Series V. Electric. switch mechanisms. and housings. Installation and Operating Manual

Similar documents
Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

SOLITEL. Vibrating Rod. Level Switch. for Solids. Installation and Operating Manual. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx

ECHOTEL 961/962 LOOP POWERED

ECHOTEL MODELS 915-P / 915-W

ECHOTEL 961/962 LOOP POWERED

VIZUAL. Magnetic. Level. Indication. Installation and Operating Manual For the Magnetic Level Indicator (MLI) 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx.

ECHOTEL 961/962 LOOP POWERED

ECHOTEL 961/962 LINE POWERED

J52 Refrigerant Level Switches

INSTALLATION / INSTRUCTION MANUAL

Tuffy Liquid Level Controls with Pneumatic Switch

Series K Pneumatic Switch Mechanism

F10. Vane type flow switches INSTRUCTION MANUAL AND PARTS LIST AGENCY APPROVALS DESCRIPTION OPERATING PRINCIPLE

Hermetically Sealed Switches

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Installation and Operating Manual

Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

THERMATEL MODEL TD1/TD2

For Hazardous Locations

Displacer Type. Installation and Operating Manual. Liquid Level and Proof-er Switches

Tuffy Liquid Level Switches

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Series 3. Liquid Level Switches. ASME B31.1 Construction. Installation and Operating Manual

L070 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL. For Industrial Use

For CRN Installations

DIAMOND POINT VIBRATING PROBES

Displacer Type. Installation and Operating Manual. Liquid Level and Proof-er Switches

OPERATIONS MANUAL LEVER CHAIN HOIST

Limit Switch Type 4747

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

60 Series End-Mount Brake Instructions Standard Housing

External Cage Displacer Actuated

Level Measurement based on Archimedes Principle. Device Description

LIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch

McCANNA Actuation Systems B

APM Pneumatic Control for Boiler Feed System Applications

Limit Switch Type 3776

EZ Modulevel. Displacer. Operated. Level/Interface. Measurement. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx. Installation and Operating Manual

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Magnetic Level Gauges

Flameproof Level Sensor (Flameproof F/S FP)

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

ECON Limit Switch Box Fig

HQ Series ¼ Turn Electric Actuator

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

MV Series Motors Operation & Parts Manual

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Installation, Operation & Maintenance Manual

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

J 6 Se r i e s. Pressure and Vacuum switches. features

END SUCTION CENTRIFUGAL PUMPS

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Installation, Operation and Maintenance Manual

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Magnetic Level Gauges

Model B73 & Series 75

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

M-100 Adjustable flow switch with right-angle flow

LIMIT SWITCH BOX MODEL - APL

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Electronic Limit Switch Type

Know-how makes the difference. Limit Switches

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

ST Charger. Industrial Battery Charger

MS40 MS40/EX Explosion

MS Rev c ( ) DCN0530

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Installation Instructions for Drapery System Drapery

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Full View Flow Indicator

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Operation and Maintenance Manual for Joyce Dayton. Integrated Actuator- Acme Screw. Maximum capacity: 2000-pounds

Operating Instructions

The Da-Lite Difference.

10 S e r i e s PRESSURE SWITCH. features

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Terminal Boxes Series 8125

Type Pneumatic Control Unit. Operating Instructions

Type Pneumatic Control Unit. Operating Instructions

HQ Series ¼ Turn Electric Actuator

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Instruction Manual. Ex-Time 40 / 50

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Data sheet pneumatic barring devices KD80-KD200

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Refinery Supply Company, Inc.

Heavy Duty Series (HDS) Installation and user guide

Transcription:

Series V Installation and Operating Manual Electric switch mechanisms and housings

UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours. Check the contents of the carton/crates against the packing slip and report any discrepancies to Magnetrol. Check the nameplate model number to be sure it agrees with the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. 0038 These units are in conformity with the provisions of: 1. Directive 2014/34/EU for equipment or protective system intended for use in potentially explosive atmospheres. EC-type examination certificate number PTB 00 ATEX 2049X, see certificate for applied standards and certification details. 2. The PED directive 97/23/EC (pressure equipment directive). Safety accessories per category IV module H1. PRINCIPLE OF OPERATION 5 Process liquid 4 1 3 2 Pivot Return Spring Process liquid Figures 1 & 2 illustrate the simple, reliable operating principle of a float level switch. Switching action is obtained through the use of a magnetic sleeve (4) and a float (3), displacer or flow sensing element and a switching mechanism (2). These two basic component assemblies are separated by a non-magnetic, pressure tight enclosing tube (5). The switch (2) and magnet (1) are assembled to a mechanism with a swinging arm which operates on precision stainless steel pivots. As level of a liquid in a vessel rises (Figure 1), the float rides on the liquid surface moving the magnetic sleeve upward in the enclosing tube and into the field of the switch mechanism magnet. As a result, the magnet is drawn in tightly to the enclosing tube moving the measuring plate out of the slot of the proximity switch. As the liquid level recedes (Figure 2), the float and magnetic sleeve moves downward until the switch magnet releases and is drawn outward, away from the enclosing tube by a tension spring. This in turn allows the measuring plate to move into the slot, thus reversing switch action. Figure 1 Rising level Figure 2 Falling level DESCRIPTION Series V switches are inductive proximity switches type SJ3,5-SN with a maximum liquid temperature rating of +100 C (+210 F), see figure 3. Figure 3 Series V 2

MOUNTING Replacing the complete switch mechanisms CAUTION: Before attempting to remove a switch mechanism, be certain to pull disconnect switch or otherwise assure that electrical circuit through control is de-energized. Mounting screw Figure 5 Baffle plate screw Figure 4 Mounting screw Baffle plate screw 1. Remove the switch housing cover (see page 7). 2. Disconnect wiring from supply side of terminal block on switch mechanism. Note and record lead wire terminal locations. 3. Loosen screw in split mounting clamp until mechanism slides freely on enclosing tube, refer to Figure 4. 4. Remove small round head screw securing lower switch mechanism to baffle plate, refer to Figure 5. 5. Slide switch mechanism off of enclosing tube. If mechanism is to be reused, ensure that it is placed on a clean surface, free of metallic particles that may be attracted to the switch magnet. 6. Loosen mounting screw so that switch frame will fit over e-tube. Install switch mechanism by sliding it over the enclosing tube. Slide mechanism down until the bottom of the frame and terminal block are resting on the baffle plate. The baffle plate should be resting on the hub of the housing base. 7. Install and tighten baffle plate screw so that the switch mechanism may not be separated from the baffle plate. Tighten the mechanism mounting screw so that the mechanism is firmly clamped to the enclosing tube. 8. Swing magnet assembly in and out by hand, checking carefully for any signs of binding. 9. Reattached supply-side wiring to the terminal block. 10. Reinstall the switch housing cover (see page 7). 11. Reconnect power supply and test switch action under operating conditions. Replacing the switches only 1. Disconnect control from power supply. 2.Remove the switch housing cover (see page 7). 3. Disconnect switch leads from terminal block. Note and record terminal connections of switch to be replaced. 4. Remove the mounting screw holding existing switch, refer to Figure 6. 5. Remove existing switch and install replacement switch in the same position, tightening mounting screw securely. 6. Reinstall the switch housing cover (see page 7). 7. Reconnect power supply and test switch action by varying liquid level in the vessel or by gently blowing down float chamber. Mounting screw Figure 6 3

MOUNTING Vibration service adjustment Level controls are frequently used in applications where vibration is encountered, such as on scrubbers or compressors. Switch mechanisms may require repositioning to prevent unwanted magnet movement. This position is usually best at right angles to the direction of vibration. The direction of vibration may be determined by the arrangement of connections to the vessel or the vessels mounting method. Accordingly, the vibration will tend to be in one direction only. Upon determining the vibration direction, switch mechanism(s) may be rotated from an incorrect position (as shown in Figure 7, illustration is shown as looking at a control from above), to a correct position as follows: Vessel Baffle plate Frame mounting screw Incorrect CAUTION: Before attempting to remove a switch mechanism, be certain to pull disconnect switch or otherwise assure that electrical circuit through control is de-energized. Direction of vibration 1. Disconnect control from power supply. 2.Remove the switch housing cover (see page 7). 3. Loosen screw in split mounting clamp until mechanism turns freely on enclosing tube, refer to Figure 4 on page 3. 4. Rotate entire mechanism and bottom baffle plate together to the correct position. Baffle plate CAUTION: Be certain power supply wires retain some slack at new position. Do not pull wires taut. Correct NOTE: Amount of rotation required will vary with each installation and may not be as much as shown in illustration. Direction of vibration Swing of magnet 5.Check action of switch magnet at new position. When magnet vibrates from side to side, instead of front to back, correct position has been attained. 6. Tighten clamp screw on switch mechanism. 7. Reinstall the switch housing cover (see page 7). 8. Reconnect power supply and test switch action under operating conditions. Figure 7 Rotation of switch mechanism in vibration 4

WIRING Circuits shown are for direct-acting level switches and are reversed in side mounting float-in-tank models, which utilize a reversing float pivot. Terminal connections L+ L- 4 5 Internal circuit Figure 8 PREVENTIVE MAINTENANCE Inspect switch mechanisms, terminals and connections regularly. Proof test interval to be determined by application requirements (required reliability, operating conditions, site requirements, etc). Inspect switch mechanisms, terminals and connections 1. DO NOT operate your control with defective or maladjusted switch mechanisms. 2. Level controls may sometimes be exposed to excessive heat or moisture. Under such conditions, insulation on electrical wiring may become brittle, eventually breaking or peeling away. The resulting bare wires can cause short circuits. NOTE: Check wiring carefully and replace at the first sign of brittle insulation. 3. Vibration may sometimes cause terminal screws to loosen. Check all terminal connections to be certain that screws are tight. NOTE: Spare switches should be kept on hand at all times. SWITCHES Switch ratings SWITCH SERIES SWITCH TYPE Process Temperature range C ( F) LOAD RATING V Proximity -40 to +100 (-40 to +210) NAMUR output As per NAMUR standard EN 60947-5-6:2000 Max. Process Temperature based on +40 C (+100 F) ambient temperature. 5

REPLACEMENT SWITCH MECHANISMS Magnet strength Switch mechanisms are provided with different strength magnets as determined by the characteristics of the level switch. A red or yellow dot is visible on each magnet. When ordering replacement switch mechanisms, be certain to determine the color dot on the magnet. For these types of switches, the last 3 digits of the model number identify the switch and magnet used on the control. The correct magnet dot color may be chosen by finding those 3 digits of your model number in the chart. Any model numbers preceded with an X are specially modified controls. Contact the factory for replacement part numbers. Partn : Digit in partn : X 1 2 3 4 5 6 7 8 9 10 Serial n : See nameplate, always provide complete partn and serial n when ordering spares. X = product with a specific customer requirement EXPEDITE SHIP PLAN (ESP) Several parts are available for quick shipment, within max. 1 week after factory receipt of purchase order, through the Expedite Ship Plan (ESP). Parts covered by ESP service are conveniently grey coded in the selection tables. Yellow dot magnet replacement mechanisms Switch Series 8th, 9th & 10th Digit Set points Switch & mechanism Switch only V VBS, VCS, VES, V5S 1 047-9108-001 009-3989-002 Red dot magnet replacement mechanisms Switch Series 8th, 9th & 10th Digit Set points Switch & mechanism Switch only V VFS, VHS, VJS, VLS 1 047-9108-002 009-3989-002 6

REPLACEMENT SWITCH HOUSINGS Switch housing replacement assemblies When ordering replacement parts for an existing Magnetrol instrument, please specify: 1. Model and serial numbers of control. 2. Description and part number of replacement kit. The proper replacement switch housing kit and parts can be determined by the last three characters of the model number. Cast aluminum housings (short and tall) Die cast aluminum TYPE 4X housing replacements are available for general purpose or weatherproof installations. Die cast aluminum housings are finished with a baked-on polyester powder coat paint. Replacement housing kits Table with switch & housing model codes: Switch & housing code e.g. V5S, VBS, VFS, VHS,... 8 9 1 Description Kit contains part(s) Replacement part Cover kit for short housing 1, 8, 9 089-6582-036 Cover kit for tall housing 1, 8, 9 089-6582-038 Base kit for M20 x 1,5 cable entry 3, 4, 5, 6, 7, 8 089-6582-042 Base kit for 1" NPT-F cable entry 3, 4, 5, 6, 7, 8 089-6582-043 Cover 'O'-ring 8 012-2201-253 Base 'O'-ring 7 012-2201-116 Baffle plate 2 005-6657-001 2 3 4 1. Housing cover 2. Baffle plate 3. Housing base 4. Stopping plug 5. Base lock screw 7 6 5 6. Base lock screw 7. Base O-ring 8. Cover O-ring 9. Caution tag Figure 9 Standard cast aluminium housing (short and tall) Assemble / Disassemble instructions 1. Disconnect control from power supply before opening. 2. Unscrew the cover (1) counterclockwise. Lift housing cover straight upwards to avoid damaging the inside switch mechanism. 3. Replacement of housing base (3) and/or base O-ring (7). 3.1 First remove housing cover (1) - see 1-2. 3.2 Remove entire switch mechanism (see page 3). 3.3 Loosen base lock screws (5) & (6). 3.4 Slide housing base (3) of enclosing tube. 3.5 O-ring (7) can be accessed/replaced. 4. Replace part and mount in opposite order. 5. Close housing cover (1) clockwise. SWITCH AND HOUSING MODEL CODES The following charts identify the switch and housing model codes used with the buoyancy products. The eighth, ninth and tenth digit combinations may be used to identify the type and number of switches, number of contacts, switch magnet strength as well as housing type, size and options. ATEX - IP 66 II 1G EEx ia IIC T6 Cast aluminium Magnet dot color M20x1.5 1" NPT V5S VBS Yellow VFS VHS Red VCS VES Yellow VJS VLS Red Set points Switch contacts Housing height 1 NAMUR Short 1 NAMUR Tall Switch type Proximity 7

IMPORTANT SERVICE POLICY Owners of Magnetrol products may request the return of a control; or, any part of a control for complete rebuilding or replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to the purchaser, (or owner) other than transportation cost if: a. Returned within the warranty period; and, b. The factory inspection finds the cause of the malfunction to be defective material or workmanship. If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour and the parts required to rebuild or replace the equipment. In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of our warranty. No claims for misapplication, labour, direct or consequential damage will be allowed. RETURNED MATERIAL PROCEDURE So that we may efficiently process any materials that are returned, it is essential that a Return Material Authorisation (RMA) form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is available through Magnetrol s local representative or by contacting the factory. Please supply the following information: 1. Purchaser Name 2. Description of Material 3. Serial Number and Ref Number 4. Desired Action 5. Reason for Return 6. Process details Any unit that was used in a process must be properly cleaned in accordance with the proper health and safety standards applicable by the owner, before it is returned to the factory. A material Safety Data Sheet (MSDS) must be attached at the outside of the transport crate or box. All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments. All replacements will be shipped Ex Works. UNDER RESERVE OF MODIFICATIONS BULLETIN N : BE 42-798.0 EFFECTIVE: DECEMBER 2014 SUPERSEDES: New www.magnetrol.com BENELUX FRANCE DEUTSCHLAND Heikensstraat 6, 9240 Zele, België -Belgique Tel. +32 (0)52.45.11.11 Fax. +32 (0)52.45.09.93 E-Mail: info@magnetrol.be Alte Ziegelei 2-4, D-51491 Overath Tel. +49 (0)2204 / 9536-0 Fax. +49 (0)2204 / 9536-53 E-Mail: vertrieb@magnetrol.de INDIA B-506, Sagar Tech Plaza, Saki Naka Junction, Andheri (E), Mumbai - 400072 Tel. +91 22 2850 7903 Fax. +91 22 2850 7904 E-Mail: info@magnetrolindia.com ITALIA Via Arese 12, I-20159 Milano Tel. +39 02 607.22.98 Fax. +39 02 668.66.52 E-Mail: mit.gen@magnetrol.it RUSSIA 198095 Saint-Petersburg, Marshala Govorova street, house 35A, office 427 Tel. +7-812.702.70.87 E-Mail: info@magnetrol.ru U.A.E. DAFZA Office 5EA 722 PO Box 293671 Dubai Tel. +971-4-6091735 Fax +971-4-6091736 E-Mail: info@magnetrol.ae UNITED Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL KINGDOM Tel. +44 (0)1444 871313 Fax +44 (0)1444 871317 E-Mail: sales@magnetrol.co.uk