TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

Similar documents
TECH XP600/1100 INSTALLATION AND OPERATION MANUAL

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

TECH XP250 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

TECH XP125 INSTALLATION AND OPERATION MANUAL.

TECH MX SERIES OPERATION AND INSTALLATION MANUAL. Manufacturer of UL Listed Products

MX MX SERIES 7 CAGE OPERATION AND AND INSTALLATION MANUAL MANUAL

The Power of Reliability INSTRUCTION MANUAL

Questions Section: Do you have questions that aren't covered? Please contact us!

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Owner s Manual. PowerVerterDC-to-AC Inverter

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

A6Z OPERATING MANUAL

SAFETY WARNINGS AND GUIDELINES

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Battery Power Inverters

Pure Sine Wave Inverter Charger

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

Inverter User Manual

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

A3Z OPERATING MANUAL

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

installation kit Ask your retailer!

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

SAM Series Power Inverter

PI1500X Power Inverter User s Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

General safety and installation information.

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

General Precautions. Personnel Precautions

ATD WATT INVERTER

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

BRAVO Inverter/Battery Charger. Table of Contents

A1P OPERATING MANUAL

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

1RECHARGEABLE APPLIANCES

12VDC TO 230VAC INVERTERS

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Owner s Guide. DC TO AC Power Inverter

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

ATD WATT INVERTER

FEATURES

User Manual 1KVA-5KVA INVERTER / CHARGER

Owner s Manual. PowerVerter PV1000HF, PV1800HF & PV3000HF DC-to-AC Inverters. Contents. Reliable AC Power Wherever You Need It!

Uninterruptible Power System

User Manual 1KVA-5KVA INVERTER / CHARGER

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

OWNER S MANUAL POWER INVERTER

Solar Hybrid Inverter SP Efecto Series

Solar Hybrid Inverter SP Efecto Series

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Phoenix Inverter

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Compact Sine Inverter

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

The Solar Shuttle Solar Trailer

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

XP800i POWER INVERTER OWNER S MANUAL

Power Inverter Vehicle Power System Converts DC Vehicle Power to 115 Volt AC Household Power

DC to AC Power Inverters

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

DC to AC Power Inverters

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Table of Contents 文管中心 發行章

Series 120/120VAC Universal Tower/Rack Mount

PureSine 150/300 Pure Sine Wave Inverter User s Manual

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Solar Hybrid Inverter SP Brilliant Series

PURE SINE WAVE DC-AC INVERTERS

MIL-24/2600Q MIL-24/3200DQ

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

WARNINGS, CAUTIONS AND NOTES

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

IQC IQC IQC

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

OWNERS MANUAL JANUARY 2007 ISO

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

R series solar charger inverter 1000W to 6000W

MEANWELL DC/AC POWER INVERTERS

S150,S300 Series Pure Sine Wave Inverter User s Manual

Transcription:

http://wwwwholesalesolarcom/invertershtml TECH 7317 Jack Newell Blvd North Fort Worth, Texas 76118-71 8175954969 voice, 817595129 fax 88864683 toll free website wwwexeltechcom R Manufacturer of UL Listed Products http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Copyright 21 Exeltech Inc All rights reserved This Document may not be copied, photocopied, reproduced, translated or converted to any electronic or machine-readable form in whole or in part without prior written approval of Exeltech Inc Acknowledgments Project Management: Ben Baker and John Goetz Writing: Gary Chemelewski Copy Editing: Ben Baker Art, Photography and Layout: John Goetz July 22 Exeltech 7317 Jack Newell Blvd North Fort Worth, Texas 76118-71 Page 1 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Table of Contents Introduction 1 Standard Features 2 Installation 3 Operation 4 Appendix A Appendix B Appendix C page 3 page 5 page 8 page 11 page 12 page 13 page 14 Page 2 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Introduction 1 Thank you for purchasing the finest sine-wave inverter in the power conversion industry Exeltech's journey to excellence includes the first affordable sine wave inverter, first modular inverter system, first N+1 redundant inverter system, and the cleanest sine wave output in the industry Exeltech strives to manufacture products of the highest possible quality, and is dedicated to 1% customer satisfaction Proudly built in the USA with American parts, Exeltech is committed to TL 9 standards and beyond, adding people and procedures continually to further improve quality and customer service We welcome you as a customer to the Exeltech family Congratulations! XP series inverters provide the cleanest, best regulated sine wave output over the widest DC input of any inverter on the market today They are extremely low in Total Distortion; specified to 2%, and typically better than 15% Total Harmonic Distortion is typically 8 to 9% Remaining distortion is a result of residual switching noise, which amounts to a very clean 25 KHZ sine wave superimposed on the fundamental output No significant harmonics of 25 KHZ exist This spectral purity will exist over the inverter's entire operating envelope, including non-linear and reactive loads As long as peak output current remains less than 3% of rated current, total harmonic distortion will remain within the 2% spec Peak current capability of the inverter is key to understanding it's operational envelope As long as the inverter is supplying less than this amount, it will function properly and operate virtually any load Many inverters are rated in Volt-Amps (VA), as opposed to Watts This is in an attempt to make an inverter or UPS (Uninterruptible Power Supply) appear larger than it really is The only fair way to Page 3 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml specify these products is in Watts (W), which is power the inverter can actually deliver If Exeltech inverters were specified in VA, Our 11 Watt inverter could be rated at 1375 VA at 8 power factor, 157 VA @ 7 pf, or an incredible 22 VA @ 5 pf It is confusing to specify a product in VA, because the power factor must also be specified Exeltech's XP-Series inverters can output their full rated o o power continuously at 3 C (86 F) The inverter can maintain a spectrally pure output with any load, due to a specially designed non-linear control loop in the primary DC to DC converter This circuitry is one of three circuits which protect the inverter from any overload condition XP-6 and XP-11 These inverters can supply twice their rated output power for 3 seconds, in order to start motors or supply in-rush currents to electronic loads If output power is exceeded for greater than 3 seconds, output voltage is reduced to a level which will provide the inverter s rated power to the load by clipping tops of the waveform The inverter can operate safely in this mode indefinitely Should the overload condition clear, the inverter will again provide the cleanest Sine Wave in the industry This over-current circuitry insures maximum peak current does not exceed 3% of rated RMS current Should this number be exceeded, it will again reduce output voltage as required to maintain that limit Again, the inverter can operate in this mode indefinitely, so that when the overload clears, output voltage is automatically restored The third protection mechanism is short circuit If the inverter exceeds it s peak current (Ip) capacity for a prolonged period, it will shut off automatically The period of time required to shut off changes with the degree of overload A high overload shuts off in one second A slight overload may require several seconds This typically requires a 5 ohm load per 1 Watts, for several seconds This guarantees the inverter is disabled, in the event that the user attempts to clear the short without first shutting off the inverter The inverter in fact, acts as an extremely high performance circuit breaker The short circuit and overload circuitry responds much faster than any normal fuse or breaker, so no external current limiting devices are necessary Exeltech s XP-Series inverters can output their full rated power continuously at 3C (86F) The inverter is derated 2% of its Page 4 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml full power for every 1 degrees C over 3 degress C IE; 8% of normal capacity at 4 degrees C, 6% at 5 degrees C etc Standard Features 2 DC INPUTS: Positive (+) and Negative (-) input terminals are 5/16" studs with brass hardware They are accessed under the Rear Cover Use Appendix A to choose the appropriate gauge wire for your specific model REMOTE ON/OFF: provides the User with a remote method to turn the inverter on and off REMOTE connection is on the barrier terminal strip located under the Rear Cover AC OUTPUTS: All models (* except 23 VAC output) have two, NEMA 5-15R outlets (standard wall receptacle), located on the Front Panel Additionally; they may be hard-wired to appliance / load using connections on the barrier terminal strip (under Rear Cover) COOLING: is provided by a thermostatically controlled brushless fan located on the Front Panel DC POWER ON LED: located on the front panel, will be "ON" when inverter is powered up, and DC power is available LOW BATT / THERM BUZZER: produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, or, if there is an over temperature condition * XP-11, XP-6 23 VAC, inverters have an IEC-32 receptacle located on the Front Plate Page 5 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml ON/OFF SWITCH: off located on front panel; turns the inverter on and OVER VOLTAGE PROTECTION: If input voltage to the inverter exceeds set limits, the inverter will immediately and without warning shut off When input voltage returns to normal range, the inverter will immediately restart Since high over voltages tend to have very fast edges, the inverter must shut down quickly to protect itself This kind of fault usually occurs if the battery is suddenly disconnected from the system and the battery charger continues to supply current UNDER VOLTAGE PROTECTION: When battery voltage falls to within 2% to 4% of low line voltage, the LOW BATT / THERM buzzer will sound If the condition continues without reducing load to the inverter or adding charge to the battery, the inverter will shut off When voltage rises to approximately 95% of nominal battery voltage, the inverter will turn back on and the alarm condition will clear The inverter can be manually reset by cycling the on/off switch This will reset the protection circuit and turn the inverter on at any voltage above minimum voltage OVER TEMPERATURE PROTECTION: The inverter is also protected against overheating It will provide its full rated output up to the temperature listed in the specification sheet If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter may overheat If the LOWBATT/ THERM buzzer sounds, immediate action is required or the inverter will shut down Either reduce load, or provide more cooling in the immediate environment If no action is taken, the inverter will likely shut down within 2 minutes When the inverter shuts down, the alarm condition will persist and the cooling fan will continue to run Since the inverter has eliminated its load, it will cool fairly quickly It will automatically restart when it has cooled sufficiently, and the LOW BATT/THERM alarm will clear 15 C internal temperature Warning buzz 5 C before shut off OVERPOWER, SHORT CIRCUIT PROTECTION: The inverter has three levels of overpower protection The first limits peak instantaneous current The second system limits absolute power coming from the module Both of these circuits act to reduce output Page 6 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml voltage as required, to limit current to a safe level The overpower protection circuit will recover instantly when the overpower condition clears The third, is short circuit protection If the over current condition is so severe that it causes output voltage to collapse to 1 Vp for more than 1 second, the inverter will shut down and not automatically restart This requires the user to clear the short circuit safely, and guarantee that hazardous voltage will not come back on line until desired To reset the inverter from this condition, cycle power switch OFF then ON again Page 7 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Installation 3 CAUTION: It is essential to read and understand all Warnings, Cautions, and Notes before any connections are made to the Unit or System If further assistance is needed call (817)595-4969 and ask for Customer Service WARNING: The inverter is designed to operate from a Battery Performance cannot be guaranteed, and damage can result when a charger or power supply is used without a battery in the circuit WARNING: The AC neutral lead is bonded to chassis through the barrier terminal strip connector located on the back of unit Chassis must be bonded to earth ground through the external ground connector located on the rear of the unit (See illustration on page 14) The Negative or Positive terminal of the battery (DC Source) must be bonded to earth ground It's recommended that it be to the same earth ground used for AC ground Refer to the figure for wiring illustration Battery (A) + - - + A) Positive earth ground B) Negative Earth Ground *Note: Only A or B NOT BOTH Inverter CAUTION: Before any connections are made to the Unit or System, be sure to disconnect the battery terminals Always disconnect the grounded battery terminal first When re-connecting, connect ungrounded terminal first, and grounded terminal last Page 8 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml CAUTION: Polarity of leads is critical to avoid damage to the unit or system Check batteries and battery cables for correct polarity and voltage CAUTION: Observe all National and Local Electric Codes when connecting AC Power Connections INSTALLATION (Location) Mounting location is critical to performance and life span of the inverter Heat and Moisture are the two worst enemies of any electronic device Therefore, when choosing a mounting location, consider the following requirements listed in order of importance: 1 Inverter must be sheltered from the elements Select a clean, dry location 2 Inverter requires adequate ventilation for cooling With proper cooling, the inverter will operate efficiently and meet its published ratings All models can be mounted in several positions Best position, with fan down Second best, horizontal Third, vertical with fan up Least preferred, upside down 3 Inverter should be mounted as close to the battery as possible Shorter wire has less resistance, which translates to increased efficiencies INSTALLATION (Wiring) An in line fuse is recommended, to protect the battery and wiring to the inverter This fuse should be located very close to the battery positive (+) terminal To select appropriate size fuse, consult the "Rated and Peak Current" table in appendix "A" XP-6 and XP-11: Positive (+) and Negative (-) input terminals are 5/16" studs with brass hardware They are provided under the Rear Cover Use Appendix A to choose the appropriate gauge wire for your specific model and distance from the battery 1 Disconnect the grounded terminal of battery and make sure the charger and inverter are off Page 9 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml 2 Make DC input connections to the inverter as illustrated in Appendix C 3 (Optional) Using 12-18 AWG wire, make Remote On/Off connection from the Rear Panel terminal labeled REMOTE to one pole of a small toggle switch Then from the other pole of toggle switch, make a connection to battery negative (-) 4 Make sure the toggle switch is off Note: in order for the Remote On/Off switch to operate inverter, On/Off switch on the Front Panel must be off 5 Appliances / Loads may be hard wired to the rear terminal strip (shown in Appendix C ), in addition to the loads plugged into the front outlets The sum of the loads must not exceed the inverter output capability Page 1 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Operation 4 TURN ON INVERTER: XP-6 and XP-11: Turn inverter on using Toggle Switch on Front Panel, or the "REMOTE" switch if installed LED next to the switch will illuminate, indicating the inverter is operational Note: If using "REMOTE" switch, the Front Panel Switch must be off (If either switch is "on", the inverter will turn on Both switches must be off for the inverter to turn off) TURN ON APPLIANCE/LOAD: 1 Check Input Power Requirements of the appliance Make sure that it is less than Rated Output Power of the inverter If more than one appliance will be run simultaneously, the sum of their Input Power Requirements must be less than Rated Output Power of the inverter 2 If Appliance/Load has been hard wired to the barrier terminal strip as illustrated in Appendix "C", then turn appliance on Otherwise; 3 Plug the appliance into the provided receptacle on Front Panel, then turn appliance on Note: It is recommend that the inverter be turned ON before the appliance/load Page 11 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Input Power Requirements: APPENDIX A MODEL NORMAL VDC MINIMUM VDC CUT-OFF / ALARM MAXIMUM VDC RATED PEAK CURRENT CURRENT XP-6 / 12VDC 138 VDC 14 / 16 VDC 165 VDC 588 A 666 A XP-6 / 24VDC 276 VDC 19 / 21 VDC 33 VDC 294 A 336 A XP-6 / 48VDC 552 VDC 415 / 425 VDC 62 VDC 147 A 166 A XP-6 / 66VDC 759 VDC 575 / 585 VDC 91 VDC 17 A 121 A XP-6 / 18VDC 124 VDC 94 / 95 VDC 149 VDC 65 A 74 A XP-11 / 12VDC 138 VDC 14 / 16 VDC 165 VDC 178 A 1221 A XP-11 / 24VDC 276 VDC 19 / 21 VDC 33 VDC 539 A 616 A XP-11 / 48VDC 552 VDC 415 / 425 VDC 62 VDC 27 A 35 A XP-11 / 66VDC 759 VDC 575 / 585 VDC 91 VDC 196 A 221 A XP-11 / 18VDC 124 VDC 94 / 95 VDC 149 VDC 12 A 136 A Recommended Input Wire Sizes (For Variable Distances from the Battery): MODEL LESS THAN 5 LESS THAN 1 LESS THAN 15 LESS THAN 2 XP-6 / 12VDC 4 AWG AWG AWG AWG XP-6 / 24VDC 1 AWG 6 AWG 4 AWG 4 AWG XP-6 / 48VDC 16 AWG 12 AWG 1 AWG 1 AWG XP-6 / 66VDC 18 AWG 16 AWG 14 AWG 12 AWG XP-6 / 18VDC 18 AWG 18 AWG 18 AWG 16 AWG XP-11 / 12VDC AWG AWG AWG AWG XP-11 / 24VDC 6 AWG 4 AWG 2 AWG AWG XP-11 / 48VDC 12 AWG 1 AWG 8 AWG 6 AWG XP-11 / 66VDC 16 AWG 12 AWG 1 AWG 1 AWG XP-11 / 18VDC 18 AWG 16 AWG 14 AWG 14 AWG Note: The table specifies standard wire sizes (not smaller than 18 AWG) that will provide less than a 2% voltage drop at Low-line Input voltage and Rated Output Power See page 13 for Mechanical dimensions and mounting hole locations Page 12 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml 121 9342 8897 TOP APPENDIX B XP6 125 DIA 4 PLCS 128 78 281 3565 375 FRONT 7315 769 3565 SIDE 769 769 121 155 12345 11842 TOP XP11 125 DIA 4 PLCS 128 78 281 3565 375 FRONT 7315 769 3565 SIDE 155 Page 13 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml APPENDIX C Note: Use Rated Current and voltage in Appendix "A" to select an appropriate Toggle Switch or Relay for your specific model inverter XP-6 and XP-11 with DC Toggle Switch: + XP-6 and XP-11 with DC Relay: + Battery - DC Toggle Switch (See Appendix A) Normally Open Contacts + - Inverter Battery - DC Toggle Switch (Low Current) Relay Coil Relay + - Inverter INSTALLATION CAUTION: Be sure to disconnect all DC power to installation wiring Be sure to disconnect batteries and chargers Make all connections to the inverter BEFORE connecting DC leads to the battery DO NOT REMOVE THE BONDING STRIP (Ground to Neutral) unless grounding of neutral is accomplished elsewhere, such as at a service entrance box Maintain ground connection in any case XP-6 and XP-11 Rear View with access cover removed (AC/DC Connections): Bonding strip GROUND NEUTRAL LINE REMOTE BAT + BAT - Page 14 http://wwwwholesalesolarcom/invertershtml

http://wwwwholesalesolarcom/invertershtml Made in the USA Document subject to change without notice 931-X61M*-*C TECH 7317 Jack Newell Blvd North Fort Worth, Texas 76118-71 8175954969 voice, 817595129 fax 88864683 toll free website wwwexeltechcom http://wwwwholesalesolarcom/invertershtml