sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

Similar documents
IECEx Certificate of Conformity

ADE 6F ADE 6F. page 46

The safety you rely on.

ABG Cable Glands Installation Procedure

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

Amphenol Cable Glands and Cord Grips Amphenol

Armoured / Un-armoured Cable Gland

Capri ADE 6F - for Armoured Cable

Pratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box

Cable Glands - American Series - NEC/IEC

SEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS. for HARSH AND HAZARDOUS ENVIRONMENTS. Certificate ANZEx

cable_glands_en.qxp :25 Uhr Seite 3 cable glands

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

Certificate of Conformity

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

Installation Guidelines For BW Gland

Global Cable Gland Solutions

It s time to get connected with

As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands.

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas.

Global Cable Gland Solutions

Number Size Gasket A1 Gasket A2 Gasket A3 Gasket A4 Gasket A5 Metric B - C

ADJUSTABLE CABLE GLANDS

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

ATEX CABLE GLANDS.

ADDIMAX CABLE GLANDS FOR INDUSTRIAL USE [ 2 ]

Kopex-Ex cable glands offer superior protection in hazardous environments

Transit Cable Products

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Certificate of Conformity

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE

Local Control Station

22kV 425 AMP KA STYLE COUPLER 224BKA - Range

New products Ex Equipment 2015

Terminal Boxes Series 8252/1

SELECTION, APPLICATION AND MAINTENANCE

Cable Glands & Accessories

LMF / LMG RANGE ACCESSORIES CONTENTS

Section. Cable Glands. sa B-CABLES nv - T 09/ F 09/

HTSB system System overview

Glass Reinforced Polyester Enclosures

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

SOLENOID VALVES direct operated core disc 1/4

titan Street lighting cut outs fused products

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

6000 Series Buccaneer. Secure, quick connector mating and release. 30 twist locking Tamperproof lock prevents accidental un-mating

Self-Exciting Flameproof Alternator

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

Cable and Cord Fittings Hazardous and Non-Hazardous

Underfloor to desk 231

Anaconda IECEx-ATEX cable-hosefitting, type BXA, nickel plated brass.

Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application

Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69)

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

3. Fire Resistant Cables

UNION-EX Series Cable glands and accessories for applications in potentially explosive atmospheres

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

Cable resistance thermometer Model TR40

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

LMV RANGE CONTENTS. General information

Ex e, ia Junction boxes TNCN. Features

a Nexans company Catalogue 2008

AXIS. Cable Glands AAG ABW ABWL ABXL ACWG ACXG ACZG AE1W AE1X AE1Z AGXD AWG CONTENTS CAT #

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Certificate of Compliance

Flameproof Alternator

PORTFOLIO RODUCT. Enclosures Earthing and Lightning Protection Solution Personal Protection Equipment

7000 Series Buccaneer

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

LSZH Fire Resistant Cables

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

Cable resistance thermometer Model TR40

Cable Glands for Hazardous Areas

Compact temperature switch Model TCS

NXT Series Enclosures

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx

Cable resistance thermometer Model TR40

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Terminal Boxes TNCN. Explosion protection Marking

Terminal Boxes in Stainless Steel SLS**.T

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

General characteristics

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

Thread conversion products, breather drains and accessories

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

General characteristics and technical data Series MCS

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Cable thermocouple Model TC40

SOLENOID VALVES direct operated core disc 1/4

Technical data. Material e-reinforced polyester in grey or black. Seal Neoprene (CR) round cord (siliconized)

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

METRIC SELECTION TABLE. Entry Thread A B Catalog #

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box


Transcription:

KSG, KSGDS and KCG Range of Cable Glands This range of cable glands is intended for use with any cable type where sealing and retention is required by gripping the outer sheath (this includes armoured/screened/braided cables, the armour/screen/braid being clamped inside the terminating equipment); the KSG range has an ingress protection rating of IP68, tested for a depth of up to 25 m immersion for a duration of 30 mins. The KSG, KSGDS and KCG range comprises: associated enclosure silicone or neoprene elastomeric sealing ring, which fits into the entry body to provide a flameproof seal around the outer sheath of the cable outer cap and skid washer and silicone or neoprene elastomeric sealing ring; the cap tightens onto the entry body whilst compressing the seal onto the outer sheath of the cable These glands are available in the size range 16 to 100 mm with ISO metric entry threads of M20 to M100 respectively and coded Ex d IIC/Ex e II, except conduit types which are available in the size range 16 to 75 mm with ISO metric entry threads of M20 to M75 Alternative designs: the gland can be fitted with an additional mid-cap, skid washer and elastomeric sealing ring to create a double seal configuration (KSGDS types) the single seal configuration outer cap can be replaced with an alternative compression nut, which will accept either male or female conduit (KCG types) Alternative nearest equivalent and recognised entry body component thread forms: Aluminium to BS 1474:1987 grade HE30TF Date: 25 April 2006 Page 1 of 7

KDSW/KDSX, KISW/KISX and KOSW/KISX Range of Cable Glands These devices are intended for use with SWA/Tape/Woven Steel Wire armoured cables; the KDSW/KDSX and KISW/KISX types have an ingress protection rating of IP66/67 and the KOSW/KOSX ranges have an ingress protection rating of IP66. The KDSW/KDSX, KISW/KISX and KOSW/KOSX range comprises: a threaded entry body to tighten into an associated enclosure; with design options to fit either an optional outer deluge seal or an integral earthing clamp silicone or neoprene elastomeric sealing ring, which fits into the entry body to provide a flameproof seal around the inner sheath of the cable. The neoprene version has an option to be fitted with a continuity washer for use with lead sheathed cable armour clamp ring and cone to clamp onto SWA (KDSW, KISW and KOSW types) or Tape/Woven Steel Wire (KDSX, KISX and KOSX types) as appropriate. These also compress the seal onto the inner sheath of the cable with the aid of a mid-cap. mid-cap for coupling internal seal and armour locking mechanisms onto the entry body Outer cap, skid washer and silicone or neoprene elastomeric sealing ring. The cap tightens onto the midcap whilst compressing the seal onto the outer sheath of the cable with a skid washer. The elastomeric sealing ring also being available with an alternative reduced bore Glands are typically available in the size range 16 to 100 mm with ISO metric entry threads of M16 to M100 respectively, but not in every gland type variant. The KDSW/KDSX and KISW/KISX types of cable glands are coded Ex d IIC/Ex e II and the KOSW/KOSX types of cable glands are coded Ex e II. Glands fitted with a neoprene flameproof seal complete with a continuity washer are available in the size range 20S to 100 mm with ISO metric entry threads of M20 to M100 respectively; glands with this modification are designated with an L in their type number. Glands fitted with an entry body with an integral earthing clamp are available in the size range 16 to 75 mm with ISO metric entry threads of M16 to M75 Alternative nearest equivalent and recognised entry body component thread forms: Steel to BS 970:Part 1:1991 grades 220MO7Pb or 230MO7Pb Date: 25 April 2006 Page 2 of 7

The KISW/KISX types vary from the KDSW/KDSX by: the replacement of outer cap, skid washer, outer sheath elastomeric seal and mid-cap with an alternative cap tightening onto the entry body component not having the option to be fitted with the outer deluge seal, integral earth or continuity washer The KOSW/KOSX types vary from the KDSW/KDSX by: the removal of the inner sheath elastomeric seal, armour ring and armour cone not having the option to be fitted with the outer deluge seal or continuity washer. Date: 25 April 2006 Page 3 of 7

KUB, KBOS and KB Barrier Cable Gland Ranges & KSB Stopper Box Range These devices are intended for use with differing cables or conductors depending on type as listed below. They are coded Ex d I/Ex d IIC and have an ingress protection rating of IP68, tested for a depth of up to 100 m for a duration of 30 mins. Alternative nearest equivalent and recognised entry body component and KSB conduit nut internal thread forms: The KBOS Barrier Cable Gland Range is suitable for use with circular, unarmoured braided and screened cables; the glands comprise: a ferrule, fitted with an external nitrile O-ring. This fits into the entry body to make a two-part chamber into which a two-part elastomeric epoxy putty setting compound is applied, to provide a flameproof seal around the conductors a union nut that couples the entry body and ferrule together a seal housing, enclosing a white silicone elastomeric cable outer sheath seal and a skid washer, that is screwed and secured into the ferrule with Loctite 2701 adhesive a back nut that screws into the seal housing to compress the outer sheath seal Glands are available in the size range 16 to 100 mm with ISO metric entry threads of M20 to M100 A brass continuity washer may be fitted in the 20S to 100 mm sizes for use with lead inner sheathed cables. Glands with this modification are designated with an L in their type number. Date: 25 April 2006 Page 4 of 7

The KB Barrier Cable Gland Range is suitable for use with circular, unarmoured, braided and screened cables; the glands comprise: a ferrule, fitted with an external nitrile O-ring. This fits into the entry body to make a two-part chamber into which a two-part elastomeric epoxy putty setting compound is applied to provide a flameproof an inner seal around the conductors a union nut that couples the entry body and ferrule together a back nut that is screwed and secured into the ferrule with Loctite 2701 adhesive Glands are available in the size range 20S to 100 mm with ISO metric entry threads of M20 to M100 A brass continuity washer may be fitted that are used with lead inner sheathed cables. Glands with this modification are designated with an L in their type number. The KUB Barrier Cable Gland Range is suitable for use with circular, pliable wire, single wire and steel tape armoured cables along with braided/screened and unarmoured cables; the glands comprise: a cone, fitted with an external nitrile O-ring. This fits into the entry component to make a two-part chamber into which a two part elastomeric epoxy putty setting compound is applied to provide a flameproof seal around the conductors a clamp ring that secures cable armour to the cone and also provides earth protection a mid-cap component that fastens to the entry body to captivate the clamp ring, cone and epoxy putty. a back nut, enclosing a white, silicone, elastomeric, cable outer sheath seal and skid washer, that screws onto the external thread of the mid cap. The elastomeric sealing ring also being available in red with a reduced bore Glands are available in the size range 16 to 100 mm with ISO metric entry threads of M20 to M100 a brass continuity washer may be fitted in the 20S to 100 mm sizes that are used with lead inner sheathed cables, glands with this modification are designated with an L in their type number The KSB Conduit Stopper Box Range is suitable for use with conductors carried in conduit or for converting cable glands into a flameproof barrier; the stopper boxes comprise: a ferrule, fitted with an external nitrile O-ring. This fits into the entry body to make a two-part chamber into which a two-part elastomeric epoxy putty setting compound is applied to provide a flameproof seal around the conductors a union nut that couples the entry body and ferrule together a conduit nut that is screwed and secured into the ferrule with Loctite 2701 adhesive These devices are available in the size range 20 to 100 mm with ISO metric entry threads of M20 to M100 Date: 25 April 2006 Page 5 of 7

KDSU, KOSU and KISU Ranges of Cable Glands These ranges of cable glands are intended for use with differing cables depending on gland type as listed below and having ISO metric entry threads. The KOSU Range of Cable Glands has an ingress protection rating of IP66 and is coded Ex e II. The KDSU and KISU Ranges of Cable Glands have an ingress protection rating of IP68, tested for a depth of up to 25 m for a duration of 30 mins and coded Ex d IIC/Ex e II. Alternative nearest equivalent and recognised Entry body component thread forms: The KDSU Range of Cable Glands is suitable for armoured or unarmoured cables and comprises: threaded entry body, including a groove to accommodate an optional O-ring seal, which tightens into an associated enclosure silicone or neoprene elastomeric sealing ring, which fits into the entry body to provide a flameproof seal around the inner sheath of the cable armour ring and armour cone to clamp onto armour/screen/braid (when applicable to installation), compression nut and skid washer. The compression nut with the skid washer compressing the seal onto the inner sheath of the cable, minimising cable twist upon assembly mid-cap for coupling internal locking mechanisms onto the entry body outer cap, skid washer and silicone or neoprene elastomeric sealing ring. The cap tightens onto the midcap whilst compressing the seal onto the outer sheath of the cable and a skid washer minimising cable twist upon assembly. The elastomeric sealing ring also being available in red with a reduced bore Glands are available in the size range 16 to 100 mm with ISO metric entry threads of M20 to M100 Cable glands fitted with neoprene flameproof elastomeric sealing rings may be fitted with a brass continuity washer in the 20S to 100 sizes that are used with lead inner sheathed cables, glands with this modification are designated with an L in their type number. The KISU Range of Cable Glands is suitable for armoured or unarmoured cables and varies from the KDSU by: the replacement of outer cap, skid washer and outer sheath elastomeric seal with an alternative cap tightening onto the entry body component not having the option to be fitted with brass continuity washer The KOSU Range of Cable Glands is suitable for armoured cables and varies from the KDSU by: Date: 25 April 2006 Page 6 of 7

the removal of the inner sheath elastomeric seal and skid washer not having the option to be fitted with brass continuity washer Date: 25 April 2006 Page 7 of 7