Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors SLV Series Clear PVC SLV Series Sized for a Range of Conductors BY Series a PVC Boot and Locking Insulator Fit a range of mains and taps. Enables safe and time-saving installation. Perfect for multiple installation types. Both ensure a fully insulated connection. The connector stays on until removal is necessary. Capacitor Controls RB 210-8 SL SLV 42-212 BY 320 for Insulated Lighting Mechanical Connectors CAT. NO. RB Series Rubber Insulated Conductor Range RB 210-8 SL Main 1/0 max., Tap #12 #8 RB 210-8 SS Main 1/0 max., Tap #12 #8 RB 6240 SL Main 2/0 #14, Tap #14 #6 SLV Series Clear PVC Encapsulated SLV 240-24 Main (2) 4/0 #6, Tap (2) #14 SLV 42-212 #12 #2 BY Series PVC Insulated BY 320 #14 2/0 NOTE: For oxide-inhibitor option, add -C suffix to the catalog number. 53
Lighting Mechanical Connectors Lighting Compression Fuse and Non- Kits In-Line Everything you need for copper connections to roadway lighting. Copper In-Line Fuse Kits include Flood-Seal housing, fuse clips, silicone lubricant and instruction sheet. Fuse is not included. Fuse Kits accept nonglass standard cartridge fuses of 13 32" diameter and 1 1 2" length. Copper In-Line Non- Kits include Flood-Seal housing, connecting link, silicone lubricant and instruction sheet. Breakaway Design Kits separate under tension so wires don t break. for Compression In-Line Fuse Kits Single Housing Twin Housing CU Wire Size CAT. NO. CAT. NO. Str. Sol. Installation Tool SLK SLT 6 #14 #10 #14 #8 T&B WT111M, C Die or Equal SLK 6 SLT 6 SLK SLT 6 #8 #6 #6 T&B TBM20S, Blue Die or Equal SLK SLT 2 #2 T&B TBM20S, Gray Die or Equal SLK 2 SLT 2 SLK SLT 2 #2 T&B TBM20S, Brown Die or Equal SLK 2 SLT 6 #6 Side #2 Side Single Housing Twin Housing CU Wire Size CU Wire Size CAT. NO. CAT. NO. Str. Sol. Installation Tool Str. Sol. Installation Tool #14 #10 #14 #8 T&B WT111M, C Die or Equal #2 T&B TBM20S, Gray Die or Equal SLK 6 2 SLT 6 2 #8 #6 #6 T&B TBM20S, Blue Die or Equal #2 T&B TBM20S, Brown Die or Equal for Compression In-Line Non- Kits Single Housing Twin Housing CU Wire Size CAT. NO. CAT. NO. Str. Sol. Installation Tool SDT 6 #14 #10 #14 #8 T&B WT111M, C Die or Equal SDK 6 SDT 6 #8 #6 #6 T&B TBM20S, Blue Die or Equal #2 T&B TBM20S, Gray Die or Equal SDK 2 SDT 2 #2 T&B TBM20S, Brown Die or Equal SDK 2 SDT 6 #6 Side #2 Side Single Housing Twin Housing CU Wire Size CU Wire Size CAT. NO. CAT. NO. Str. Sol. Installation Tool Str. Sol. Installation Tool #14 #10 #14 #8 T&B WT111M, C Die or Equal #2 T&B TBM20S, Gray Die or Equal SDK 6 2 SDT 6 2 #8 #6 #6 T&B TBM20S, Blue Die or Equal #2 T&B TBM20S, Brown Die or Equal NOTE: For 60A options, add -60 suffix to the catalog number. For larger wire sizes, please consult your Thomas & Betts representative. 54 8155 T&B Boulevard Memphis TN 38125 800.326.5282 utility.tnb.com PG-CG-HOM-0909
Lighting Mechanical Connectors Breakaway Single-Pole and Double-Pole Street Light Kits Versatile kits for roadway lighting fixtures, flood and area lighting fixtures and power distribution systems. All Kits include line- and load-side housings, metal fuse sockets, assembly dowel, lubricant, wiper and installation instructions. Fuse is not included. Fuse Kits accept non-glass standard cartridge fuses of 13 32" diameter and 1 1 2" length. Watertight and Easy to Install Individual Fusing Breakaway-Style Fuse Holder Readily Identifiable Problem Area Standards Compliant Doesn t require tape, compound or heat source for fitting. Enables separation of kit without de-energizing complete circuit. Eliminates risk of electrical shock. Exposed current carrying components are all contained in harmless load side of the kit. Simplifies maintenance. CSA Certified. Capacitor Controls Line-Side Housing Crimp-On Fuse Holders Load-Side Housing Type 65 U Type D 65 U Line-Side Housing Receptacle Load-Side Housing Receptacle Line-Side Housing Receptacle Load-Side Housing Receptacle Crimp-On Fuse Sockets Assembly Dowel Crimp-On Fuse Sockets Assembly Dowel for Type 65 Breakaway Single-Pole In-Line Conductor CAT. NO. AWG Material* 65 U Copper 65 LC or #2 Copper * Available in aluminum. Fuse not included with kit. Do NOT use glass fuses. NOTE: Electrical rating for 600V,.10 30A, 13 32" x 1 1 2" fuse. Maximum overall length: 7 3 4" installed, diameter: 1 1 8". Double-Pole In-Line Conductor CAT. NO. AWG Material* D 65 U Copper D 65 LC or #2 Copper * Available in aluminum. Fuse not included with kit. Do NOT use glass fuses. NOTE: Electrical rating for 600V,.10 30A, 13 32" x 1 1 2" fuse. Maximum overall length: 7 3 4" installed, diameter: 2 5 16". 55
Lighting Mechanical Fuse and Disconnect Kits Y-Type Ideal for heavy-duty applications. Aluminum and Copper Y-Type Fuse Kits include Flood-Seal housing, fuse clips, two aluminum lugs, hardware, silicone lubricant and instruction sheet. Fuse is not included. 9 3 4" max. Aluminum and Copper Y-Type Disconnect Kits include Flood-Seal housing, fuse clips, connecting link, two aluminum or copper lugs, hardware, silicone lubricant and instruction sheet. 1 5 8" Dual-Rated Approved for a wide range of aluminum or copper conductors. Some Fuse Kits can even accept a 60A fuse. for Y-Type Kits 600 Volt, 30 Amp Max. 600 Volt, 30 Amp Max. Wire Size / Installing CAT. NO. Stranded Non Dies FYA-6 #6 52, BG, 243, 5 8 Wire Size / Installing CAT. NO. Stranded Non Dies DYA-6 #6 52, BG, 243, 5 8 FYA-4 52, BG, 243, 5 8 FYA-2 #2 (Aluminum 52, BG, 243, 5 8 FYA-1/0 1/0 52, BG, 243, 5 8 FYA-2/0 2/0 58, 297, 245, 5 8-1 DYA-4 52, BG, 243, 5 8 DYA-2 #2 Non- (Aluminum 52, BG, 243, 5 8 DYA-1/0 1/0 52, BG, 243, 5 8 DYA-2/0 2/0 58, 297, 245, 5 8-1 FYC-8 #8 1 4, 6, TC, 21 DYC-8 #8 1 4, 6, TC, 21 FYC-6 #6 J, 7, TE, 24 FYC-4 5 16, 8, TP, 29 3 FYC-2 #2 (Copper 8, 10, TL-TN, 33 FYC-1 #1 3 8, 11K TB, 37 FYC-1/0 1/0 1 2, 12, TQ, 42 FYC-2/0 2/0 9 16, 13, TS, 45 DYC-6 #6 J, TE, 24 DYC-4 5 16, 8, TP, 29 Non- (Copper DYC-2 #2 3 8, 10, TL-TN, 33 DYC-1 #1 3 8, 11K TB, 37 DYC-1/0 1/0 1 2, 12, TQ, 42 DYC-2/0 2/0 9 16, 13, TS, 45 NOTE: If fixture or tap wire is aluminum, add the following suffixes to the catalog number: -2A for 14 10 Stranded or 12 8 Solid. For example, FYC 1/0-2A. -3A for 8 6 Stranded or 6 4 Solid. For example, FYA 1/0-3A. 56 8155 T&B Boulevard Memphis TN 38125 800.326.5282 utility.tnb.com PG-CG-HOM-0909
Lighting Compression Fuse and Disconnect Kits YY-Type Breakaway design prevents wire breakage. YY-Type Fuse Kits include Flood-Seal housing, fuse clips, silicone lubricant and instruction sheet. Fuse is not included. Fuse Kits accept non-glass standard cartridge fuses of 13 32" diameter and 1 1 2" length. YY-Type Disconnect Kits include Flood-Seal housing, connecting link, silicone lubricant and instruction sheet. Breakaway Design Kits separate under tension so wires don t break. for YY-Type Kits Aluminum / CAT. NO. Non Main Tap YFA 8 #8 YFA 6 #6 YFA 4 YFA 2 #2 YFA 1/0 1/0 YFA 2/0 2/0 YDA 8 #8 YDA 6 #6 YDA 4 Non- YDA 2 #2 YDA 1/0 1/0 YDA 2/0 2/0 Copper / CAT. NO. Non Main Tap YFC 8 #8 YFC 6 #6 YFC 4 YFC 2 #2 YFC 1/0 1/0 YFC 2/0 2/0 YDC 8 #8 YDC 6 #6 YDC 4 Non- YDC 2 #2 YDC 1/0 1/0 YDC 2/0 2/0 NOTE: 600V, 30A fuse not included. kits accept standard cartridge fuse with 13 32" diameter, 1 1 2" length, non-glass type. 57
Lighting Mechanical Fuse and Disconnect Kits In-Line In-line mechanical kit options for aluminum or copper conductors. In-Line Fuse Kits include Flood-Seal housing, fuse clips, silicone lubricant and instruction sheet. Fuse is not included. Fuse Kits accept non-glass standard cartridge fuses of 13 32" diameter and 1 1 2" length. SLK 22-60 M, SLK 102-60 M and SLK 1010-60 M Fuse Kits can also accept a 60A fuse measuring 2 1 4" long. In-Line Non- Kits include Flood-Seal housing, connecting link, silicone lubricant and instruction sheet. SDT M SDK 1010 M Dual-Rated Approved for a wide range of aluminum or copper conductors. Some fuse kits can even accept a 60A fuse. for Lighting Mechanical Fuse and Disconnect Kits / Conductor Range (Al/Cu) CAT. NO. Non Stranded Solid In-Line Kits SLK M 12, 10, 8, 6, 4 12, 10, 8, 6,4 SLT M 12, 10, 8, 6, 4 12, 10, 8, 6,4 #12, #10, #8, #6, #12, #10, #8, #6, SDK M 12, 10, 8, 6, 4 12, 10, 8, 6,4 Non- SDT M 12, 10, 8, 6, 4 12, 10, 8, 6,4 In-Line Variable-Range Kits SLK 22 M #2 #14 #2 #14 SLK 102 M 1/0 #2 #2 #14 SLK 1010 M 1/0 #2 1/0 #2 SLK 22-60 M* #2 #14 #2 #14 SLK 102-60 M* 1/0 #2 #2 #14 SLK 1010-60 M* 1/0 #2 1/0 #2 SDK 22 M Non- #2 #14 #2 #14 SDK 102 M Non- 1/0 #2 #2 #14 SDK 1010 M Non- 1/0 #2 1/0 #2 Indicates twin housing. * 60A fuse max. 60A fuses are 2 1 4" long. NOTE: 600V, 30A fuse not included. kits accept standard cartridge fuse with 13 32" diameter, 1 1 2" length, non-glass type. 58 8155 T&B Boulevard Memphis TN 38125 800.326.5282 utility.tnb.com PG-CG-HOM-0909
Lighting Mechanical Fuse and Disconnect Kits Y-Type Standard and mechanical run compression tap kits for your roadway lighting jobs. YDU Mechanical Y-Type Fuse Kits include Flood-Seal housing, fuse clips, dowel and silicone lubricant. Fuse is not included. Fuse Kits accept non-glass standard cartridge fuses of FYU 2 13 32" diameter and 1 1 2" length. EPDM Flood-Seal Housing Capacitor Controls Breakaway Design Re-Enterable Kits separate under tension so wires don t break. Enables sectionalizing. Matching Ampacity Rating Run or feeder lugs have the same ampacity rating as the cable, up to 2/0. Y-Type Mechanical Run Compression Taps Use a 1 8" Hex Wrench Just one tool needed for easy installation. for Lighting Mechanical Fuse and Disconnect Kits Y / Conductor Range (Al/Cu) CAT. NO. Non Main Tap Y-Type Disconnect Kits Y-Line Mechanical Run Compression Kits FYU M DYU M Non- #14 #2 #12 FYU 6 FYU 2 #14 #2 #2 DYU 6 Non- Non- DYU 2 Non- #2 for Lighting Mechanical Fuse and Disconnect Kits YY YY-Type Disconnect Kits / CAT. NO. Non Conductor Range (Al/Cu) YFU M #14 Cu YDU M Non- #14 #2 AI NOTE: 600V, 30A fuse not included. kits accept standard cartridge fuse with 13 32" diameter, 1 1 2" length, non-glass type. 59