Reactor Safety /22.903

Similar documents
5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS

74 ow. 10 CFR 50.46(a)(3)(ii)

Weir Valves & Controls USA Inc. World Leader in Design, Manufacture and Service Support for BWR and PWR MSIV s

Circuit Breaker Users Group Open Session Breifing. Jim Sharkey Senior Project Manager Circuit Breaker Users Group Meeting June 6, 2012

Nuclear L.L. C. 10 CFR 50.55a

Presented at SC-2, Meeting October 5-6, 2010,, Seattle, WA

The B&W mpower TM Small Modular Reactor I&C Design, Architecture and Challenges

STANDARD REVIEW PLAN

The IAEA does not normally maintain stocks of reports in this series.

Hope Creek Variable Frequency Drive

Streamlined RI-ISI. Patrick O Regan EPRI

Aoý. 0Constellation Nuclear. Calvert Cliffs Nuclear Power Plant. February 27, U. S. Nuclear Regulatory Commission Washington, DC 20555

DRAFT SONGS Units 2 and 3 Irradiated Fuel Management Plan

Visual Inspection of Reactor Vessel Head Penetration Nozzles

How Nuclear Projects Fail. Edward Kee

How Nuclear Projects Fail. Edward Kee

Operational risks of old nuclear power plants in Switzerland

References 2 and 3 provided additional information as requested. April 25, 2011

Health Monitoring of Rotating Equipment from Torsional Vibration Features

, Fax

NUCLEAR POWER GENERATION. Est Safety-Related and Commercial Actuation Products

April 23, U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC

Shop and Service Center Motors

Probabilistic Risk Assessment for Spent Fuel Pool Decommissioning in the J. Bohunice V1 NPP

ams.t.andard REVIEW PLAN.

Transient Analysis for Simulator Validation. Jeffrey A. Borkowski 2008 US Users Group Meeting Tempe, Arizona October

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C May 8, 2018

SUBJECT: Watts Bar Unit 2 Operating License Proceeding

A Decommissioning Wrapup

TEPCO NUCLEAR SAFETY REFORM PLAN PROGRESS REPORT 1 ST QUARTER FY 2014 EXECUTIVE SUMMARY

The Role of Nuclear Power

CC System B B 3.7 PLANT SYSTEMS. B Component Cooling Water (CC) System BASES

OPAL : Commissioning a New Research Reactor. IAEA Conference, Sydney, November 2007

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

AP1000 Nuclear Power Plant Squib Valve Design Challenges & Regulatory Interface. September 2017

Component Asset Management with Ultra-High Pressure Cavitation Peening

A Tool for planning the Safety Review of SSCs: Development and Application

Westinghouse AP1000 Plant

Outage dates (duration): March 2, 1993 to April 20, 1994 (1.1 years) Reactor age when outage began: 11.7 years

REGULATORY CONTROL OF NUCLEAR FUEL AND CONTROL RODS

The ADS-IDAC Dynamic PSA Platform with Dynamically Linked System Fault Trees

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C May 11, 2012

Duke Power Company DOCUMENT TRANSMITTAL FORM REFERENCE MCGUIRE NUCLEAR STATION SELECTED LICENSEE COMMITMENTS MANUAL. Page 2 of 3

ucssenator-markey-weather-related-events.pdf

EOP SETPOINT UPGRADE PROJECT. Date: January 2008

Safe solutions for transport and dry storage of defective fuel rods. Authors: Vanessa Vo Van, Isabelle Morlaes, Justo Garcia, Kay Muenchow

AP1000 Plant Overview

NuScale Program WIN And WIN-WA

EXAMINATION OF NOZZLE INNER RADIUS AND PIPING FROM THE OUTER SURFACE

GE ABWR & ESBWR. Jeff Suggs ESBWR I&C April 17, Copyright 2006 by GE Energy / Nuclear

PO Box 88 Glendale Springs, North Carolina (336)

related Safety Evaluation is also enclosed. The notice of be included in the Commission's biweekly Federal Register

Single-phase Coolant Flow and Heat Transfer

UAMPS and NuScale Carbon Free Power Project

Evaluation of sealing performance of metal. CRIEPI (Central Research Institute of Electric Power Industry)

NSTD Introductory Course

AP1000 European 7. Instrumentation and Controls Design Control Document

Docket No , License No. NPF CFR 50.55a Request VR-1. Revision 1. Align Valve Testing Frequencies to

Case Study: Silver Lining in Plants Oil Analysis Program Prevents Catastrophic Generator Failure

APR1400 Electric System Design. KHNP KEPCO E&C November 29, 2017

Super-Critical Water-cooled Reactors

ICPVT-9. Proceedings. Volume 2. 9th International Conference. Operation, NDE, Failure Analysis, Codes, Standards and Regulations

Energy Opportunities in Indiana

Westinghouse SG Tube Sleeve Designs and Installation. Jesse Baron, PE Principal Engineer

Forsmark 12. S3K Applications. Thomas Smed US User Group Meeting Arizona, October 2008

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

A.L. Izhutov, A.V. Burukin, Current and prospective fuel test programmes in the MIR reactor

ASME BPV XI NUCLEAR INSERVICE INSPECTION STANDARDS COMMITTEE HANDOUT

Class 1E LOCA Cabled Connectors

TREASURE VALLEY IRRIGATION CONFERENCE

TELEDYNE TECHNOLOGIES TELEDYNE BROWN ENGINEERING Approved for Public Release. Many images contained herein courtesy of NASA

ALSTOM WORLD WIDE EXPERIENCE OF STEAM TURBINE RETROFITS ON NUCLEAR POWER PLANTS. May 2015

The role of CVR in the fuel inspection at Temelín NPP

Nuclear. May 19, 2001 SVP U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C

MCC MCCB Roundtable Session Notes

GOVERNOR CONVERSIONS. 2301A and DRU replacement of EGA and MOP

Korea Nuclear Association for International Cooperation. 27 March 2012

Scientech Stresswave SRV Leak Detection Scientech Symposium 2015

Case Study: Silver Lining in Plants Oil Analysis Program Prevents Catastrophic Generator Failure

Nuclear Energy Tribal Working Group

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

Radiological Safety for the Design and Construction of Apparatus for Gamma Radiography. ANSI S3.6 Specifications for Audiometers 1969 NRC

Balanced Stator Seal for Reactor Coolant Pump Retrofits

CAREM PROTOTYPE CONSTRUCTION AND LICENSING STATUS

New Nuclear Plants In the United States: Progress and Expectations

An Overview of Spent Fuel Storage in the US

Experimental study of DHC. cladding and implications. dry storage conditions

Fuel Management in EWN

Supplemental Report on the NCTPC Collaborative Transmission Plan

Investigation into UK socket-outlets incorporating USB charging points

June 22, 2017 Nashville, TN

wameren UF January 18, 2001 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, DC ULNRC-04353

CITY OF NEWTON Septage and Grease Trap Waste Disposal Program TABLE OF CONTENTS

Research Article Separation of Transformers for Class 1E Systems in Nuclear Power Plants

Improving predictive maintenance with oil condition monitoring.

Online Appendix. Deregulation and Investment in Generation Capacity: Evidence from Nuclear Power Uprates in the United States

Sincerely, /s/ Victor Nerses, Senior Project Manager Project Directorate 1-2 Division of Reactor Projects - 1/11. Office of Nuclear Reactor Regulation

Right-of-Way Obstruction Permit Fee Structure Minneapolis Department of Public Works May 10, 2001

FINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority

mew Doc 2578 Filed 02/16/18 Entered 02/16/18 12:17:29 Main Document Pg 1 of 7

Transcription:

Reactor Safety 22.091/22.903 Professor Andrew C. Kadak Professor of the Practice Lecture 24 Current Regulatory Safety Issues Page 1

Topics to Be Covered Reactor Vessel Integrity Embrittlement PWR Sump Performance Reactor Coolant System Weld Issues Davis Besse Head Degradation Fire Protection (Hemyc Insulation) Plant Security and Terrorism Ground water contamination tritium Safety Conscious Work Environment Safety Culture Human Factors Page 2

Reactor Vessel Integrity Driven in part by Yankee Rowe Vessel Issue Depending on weld and metal materials some vessels vulnerable to embrittlement Need to have in reactor specimens to gauge degree of embrittlement Reactor have chosen to manage fuel differently low leakage cores Only major life limiting component in reactors Page 3

PWR Sump Performance During a LOCA debris from paint, insulation and other materials will clog sump screens Failing or cavitation recirculation spray Net Positive Suction Head insufficient Similar to BWR issue Page 4 Source unknown. All rights reserved. This content is excluded from our Creative Commons license. For more information, see http://ocw.mit.edu/fairuse.

Reactor Coolant System Weld Issues Primary Water Stress Corrosion Cracking Alloy 82/182/600 welds Temperature, residual stresses, Nickel based alloys Plants: Wolf Creek, V.C. Summer, South Texas Project, Crystal River 3, etc. Solution inspection and weld overlay Page 5 Source unknown. All rights reserved. This content is excluded from our Creative Commons license. For more information, see http://ocw.mit.edu/fairuse.

Fire Protection Objective to prevent fires and failures due to fires that affect safety of the plant Appendix R governing regulation Required separation of trains Insulation fire doors fire watches Fire PRAs being developed Problems with tests of some insulation Hymec failing to meet NRC fire retardant time issue. Page 6

Security and Terrorism Aircraft Crash Upgrade to physical security Design Basis Threat Force on Force Page 7

Ground Water Contamination Water leaks containing tritium Big issue at Brookhaven National Lab changed lab Leaks in water systems at Indian Point, Braidwood, Callaway, Dresden, Bryon, Palo Verde, Quad Cities Leaks frequently coming from spent fuel pool liners. Public outcry Reporting requirements refined Levels of tritium still low within limits. Page 8

Page 9

Recent Enforcement Actions Reactor Actions Exelon Generation Company, LLC (Byron Station) EA-08-046 On April 1, 2008, a Notice of Violation (NOV) was issued for violations associated with a White Significance Determination Finding. The NOV involved violations of 10 CFR Part 50, Appendix B Criterion XVI, Corrective Actions, and 10 CFR Part 50, Appendix B, Criterion III, Design Control. Specifically, the licensee failed to take timely corrective actions after the identification of extensive corrosion on essential service water riser pipes and failed to verify the adequacy of the methodology and design inputs in calculations that supported the decision to accept three degraded essential service water riser pipes for continued service. Source unknown. All rights reserved. This content is excluded from our Creative Commons license. For more information, see http://ocw.mit.edu/fairuse. Appendix B violation Quality Page 10

Enforcement Action Luminant Generation Company, LLC (Comanche Peak Steam Electric Station) EA-08-028 On February 29, 2008, a Notice of Violation was issued for a violation associated with a White Significance Determination Finding involving a violation of the Unit 1 Technical Specification (TS) 3.8.1, AC Sources - Operating, which requires that while the plant is in Modes 1, 2, 3, or 4, two diesel generators (DGs) capable of supplying the onsite Class 1E power distribution subsystem(s) shall be operable. From November 1, 2007, through November 21, 2007, while the plant was in Mode 1, one of the two DGs capable of supplying the onsite Class 1E power distribution subsystem(s) was inoperable, and action was not taken to either restore the DG to an operable status within 72 hours or be in Mode 3 within 6 hours and Mode 5 within 36 hours Specifically, Emergency Diesel Generator (EDG) 1-02 was made inoperable as a result of painting activities due to paint having been deposited and remaining on at least one fuel rack in a location that prevented motion required to support the operation of the EDG. This condition caused EDG 1-02 to fail to start during a surveillance test on November 21, 2007 Source unknown. All rights reserved. This content is excluded from our Creative Commons license. For more information, see http://ocw.mit.edu/fairuse. Page 11

Summary Even though nuclear plants are performing to high capacity levels for the last 5 years - issues remain. Safe operation requires constant vigilance, attention to detail and strong NRC oversight to assure that complacency does not set in. Role of industry NEI and EPRI are important to resolution of generic issues to assure balance. Page 12

MIT OpenCourseWare http://ocw.mit.edu 22.091 Nuclear Reactor Safety Spring 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.