neptunetg.com Neptune Technology Group Inc Alabama Highway 229 Tallassee, AL USA Tel: (800) Fax: (334)

Similar documents
HP Turbine Installation and Maintenance Guide

TRU/FLO Compound Installation and Maintenance Guide

ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC. HP Fire Service Turbine Installation and Maintenance Guide

E-Coder)R900i Quick Install Guide. E-CODER)R900i QUICK INSTALL GUIDE

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC GAS. E-Coder)R900i Quick Install Guide. E-Coder)R900i QUICK INSTALL GUIDE

Flow Control Valve IOM 770-U

NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

Fisher 644 and 645 Differential Pressure Pump Governors

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Type 644 and 645 Differential Pressure Pump Governors

IFOA Integral Flow Orifice Assembly

PRESSURE RELIEF VALVE

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

EZ-IN Series Turbine Flowmeter

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Retractable System Operation & Maintenance Manual

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

MODEL 1100 TURBINE FLOW METER

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Y690A Series Pressure Reducing Regulators

ERHARD is a company of. Data sheet ERHARD needle valves

FIXED DEPTH INSERTION METER INSTRUCTIONS

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Type 289RC Exhaust Booster

Industrial Turbo Meters, Sizes 2" through 6"

Operation and Maintenance Manual

Liquid Turbine Flowmeter

MODEL 200 MULTI-JET FLOW METER

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

User Manual. Recordall Compound Series Meter. Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified

Y690A Series Pressure Reducing Regulators

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Crispin Valves Operating Guide. Crispin

Model Horizon. Horizon. Horizontal Turbine Meters Sizes 1-1/2" through 10" NOTICE OF DISCONTINUATION, Effective October 2011

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

CV Control Valves Installation and Operation Manual

Type EZR Relief Valve or Backpressure Regulator

Operation Manual Woltman. Operation Manual WOLTMAN Water Meters

Welker Gas Sampler Model MPS-2

SEALING DIP CAP INSTALLATION GUIDE

Installation, Maintenance, & Repair Series 919 and LF919

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14)

Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual

Pilot-Operated Regulators

Installation. Installation. 12. System Diagram... 10

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

INSTALLATION INSTRUCTIONS

MODEL 200 MULTI-JET FLOW METER

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

MODEL 900 IMPELLER-TYPE FLOW METER

Flow limiter SP/SMB3 Flow limiter SP/SMB6

SINGLE ACTING ALTITUDE VALVE

Fisher 3024C Diaphragm Actuator

E-training. Operating characteristics and sizing of pneumatic actuators. The main types of pneumatic actuator

Pressure Reducing Valve Type 2114/2415

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

4-20 ELECTRONIC VERTICAL FLOW METERS

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

TX101/201 Insertion Turbine Instructions

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

MUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6

LIQUID MEASUREMENT STATION DESIGN Class No

289 Series Relief Valves

type 122a three-way Switching Valve

PRESSURE REDUCING VALVE

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION

Surface CIMV, Low Flow, HTV, Manual

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

ROOTS Meters Series B3 Meter Models 8C175-56M175

Flow limiter SP/SMB9 for mounting plates

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

POSITIVE DISPLACEMENT FLOWMETERS

KEYSTONE SERIES GR RESILIENT SEATED BUTTERFLY VALVES GRW/GRL INSTALLATION AND OPERATION MANUAL

FIRE HYDRANTS. Wet Barrel Fire Hydrants

Type EZR Relief Valve or Backpressure Regulator

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Hopkinsons Fig 9052 VALVE ACTUATOR

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Fisher 2052 Diaphragm Rotary Actuator

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Pneumatic Actuator. Operation & Service Manual. Models: Original Instructions UNIBLOC PUMP MANUAL NO.: REVISION: 08/2016

FIRESAFE & LETHAL SERVICE BALL VALVE CATALOGUE //

PEB & PESB Valve Installation and Operating Instructions Troubleshooting Guide

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidVertic Vertical Vortex Valve

Baumann Series Flexsleev Control Valve Instructions

UD and UC Gear pump unit

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Model 1100 Turbine Flow Meter

Transcription:

Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (800) 645-1892 Fax: (334) 283-7299 Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503 neptunetg.com IM TURB 08.08 Copyright 2008, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.

ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC HP Turbine Installation and Maintenance Guide HP TURBINE INSTALLATION AND MAINTENANCE GUIDE

ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC HP Turbine Installation and Maintenance Guide

This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Neptune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to Neptune Technology Group Inc. Neptune engages in ongoing research and development to improve and enhance its products. Therefore, Neptune reserves the right to change product or system specifications without notice. Trademarks Used in this Manual Neptune is a registered trademark of Neptune Technology Group Inc. Other brands or product names are the trademarks or registered trademarks of their respective holders. Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (800) 645-1892 Fax: (334) 283-7299 Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE Literature No. IM TURB 08.08 Copyright 2008, Neptune Technology Group Inc. All rights reserved.

CONTENTS 1 INSTALLING THE HP TURBINE Installation Instructions...1-1 Recommended Installation...1-1 Before Operation...1-3 2 MAINTENANCE Adjusting the HP Turbine Calibration Vane...2-2 1-1/2 and 2 HP Turbines...2-2 3-20 HP Turbines...2-3 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE iii

NOTES iv HP TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 1 INSTALLING THE HP TURBINE This chapter is designed to take you through the installation process for the High Performance (HP) Turbine. CHAPTER 1 INSTALLING THE HP TURBINE The HP Turbine offers the widest operating range of any turbine meter on the market. To achieve optimum performance in actual service, it is essential that you follow these installation instructions. INSTALLATION INSTRUCTIONS All HP Turbine meters operate more accurately and reliably if installed properly. Turbine meter performance is directly related to the flow conditions of the water stream entering the meter. If the flow conditions are distorted because of upstream fittings or piping changes, a turbine meter s performance can be adversely affected. Neptune recommends that you install all HP Turbine meters with a Neptune strainer at the meter inlet. The strainer, in addition to protecting the meter from debris in the line, also corrects the velocity profile of the flow to the meter and reduces the effects of upstream piping variations or other obstructions in the line. When installing Neptune meters with a strainer, a minimum of four (4) pipe diameters of straight run pipe (can include components that are fully open in their normal operating position) is required upstream and downstream of the meter/strainer assembly. If you do not use a strainer, a length of straight pipe equal to 8 to 10 diameters of the nominal pipe size should be allowed immediately upstream of the meter inlet and 2 to 4 diameters downstream. When installing an HP Turbine meter, please use the following instructions. RECOMMENDED INSTALLATION Figure 1.1 shows the recommended installation of an HP Turbine meter. This installation incorporates a Neptune strainer attached to the inlet of the meter and includes a downstream tee to facilitate field testing. This illustration also shows an optional bypass that provides uninterrupted service capability during periods of meter service. As indicated previously, the Neptune strainer located upstream provides protection against meter damage from debris in the lines and virtually eliminates the effects of variations in upstream piping. Neptune specifically recommends use of a Neptune strainer of the same line size as the meter. HP TURBINE INSTALLATION AND MAINTENANCE GUIDE 1-1

CHAPTER 1 INSTALLING THE HP TURBINE TOP VIEW Bypass Strainer Gate Valve SIDE VIEW Testing Tee Turbine Meter Figure 1.1 Top and Side View of the HP Turbine This strainer design provides optimum velocity profile correction at minimum additional head loss. The installation of the test tee can be at any convenient location where the test outlet is two pipe diameters or more downstream of the water meter outlet. We recommend this to provide a means to field test the meter without removing it from the line. When installing HP Turbine meters, always follow normal good piping practice. Specifically, all gaskets should be centrally located on the flanges with no overlap or interference with the pipe diameter. This is particularly important at the inlet connection to the meter where a gasket protruding into the flow stream will cause unpredictable velocity conditions. Turbine meters must operate in a completely filled line at all times. The downstream piping must always provide sufficient back pressure to maintain a full line at the meter. 1-2 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE

Caution should be exercised to avoid air in the line, sudden flow surges, or excessive flow rates, as these conditions may cause damage to the turbine measuring element. BEFORE OPERATION Before putting the HP Turbine meter in service follow these steps: 1 With outlet-side gate valve closed, SLOWLY open inlet-side valve to pressurize meter. 2 SLOWLY open outlet-side gate valve until downstream line is pressurized. CHAPTER 1 INSTALLING THE HP TURBINE After installation, it is important that you put the the upstream (inlet) valve in the full open condition during service. A partially throttled upstream valve without a strainer installed will cause flow profile distortion that will adversely affect meter accuracy. All throttling should be done ONLY on the downstream (outlet) side of the meter. HP TURBINE INSTALLATION AND MAINTENANCE GUIDE 1-3

NOTES 1-4 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 2 MAINTENANCE CHAPTER 2 MAINTENANCE When maintenance is necessary, the complete Unitized Measuring Element (UME) may be quickly and easily interchanged with a factory-calibrated unit (see Figure 2.1). Figure 2.1 Factory-Calibrated Unit This unit includes register, cover, and turbine measuring element. Follow these steps: 1 Close valves. 2 Remove cover bolts. 3 Remove UME from maincase. 4 Remove old maincase gasket and replace a new gasket. 5 Install factory-calibrated unit into maincase. 6 Replace cover bolts. 7 Tighten cover bolts. 8 Open valves. All UMEs have been factory calibrated and should not require field calibration. HP TURBINE INSTALLATION AND MAINTENANCE GUIDE 2-1

CHAPTER 2 MAINTENANCE Refer to meter installation instructions. The complete UME should be returned for service to Neptune. If the customer does not have a spare unit, a factory-calibrated exchange unit may be purchased from Neptune. Neptune encourages all customers to purchase either a spare UME complete or a UME exchange contract to enable them to avoid service interruptions. ADJUSTING THE HP TURBINE CALIBRATION VANE Neptune equips all HP Turbine meters and UMEs with a calibration vane. Should the turbine element require field calibration, follow these steps: 1-1/2 and 2 HP Turbines 1 Cut seal wire and remove tamper resist cap. 2 Loosen lock nut by turning counter-clockwise. 3 Insert slotted screwdriver into slot in top of adjusting stem and a Turn clockwise to decrease registration, or; b Turn counter-clockwise to increase registration. Turning the adjustment stem 3 in either direction results in approximately 1% change in registration. The full range of the calibration vane is 30 degrees (see Figure 2.2). 2-2 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 2 MAINTENANCE Figure 2.2 1-1/2 and 2 HP Turbines 3-20 HP Turbines The calibration adjusting stem is located inside the register mounting ring for the 3-20 HP Turbines. Should the turbine element require field calibration, follow these steps: 1 Remove seal pin from register and twist off register (3-10); or remove lead seal and unscrew register adapter screws (12-20 ). 2 Loosen lock nut on adjusting stem by turning counter-clockwise. 3 Insert slotted screwdriver into slot in top of adjusting stem and a Turn clockwise to decrease registration, or; b Turn counter-clockwise to increase registration. Turning the adjustment stem 15 in either direction results in approximately 1% change in registration. The full range of the adjustment stem is 180 (see Figure 2.3). Figure 2.3 3-20 HP Turbines HP TURBINE INSTALLATION AND MAINTENANCE GUIDE 2-3

NOTES 2-4 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE