Pg 7 ca. HED OAX/.K6L.. Pg 67 ca. 0 8,, HED OAX/.L.. Pg Indicator lamp Can be rotated in 0 increments around the plug-in axis Dimension to remove plug-in connector Plug-in connector, red Plug-in connector, grey 0

RE 00/06. HED Hydraulics Bosch Rexroth AG 7/8 Pin assignment Connection K PE Connection K with indicator lamp L... PE Connection K6 PE 6 Connection K6 with indicator lamp L... PE 6 Connect indicator lamp according to the desired circuit Circuit examples min. ) ) max. R(P) min. ) ) max. R(P) ) ) S(N) ) ) S(N) Differential circuit with N/O contact ( x HED ) Differential circuit with N/C contact ( x HED ) ) Pressure switch ) Pressure switch ) Indicator lamp ) Operating relay

8/8 Bosch Rexroth AG Hydraulics HED RE 00/06. Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +9 (0) 9 / 8-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.