The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

Similar documents
The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

Accumed BAC-178 Professional Fuel Cell Sensor Alcohol Tester

Breath Alcohol Tester

TABLE OF CONTENTS. Introduction

DIGITAL DISPLAY ALCOHOL BREATH TESTER

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Breath Alcohol Tester

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

BrAC Audit Lock-1 Instruction User Manual

The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

ACE II Basic. Operating manual.

AMS 2000 USER GUIDE GUARDIAN INTERLOCK RESPONSIBLE DRIVER PROGRAM. GuardianInterlock.com Ensuring Safety For Over 30 Years.

Andatech PRODIGY USER MANUAL

Flue Gas Analyzer IMR 1100F

PROBLEMS?

Operators Manual. Monitech Interlock Systems QuicTest User Manual Rev A

Operators Manual. Monitech Ignition Interlock Systems QuicTest TM User Manual Rev

FAQs for the Draeger Interlock 7000

DIGITAL TORQUE GAUGE MODEL BTGE-G

Guardian AMS2000 Operating Guide KS

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Grain Moisture Meter. Operators manual

D Dräger Interlock 7000 User Guide Victoria s Alcohol Interlock Program

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

ECscan20 Pocket Conductivity Tester Instruction Manual

Dr. M WARNING: CAUTION: 3 IN 1 FAMILY THERMOMETER THIS PRODUCT IS NOT A TOY. ADULT SUPERVISION IS REQUIRED. STORE AWAY FROM CHILD S REACH.

2/10/2016. Why Ignition Interlock? The Nuts & Bolts of Ignition Interlock. Separating Drinking from Driving

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Installation Manual for 1st 228-LC Breath Alcohol Ignition Interlock Devices

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

ALCOSENSE FR9000 INTERLOCK USER GUIDE/MANUAL

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

DLS-TP400 USER S MANUAL

Care and use guide. Contents. page

Dräger INTERLOCK XT User Manual Version 3.2

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

501 CMR: EXECUTIVE OFFICE OF PUBLIC SAFETY

ORPscan20 Pocket ORP Tester Instruction Manual

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9

Quantumfire QF cue Wireless Remote Firing System

Marine Exhaust Temperature Alarm. COMPONENTS

North Carolina User Manual Monitech Interlock Systems 215 Southport Drive Suite 400 Morrisville, NC local toll free

Marine Exhaust Temperature Alarm. COMPONENTS

APPENDIX B ALCOHOL SAMPLE COLLECTION AND TESTING PROCEDURES

Powered Air Purifying Respirator (PAPR) System

GSL Electronics Modified Sine Wave Power Inverters

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

IAQ-CALC TM Indoor Air Quality Meter

Errors in Current Alcohol Breath Analysis

501 CMR: EXECUTIVE OFFICE OF PUBLIC SAFETY

BlueFin User's Manual. Version 1.1

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Fibertec 8000 Fully automated Crude and Detergent Fibre analysis

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

PN# A,13-316A,13-317A, , , & TireGard

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

Owner s Manual Q3 Innovations, LLC v070108

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

c-go 24V/6A 24V/8A 24V/12A

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

PHscan10S Pocket ph Tester Instruction Manual

Digital Formaldehyde Meter

500Z Owner's Manual & Troubleshooting

Instruction Manual. IT-1 Infrared Thermometer

ETHOS Digital Sound Level Meter. Operating Manual

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

ROADSTART Units INSTRUCTIONS FOR: MODEL No's: RS121, RS122, RS125

Bante220 Portable ph Meter Instruction Manual

OCS Series. High Resolution Digital Crane Scale. User Guide

Dräger Interlock 7000 Instructions for Use Version 1.4

GRAVITY MEASUREMENT, INC.

User's Guide. CO 2 Meter. Model CO250

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

DIAMOND & WHITE SAPPHIRE TESTER

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

EAGL 1-Touch Laser Level

DIGITAL TORQUE WRENCH. Useful Instructions

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

MoistureMatch A next generation grain tester

INSTRUCTION MANUAL. Handy Polaris

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Semi-automatic Thermal Sealer

TDSscan10M Pocket TDS Tester Instruction Manual

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

MPPT SOLAR CONTROLLER FOR MODELS: 20A baterai 12V 24V

PH60 Series Premium ph Testers

Alcohol Interlock Program. Participant Guide

IAQ-CALC TM Indoor Air Quality Meter

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

Instruction Manual PROBLEMS?

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

ORDERING INFORMATION SPECIFICATIONS APPLICATION

OVERVIEW OF CONTROLS

PAPRV. Powered Air Purifying Respirator (PAPR) System. Please read these instructions carefully before using this unit. affect your health and safety.

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Transcription:

Measurement The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology. Please wash your mouth with water and abstain from smoking or drinking alcohol for at least 10 minutes before use. Power Supply Slide back the battery cover on the back of the device. Install 3 x 1.5V alkaline batteries (AAA) into the battery compartment. When battery power is not sufficient enough for testing, the battery indicator will flash. In this circumstance, please remove the drained batteries and replace with a fresh set of batteries immediately.

Parts Wait Ready Blood alcohol content above alert level Battery Indication Blow Unit No Driving

Note: with the LCD screen displaying the test result, as shown above, the user may press the 'ON' key to recall the last test result record.

Important Notes When the device records its maximum available tests, '500' and 'MAX TEST' will display and flash on the LCD. Users will need to refresh/calibrate the device so that the device can take a test with correct result reading. 'MAX TEST' will display and blink each time when you enter into the test mode of the device. To continue testing, you will have to wait for 5 seconds. To discontinue the display of MAX TEST, you will need to visit an authorized service center and calibrate your equipment. When unused for a long time or at a low temperature, the machine will take longer to prime itself / warm up. After 5 consecutive tests, allow the device to rest for 5 minutes. Please store in a dry environment at room temperature. Avoid extreme heat or long-term sun exposure. When the battery indicator flashes, please replace the batteries. If the difference between two successive readings is >0.1%, the user should test again. Do NOT block the outlet during sampling. When Err flashes, press 'OK' to restart the test. The device will revert to ALCO mode once Err flashes for 5 seconds.

Specifications Alcohol Sensor: Fuel cell Sensor Blowing time: 5 to 7 seconds Breath power: 10L/min Display Range: 0.0~400.0mg/100ml or 0.00~4.00 BAC; or 0.000~0.400% BAC or 0.000mg/L~2.0mg/L (if to mg/l convection factor is 2.0) Accuracy: +/- 0.006 BAC at 0.05 BAC Use temperature: +5 C to +45 C / Storage temperature: 0 C to +55 C Test counter with recalibration alarm Calibration: Every 500 tests. Breath pressure and interruption detection Power Input: 3 x AAA alkaline battery. Display: Digital LCD display with bi-colour backlighting.

Auto Power Off: approximately 30 seconds Dimension: 125 x 62 x 18 mm. Weight: 80g. Agency Approval: CE Accessories: 2 mouth pieces. Precautions Your blood alcohol content (BAC) may change within minutes Do not use this device to determine whether or not it is safe for you to drive. You cannot use these test results in Court. Your safest bet is not to mix drinking with driving at all. Avoid Binge drinking; Remain under the ALERT LEVEL, regardless of whether you're driving. Do not share with friends. This unit is designed for personal use, with accuracy and hygienic considerations taken into account. This unit may require a few minutes of standby between measurements. Store according to specifications. Avoid long term sun exposure and humidity. Handle with care, as a fragile item.

How often should I re-calibrate the tester? The tester can remain accurate for 500 uses. We recommend recalibration after this many measurements to ensure maximum accuracy. Please contact an Authorized service center. NB* It is important to observe the recommended 20 minute pause without consuming any alcohol, cigarettes or anything else before testing. Failure to do this can shorten the life of the sensor. In such cases, the sensor can be permanently damaged or may require more frequent calibration. This user manual should be read carefully for information on caring for the unit sensor. Many factors (e.g. environment gas residue, smoke & various smells in the human mouth, etc ) may affect the BAC level, so the readings are For Reference Only. Kogan does not accept any liability arising from the use of the unit. Don t drink before you drive!