Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

Similar documents
Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

User Manual 1KVA-5KVA INVERTER / CHARGER

R series solar charger inverter 1000W to 6000W

Solar Hybrid Inverter SP Brilliant Series

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

MERU Solar Off-Grid Inverters

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Uninterruptible Power System

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

1. Important Safety Warning

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Solar Charge Controller

SAFETY WARNINGS AND GUIDELINES

S150,S300 Series Pure Sine Wave Inverter User s Manual

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

USER S MANUAL SOLAR POWER INVERTER KW-6KW

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

SCC-MPPT Solar Charge Controller

Uninterruptible Power System

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

Pure Sine Wave Inverter Charger

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Solar Hybrid Inverter SP Initial Series

Low Frequency Inverter. User Manual

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

Uninterruptible Power System

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Solar Inverter 3kW-8kW Inverter (off-grid)

PureSine 150/300 Pure Sine Wave Inverter User s Manual

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

User Manual V1.0 MaxiFlex 3000

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

On-line, Single Phase, Double Conversion UPS

User Manual 1KVA-5KVA INVERTER / CHARGER

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

PVES Series User Manual User Manual Shenzhen Pvinergy Technologies Co., Ltd

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

PI1500X Power Inverter User s Manual

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

General Precautions. Personnel Precautions

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Pure sine wave charger inverter Product Manual

General safety and installation information.

USER MANUAL ONLINE UPS

OWNER S MANUAL POWER INVERTER

USER MANUAL DN / DN

User Manual Solar Charge Controller 3KW

Solar off-grid Inverter. SP Junior Series. User Manual

BS20 BATTERY CHARGER For lead-acid batteries

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

Solar Hybrid Inverter SP Efecto Series

User Manual 200Ah INVERTER / CHARGER

Informer Compact Series

Liebert GXT MT+ User Manual VA Installer/User Guide

Solar Hybrid Inverter SP Efecto Series

K50. Technical Sheet

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

Off Grid Solar Inverter. LVS 50M User Manual

Installation and Operation Back-UPS BX550CI-CN

3000W POWER INVERTER. User Manual

User Manual. Solar Charge Controller 3KW

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Installation and Operation Manual Back-UPS BX1100CI-CN

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

USER MANUAL MPS 1-5KW SERIES

Transcription:

Sine Wave Solar UPS Owner s Manual KSU 1024S, KSU 2048S Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology. Please read this guide carefully before installing the product. Should you have any queries & suggestions please call on us. We will be happy to provide the assistance that you are looking for. We wish you years of joyful homemaking with the NON STOP UPS & look forward to a great association with you.

Contents 1. Overview.. 4 2. Applications 4 3. Key features.. 5 4. Technical Specifications 6 5. Physical Description. 8 6. Safety Instructions 12 7. Installation.. 13 8. Load Chart 14 9. Trouble Shooting. 15 10. Error Messages 16 11. Warranty card. 17

Over view A UPS is an electrical apparatus which is interfaced between the electric network and the appliances that need to be protected from power uncertainties like power outages, over voltages, under voltages, power line disturbances and surges. The UPS have the battery source which gets charged when the mains power is available and provides the back up power from the battery when the mains is not available, ensuring uninterruptible power supply. The intelligent Sine wave Solar UPS with state of the art technology provides following key functionalities: When the solar power and mains power are available, battery will be charged by solar panel. If the battery voltage is too low, then it will also charge the battery through mains power. When the mains power and solar power are available, the load will be powered by Solar power. If the load requirement is more than the available solar power then the battery will supply the additional load. When solar power is not available, the grid power will charge the battery & supply the load like any conventional UPS. It is compact & lighter than any other UPS in its class. Applications Power back up for your home Domestic computer and its peripherals Emergency power systems Photography Small water pumps and all motor based small applications Television, Fans & Tube lights Professional applications where waveform is critical

Key Features MCU control guarantees high reliability Pure Sine wave output Compact and light weight Simple & easy installation High efficiency & longer back up time Intelligent charging ensuring more battery life Normal & Computer mode operation of the UPS 10% more solar energy is harvested by using MPPT solar charger Auto priority logic to charger from both mains & solar simultaneously. No load sleep: If the load is less than 20W, the inverter will go to automatic sleep and save power Auto wakeup : Inverter will switch on automatically when the battery is charged by solar to predetermined level. Phase reversal protection Overload protection & auto recovery Short circuit protection Liquid crystal display for UPS status monitoring

Technical Specification Mains Input Model KSU 1024S+ KSU 2048S+ Nominal input : 230V AC, 50 Hz Input voltage lower cut off o Computer mode : 175 V AC o Normal mode : 125 V AC Input voltage higher cut off : 270 V AC (configurable) Input connection : 3 pin plug (15A) Output Model NS 1024S+ NS 2048S+ Inverter Mode Out put voltage (VAC) : 208 230 Out put power : 1000/1000 2000/2000 (VA/Watt) Out put frequency (Hz) : 49.0 51.0 Out put voltage wave form : Pure Sine wave Out put connection : 6A outlet 15A outlet Efficiency ( %) : 80% 82% Mains Mode : Out put voltage (VAC) Same as input Efficiency ( %) : >96% Transfer time : <10 milliseconds LCD indication : Status of UPS/Solar charger, Solar generated power Audible Alarm Battery low Mode changeover Nose Level : <50 db Battery voltage (V) : 24 48 Battery capacity : 300X2 300X4 Recommended (AH) Typical Low battery Alarm : 22.0 44.0 Voltage (V) Typical Shut down battery voltage (V) : 21.6 43.2

MPPT Solar charger (Intelligent maximum power point tracking (MPPT) technology) Model NS 1024S+ NS 2048S+ Battery charging current (A) Maximum solar input power(w) Peak charger efficiency Max Solar open circuit voltage (V) : 40 40 : 1000 2000 : 98% : 85 120 Protection Physical Lightening, battery over voltage, battery under voltage, battery wire removal, out put short circuit, over load, phase reversal. 1024S+ Dimension : 355 144 215 mm Net weight: 6.5Kg. 2048s+ Dimension : 478 191 339 mm Net weight: 16Kg. Environment Humidity : 0 90 % RH Operating temperature: 0 45 ºC Note: Specifications are subject to change without prior notice.

Physical Description Below Figure shows the 3D view of the Solar UPS. The product has the metallic enclosure. Adequate cooling fans are provided for thermal management. Front panel has a LCD to indicate the instantaneous status of the product. Front panel switch is provided to select different operating modes. Front panel

LCD PART The first line is digital section,and is consisted of two small numeric sections and the related unit section on the right side. It is used to display the numerical value of the certain item on the second line. The second line is the item section, includes input, solar, battery, output, load and temperature etc. The third line is the graphic section which has the load (left) and battery capacity (right) displayed in graphics. The failure icon will be displayed when there is a failure. The fourth line is the status section, and is the area of machine status in English. The detail is descript in the below LCD displayed status table. LED PART I Line status LED: When Line is OK,the LED light on. PV Panel LED: When PV panel is OK, the LED light on. Battery status LED:When battery voltage is OK, the LED light on, when battery low,the LED blink. LED PART II Inverter status LED: When Inverter takes load, the LED light on. Bypass status LED: When Bypass takes load, the LED light on. Fault status LED:When UPS fail, the LED light on.

BUTTON PART Button function description Power On button When there is only battery connected, press this button to power on the solar UPS. Function button Not used. Query button Short press,it will in turn shows the items in the second row of display. Long press, it goes to rotational shows and the items will alternately show every 2s and the turns are: Input, Solar, Battery, Output, Load and Temperature. When long pressing the button again, it will turns to display output and PV generated power. LCD displayed status : Information on LCD MNS ON MNS OFF MPPT ON MPPT OFF MPPT FLT INV ON UPS BPS CHG ON CHG OFF UPS OFF UPS FAIL LOAD HI Meaning Power supply from mains is available. Power supply from mains is not available. Solar power is available Solar power is not available MPPT charger is not functioning The Inverter is functioning. The Inverter is OFF, load is take by mains Battery is getting charged by mains. Battery is not getting charged by mains. UPS is in sleep mode and not goes to Inverter mode during mains power is off. UPS is not working. LCD displays an error code. UPS is over loaded. It restarts for 6 times with an alarm. If the load is reduced with in this period it will restore normal functioning. Else, It will shut down with a trip message to protect itself from continuous overloading.

Information on LCD OP SHORT Meaning UPS output is short circuited. It will shut down with a trip message to protect itself from short circuit. Switch: Computer mode Sleep mode Normal mode The functions of each mode are given below : Switch position Type of mode Description Top (=) Computer mode UPS switches to Inverter mode when the mains voltage goes below 175 V and above 270V. Middle(o) Sleep mode Mains ON : UPS is in bypass mode & battery will be charging. Mains OFF : UPS will be idle and battery will be charging by Solar. Bottom ( ) Normal mode UPS switches to Inverter mode when the mains voltage goes below 125 V and above 270 V Rear panel

Name FUSE AC MAINS UPS OUT BATTERY POS BATTERY NEG BAT CHARGE NORM Description Connected at mains input & protects the UPS from electrical surges. Always use the rated fuse. Mains input to UPS. Connected through the power cord with 15 A, 3 pin plug. The output of the UPS for load. The positive (RED) terminal is extended from the UPS to connect to the positive end of the battery. The negative (BLACK) terminal is extended from the UPS to connect to the negative end of the battery. Normal battery charging current. Set when 120 AH or less capacity battery is used.

Name BAT CHARGE HIGH BAT CHARGE ENABLE BAT CHARGE DISABLE SOLAR IN POS SOLAR IN NEG UPS OFF Description High Battery charging current. Set when 150AH or more capacity battery is used. To enable the charging from mains To disable the charging from mains Connection to positive terminal of Solar module. Connection to negative terminal of Solar module. Press this switch momentarily for 2 3 seconds to completely shutdown the solar UPS. Condition: PV NG & Mains off & front panel switch is in sleep mode.

Safety Instructions Always disconnect the battery cables of the UPS only after turning the UPS into sleep mode & disconnecting the UPS from AC mains. Connecting the battery terminals usually create an arc. This is normal. Connect the battery terminals firmly to ensure no loose contacts. Follow battery manufacturer's instructions carefully. Do not allow the UPS to be exposed to flammable liquids, rain, excessive heat or direct sunlight. Connect the UPS to a grounded power outlet. Always use rated fuse. While going out on vacations keep the UPS in sleep mode & Solar module connected to keep the battery in charged condition. Place the UPS in an adequate airflow and dust free area. Maintenance must be performed by a qualified personnel. Failure to do so could result in electric shock. Use tools with insulated handles during installation and maintenance to avoid personnel injury.

Installation Package content: Solar UPS one unit ( with battery cable & Mains cord) Owner's Manual with Warranty card Spare fuses Battery interconnect cable (for more than one battery option) Installation Procedure Turn the front panel switch to sleep mode Connect the positive and negative terminals of the battery to the respective battery cable of the UPS. Connect the positive and negative terminals of the solar panel to the respective terminals of the SOLAR IN located at rear panel. Connect the mains cord of the UPS to 15 A mains outlet. It is recommended that before connecting to the load charge the battery for a minimum period of 8 hours. Plug your peripheral equipment / appliances to "UPS OUT" Turn the front panel switch to Normal mode. Turn it to computer mode if computers are part of the load. Ensure that the connected load is with in the rated limit. Warning!: Ensure that battery connections are made with correct polarity. Ensure that Solar panel connections are made with correct polarity. Ensure that Solar terminals are not shorted while MPPT is ON. Failed to do so may cause damage to UPS.

Load Chart Typical NS 1024S+ NS 2048S+ Appliance Load A B A B Fan 75W 6 4 12 8 Tube light 40W 7 5 13 10 Television 125W 1 0 2 0 Computer 150W 1 3 2 6 Printer 40W 0 1 1 2

Trouble shooting Sl.No. Problem Remedy 1 AC mains not 1) Check the power from the mains available to the UPS socket. 2) Check the fuse at the rear. If the fuse has blown, change it with specified rated fuse. 2 Inverter not working 1) Battery is low. 2) Battery terminals are loose. Tight them. 3) Front panel switch is in sleep position. Turn it to Normal or Computer position. 3 Inverter intermittently trips UPS might be overloaded. Reduce the load, turn the front panel switch, then it resumes to the normal operation. 4 Battery low Recharge the battery for minimum 8 hours to restore 90 % of the capacity 5 Battery not charging 1) Battery terminals are loose. 2) Check the distilled water level. If not ok, fill it. 6 Less back up time 1) Check the distilled water level. If not ok, fill it. 2) Charge the battery with mains for minimum 8 hours. If still the back up time is less, check the battery by authorized service personnel. 7 The solar panel is connected but the LCD shows SOLAR OFF 1) Check the solar panel to UPS cable Connection. 2) Check the solar panel is clean and uncovered. Note: If the problem still persists call the service centre.

Error Messages On rear occasions, you may notice certain error codes on the top right side of LCD. These error codes may be interpreted as below. Shut down the UPS immediately & call the service centre. Error code Meaning 04 Internal temperature of UPS is very high. 02 Output short. 01 Output overload timeout. 16 Inverter fail. 32 Booster fail. 08 Over Charge.

Customer Name: Address: Warranty Card UPS Model: UPS Sl. No. Solar panel (Make, Model & Sl No) Battery (Make, Model & Sl No) Invoice No & Date Dealer s Name, Address & Contact No. Dealer s stamp & Signature Manufactured By: The End