Exhaust air diffuser HPKH + Plenum box ATTS

Similar documents
Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Conical diffuser KHAA TECHNICAL DATA

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

CTVK Supply air diffuser

KSOF Fire damper valve

KTI Supply air valve. Product Facts. Product code example. Quick Selection

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Nozzle air diffuser DYSB

Plenum box ATTD TECHNICAL DATA

KSOM Control exhaust valve

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

CornerAir. CornerAir. Active chilled beam

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

ACTIVENT System. Specifications. Product code example ACTA

TBV - Terminal Unit. Halton TBV. Terminal Unit

SINGLE DUCT TERMINAL UNITS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

EXCa. Exhaust register

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Ceiling swirl diffusers

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

OPTIVENT Housing HVSA, HVSL

Ceiling swirl diffusers

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

series RVV Variable flow rate controllers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

Regulation and shut-off damper SPB and SPC

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

CONSTANTFLOW Volume Flow Controllers

CHILLED BEAM IQ STAR WEGA II

Ceiling swirl diffusers with perforated face plate

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

Ceiling swirl diffusers

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

DATASHEET PRODUCT CODE EXAMPLE:

Kitchen exhaust fan GLEB

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

ROOFMASTER STEF-ATEX ROOF FAN

Aircell Polymer Range

ROOFMASTER STEF-HT ROOF FAN

Zest Iris Duct Dampers

Powder coating RAL, Satin anodized 11µm. Powder coated extruded aluminium. With mounting brackets on SPS plenum box. Fixed mounting on SPB plenum box

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers with perforated face plate

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

Square supply diffuser

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

ILO, OLO, OLE and OLOi

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

REK, LEK, ROK and LOK

Pressure control damper ERPA

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Total comfort control

WALL VENTILATION GRILLES CBP

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

Slot diffusers, Round duct diffusers. IMP Klima

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

ROOF FAN ROOFMASTER STEC

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

LØV-R. Orion-Opus. Square supply diffuser

J L I e x h a u s t h o o d

Fire dampers ETCE and ETCS TECHNICAL DATA

DAC - Conical Diffuser. Halton DAC. Conical diffuser

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Ceiling air diffuser PASSCLEAN

Transcription:

Exhaust air diffuser HPKH + Plenum box ATTS The HPKH is a quiet, ceiling-mounted exhaust air diffuser. The diffuser has an almost completely perforated diffuser plate. The slot height of the diffuser can be set at 0 or 12 mm. Fixed to the diffuser body with magnets, the diffuser plate is easy to open. The HPKH exhaust air diffuser is also available without the plenum box. Quick Selection HPKH with 0 mm slot, 1:2 plenum box ATTS (50 Pa) Diffuser Connection ATTS Air flow l/s at sound level HPKH- inlet mm outlet mm 25 db(a) 30 db(a) 35 db(a) 160-4 125 160-40 - 160-6 125 160-39 53 200-4 160 200 41 54 85 200-6 160 200-43 75 250-6 200 250-76 89 315-6 250 315 - - 115 400-6 315 400 - - 190 - = outside working area 4 = 425x425, 6 = 595x595 Specifications Easy to install and adjust Low sound level Adjustable air slot 0 or 12 mm 5 connection sizes and 2 diffuser sizes (425x425 or 595x595) All connection sizes are suitable for suspended ceiling systems (595x595), false ceiling plate available for size 425x425 Available with CleanVent coating Extremely compact plenum box ATTS Also available with the plenum box ATTD Product code example Exhaust air diffuser HPKH-250-6 Plenum box ATTS-200-250-1 1 (8) Specifications are subject of alteration without further notice.

Air flow, pressure drop, sound level Exhaust air diffuser HPKH + ATTS with 0 mm slot HPKH-160-4 + ATTS-125-160-1 - with 0 mm slot HPKH-160-6 + ATTS-125-160-1 - with 0 mm slot HPKH-200-4 + ATTS-160-200-1 - with 0 mm slot HPKH-200-6 + ATTS-160-200-1 - with 0 mm slot HPKH-250-6 + ATTS-200-250-1 - with 0 mm slot HPKH-315-6 + ATTS-250-315-1 - with 0 mm slot *) adjustment position ---- Min. airflow required to obtain sufficient measuring pressure. 2 (8) Specifications are subject of alteration without further notice.

Air flow, pressure drop, sound level Exhaust air diffuser HPKH + ATTS with 0 mm slot HPKH-400-6 + ATTS-315-400-1 - with 0 mm slot Exhaust air diffuser HPKH - with 0 mm slot *) adjustment position ---- Min. airflow required to obtain sufficient measuring pressure. 3 (8) Specifications are subject of alteration without further notice.

Sound power level Lw Exhaust air diffuser HPKH + ATTS with 0 mm slot, 1:2 plenum box Diffuser Connection ATTS Correction of sound level K (db) HPKH- inlet mm outlet mm 63 125 250 500 1000 2000 4000 8000 160-4 125 160 7 4 3 0-4 -1-10 -18 160-6 125 160 6 5 4 0-4 -1-10 -18 200-4 160 200 5 3 1-2 -4 1-11 -19 200-6 160 200 6 3 2-2 -4 0-12 -19 250-6 200 250 4 3 0-5 -5 1-12 -19 315-6 250 315 6 3-2 -4-2 1-12 -20 400-6 315 400 4-1 -4-3 -1 0-11 -19 Tolerance ± 6 3 2 2 2 2 2 3 Exhaust air diffuser HPKH with 0 mm slot HPKH- Correction of sound level K (db) 63 125 250 500 1000 2000 4000 8000 160-4 6 0 1-1 -1-1 -10-19 160-6 8 9 6 1-3 -4-11 -18 200-4 5-2 -4-6 -2-1 -6-17 200-6 0-3 -3-4 0-1 -11-17 250-6 4-4 -5-3 -2 0-12 -20 315-6 3-2 -7-6 -3 1-11 -12 400-6 3-6 -11-9 -4 2-11 -12 Tolerance ± 6 3 2 2 2 2 2 3 Sound power levels by octave bands are obtained by adding to total sound pressure level L p10a, db(a), the correction K oct presented in the table according to the following formula: L w = L p10a + K oct Correction K oct is average value in range of use of the device. 4 (8) Specifications are subject of alteration without further notice.

Sound attenuation ΔL Exhaust air diffuser HPKH + ATTS with 0 mm slot, 1:2 plenum box Diffuser Connection ATTS Sound attenuation (db) HPKH- inlet mm outlet mm 63 125 250 500 1000 2000 4000 8000 160-4 125 160 23 12 9 14 19 16 13 15 160-6 125 160 22 13 8 16 17 15 14 16 200-4 160 200 24 11 8 14 14 10 14 14 200-6 160 200 23 11 8 15 12 10 17 14 250-6 200 250 18 7 8 13 10 10 13 14 315-6 250 315 12 7 5 11 11 10 12 13 400-6 315 400 12 5 6 7 9 10 10 14 Tolerance ± 6 3 2 2 2 2 2 3 Exhaust air diffuser HPKH with 0 mm slot HPKH- Sound attenuation K (db) 63 125 250 500 1000 2000 4000 8000 160-4 20 12 5 0 0 0 1 3 160-6 21 12 5 3 1 1 1 3 200-4 17 10 4 1 1 0 1 2 200-6 17 10 3 2 1 0 1 2 250-6 14 8 2 1 0 0 0 1 315-6 12 7 3 1 0 0 0 1 400-6 10 5 2 0 0 0 0 0 Tolerance ± 6 3 2 2 2 2 2 3 The average sound attenuation ΔL from duct to room including the orifice attenuation of the connecting duct in ceiling installation, is obtained in the table above. More technical data can be found in our selection tool. Contact our nearest sales office for further information. 5 (8) Specifications are subject of alteration without further notice.

Dimensions and weights Plenum box ATTS Exhaust air diffuser HPKH s = 0 or 12 mm Size A B C ØD H Opening Weight [mm] [mm] [mm] [mm] [mm] [mm] [kg] 160-4 395 399 425 159.3 58 410 2.2 160-6 565 569 595 159.3 58 580 4.3 200-4 395 399 425 199.3 58 410 2.1 200-6 565 569 595 199.3 58 580 4.3 250-6 565 569 595 249.3 58 580 4.2 315-6 565 569 595 314.3 58 580 4.1 400-6 565 569 595 393.3 66 580 4.1 Size ØD1 ØD2 H L W K Weight [mm] [mm] [mm] [mm] [mm] [mm] [kg] 125-160 124.3 160 170 340 300 133 2.1 160-200 159.3 200 195 380 340 153 2.6 200-250 199.3 250 235 480 380 178 3.6 250-315 249.3 315 285 530 380 211 4.2 315-400 314.3 400 335 530 480 253 5.4 HPKH + ATTS HPKH Gmin [mm] Gmax [mm] 1:1 ATTS 1:2 ATTS 1:1 ATTS 1:2 ATTS 160-4 295 270 325 300 160-6 295 270 325 300 200-4 335 295 365 325 200-6 335 295 365 325 250-6 385 335 415 365 315-6 435 385 465 415 400-6 - 435-465 6 (8) Specifications are subject of alteration without further notice.

Execution and function The HPKH is a quiet, ceiling-mounted exhaust air diffuser. The diffuser has an almost completely perforated diffuser plate. The slot height of the diffuser can be set at 0 or 12 mm. Fixed to the diffuser body with magnets, the diffuser plate is easy to open. This exhaust air unit is suitable for both suspended ceiling systems and false ceilings built on site. The ATTS plenum box features an extremely quiet patented measurement and adjustment damper for multipoint measuring with balanced and accurate values. The adjustment handle of the measurement and adjustment damper has a position indicator and a locking device. The measurement and adjustment damper can be easily removed for inspection and cleaning without changing the setting. The diffuser connection collar is outwards in the plenum box. The ATTS plenum box is applicable for supply and exhaust air alike. In exhaust air use, the position of the measuring hose is changed to the measuring connector inside the box. General Material and surface finish Both the diffuser and the plenum box are made from steel sheet. The diffuser is powder-coated for a high surface finish. The standard colour is RAL 9010. Other diffuser colours and CleanVent coating are available on special order. Installation, adjustment and maintenance The instructions for installation, adjustment and maintenance are available at www.flaktgroup.com. The k-factors for supply air are also provided on the plenum box. Technical data and design For complete design details, please see the FläktGroup product selection program. The program can be found on the Internet at www.flaktgroup.com. Product description The square exhaust air diffuser, HPKH by FläktGroup with a plenum box, ATTS. The slot of the diffuser can be set at 0 or 12 mm. The diffuser plate, fixed to the diffuser body with magnets, is easy to open. The ATTS plenum box includes a quiet, easily removable measurement and adjustment damper (ZAEF). 7 (8) Specifications are subject of alteration without further notice.

Product code Exhaust air diffuser Exhaust air diffuser, CleanVent Exhaust air diffuser, special colour Size (aaa) 160, 200, 250, 315, 400 (diffuser connection) Body size (b) 4 = 425 x 425 6 = 595 x 595 CleanVent coated (C) Special colour (E) HPKH-aaa-b HPKH-aaa-b-C HPKH-aaa-b-E Accessories False ceiling plate for sizes 160-4 and 200-4 (body size of diffuser 425 x 425) Diffuser plate (from 9/2017) Body size of diffuser (a) 4 = 425 x 425 6 = 595 x 595 UTKZ-395 HPKZ-a-B Plenum box ATTS-aaa-bbb-c Duct connection in mm (aaa) Diffuser connection in mm (bbb) Type (c) 1 = collar outwards 8 (8) Specifications are subject of alteration without further notice.