Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Similar documents
Accessories Standard Service Fixture Kits

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector XStream Laboratory Hoods

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Laboratory Fume Hoods & Enclosures

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Laboratory Fume Hoods & Enclosures

Protector Demonstration Hoods

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

F. VAV hoods shall have a restricted bypass plate.

LABORATORY FUME HOODS OF 5

Protector Controlled Atmosphere Glove Boxes

Pre-Wired and Pre-Piped

Laboratory Carts & Benches

Protector Echo Filtered Fume Hoods

Labconco 48, 60, and 72 Hoods

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

FUME HOOD SELECTION GUIDE

PRECISE. Glove Boxes

Protector Airo Filtered Fume Hoods

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

Supreme Air Fume Hood Option Availability

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

Protector ClassMate Laboratory Fume Hoods. Models Series Series Series Series Series Series

PROTECTOR. Glove Boxes. Controlled Atmosphere and Multi-Hazard

Completing Your Fume Removal System

PROTECTOR FIBERGLASS ENCLOSURES

V05 General Purpose Bench Fume Hood

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Appendix C: Biosafety Cabinet Specifications C-1. Product Service

Refrigerators/Freezers

Protector Laboratory Fume Hoods & Enclosures Overview

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

LABORATORY FUME HOODS

General Plumbing Information

User s Manual. Protector Laboratory Fume Hoods. Premier Models. XL Models

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

Precise Glove Boxes & XPert Weigh Boxes

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

AUDIO-VISUAL EQUIPMENT

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

HEMCO. Laboratory Fume HoodsR

Engineering Information

CORPORATION DURALAB CORPORA

LABORATORY SERVICE FIXTURES

Fume Hoods Overview OVERVIEW

User s Manual. Protector Laboratory Fume Hoods

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

82863_Graphx_Conn:Layout 1 11/26/08 8:59 AM Page 1 DUCTLESS ENCLOSURES

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Protector XStream Laboratory Fume Hoods

with color-coded index disc. installation on straight face of hood. Valve is installed from behind panel and is secured with external locking ring on

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

User s Manual. Protector XL Floor-Mounted (Walk-In) Laboratory Fume Hoods. Models

Open Access Stations Introduction

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

January, 2014 Page 1 of 6

LABORATORY FUME HOODS

Square Inline Fans with Multi-Directional Discharge

Direct Gas-Fired Heating

AUDIO-VISUAL EQUIPMENT

Logic+ Technical Manual and Specifications. Type B2 Biosafety Cabinet Models

User s Manual. Fiberglass 30 Laboratory Fume Hoods. Models Labconco s Mascot, Labby the LABster

User s Manual. XPert Filtered Balance Enclosures & Protector XVS Ventilation Stations. Models

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Uncompromised safety. NSF listing provides assurance that you, your work and your laboratory environment are protected while working with agents that

When Time Matters! listed Fire Damper

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

new fume hoods providing performance and protection

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

Model ND-2 Specification

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

EGG CRATE RETURN GRILLE

Mobility Optima Mobile Workstation

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Ventilated Balance Enclosures

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SOLAR HEATING SYSTEM

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of:

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

WAC Air Curtains Technical Guide

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Lighthouse Power Pedestals,

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Transcription:

Protector XL FLOOR-MOUNTED LAORATORY HOODS

Protector XL Floor-Mounted Laboratory Hoods Features & enefits Protector XL Floor-Mounted Laboratory Hoods accommodate laboratory procedures that require over-sized equipment or maximum work area. Users with applications requiring distillation racks, extraction apparatus or large drums and carboys benefit from the increased height these hoods provide. Protector XL Floor-Mounted Laboratory Hoods are supplied in three depths and several widths up to 16 feet. Depending on the model, these hoods have vertical-rising or horizontal-sliding sashes. Front and side panels may be easily removed for lamp replacement and access to electrical supply connections. ETL-listed. Hoods carry the ETL mark signifying that they are certified to UL 3101-1/61010-1, UL 1805 and AN/SA 22.2 No.1010.1. Durable and attractive exterior is glacier white, dry powder epoxycoated steel. Tempered safety glass sashes are anti-racking for smooth operation. Hoods feature either vertical-rising or horizontal-sliding sashes depending on hood model. When fully open, vertical-rising sashes do not extend above the hood. Adjustable baffles provide a uniform face velocity pattern across the sash opening of the hood. Fluorescent lighting illuminates the interior. The high-efficiency, instant start, T8 fluorescent lights are located outside the hood interior for corrosion-resistance and easy replacement. ontact Labconco for ordering information on explosionproof lighting. Pre-wired electrical components. Fluorescent lights and switches are factory-wired to the hood s single point junction box. One electrical duplex receptacle is factory-wired on fixtured models. Each hood is factoryprepared for up to four electrical duplexes and an airflow monitor. Interior working dimensions are offered in standard and larger depths. Working depths include 30", 36" and 48". Performance tested to ASHRAE 110-1995. y-pass airflow design ensures relatively stable face velocities. olor-coded service fixtures for gas, air, water, vacuum and other services have remote controls for use regardless of the sash position. Two service fixtures are pre-plumbed on fixtured models. Each hood is factory prepared for up to eight service fixtures (four on each side). Service access panels allow easy accessibility to plumbing from the front and inside of the hood. hemical-resistant, fiberglassreinforced composite panel liner surpasses all national codes for flame spread and has a bright white surface for excellent light reflectivity. 2

Protector XL Floor-Mounted Laboratory Hoods 6' Protector XL Floor-Mounted Laboratory Hood 9860601. lower and ductwork must be ordered separately. Fixtured models feature: Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. omponents for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided. One pre-wired 115 volt, 20 amp electrical duplex receptacle on lower right side. Requires Ductwork and lower 8' Protector XL Floor-Mounted Laboratory Hood 9700805. lower and ductwork must be ordered separately. All models require (not included): Remote lower. Request lowers ooklet. Ductwork. Request lowers ooklet. All models feature: y-pass airflow design. Glacier white, dry powder epoxy-coated steel exterior. hemical-resistant, fiberglass-reinforced composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84. Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring. Pre-wired T8 fluorescent lighting, light and blower switches for 115 volt, 60 Hz operation. Shipped in multiple sections: top, bottom and sashes. Epoxy-coated stainless steel, 12.81" ID exhaust connection(s). 4', 5', 6' and 8' models feature: Two 3/16" thick tempered safety glass vertical-rising sashes framed with PV (4', 5' and 6' models) or epoxy-coated aluminum (8' models). Sashes do not extend above the hood when fully open. 8', 10', 12' and 16' models feature: Four 3/16" thick tempered safety glass horizontal-sliding sashes with epoxycoated aluminum frames and sash tracks. All models conform to the following regulations and standards: SEFA 1-2006 NFPA 45-2004 ASTM E84-09 ASHRAE 110-95 ANSI Z9.5-2003 UL 3101-1/61010-1 AN/SA 22.2 No. 1010.1 UL 1805 Optional accessories for on-site installation include: Service Fixture Kits. See page 7. Side-Mount Oval upsink. See back cover. Electrical Duplex Kits. See back cover. Guardian Airflow Monitor Kits. See back cover. ontact Labconco at 800-821-5525 or 816-333-8811 for ordering information on ceiling enclosure and rear finish panel kits, fire extinguishers, explosion-proof lighting, solid epoxy floors, tissue screens and distillation grids; and for blower sizing assistance. Heights of switches, electrical receptacle and service fixtures meet requirements of ADA. 3

Ordering Information 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes Exterior Interior 12.81" (32.5 cm) Shipping Nominal atalog Depth (A) Depth () ID Exhaust Fluorescent Service Electrical Weight Width Number inches/cm inches/cm ollar(s) Lamps Fixtures Duplex lbs./kg 4 Feet 9860401 39.20/99.6 30.00/76.2 1 2 ea. 25 watt 2 1 700/318 9860403 45.20/114.8 36.00/91.4 1 2 ea. 25 watt 2 1 715/324 9860405 57.20/145.3 48.00/121.9 1 2 ea. 25 watt 2 1 745/338 5 Feet 9860501 39.20/99.6 30.00/76.2 1 2 ea. 32 watt 2 1 815/370 9860503 45.20/114.8 36.00/91.4 1 2 ea. 32 watt 2 1 830/376 9860505 57.20/145.3 48.00/121.9 1 2 ea. 32 watt 2 1 860/390 6 Feet 9860601 39.20/99.6 30.00/76.2 1 2 ea. 32 watt 2 1 940/426 9860603 45.20/114.8 36.00/91.4 1 2 ea. 32 watt 2 1 955/433 9860605 57.20/145.3 48.00/121.9 1 2 ea. 32 watt 2 1 985/447 8 Feet 9700807 39.20/99.6 30.00/76.2 2 4 ea. 25 watt 2 1 1180/535 9700809 45.20/114.8 36.00/91.4 2 4 ea. 25 watt 2 1 1195/542 9700811 57.20/145.3 48.00/121.9 2 4 ea. 25 watt 2 1 1225/556 Nominal Total Exhaust FM and Static Pressure with sashes 50% open Width 100 fpm S.P. 80 fpm S.P. 4 Feet 680 0.16" 550 0.10" 5 Feet 900 0.24" 720 0.16" 6 Feet 1120 0.28" 900 0.18" 8 Feet 1560 0.19" 1250 0.12" Ordering Information 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes Exterior Interior 12.81" (32.5 cm) Shipping Nominal atalog Depth (A) Depth () ID Exhaust Fluorescent Service Electrical Weight Width Number inches/cm inches/cm ollar(s) Lamps Fixtures Duplex lbs./kg 8 Feet 9700801 39.20/99.6 30.00/76.2 2 4 ea. 25 watt 2 1 1130/513 9700803 45.20/114.8 36.00/91.4 2 4 ea. 25 watt 2 1 1145/519 9700805 57.20/145.3 48.00/121.9 2 4 ea. 25 watt 2 1 1175/533 10 Feet 9700901 39.20/99.6 30.00/76.2 2 4 ea. 32 watt 2 1 1375/624 9700903 45.20/114.8 36.00/91.4 2 4 ea. 32 watt 2 1 1390/630 9700905 57.20/145.3 48.00/121.9 2 4 ea. 32 watt 2 1 1420/644 12 Feet 9701001 39.20/99.6 30.00/76.2 2 4 ea. 32 watt 2 1 1645/733 9701003 45.20/114.8 36.00/91.4 2 4 ea. 32 watt 2 1 1660/753 9701005 57.20/145.3 48.00/121.9 2 4 ea. 32 watt 2 1 1690/767 16 Feet 9716001 39.20/99.6 30.00/76.2 4 8 ea. 25 watt 2 1 2085/946 9716003 45.20/114.8 36.00/91.4 4 8 ea. 25 watt 2 1 2100/953 9716005 57.20/145.3 48.00/121.9 4 8 ea. 25 watt 2 1 2130/966 Nominal Sashes Total Exhaust FM and Static Pressure Width Open 100 fpm S.P. 80 fpm S.P. 8 Feet 2 2200 0.30" 1760 0.19" 10 Feet 1 1360 0.12" 1090 0.08" 12 Feet 1 1660 0.15" 1330 0.10" 16 Feet 1 2260 0.10" 4

Dimensional Data 4', 5', 6' and 8' Protector XL Floor-Mounted Laboratory Hoods with vertical-rising sashes 4.91" (12.5 cm) 2.27" (5.8 cm) 4.91" 2.27" 12.81" ID Exhaust ollar TOP 4', 5', 6' 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars TOP (8') 10.53" 2.50" dia. Service Fixture Supply Holes E Single Point Internal Junction ox 10.53" (26.7 cm) D Single Point Internal Junction ox A* * * D* E* F* H* 4' Hood 9860401 48.00 38.25 24.00 39.20 30.00 58.81 (121.9) (97.2) (61.0) (99.6) (76.2) (149.4) 9860403 48.00 38.25 24.00 45.20 36.00 58.81 (121.9) (97.2) (61.0) (114.8) (91.4) (149.4) 9860405 48.00 38.25 24.00 57.20 48.00 58.81 (121.9) (97.2) (61.0) (145.3) (121.9) (149.4) 5' Hood 9860501 60.00 50.25 30.00 39.20 30.00 58.81 (152.4) (127.6) (76.2) (99.6) (76.2) (149.4) 9860503 60.00 50.25 30.00 45.20 36.00 58.81 (152.4) (127.6) (76.2) (114.8) (91.4) (149.4) 9860505 60.00 50.25 30.00 57.20 48.00 58.81 (152.4) (127.6) (76.2) (145.3) (121.9) (149.4) 6' Hood 9860601 72.00 62.25 36.00 39.20 30.00 58.81 (182.9) (158.1) (91.4) (99.6) (76.2) (149.4) 9860603 72.00 62.25 36.00 45.20 36.00 58.81 (182.9) (158.1) (91.4) (114.8) (91.4) (149.4 9860605 72.00 62.25 36.00 57.20 48.00 58.81 (182.9) (158.1) (91.4) (145.3) (121.9) (149.4) 8' Hood 9700807 96.00 86.25 24.00 39.20 30.00 48.00 59.00 (243.8) (219.1) (61.0) (99.6) (76.2) (121.9) (149.9) 9700809 96.00 86.25 24.00 45.20 36.00 48.00 59.00 (243.8) (219.1) (61.0) (114.8) (91.4) (121.9) (149.9) 9700811 96.00 86.25 24.00 57.20 48.00 48.00 59.00 (243.8) (219.1) (61.0) (145.3) (121.9) (121.9) (149.9) *Inches (centimeters) A D Fluorescent Lights 4.19" (10.6 cm) 68.15" (173.1 cm) Viewing Height to Floor H Sash Opening Front Access Panel (one on each side) Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" (5.1 cm) Interior Access Panels 15.00" (38.1 cm) Upper abinet Lower ase E 36.00" 77.00" (195.6 cm) 84.00" (213.4 cm) 7.00" (17.8 cm) 95.00" (241.3 cm) Sash Frame to affle FRONT 2.50" (6.4 cm) dia. Ser Service Fixture Supply Holes SIDE ontact Labconco at 800-821-5525 or 816-333-8811 or visit www.labconco.com for detailed AutoAD drawings. 5

Dimensional Data 8', 10', 12' and 16' Protector XL Floor-Mounted Laboratory Hoods with horizontal-sliding sashes A* * * D* E* F* G* H* 8' Hood 9700801 96.00 86.25 24.00 39.20 30.00 48.00 22.50 43.25 (243.8) (219.1) (61.0) (99.6) (76.2) (121.9) (57.2) (109.9) 9700803 96.00 86.25 24.00 45.20 36.00 48.00 22.50 43.25 (243.8) (219.1) (61.0) (114.8) (91.4) (121.9) (57.2) (109.9) 9700805 96.00 86.25 24.00 57.20 48.00 48.00 22.50 43.25 (243.8) (219.1) (61.0) (145.3) (121.9) (121.9) (57.2) (109.9) 4.91" (12.5 cm) 2.27" (5.8 cm) 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars TOP 8', 10', 12' 10.53" (26.7 cm) D Single Point Internal Junction ox 10' Hood 9700901 120.00 110.25 35.00 39.20 30.00 50.00 28.50 55.25 (304.8) (280.0) (88.9) (99.6) (76.2) (127.0) (72.4) (140.3) 9700903 120.00 110.25 35.00 45.20 36.00 50.00 28.50 55.25 (304.8) (280.0) (88.9) (114.8) (91.4) (127.0) (72.4) (140.3) 9700905 120.00 110.25 35.00 57.20 48.00 50.00 28.50 55.25 (304.8) (280.0) (88.9) (145.3) (121.9) (127.0) (72.4) (140.3) 12' Hood 9701001 144.00 134.25 41.00 39.20 30.00 62.00 34.50 67.25 (365.8) (341.0) (104.1) (99.6) (76.2) (157.5) (87.6) (170.8) 9701003 144.00 134.25 41.00 45.20 36.00 62.00 34.50 67.25 (365.8) (341.0) (104.1) (114.8) (91.4) (157.5) (87.6) (170.8) 9701005 144.00 134.25 41.00 57.20 48.00 62.00 34.50 67.25 (365.8) (341.0) (104.1) (145.3) (121.9) (157.5) (87.6) (170.8) 16' Hood 9716001 192.00 182.25 24.00 39.20 30.00 48.00 46.50 91.25 (487.7) (462.9) (61.0) (99.6) (76.2) (121.9) (118.1) (231.8) 9716003 192.00 182.25 24.00 45.20 36.00 48.00 46.50 91.25 (487.7) (462.9) (61.0) (114.8) (91.4) (121.9) (118.1) (231.8) 9716005 192.00 182.25 24.00 57.20 48.00 48.00 46.50 91.25 (487.7) (462.9) (61.0) (145.3) (121.9) (121.9) (118.1) (231.8) *Inches (centimeters) Four ollars 4.91" (12.5 cm) 2.27" (5.8 cm) F 12.81" (32.5 cm) ID Exhaust ollars 2.50" (6.4 cm) dia. Service Fixture Supply Holes F 12.81" (32.5 cm) ID Exhaust ollars 10.53" (26.7 cm) D Single Point Internal Junction ox TOP (16') A Fluorescent Lights D 4.19" (10.6 cm) Front Access Panel (one on each side) 15.00" 7.00" (17.8 cm) 68.15" (173.1 cm) Viewing Height to Floor H Max Opening G Door Width Service Fixture (one on each side) 115 Volt, 20 Amp Duplex Electrical Receptacle 2.00" (5.1 cm) Interior Access Panels Upper abinet Lower ase E 77.00" (195.6 cm) 36.00" (91.4 cm) 84.00" (213.4 cm) 95.00" (241.3 cm) Sash Frame to affle FRONT SIDE ontact Labconco at 800-821-5525 or 816-333-8811 or visit www.labconco.com for detailed AutoAD drawings. 6

Accessories Standard Service Fixture Kits For mounting on the left or right side of the Protector XL Floor-Mounted Laboratory Hood. Each kit includes one remotely-controlled service fixture with valve and 0.25" diameter tubing, color-coded fixture knob and color-coded hose connector. Inlet tubing is not included. Shipping weight 4 lbs. (1.8 kg) atalog # Kit Tubing Valve Knob/onnector Max. Max. Working olor Flow Rate Pressure ** 9808300 old Water (W) opper rass Green 3.5 GPM (13.2 LPM) 40 psi 9808400 Air (AIR) opper rass Orange 23.7 FM 40 psi 9808500 Vacuum (VA) opper rass Yellow 8.6 FM 14.7 psi 9808700 Gas (GAS) rass rass lue 29.0 FM (441 TU/sec) 40 psi 9808800 Argon (ARG) opper rass Gray 20.2 FM 40 psi 9808900 Hot Water (HW) opper rass Red 3.5 GPM (13.2 LPM) 40 psi 9809100 Deionized/ Stainless Nickel-Plated & White 3.5 GPM (13.2 LPM) 40 psi Distilled Water (DI) Steel Stainless Steel 9809200 Steam (STM) opper rass lack 0.5 LM/min 40 psi 9809300 Nitrogen (NIT) opper rass rown 24.1 FM 40 psi 9809700 * Oxygen (OXY) opper rass with Light Green 22.6 FM 40 psi Oxygen- ompatible Lubricant old Water Gooseneck Fixture Kits For mounting on the left or right side of any Protector XL Floor-Mounted Laboratory Hood with 30" interior depth. Each kit includes one remotely-controlled gooseneck with brass valve and 0.375" diameter copper tubing and green fixture knob. Inlet tubing is not included. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Shipping Weight 10 lbs. (4.5 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** 9827900 old Water (W) For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi Gooseneck Depths of 24" to 30". Includes green epoxy-coated brass rigid/swivel gooseneck. Hot and old Water Mixing Gooseneck Fixture Kit For any Protector XL Floor-Mounted Laboratory Hood with interior depth of 24" to 30". Each kit includes one remotelycontrolled, white epoxy-coated, brass rigid/swivel gooseneck with brass valve and 0.25" diameter copper tubing, one green fixture knob and one red fixture knob. Inlet tubing is not included. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Shipping weight 11 lbs. (5.0 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** 9828000 Hot (HW) and old Water (W) For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi Mixing Gooseneck Depths of 24" to 30" Deionized/Distilled Water Gooseneck Fixture Kit For mounting on the left or right side of any Protector XL Floor-Mounted Laboratory Hood with 30" interior depth. Each kit includes one remotely-controlled, gray PV rigid gooseneck with stainless steel valve and 0.25" diameter tubing and white fixture knob. ontact Labconco for ordering information on Gooseneck Fixture Kits for Protector Hoods with interior depths of 36" or 48". Inlet tubing is not included. Shipping weight 10 lbs. (4.5 kg) atalog # Kit Description Max. Flow Rate Max. Working Pressure ** 9853400 Deionized/Distilled Water For Hoods with Interior 3.5 GPM (13.2 LPM) 40 psi (DW) Gooseneck Depths of 24" to 30" GPM=gallons per minute LPM=liters per minute FM=cubic feet per minute TU/sec=ritish thermal unit per second LM/min= pounds mass per minute *WaterSaver **Maximum allowable pressure is 200 psi with a working pressure of 40 psi. Requires 1.375" dia. drill hole in liner. 7

Accessories 4852600 Side-Mount Oval Polypropylene upsink Mounts on side wall of Protector XL Floor-Mounted Hoods. 6" x 3" cupsink. 1.5" NPSM thread. Requires a 1.875" diameter drilled hole in liner. Shipping weight 4 lbs. (1.8 kg) National Pipe Straight Mechanical Duplex Electrical Receptacle Kits For mounting in left or right side of any 4', 5', 6', 7' or 8' Protector XL Floor-Mounted Laboratory Hood. Each kit includes duplex electrical receptacle, wiring, junction box and receptacle cover plate. ontact Labconco for ordering information on Duplex Electrical Receptacle Kits for Protector Hoods with widths of 10', 12' or 16'. atalog # Kit For Hood with exterior widths: Shipping Wt. lbs./kg 9851100 115 volts, 20 amps A 4', 5', 6' and 8' 4/1.8 9851500 115 volts, 20 amps A, GFI 4', 5', 6' and 8' 4/1.8 9854200 230 volts, 20 amps A 4', 5', 6' and 8' 4/1.8 Guardian 1000 Digital Airflow Monitor Kits Monitor and alert the operator to low airflow conditions. Include face plate with circuit board, electrical power pack, airflow hose and flow hose adapter. LD displays actual airflow in fpm or m/sec from 0 to 999 fpm (0 to 5.0 m/s). Audible/visual alarm alerts user to sustained low velocity condition. alibration instructions displayed on LD. LED lights display red for alarm, yellow for caution, green for normal. Include temperature-compensated sensor, external alarm, night setback and alarm mute functions. UL and E listed. For installation in a factory-prepared cutout on upper portion of right fixture panel. ontact Labconco for ordering information on an optional factory-prepared RS-485 port for Modbus RTU communication. atalog # Description For use with: Shipping Wt. lbs./kg 9743211 115 volts, 60 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 9743212* 230 volts, 50 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 Guardian 500 Airflow Monitor Kits Monitor and alert the operator to low airflow conditions. Include face plate with circuit board, electrical power pack, vinyl tubing and airflow tube adapter. From the monitor s face plate, the user can easily select and calibrate a setpoint between 30 and 250 fpm using a velocity meter and a screwdriver. A green LED glows to indicate safe when airflow is greater than the low setpoint. A red LED flashes to indicate low when airflow is below the low setpoint. An amber LED flashes when the sash is raised above the maximum safe working opening. An audible alarm sounds (and can be muted) when under low and sash high conditions. Include night setback, external alarm and alarm mute functions. For installation in a factory-prepared cutout on upper portion of right fixture panel. atalog # Description For use with Protector Hood: Shipping Wt. lbs./kg 9743213 115 volts, 60 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 9743214* 230 volts, 50 Hz Protector XL Floor-Mounted Laboratory Hood 6/2.7 Labconco orporation 8811 Prospect Avenue Kansas ity, Missouri 64132-2696 800-821-5525 816-333-8811 FAX: 816-363-0130 E-Mail: labconco@labconco.com Home Page: www.labconco.com ontact Labconco at 800-821-5525 or 816-333-8811 for ordering information on ceiling enclosure and rear finish panel kits, fire extinguishers, explosion-proof lighting, solid epoxy floors, tissue screens and distillation grids; and for blower sizing assistance. 2012 by Labconco orporation Printed in the U.S.A. Product design subject to change without notice. 2-56-1/12-James-1M-R1