Cable Glands - American Series - NEC/IEC

Similar documents
ADE 6F ADE 6F. page 46

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

Global Cable Gland Solutions

Global Cable Gland Solutions

The safety you rely on.

ABG Cable Glands Installation Procedure

Capri ADE 6F - for Armoured Cable

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Amphenol Cable Glands and Cord Grips Amphenol

Certificate of Compliance

MC, MCX & TCX Series ARMORED & UNARMORED CABLE GLANDS. Innovated Reliable Connectivity

Terminal Boxes Series 8125

As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands.

Flameproof Level Sensor (Flameproof F/S FP)

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

Cable Glands for Hazardous Areas

AI352 ATEX INLINE CONNECTOR TERMINATION PROCEDURE

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

New products Ex Equipment 2015

HTSB system System overview

ADDIMAX CABLE GLANDS FOR INDUSTRIAL USE [ 2 ]

Cable and Cord Fittings Hazardous and Non-Hazardous

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

Cable Connectors GET CONNECTED

INSTRUCTION MANUAL (ATEX / IECEx)

Terminal Boxes Series 8125

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Kopex-Ex cable glands offer superior protection in hazardous environments

Control Device System NEC Series ConSig 8040

Load disconnect switch Series 8146/5-V11

Flameproof Alternators

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Ex e, ia Junction boxes TNCN. Features

Terminal Boxes in Stainless Steel SLS**.T

Accessories Cable glands

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Section. Cable Glands. sa B-CABLES nv - T 09/ F 09/

Glass Reinforced Polyester Enclosures

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Compact temperature switch Model TCS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Self-Exciting Flameproof Alternator

SEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS. for HARSH AND HAZARDOUS ENVIRONMENTS. Certificate ANZEx

cable_glands_en.qxp :25 Uhr Seite 3 cable glands

Armoured / Un-armoured Cable Gland

Control Buttons / Switches for Panel Mounting Series 8003

The Earth-Rite MGV is designed to enable operators establish safe grounding of their vehicle in accordance with these recommended practices.

INSTRUCTION MANUAL (ATEX / IECEx)

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Terminal Boxes Series 8252/1

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

ADE5F. Inspectable Armour Cable Gland NEW! 2012 Eaton Corporation. All rights reserved.

Operating Instructions

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

8150 Series Terminal Boxes

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Transit Cable Products

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Control Panels, Distribution Panels and Components

Floodlight LED Series 6525

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight Series 6121

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Operating Instructions

Flameproof Alternator

Flameproof Alternator

UPC Power Connection Kit

EX-D ENCLOSURES AND DISTRIBUTIONS

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

7 Lighting Technology

Number Size Gasket A1 Gasket A2 Gasket A3 Gasket A4 Gasket A5 Metric B - C

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Flameproof Enclosures

Type MR 783 Magnetic level switch

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Explosion and flame-proof single phase electric motors

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

NXT Series Enclosures

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Load and Motor Switches, Load-Break Switches Series 8544

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Explosion and flame-proof cast iron electric motors

AI352 ATEX INLINE CONNECTOR TERMINATION PROCEDURE (Rev 6 02May07)

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Safety Switches Series 8537

Plug and Socket Devices SolConeX 16 A Series 8570

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Transcription:

Cable Glands - 103 American Series - NEC/IEC

104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection. The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. The Rear Sealing System covers the entire range of cable diameters without the need for special seals and the cable acceptance range is stamped on the backnut for ease of inspection. The backnut can be hand tightened, with only one further spanner turn required to ensure IP66, IP67, IP68 and NEMA 4X. 2 Armour Grounding Device This device provides 360 armour grounding which is fully Inspectable. The grounding device is unique in that it remains in contact with the metal cable jacket when the cable gland /connector is disassembled for inspection. 3 Inspectable Deluge Seal Hawke s Inspectable deluge seal offers IP66 and IP67 sealing and is certified as deluge proof by ITS in accordance with DTS01. Indeed, Hawke s deluge seal is so good that it exceeds the expectations of the offshore industry by not only preventing ingress into the equipment, but also into the cable gland, which could potentially corrode the cable armour. www.ehawke.com HPG01

Cable Glands Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). 710 105 For use with non-armoured cable, as permitted by the NEC. Ø 'D' Compound Size Size Ref. NPT Metric * Inner Jacket / Cores Outer Jacket 'B' Flats Standard Max. Over Max Inner Max. No. of Min. Max. Cores D Jacket E Cores Os ½" M20¹ 0.35" 0.39" 6 0.22" 0.47" 2.55" 0.94" 1.04" O ½" M20¹ 0.35" 0.39" 6 0.37" 0.63" 2.55" 0.94" 1.04" A ½" or ¾" M20 0.43" 0.64" 10 0.49" 0.81" 2.59" 1.18" 1.28" B ¾" or1" M25 0.64" 0.93" 21 0.66" 1.02" 2.80" 1.42" 1.56" C 1" or 1¼" M32 0.86" 1.23" 42 0.87" 1.30" 2.99" 1.81" 1.99" C2 1¼" or 1½" M40 1.04" 1.59" 60 1.10" 1.61" 3.18" 2.17" 2.36" D 2" or 1½" M50 1.46" 1.96" 80 1.42" 2.07" 3.60" 2.56" 2.79" E 2½" or 2" M63 1.88" 2.55" 100 1.81" 2.57" 3.59" 3.15" 3.46" F 3" or 2½" M75 2.32" 2.98" 120 2.24" 3.07" 3.99" 3.74" 4.09" H² 3½" M90 2.79" 3.12" 120 3.07" 3.52" 3.54 4.18" 4.84" All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering ¹ Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43. ² UL approved only UL Listing No: E84940. Suitable for use in: Class 1, Division 2, Gas Groups A, B, C and D Class 1, Zone 2, Gas Groups IIA, IIB and IIC AExd IIC and AExe II Class 1, Zone 2. Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. Certificate No s: Sira 06ATEX1295X and IECEx SIR 06.0082X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Operating Temperature Range: -50 C to +60 C (UL) and -60 C to +80 C (ATEX / IECEx). Assembly Instruction Sheet: AI 316 (UL) and AI 391 (ATEX / IECEx). DNV Marine Approval ABS Marine Approval Cable Gland / ConnectorType Size Thread 710 C 1"NPT Two part sealing compound and assembly instructions are supplied with the cable gland. Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. HPG01 www.ehawke.com

106 Ø 'D' 711 (& 713) Compound Deluge Boot Cable Glands Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). Outdoor or indoor use. For use with continuous corrugated aluminium Metal Clad (MCHL) cable. Size Inner Jacket / Cores Outer Jacket 'B' NPT Size Ref. Armour Standard Metric * Max. Over Max. No. of Flats Jacket E Min. Max. Cores D Cores Min. Max. A ½" or ¾" M20 0.43" 0.41" 0.64" 10 0.49" 0.81" 2.44" 1.18" 1.28" B ¾" or 1" M25 0.64" 0.49" 0.93" 21 0.66" 1.02" 2.68" 1.42" 1.56" C 1" or 1¼" M32 0.86" 0.85" 1.23" 42 0.87" 1.30" 2.76" 1.81" 1.99" C2 1¼" or 1½" M40 1.04" 1.17" 1.59" 60 1.10" 1.61" 2.96" 2.17" 2.36" D 2" or 1½" M50 1.46" 1.37" 1.96" 80 1.42" 2.07" 3.18" 2.56" 2.79" E 2½" or 2" M63 1.88" 1.76" 2.55" 100 1.81" 2.57" 3.21" 3.15" 3.46" F 3" or 2½" M75 2.32" 2.29" 2.98" 120 2.24" 3.07" 3.54" 3.74" 4.09" H¹ 3½" M90 2.79" 2.93" 3.47" 120 3.07" 3.52" 4.33" 4.18" 4.84" All dimensions in inches (except * where dimensions are in millimetres). A - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering ¹ UL approved only. UL Listing No: E84940. Suitable for use in: Class 1, Division 1, Gas Groups A, B, C and D Class 1, Zone 2, Gas Groups IIA, IIB and IIC AExd IIC and AExe II Class 1, Zone 2. Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. Certificate No s: Sira 06ATEX1295X and IECEx SIR 06.0082X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Operating Temperature Range: -50 C to +60 C (UL) and -60 C to +80 C (ATEX / IECEx). Assembly Instruction Sheet: AI 317 (UL) and AI 338 (ATEX / IECEx). DNV Marine Approval ABS Marine Approval Provides 360 armour grounding which is fully Inspectable. Grounding Device remains in contact with cable when disassembled for inspection. Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. Cable Gland / Connector Type Size Thread 711 C 1" NPT Two part sealing compound and assembly instructions are supplied with the cable gland. www.ehawke.com HPG01

Cable Glands Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). For use with braid armoured marine shipboard jacketed or non-jacketed cable. 753 Nickel Plated Hub Ø 'D' Compound Braid 'C' 107 Size Size NPT Ref. Standard Metric * Inner Jacket / Cores Outer Jacket 'B' Braid C Max. Over Max Inner Max. No. of Min. Max. Flats Cores D Jacket E Cores Os ½" M20² 0.35" 0.46" 6 0.22" 0.47" 0.008" / 0.013" 2.61" 0.94" 1.09" O ½" M20² 0.35" 0.46" 6 0.37" 0.63" 0.008" / 0.013" 2.61" 0.94" 1.09" A ½" or ¾" M20 0.43" 0.49" 10 0.49" 0.81" 0.008" / 0.013" 2.65" 1.18" 1.36" B ¾" or 1" M25 0.64" 0.72" 21 0.66" 1.02" 0.008" / 0.013" 2.75" 1.42" 1.64" C 1" or 1¼" M32 0.86" 0.97" 42 0.87" 1.30" 0.008" / 0.013" 2.93" 1.81" 2.09" C2 1¼" or 1½" M40 1.04" 1.16" 60 1.10" 1.61" 0.008" / 0.013" 3.15" 2.17" 2.50" D 2" or 1½" M50 1.46" 1.64" 80 1.42" 2.07" 0.008" / 0.013" 3.14" 2.56" 2.96" E 2½" or 2" M63 1.88" 2.11" 100 1.81" 2.57" 0.008" / 0.013" 3.42" 3.15" 3.64" F 3" or 2½" M75 2.32" 2.61 / 2.57" ¹ 120 2.24" 3.07" 0.008" / 0.013" 3.61" 3.74" 4.31" H³ 3½" M90 2.79" 3.05" 120 3.07" 3.52" 0.008" / 0.013" 3.54" 4.18" 4.84" All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering ¹ Smaller value is applicable when selecting standard NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43 ³ UL approved only. UL Listing No: E84941. Suitable for use in: Class 1, Division 1, Gas Groups A, B, C and D Class 1, Zone 2, Gas Groups IIA, IIB and IIC AExd IIC and AExe II Class 1, Zone 2. Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. Certificate No s: Sira 06ATEX1295X and IECEx SIR 06.0082X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, EC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Operating Temperature Range: -50 C to +60 C (UL) and -60 C to +80 C (ATEX / IECEx). Assembly Instruction Sheet: AI 318/339 (UL) and AI 373 (ATEX / IECEx). DNV Marine Approval GOST R-Exe IIU ABS Marine Approval Cable Gland / Connector Type Size Thread 753 C 1" NPT Two part sealing compound and assembly instructions are supplied with the cable gland. Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. HPG01 www.ehawke.com

108 Nickel Plated Hub Ø 'D' Compound Armour 'C' 755 Cable Glands Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). For use with armoured jacketed cable, as permitted by the NEC. Size Ref. Size NPT Standard Metric* Max. Over Cores D Inner Jacket / Cores Max Inner Jacket E Max. No. of Cores Outer Jacket 'B' Min. Max. Steel Wire Armour C Hexagon Dimensions Flats Os ½" M20² 0.35" 0.46" 6 0.22" 0.47" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.61" 0.94" 1.09" O ½" M20² 0.35" 0.46" 6 0.37" 0.63" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.61" 0.94" 1.09" A ½" or ¾" M20 0.43" 0.49" 10 0.49" 0.81" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.65" 1.18" 1.36" B ¾" or 1" M25 0.64" 0.72" 21 0.66" 1.02" 0.049" / 0.062" 0.008" / 0.013" 0.008" / 0.039" 2.75" 1.42" 1.64" C 1" or 1¼" M32 0.86" 0.97" 42 0.87" 1.30" 0.062" / 0.078" 0.008" / 0.013" 0.008" / 0.055" 2.93" 1.81" 2.09" C2 1¼" or 1½" M40 1.04" 1.16" 60 1.10" 1.61" 0.062" / 0.078" 0.008" / 0.013" 0.008" / 0.070" 3.15" 2.17" 2.50" D 2" or 1½" M50 1.46" 1.64" 80 1.42" 2.07" 0.078" / 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.14" 2.56" 2.96" E 2½" or 2" M63 1.88" 2.11" 100 1.81" 2.57" 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.42" 3.15" 3.64" F 3" or 2½" M75 2.32" 2.61 / 2.57" ¹ 120 2.24" 3.07" 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.61" 3.74" 4.31" All dimensions in inches (except * where dimensions are in millimetres). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. 3 Braid Tape ¹ Smaller value is applicable when selecting standard NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43 3 UL listing only applies to Steel Wire Armour. UL Listing No: E84940. Suitable for use in: Class 1, Division 2, Gas Groups A, B, C and D Class 1, Zone 2, Gas Groups IIA, IIB and IIC AExd IIC and AExe II Class 1, Zone 2. Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. Certificate No s: Sira 06ATEX1295X and IECEx SIR 06.0082X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Operating Temperature Range: -50 C to +60 C (UL) and -60 C to +80 C (ATEX / IECEx). Assembly Instruction Sheet: AI 319 (UL) and AI 382 (ATEX / IECEx). ABS Marine Approval DNV Marine Approval GOST R-Exe IIU Cable Gland / Connector Type Size Thread 755 C 1" NPT Two part sealing compound and assembly instructions are supplied with the cable gland. Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. www.ehawke.com HPG01

Cable Glands General Purpose 153/X 109 For use with armoured marine shipboard jacketed or non-jacketed cable. Ø 'A' Nickel Plated Hub Braid 'C' Size Ref. Size NPT Standard Metric * Standard Seal Alternative Seal (S) Outer Jacket B Min. Max. Min. Max. Min. Max. Braid C Flats Os ½" M20² 0.12" 0.31" - - 0.22" 0.47" 0.008" / 0.013" 2.04" 0.94" 1.04" O ½" M20² 0.30" 0.46" - - 0.37" 0.63" 0.008" / 0.013" 2.04" 0.94" 1.04" A ½" or ¾" M20 0.44" 0.56" 0.34" 0.52" 0.49" 0.81" 0.008" / 0.013" 2.08" 1.18" 1.28" B ¾" or 1" M25 0.52" 0.79" 0.38" 0.60" 0.66" 1.02" 0.008" / 0.013" 2.74" 1.42" 1.55" C 1" or 1¼" M32 0.75" 1.04" 0.61" 0.83" 0.87" 1.30" 0.008" / 0.013" 2.52" 1.81" 1.98" C2 1¼" or 1½" M40 0.99" 1.27" 0.87" 1.10" 1.10" 1.61" 0.008" / 0.013" 2.69" 2.17" 2.38" D 2" or 1½" M50 1.24" 1.74" / 1.67" ¹ 1.09" 1.37" 1.42" 2.07" 0.008" / 0.013" 3.11" 2.56" 2.78" E 2½" or 2" M63 1.68" 2.21" / 2.14" ¹ 1.54" 1.83" 1.81" 2.57" 0.008" / 0.013" 3.10" 3.15" 3.46" F 3" or 2½" M75 2.15" 2.67" / 2.57" ¹ 1.91" 2.29" 2.24" 3.07" 0.008" / 0.013" 3.29" 3.74" 4.09" H 3½" or 3" M90 2.64" 3.06" - - 2.96" 3.52" 0.008" / 0.013" 4.80" 4.53" 5.23" All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering ¹ Smaller value is applicable when selecting reduced NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43 ³ UL approved only. UL Listed for use Wet Locations. UL Listing No: E218332. Construction and Test Standards: UL 514B. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Operating Temperature Range: -50 C to +60 C. Assembly Instruction Sheet: AI 341. DNV Marine Approval ABS Marine Approval Provides armour clamping for marine shipboard cable. Provides a seal on the cables inner jacket. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured black to indicate General Purpose product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. Alternate Clamping Ring (S), add suffix S to ordering information. Cable Gland / Connector Type Size Thread (OPTIONAL) Cable Gland / Connector Type Size Thread (OPTIONAL) 153 CX M32 S 153 CX 1"NPT S HPG01 www.ehawke.com

110 701 Cable Glands General Purpose Armour Stop Nickel Plated Hub Deluge Boot Armour Grounding Device For use with continuous corrugated aluminium and interlocked steel Metal Clad MC and Teck type cables. Size Ref. Size NPT Standard or Metric * Option Armour Jacket E Outer Jacket B Min. Max. Min. Max. Flats A ½" or ¾" M20 0.41" 0.64" 0.49" 0.81" 2.44" 1.18" 1.28" B ¾" or 1" M25 0.49" 0.93" 0.66" 1.02" 2.68" 1.42" 1.56" C 1" or 1¼" M32 0.85" 1.23" 0.87" 1.30" 2.76" 1.81" 1.99" C2 1¼" or 1½" M40 1.17" 1.59" 1.10" 1.61" 2.96" 2.17" 2.36" D 2" or 1½" M50 1.37" 1.96" 1.42" 2.07" 3.18" 2.56" 2.79" E 2½" or 2" M63 1.76" 2.55" 1.81" 2.57" 3.21" 3.15" 3.46" F 3" or 2½" M75 2.29" 2.98" 2.24" 3.07" 3.54" 3.74" 4.09" H 3½" M90 2.93" 3.47" 3.07" 3.52" 4.33" 4.18" 4.84" All dimensions in inches (except * where dimensions are in millimetres). A - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering UL Listed for use Wet Locations. Certificate / Listing No: E165706. Construction and Test Standards: UL 514B. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. Operating Temperature Range: -50 C to +60 C. Assembly Instruction Sheet: AI 315/342. DNV Marine Approval ABS Marine Approval Provides 360 armour grounding which is fully Inspectable. Grounding Device remains in contact with cable when disassembled for inspection. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured black to indicate General Purpose product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. Cable Gland / Connector Type Size Thread 701 C 1" NPT www.ehawke.com HPG01