STATE OF NORTH CAROLINA E DEPARTMENT OF ADMINISTRATION AUGUST 28, 1995 PURCHASE AND CONTRACT DIVISION D MARCH 23, 1995

Similar documents
STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

INTRODUCTION... 1 E.H. HOTCHKISS COMPANY... 3 SAMPLE HOTCHKISS FASTENERS... 5 JONES MANUFACTURING COMPANY... 40

SPECIFICATION FOR FILTERS, AIR (HVAC) (This specification is released for procurement purposes until revised or rescinded.)

MM-L-751H August 13, 1970 SUPERSEDING Int. Fed. Spec. MM-L-00751G(Army-ME) July 3, 1967 and Fed. Spec. MM-L-751C May 20, 1942 FEDERAL SPECIFICATION

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

PROCUREMENT SPECIFICATION FOR CNP19 CHERRY RIVETLESS NUT PLATE

Downloaded from

RADIAL GATES USES CONSTRUCTION FEATURES FACE PLATE SEALS

SECTION METAL ATHLETIC SPORT LOCKERS

FREE STANDING WORK STATION JIB CRANE

September 2012 / M&H C502 / Model 129

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies.

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

9900 SERIES SECTION LECTURE ROOM SEATING & TABLET ARM SPECIFICATIONS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

KEY PORT VALVE SERIES 400 ECCENTRIC VALVES Compact Size. Light Weight. UL Listed. AGA and CGA Approved. Bulletin

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR RUBBER-SEATED BUTTERFLY VALVES 3 INCHES THROUGH 72 INCHES ANSI/AWWA C504 Class 150/250 December 2012

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

COMMERCIAL ITEM DESCRIPTION PINTLE ASSEMBLY, TOWING, MANUAL RELEASE, , AND LBS CAPACITY

QQ-A-250/11F August SUPERSEDING QQ-A-250/GEN. August 27, 1971 FEDERAL SPECIFICATION SHEET ALUMINUM ALLOY 6061, PLATE AND SHEET

OPERATING MANUAL FOR 603, 604, 608 MACHINES

City of Storm Lake Fire Department Heavy Rescue Specifications

UNITED STATES COAST GUARD OCEAN ENGINEERING DIVISION WASHINGTON, D.C. JANUARY 2011 SPECIFICATION FOR THE MANUFACTURE

INVITATION TO BID PURCHASING DEPARTMENT P. O. BOX E. CENTRAL AVENUE THIRD FLOOR VALDOSTA, GEORGIA 31601

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

SECTION CENTRIFUGAL HVAC FANS

STATE OF NORTH CAROLINA DEPARTMENT OF ADMINISTRATION July 14, 2008 DIVISION OF PURCHASE AND CONTRACT Z July 14, 2005

VERTICAL LIFT FIRE/BLAST DOORS

SECTION PANELBOARDS

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

SECTION AXIAL HVAC FANS

SFI SPECIFICATION 6.3 EFFECTIVE: FEBRUARY 26, 2014 *

Draft Indian Standard SAFES Part 1 Specification (Fifth Revision)

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

COMMERCIAL ITEM DESCRIPTION CLAMPS, HOSE

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

REVISIONS LTR DESCRIPTION DATE APPROVED

Product Specifications for Aluminum Vertical Break Switches

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

Mtn View Aviation An AP Enterprises, LLC Company PO Box 31 Hubbard, OR MVA-B40C10M&O. Installation Instructions

ADJUSTABLE AIR PRESS

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

Easy Packer. Industrial Case Erecting, Packing and Taping System. User Guide

Mtn View Aviation An AP Enterprises, LLC Company PO Box 31 Hubbard, OR MVA-206C10M&O. Installation Instructions

Standard Specification for Threaded Couplings, Steel, Black or Zinc-Coated (Galvanized) Welded or Seamless, for Use in Steel Pipe Joints 1

Overhead transmission lines Spacers

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

Cal Pacific Airmotive, Inc.

SL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance

Downloaded from

TORQUE TESTERS FLEXIBLE-BEAM AND TORSION-BAR TYPES 5 OZ-IN TO 1000 LB-FT THIS PUBLICATION SUPERSEDES NAVAIR 17-20MU-03 DATED 1 MAY 1994

OPERATION AND CONSTRUCTION-AIRFLEX MAGNETIC CLUTCH

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Operation Care Service

/ CABLE TIES & WIRE FASTENERS /

Before installation these instructions must be fully read and understood

KEY PORT SERIES 400 ECCENTRIC VALVES

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

SPECIAL SPECIFICATION 6894 Communication Cabinet

268, 269 & 278. Concealed Door Closers

FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

FRONT LOADER REFUSE CONTAINER BID SPECIFICATIONS

FEDERAL SPECIFICATION TRUCKS, HAND, TWO WHEELED

KEY PORT SERIES 400 ECCENTRIC VALVES. Compact Size. Light Weight. UL Listed. CSA Certified. CSA Certified. UL Listed

KEY PORT SERIES 400 ECCENTRIC VALVES. Compact Size. Light Weight. UL Listed. CSA Certified. CSA Certified. UL Listed

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, SPDT, UNSEALED

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

Hawk Enterprises of Elkhart THE BRUTE Owner s Manual

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

QQ-A-200/1D 23 June 1983 SUPERSEDING QQ-A-200/1C August 20, 1970 FEDERAL SPECIFICATION SHEET

FF-H-1819 August 14, 1974 SUPERSEDING (See 6.10) FEDERAL SPECIFICATION HARDWARE, BUILDERS'; AUXILIARY LOCKS

PARTS LIST For PROMAXX Paving Breaker Models: MX60 & MX90

MV3-E Series Installation and Operation Manual for Hybrid Engine Controls

LIST OF EFFECTIVE PAGES Insert latest changed pages ; dispose of superseded pages in accordance with applicable regulations. NOTE : On a changed page,

DETAIL SPECIFICATION SHEET SWITCHES, TOGGLE, MINIATURE, LEVER SEAL, PANEL SEAL, FOUR POLE LOGIC LOAD TO 5 AMPERES

Operation Care Service

COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY

QQ-W-343F 19 November 1990 (TO SUPERSEDE) QQ-W-343-E November 13, 1981 FEDERAL SPECIFICATION WIRE, ELECTRICAL, COPPER (UNINSULATED)

CONSTRUCTION TOOLS CN45R B&C Eagle

INTER PLANT STANDARDIZATION STEEL INDUSTRY

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

e-cfr data is current as of January 5, 2017

Overhead transmission lines Tension clamp

Tooling Assistance Center

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

STATE OF NORTH CAROLINA I DEPARTMENT OF ADMINISTRATION SEPT 28, 2012 PURCHASE AND CONTRACT DIVISION H MARCH 16, 1998

Herpteraium SECTION VALVES GENERAL

1 SPECFICATIONS TRUCK MOUNTED, HIGHWAY, LARGE DEBRIS REMOVER INDEX

TECHNICAL SPECIFICATIONS OF HARDWARE & ACCESSORIES-ACSR PANTHER CONDUCTOR FOR TRANSMISSION LINE

BUSWAY Low Voltage (Pow-R-Flex)

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

Transcription:

STATE OF NORTH CAROLINA 7520-1E DEPARTMENT OF ADMINISTRATION AUGUST 28, 1995 PURCHASE AND CONTRACT DIVISION Supersedes 7520-1D MARCH 23, 1995 SPECIFICATION FOR STAPLERS, PAPER FASTENING (This specification is released for procurement purposes until revised or rescinded) SCOPE This specification covers the requirements for paper fastening staplers. It is not intended to cover all types and styles of staplers that are available, but only those generally used by state agencies and public education systems. I. CLASSIFICATION Staplers shall be classified by Type, Class, and Size as follows: Type I - Desk Type Class 1 - Heavy Duty, Tension Spring Size 1 - Full Strip, 4" Minimum Reach Class 2 - Medium Duty, Tension Spring Size 1 - Full Strip, 4" Minimum Reach Size 2 - Half Strip, 2 1/2" Minimum Reach Class 3 - Medium Duty, Compression Spring Size 1 - Full Strip, 4" Minimum Reach Size 2 - Half Strip, 2 1/2" Minimum Reach Type II - Lever Type, Heavy Duty Type III - Hand Held Type IV - Pliers Type Type V - Electric Class 1 - Full Strip Type Class 2 - Cartridge Type II. REQUIREMENTS

A. General Requirements 1. Identification The manufacturer's name or trademark and model number shall be stamped in a conspicuous place on each stapler. 2. Finish All metal surfaces shall be either painted or plated. If painted, sufficient coats of paint shall be applied and conform to the best industry standards of quality and method of application.plating, if used, shall be cadmium, chrome, or nickel and applied in accordance with the best industry standards of quality and method. All metal parts must have a corrosion-resistant finish or protective coating. The assembled stapler must be free of sharp or rough edges and other defects which may affect appearance or serviceability. 3. Springs Spring steel shall be used for all feeder springs, and heat-treated for sufficient hardness to provide for satisfactory functioning of the stapler. The spring shall be attached to the follower in a manner that will not cause a bending fatigue point and cause the spring to rupture or interfere with the smooth operation of the spring. 4. Staple Drivers Staple drivers shall be made of spring steel, and hardened equally over the whole length to an equivalent Rockwell hardness of 40 to 55 on the C scale. 5. Anvils Except for Types III and IV, case-hardened or hardened-throughout steel shall be used for the anvil, with a hardness of 85 (15-N-85) to 95 (15-N-95) Rockwell Superficial. 6. Bases Bases may be of either steel or zinc casting, but must be of adequate structural strength to withstand the evaluation and performance tests contained herein. Bases shall have durable pads or feet firmly affixed to the underside to prevent scratching or marring finished surfaces. 7. Follow-Blocks, Hinge Pins And Plungers (Staple Driver Actuator) Follow-Blocks are to be made of metal suitable for their function. Hinge pins are to be made of iron or steel with a Rockwell hardness of 65 to 80 on the B scale. Plungers (or other staple driver actuators) must be of iron or steel, as above, or of zinc alloys suitable for the design purpose. B. Specific Requirements Type I - Desk Type Class 1 - Heavy Duty, Tension Spring 1. A tension type spring shall be attached to the follower to feed the staples. Compression type springs are not acceptable.

2. The outside diameter of the spring shall be a minimum of 0.165" when measured with the coils at 90 degrees to the inner rails. 3. The clinching anvil shall be a separate unit, attached to, but not integral with the base. 4. The anvil must produce "Standard" and "Pin" clinch, with an easy and convenient method of reversing the anvil. 5. Full length inner rails are required 6. The staple driver shall be mounted with a minimum of two (2) rivets. 7. The base must swing back for tacking 8. A positive tacking latch is required. 9. The stapler must be all metal construction, except for the top cap which may be plastic. 10. A steel tie plate shall be attached to the front of the stapler to hold the channel together. 11. Staple capacity (Min.): 210, 1/4" leg length, standard staples. 12. Minimum reach: 4" Class 2 - Medium Duty, Tension Spring 1. A tension type spring shall be attached to the follower to feed the staples. Compression type springs are not acceptable. 2. The outside diameter of the spring shall be a minimum of 0.125" when measured with the coils at 90 degrees to the inner rails. 3. The clinching anvil shall be a separate unit, attached to, but not integral with the base. 4. The anvil must produce "Standard" and "Pin" clinch, with an easy and convenient method of reversing the anvil. 5. Full length inner rails are required 6. The base must swing back for tacking 7. The stapler must be all metal construction, except for the top cap which may be plastic. 8. A steel tie plate shall be attached to the front of the stapler to hold the channel together. 9. Staple capacity and size (Min.): Size 1: 210, 1/4" leg length, standard staples. Size 2: 105, 1/4" leg length, standard staples. 10. Minimum reach: Size 1: 4", Size 2: 2 1/2" Class 3 - Medium Duty, Compression Spring 1. A compression type spring shall be attached to the follower to feed the staples. 2. The clinching anvil shall be a separate unit, attached to, but not integral with the base. 3. The anvil must produce "Standard" and "Pin" clinch, with an easy and convenient method of reversing the anvil. 4. Full length inner rails are required 5. The base must swing back for tacking 6. The stapler must be all metal construction, except for the top cap which may be plastic. 7. Staple capacity and size (Min.): Size 1: 210, 1/4" leg length, standard staples. Size 2: 105, 1/4" leg length, standard staples. 8. Minimum reach: Size 1: 4", Size 2: 2 1/2" Type II - Lever Type, Heavy Duty 1. Full length metal inner rails are required. 2. The stapler base and arm must be all metal construction, except for a top cap or trim on the arm which may be plastic. 3. The clinching anvil shall be permanently mounted to the base. 4. The anvil shall produce the "Standard" clinch

5. The stapler shall be capable of using 1/4", 3/8", and 1/2" leg length heavy duty staples as a minimum. 6. The staple capacity shall be a minimum of 100 heavy duty staples. 7. The stapler must have an adjustable depth gauge. 8. Minimum throat depth: 2 3/4" Type III - Hand Held 1. The stapler shall be designed and constructed for hand-held stapling operations. 2. The clinching anvil shall be an integral part of the base. 3. The anvil must produce "Standard" clinch. 4. Full length inner rails are required 5. A steel tie plate shall be attached to the front of the stapler to hold the channel together. 6. The base must swing back for tacking 7. The stapler must be all metal construction, except for the top cap which may be plastic. 8. The staple capacity shall be a minimum of 105, 1/4" leg length, standard staples. 9. Minimum reach: 2 1/2" 10. Overall length: 5" maximum. Type IV - Pliers Type 1. The stapler shall be designed and constructed for hand-held stapling operations. 2. The clinching anvil shall be an integral part of the base, or affixed to the base with a minimium of two (2) rivits. 3. The anvil must produce "Standard" clinch. 4. Full length inner rails are required 5. The stapler must be all metal construction, except for the top cap and handle trim which may be plastic. 6. The staple capacity shall be a minimum of 210, 1/4" leg length, standard staples. 7. Minimum reach: 2 1/4" 8. Overall length: 8" maximum. Type V - Electric Class 1 - Full Strip Type 1. Electrical requirements: 115 volt AC 2. Power cord length: 5' minimum 3. The stapler shall be listed by Underwriters Laboratories 4. The stapler shall be designed and constructed for electric stapling operations. 5. The clinching anvil shall be affixed to, or be an integral part of the base. 6. The anvil must produce "Standard" clinch. 7. Full length metal inner rails are required 8. An adjustable depth gauge is required. 9. The manufacturer's name, make, model name or number, serial number, and the UL listing shall be clearly displayed on the stapler. 10. A pad, or feet, of resilient material shall be affixed to the base to prevent scratching or marring of finished surfaces. 11. The staple capacity shall be a minimum of 210, 1/4" leg length, standard staples. Class 2 - Cartridge Type 1. Electrical requirements: 115 volt AC or 24 volt DC

2. Power cord length: 5' minimum 3. The stapler shall be listed by Underwriters Laboratories 4. The stapler shall be designed and constructed for electric stapling operations. 5. The clinching anvil shall be affixed to, or be an integral part of the base. 6. The anvil must produce "Standard" clinch. 8. An adjustable depth gauge is required. 9. The manufacturer's name, make, model name or number, serial number, and the UL listing shall be clearly displayed on the stapler. 10. A pad, or feet, of resilient material shall be affixed to the base to prevent scratching or marring of finished surfaces. 11. Staples are supplied to the stapler in a cartridge, which must be easy to load. 12. The staple capacity shall be a minimum of 5,000 staples. IV. WARRANTY Staplers furnished under this specification shall be new and shall be guaranteed against defects in materials, workmanship, and performance in accordance with the manufacturer's standard warranty, except that in no event shall such coverage be for less than one (1) year from date of delivery to the ordering agency. Defective units shall be repaired or replaced during the warranty period at no cost to the owner or his representative. Contractors shall maintain a spare parts inventory of known high mortality parts or components for at least three (3) years after the expiration of the initial warranty. V. ACCEPTANCE EVALUATION AND QUALITY ASSURANCE A. Performance All staplers furnished under this specification must pass the performance tests outlined herein. Type I - Desk Type Set the clinching anvil to produce the "Standard" clinch. Insert a full strip (or half strip, depending on the size stapler) of 1/4" standard duty staples in the stapler. Drive and clinch at least 20 staples through two (2) sheets of 20 pound good quality sulphite bond paper. Repeat the test using 18 sheets and at least 50 staples. Examine staples for proper clinch, and for fracture and malformation. Observe for any malfunction of the stapler. Type II - Lever Type, Heavy Duty Type III - Hand Held Type IV - Pliers Type Clinch at least 50 1/4" heavy duty staples through 32 sheets of 20 pound paper. Repeat the test using 50 1/2" heavy duty staples and 90 sheets of paper. Examine the staples for proper clinch, and for fracture or malformation. Observe for any malfunction of the stapler. Follow the same test procedure as for Type I, except using 10 sheets of paper in lieu of 18 sheets. Follow the same test procedure as for Type I, except using 30 sheets of paper in lieu of 18 sheets.

Type V - Electric B. Rockwell Hardness Follow the same test procedure as for Type I, except using 14 sheets of paper in lieu of 18 sheets. Determine hardness with a rockwell hardness tester. In determining the hardness of the staple driver and anvil, convert the results obtained on another scale (Rockwell or Rockwell Superficial Tester) to the Rockwell C scales. VI. DELIVERY AND PAYMENT Delivery and payment for commodities under this specification shall be in accordance with the terms and conditions of the Invitation for Bids. The contractor shall be responsible for any packing, packaging, or protection required to insure delivery in undamaged condition. VII. ORDERING DATA (For Purchase & Contract use only) Purchasers should exercise any desired options offered herein and should specify the following information in the requisition and Invitation For Bids: 1. Title, number, and date of this specification 2. Types, Classes and sizes of staplers desired (See Section I, CLASSIFICATION) *****************************************************End of Document************************************************