I-BFV.KIT Butterfly Valve Gear Operator Replacement

Similar documents
FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Installation, Operation and Maintenance Manual

Technical Data. Sizes 2 12 Inch (DN50 DN300)

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

PCVS Series Control Valve Supervisory Switch

Worldwide Contacts. Technical Data

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Materials. Contact Ratings. Conduit Entrances

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Potter Electric Signal Company, LLC St. Louis, MO Tech Support: / Customer Service:

Installation& Maintenance Instructions

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

OSYSU Series Outside Screw and Yoke Valve Supervisory Switch

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Quarter Master Series 94 Actuator

Electrical Options Booklet. Table of Contents

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Locktite Manual Reset Gas Shut-Off Valves

Surepowr Series 100 Installation Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Installation Instructions

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

I-799/79V Coil Components

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Model RM-1 Riser Manifold Commercial and Residential General Description

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

Installation and Operating Manual

TM-VE436MC.KIT. VE436MC Roll Grooving Tool WARNING EXPLODED VIEW OF SLIDE UPGRADE KIT SLIDE UPGRADE KIT INSTRUCTIONS

SAX Electronic Valve Actuator

Electric Actuator Instructions

IOM Manual. IOM Manual. Series 76/77.

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

E.S.P. Embedded Sensing Probes for Motor Brushes

M100F Incremental Motor Actuator R81F Interface Board

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

AMERICAN AVK COMPANY AVK SERIES 34 WALL MOUNTED & TELESCOPIC POST INDICATORS, UL LISTED, FM APPROVED FIELD MAINTENANCE AND INSTRUCTION MANUAL

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

A5000GEC-24VDC ZERO SPEED SWITCH

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

FOR SIT-STAND WORKSTATION

Series 41 and 81 Modutrol IV Motors

Quarter Master Chief Series 92 Actuator

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Surepowr Series Sure 150

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 34 WALL MOUNTED & TELESCOPIC POST INDICATORS, UL LISTED, FM APPROVED FIELD MAINTENANCE AND INSTRUCTION MANUAL

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

Small Motorized Actuator

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

BL7000 SYSTEM OPERATING MANUAL

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

PARTS LIST CONTROL PANEL COMPONENTS

VA-4233-GGx Series Electric Valve Actuators

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

Eclipse AutoTite Automatic Gas Shut-Off Valves

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

VA-4233-AGx Series Electric Valve Actuators

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

VG7000 Valve Linkage for M100 Series Motor Actuators

Powers TM Controls EA 338 Electronic Actuator

Model 116 DPI Switch Installation and Operating Instructions

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

( Versions Available)

BMW F8x M3 & M4 Valvetronic Exhaust System

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Model DFR 070/156/220 Rotary Actuator

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

SAFE & SECURE ACTUATOR PRODUCT MANUAL

HQ-006 ¼ Turn Actuator

4000 SYSTEM OPERATING MANUAL

Installation and Service Instructions for Self Adjust Brakes 82,000 Series

V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

V Series. 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS With Isolated Control/Position Feedback Board Installed (Option U )

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U )

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

Transcription:

SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in serious personal injury and/or property damage. The following instructions cover the procedures required for removing and replacing a gear operator on Series 5, 05,, and 0C Butterfly. In addition, this sheet covers the procedures for adjusting the gear operator s travel limit stops for 10-12-inch/23.0-323.9-mm sizes. Always read all instructions and labels, supplied with the product, for proper installation, operation, and maintenance instructions. EXPLODED VIEW OF GEAR OPERATOR ASSEMBLY 9 1 8 1 1 2 2 2 5 Valve Body Mounting Flange 10 3 4 5 3 4 5 Valve Body Mounting Flange Valve Body Mounting Flange 2-4-inch/0.3-114.3-mm Valve Sizes (Series 5 Shown) 5-8-inch/141.3-219.1-mm Valve Sizes (Series 5 Shown) 10-12-inch/23.0-323.9-mm Valve Sizes (Series 5 Shown) Item Description 2-4-inch/ 0.3-114.3-mm 5-8-inch/ 141.3-219.1-mm 10-12-inch/ 23.0-323.9-mm 1 Actuator Flag 1 1 1 2 Gear Operator 1 1 1 3 O-Ring 1 1 0 4 O-Ring 1 1 0 5 Self-Tapping Torx Screw 1 1 1 Item Description 2-4-inch/ 0.3-114.3-mm 5-8-inch/ 141.3-219.1-mm 10-12-inch/ 23.0-323.9-mm Lock Washer 2 4 4 Hex-Head Screw 2 4 4 8 Coiled Pin * * 1 9 Handwheel * * 1 10 Key # * * 1 * Handwheels for 2-8-inch/0.3-219.1-mm valve sizes come pre-assembled to the gear operator. For 10-12-inch/23.0-323.9-mm valve sizes, the gear operator is shipped without the handwheel installed. Follow the instructions on the following page to install the handwheel to the gear operator. O-ring replacement sizes (SAE AS-58) are as follows: -mm ID x 1.5 mm for 2-3-inch/0.3-88.9-mm valve sizes, 011 for the 4-inch/114.3-mm valve size, and 013 for 5-8-inch/141.3-219.1-mm valve sizes. O-ring replacement size (SAE AS-58) for all valve sizes is 32. # Key is 30 Brass, 1/4-inch square x 2 1/4 inches long _1

SERIES 5, 05,, and 0C GEAR OPERATOR REPLACEMENT In the event that a gear operator fails, complete replacement would be required. Refer to the drawings on the previous page for the parts breakdown. The gear operator replacement procedure can be performed without removing the valve from the piping system. FLOW MUST BE SHUT OFF OR DIVERTED to prevent flow from passing through the valve during removal of the gear operator. CAUTION Use ONLY Victaulic replacement parts. Before removing the gear operator, note the current orientation of the gear operator on the valve body mounting flange. The new gear operator must be installed on the valve body mounting flange in the same orientation. Failure to follow these instructions may cause in improper valve operation, resulting in property damage. 1. De-energize the electrical system and disconnect the wiring before attempting to replace the gear operator. 3. Remove the hex-head screws (Item ) and lock washers (Item ) from the underside of the gear operator (Item 2), where the gear operator mounts to the valve body mounting flange. NOTE: For 2-4-inch/0.3-114.3-mm sizes, only two hex-head screws mount the gear operator to the valve body mounting flange. 2. Remove the self-tapping torx screw (Item 5) from the actuator flag (Item 1). Remove the actuator flag (Item 1). 4. Lift the gear operator (Item 2) straight up off the valve body mounting flange. Use caution when removing the gear operator in order to prevent damage to the stem. NOTE: For 10-12-inch/23.0-323.9-mm valve sizes, be careful not to lose the key (Item 10) installed in the stem. This key is required for proper installation of the gear operator in later steps. Inspect the key for signs of damage. If necessary, replace the key with a new, VIctaulic-supplied key of the same type and size (30 Brass, 1/4-inch square x 2 1/4 inches long). _2

SERIES 5, 05,, and 0C 5. Inspect the o-ring between the gearbox and valve body mounting flange (Item 3) and the o-ring around the valve stem (Item 4) for signs of damage. Replace the o-rings, if necessary. NOTE: The 10-12-inch/23.0-323.9-mm valve sizes do not contain the o-rings shown above. Coiled Pin Gear Operator s Input Shaft. For 10-12-inch/23.0-323.9-mm valve sizes: The gear operator is shipped without the handwheel (Item 9) installed. Install the handwheel onto the gear operator s input shaft. Align the hole in the handwheel s hub with the input shaft s hole. Drive the coiled pin (Item 8) through the handwheel and input shaft. 8. Use the hex-head screws (Item ) and lock washers (Item ), removed in Step 3, to secure the new gear operator to the valve body mounting flange. Tighten the hex-head screws until the lock washers are fully compressed. Gear Operator s Cam. Install the replacement gear operator in the exact orientation as the one removed from the valve body mounting flange. Turn the handwheel to align the new gear operator s cam to the valve stem. Install the gear operator so that the rectangular valve stem engages the gear operator s cam. NOTE: The gear operator engages with the valve stem only one way and should not be forced. Once engaged, turn the handwheel until the gear operator s mounting holes align with the holes in the valve body mounting flange. NOTE: The 10-12-inch/23.0-323.9-mm valve sizes do not contain a cam. 9. Re-install the actuator flag onto the valve stem with the selftapping torx screw removed in Step 2. 10. Operate the valve with the handwheel to ensure that the valve opens and closes fully and that the actuator stem and disc are in the same orientation. 11. Wire the gear operator. Refer to the Switch and Wiring section. 12. For 10-12-inch/23.0-323.9-mm valve sizes: Follow the steps on the following pages to adjust the gear operator s closed and open travel limit stops. _3

SERIES 5, 05,, and 0C SWITCH AND WIRING 1. The supervisory switch contains two, single pole, double throw, pre wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/0 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. For Series 5 and Series 05, switches supervise the valve in the OPEN position. For Series and Series 0C, switches supervise the valve in the CLOSED position. 4. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5. A #14 insulated ground lead (green) is provided. Switch #1 = S1 for connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue S1 Common: (2) Yellow S2 { { Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT SWITCH CONTACT RATING: 10A AT 125 AND 250VAC, 0.5A AT 125 VDC, 0.25 AT 250 VDC VOLTAGE SOURCE CONDUIT ½" NPT CONDUIT CONNECTORS N.C. NO. COM. S1 S2 Switch 1: 2 leads per terminal Switch 2: 1 lead per terminal UL LISTED JUNCTION BOX WIRE NUTS TO END-OF-LINE RESISTOR, OR NEXT INDICATOR BELL OR HORN NOTE: The above diagram shows a connection between the common terminal (yellow S1 and yellow-with-orange stripe S2) and the normally closed terminal (blue S1 and blue-with-orange strip S2). In this example, the indicator light and alarm will stay on until the valve is fully OPEN (for Series 5 and Series ) or fully CLOSED (for Series and Series 0C). When the valve is fully OPEN (for Series 5 and Series ) or fully CLOSED (for Series and Series 0C), the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only S1 (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 2 and the auxiliary switch per NFPA 0 (NEC). _4

SERIES 5, 05,, and 0C ADJUSTING THE TRAVEL LIMIT STOPS Adjustment of the travel limit stops can be performed while the system is operational. NOTE: Cycling of the valve to test travel limit stop adjustments may affect downstream equipment. Adjusting the Gear Operator s Closed Travel Limit Stops (10-12-inch/23.0-323.9-mm Sizes) 1. Turn the handwheel counterclockwise to ensure the valve disc is not in the fully closed position. 4. With the valve disc in the closed (shut) position, tighten the internal set screw (clockwise) with a 5/32 allen wrench. NOTICE System pressure upstream of the valve may increase while the valve disc is in the fully closed position. Flow downstream of the valve will be interrupted with the disc in the fully closed position. 2. Remove the dust cap from the right side of the gear operator. 5. Verify proper operation of the gear operator by turning the handwheel. 3. Using a 5/32 allen wrench, loosen the internal set screw counterclockwise to increase the distance for disc travel. 3a. Using a 5/32 allen wrench, tighten the internal set screw clockwise to decrease the distance for disc travel. 3b. Turn the handwheel in the clockwise direction to place the valve disc in the closed (shut) position to confirm that the valve is providing shutoff service. Repeat steps 3 and 3a, as necessary.. Replace the dust cap.. Follow the Adjusting the Gear Operator s Open Travel Limit Stops section on the following page. _5

SERIES 5, 05,, and 0C Adjusting the Gear Operator s Open Travel Limit Stops (10-12-inch/23.0-323.9-mm Sizes) 1. Turn the handwheel clockwise to place the valve disc in the slightly open position. 2. Remove the dust cap from the left side of the gear operator. 4. With the valve disc in the desired open position, tighten the internal set screw (clockwise) with a 5/32 allen wrench. 5. Verify proper operation of the gear operator by turning the handwheel.. Replace the dust cap. 3. Using a 5/32 allen wrench, loosen the internal set screw counterclockwise. 3a. Turn the handwheel to place the valve disc in the desired open position. _

SERIES 5, 05,, and 0C For complete contact information, visit 59 REV A UPDATED 09/2009 Z000BFVKIT VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.