DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

Similar documents
Long-Range Barrier Sensors

Beamtower Infrared barrier for large outdoor areas

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

GUIDE 212.V3 VSD VERTICALLY INSTALLATION GUIDE. The Protector TM. Light Curtain Series 4694

ENGINE PROTECTION BOARD PDM1

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

ECONOMISER SERIES E2T USER MANUAL

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DTS 412/512/624 SLIDING GATE MOTOR INSTALLATION MANUAL

Installation Instructions & Users Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

RESISTIVITY MONITOR/CONTROLLERS

SKC400U SLIDING GATE OPENER OWNER S MANUAL

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

MCD Pump Application Module

CARE-C Light Curtain Installation Instructions.

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Documentazione Tecnica SERIES. BARRIER Series Série Baureihe Serie GARD ROAD CAME 07/97 119G56 -GB G12000

Signet Pressure Transmitter

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

TOYOTA TACOMA TVIP V5

PROJECTOR LIFT MODEL SIH-300 INSTALLATION MANUAL

5 m. length high efficiency adhesive flexible LED strip from the TROLL family Flexiled.

OSLON 9 PowerCluster IR

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

EC DECLARATION OF CONFORMITY

Dragon 4 IR 12 PowerCluster

Model Specifications Code Price FOTOSWITCH

LED PROFILE - FLEXILED

Signet Pressure Transmitter

Typical applications are the control of barriers/booms in the parking and access control environments.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Teaching equipment designer and manufacturer

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

STR9 Monochromatic. Linear LED Wall Washer and Wall grazer

SR1V. Industrial Low Cost String Pot

Auto-IR36/48 Door Mounted Presence Sensor INSTALLATION GUIDE

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

MSB kw

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST Wiring diagram. Product description. Temperature controller. Order number

Heavy Duty. Enhanced NLS design eliminates the use of mechanical limit switch thus reducing mechanical wear and tear. Innovative counter weight spring

Outdoor Spotlights DesignPlan : L&L. Spot

Instruction Manual. IT-1 Infrared Thermometer

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

2001 Chevrolet Corvette ACCESSORIES & EQUIPMENT Remote Keyless Entry Systems - Corvette

User and Fitting Manual June 2008

Installation, Operation and Maintenance Manual

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

Bluefin Led Underwater lights.

CB-9 CONTROL BOARD INSTRUCTION MANUAL

TEL: G&C Electronics CC E. T.

TOYOTA PRIUS 2010 TVIP V5 PREPARATION

Compact Sliding Door Operator Dor-O-Matic 2900 Series

SIGNET Temperature Transmitter

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

GE Sensing & Inspection Technologies

AQUASWITCH AQUASWITCH & 760-A AQUASWITCH

Innovative Controls Inc. SL Series Tank Level Monitor

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

Emergency lighting units EM LED Light Engines

STREET HIGH EFFICIENCY LED STREET LUMINAIRES MADE IN THE EU

AWZ 110. AWZ 13,8V/1A/7Ah/LM

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

Signet Temperature Transmitter

EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

PerfectTilt RF Motorized Shutter User Manual

TECHNICAL MANUAL PERGOLAS

SPA 2017 Web. Bathed in Brilliance

VIRGO CONTROL UNIT TECHNICAL FEATURES

TOYOTA TACOMA 2005 TVIP V5 (RS3200 PLUS) Preparation

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

APPLICATIONS. The SAFEasy TM SG2 light curtains represent the natural evolution of the

Series A Electric Linear Actuators

7 OSLON +80 PowerAnna PCB White

INSTALLATION MANUAL IMMOBILIZER: IM125R-24A

Installation, Operation and Maintenance Manual

Vehicle Security System

Operating manual UPS - System

Vehicle Security System

INSTALLATION GUIDE. FCC ID NOTICE

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

TOYOTA TACOMA TVIP V5

Transcription:

DIGITAL NET 10 20 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS 15 1.5 METRES 3 STRAIGHT OR 7 CROSSED BEAMS 20 2 METRES 4 STRAIGHT OR 10 CROSSED BEAMS MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC GB INSTALLATION INSTRUCTIONS

DIGITAL NET 1 DIGITAL NET General Description This new-concept BARRIER is a real step forward in PERIMETER PRO- TECTION, offering greater reliability and ease of use. Basically, DIGITAL NET consists of a RECEIVING element and a TRANS- MITTING element which manage DOUBLE LENS optics with infra red beams. The controlling electronics have no trimmers, jumpers or any other components which could prejudice the reliability of the barrier. Every barrier function is set DIGITALLY, so that all the parameters can be read/controlled/modified really easily. Even the AUTOMATIC GAIN CONTROL, transparent for the user, is managed digitally. The wide AUTOMATIC CONTROL margin means that the barrier works just as well at 5 metres as at 80 metres, maintaining the same operational features over a wide thermal and environmental range. The synchronisation can be either linear or optical; the linear connection during the alignment phase means that the installation can be made by a single operator thanks to the DISPLAYS on both sides, so that the barrier can be ALIGNED WITHOUT any additional instrumentation. The barrier is equipped with integrated disqualification that can be managed both traditionally, with its N.O. RELAY OUTPUT, or through the setting of the relative function, which intervenes on the ALARM RELAY block. In this case, the disqualification output relay continues to operate normally; that is, it closes when there are adverse environmental conditions and opens during normal operating conditions. The double optical lenses reduce the false alarms to a minimum, maintaining a good optical range in all environmental conditions. The ALARM MEMORY is an innovational function, recording the last 20 beam interruptions; a very useful function in cases of repeated FALSE ALARMS. The barrier is fitted with everything necessary for correct installation, including cable fittings for the lower cap and the heating.

2 DIGITAL NET BARRIER COMPOSITION (Version 20) 1 Upper / Lower CAP screws 2 UPPER CAP O-RING screws 3 WALL support brackets 4 Upper CAP 5 Anodised ALUMINIUM bar 6 LENS unit (2 Lenses per beam) 7 WHITE (Rx) RED (Tx) spot 8 I.R. POLYCARBONATE Front panel 9 Tx or Rx MOTHER board 10 Lower CAP (with water drainage holes)

DIGITAL NET 3 INSTALLATION TIPS Remove the upper and lower barrier caps. Fix the barriers to the wall or the pole with the special fixtures. If possible, avoid positioning the receiver so that it faces the sun at dawn or sunset. Make the electrical connections. Make the alignment. Check that there are no branches or other moving obstacles between the barriers. Block the upper and lower cap with the special supplied screws. WALL MOUNTING WITH BRACKETS (DUAL KFP) A) Insert the bracket in the rear guides of the aluminium bar B) Tighten the bracket-fixing screw. C) Drill holes in the wall in correspondence with the holes on the upper and lower bracket and fix the brackets to the wall with the plugs. A B C POLE MOUNTING WITH BRACKETS (DUAL STAF) C A) Insert the bracket in the rear guides of the aluminium bar and tighten the bracket-fixing screw. B) Fix the other part of the bracket with the special screws. C) Fix the barrier to the pole, tightening the screws on the upper and lower bracket. A B

4 DIGITAL NET Mounting the I.R. plastic front panel CONFIGURATION a 1) Place the I.R. profile on the barrier alongside the heating elements PAYING ATTENTION to the CENTRAL TAMPER lever. 2) Fix the profile along ALL of the aluminium profile on one of the 2 sides. 3) Insert the supplied tool from the other side of the I.R. profile, pulling it. 4) slide the tool downwards by pressing with the free hand on the profile. 5) After about 40-50 cm. press right down on the I.R. polycarbonate with your hand. 6) Repeat the operation until the polycarbonate is completely inserted. 7) Slide the tool out from the bottom and close, mounting the caps on the ends. 8) Remove the protective film from the front of the I.R. profile. EXAMPLES OF DIGITAL NET INSTALLATIONS A B CONFIGURATION with CROSSING BARRIERS POLE MOUNTING (perimeter protection)

DIGITAL NET 5 TRANSMITTER CARD CONNECTIONS Tx 4 Tx 3 SYNC by WIRE Tx 2 Tx 1 (*): OPTIONAL connection improves immunity to disturbances in case of WIRED SYNCHRONISM

6 DIGITAL NET RECEIVER CARD CONNECTIONS Rx 4 Rx 3 SYNC by WIRE Rx 2 Rx 1 (*): OPTIONAL connection improves immunity to disturbances in case of LINEAR SYNCHRONISM

DIGITAL NET 7 PROGRAMMING OPERATING PARAMETERS The barrier operating parameters can only be set from the RECEIVER side, using the DISPLAY and the 2 BUTTONS underneath. The parameters are associated to variables from P1 to P6. Table 1 shows the modifiable variables and the minimum and maximum values associated to them. To set the operating values, proceed as follows: DISPLAY -BUTTONS+ 1. Press BOTH buttons (together); the DISPLAY indicates the first parameter P1. 2. Move from P1 to P6 by scrolling back and forth with the + and buttons. 3. Once the variable (parameter) TO BE MODIFIED is shown 4. Press BOTH buttons to access the value (FLASHING) and modify it with the + and buttons. 5. Press BOTH buttons to SAVE the new set value. 6. The display shows the last parameter MODIFIED/ Saved P1 P6. 7. To modify or read the other values, repeat from point 2. 8. To interrupt the modifications, do not touch the buttons and after a few seconds the sequence blocks. Table 1 - List of PARAMETERS P1 Optical range : 5 80 Metres (BARRIER OPTICAL installation distance) P2 N beams (*) : 2 10 (selectable) ADJACENT crossed or straight (10 Beams Vers. 20) P3 Alarm condition : 1,2,3 10 N beams to be INTERRUPTED to generate a valid ALARM condition P4 INTERVENTION -T : Adjustment of the intervention time, from 50 msec. to 990 msec. (reading x 10mS) P5 Reset - T : Adjustment of the RESET time, from 0.1 Sec. to 9.9 Sec. (reading x 0.1 S) P6 Disqualification : ON / OFF (if ON, blocks the ALARM RELAY in case of fog) (*) N.B.: CROSSED BEAMS can be used for OPTICAL distances of AT LEAST 20 METRES

8 DIGITAL NET BARRIER ALIGNMENT 1. Connect the synchronism (*), Receiver A and B with Transmitter A and B (2 wires are enough). 2. From the Rx side, set parameter P1 from 5 to 80 metres (the exact installation optical distance). 3. Exit from MODIFY PARAMETERS by pressing both buttons or by waiting for a few seconds. 4. PRESS THE ( ) BUTTON on the Tx or Rx card, the DISPLAY lights up and the L.E.D. of the 1 st beam starts flashing on both sides. 5. Manually rotate the lenses horizontally and use a screwdriver to make the vertical adjustment. 6. Set the DISPLAY reading to the maximum signal possible (end of scale 99) then change side and repeat. 7. When the adjustment of the current beam is completed, press + or to move to another BEAM. 8. Repeat from point 4, when the alignment is completed, exit from this function by KEEPING THE (-) BUTTON PRESSED. 9. This function is accessible from both sides (Rx and Tx). ALARM reading (recent events memory) 1. This function is only accessible from the Rx SIDE, KEEP the + BUTTON PRESSED for a few seconds. 2. The display shows 1 and the red L.E.D.s corresponding to the last ALARM (beams interrupted) light up. 3. Use the + and - buttons to access the last 20 ALARMS; 1= latest, 2=penultimate etc up to 20. 4. To EXIT from this function, keep the + button pressed for a few seconds. RECEIVER side DISPLAY TRANSMITTER side DISPLAY -BUTTONS+ -BUTTONS+ MEMORY BUTTON (+) (Display last 20 ALARMS) (Alignment) BUTTON (-) (Alignment) BUTTON (-) (*) N.B.: The LINEAR synchronism is only necessary during the ALIGNMENT PHASE, in order to read the values on both DISPLAYS. At the end of the alignment phase, the linear connection can be removed. The BARRIER functions perfectly with OPTICAL SYNCHRONISM. Linear synchronism gives greater operating stability, especially when there are several barriers which could interfere with each other or TV cameras with infra red illuminators. The wires also give greater security in the case of an attempted blinding with a similar barrier.

DIGITAL NET TECHNICAL FEATURES Available models: DIGITAL NET 10 - Height 1 METRE with 2 / 4 Straight / Crossed BEAMS DIGITAL NET 15 - Height 1.5 METRES with 3 / 7 Straight / Crossed BEAMS DIGITAL NET 20 - Height 2 METRES with 4 / 10 Straight / Crossed BEAMS Maximum recommended OPTICAL distance OUTDOORS Maximum recommended OPTICAL distance INDOORS 80 Metres 200 Metres Minimum INSTALLATION distance Minimum OPERATING distance for CROSSED BEAMS FUNCTION 5 Metres 20 Metres Horizontal alignment adjustment ± 90 Vertical alignment adjustment ± 20 BARRIER LOGIC power supply (version 20) 11-16 VDC 150 ma HEATING power supply (vers. 10 / 15 / 20) 24 VAC (20 / 40 / 40) W Protection rating IP 54 Operating temperature -25 to +55 C OTHER FEATURES Automatic gain Control with DIGITAL control as standard Linear or optical synchronism with automatic control INTEGRATED disqualification for fog or other adverse atmospheric conditions Double optics with infra red lenses for high immunity to sunlight TAMPER PROTECTION on upper cap, lower cap and I.R. front panel Events memory (last 20 ALARMS) BEAM LEDs and DISPLAY with automatic shutdown after 60 seconds of button inactivity BARRIER OUTPUT: ALARM N.C. RELAY CONTACT (only Rx side) DISQUALIFICATION N.O. RELAY CONTACT (only Rx side) TAMPER TAMPER N.C. CONTACTs

Via Vinca, 7 40016 S. Giorgio di Piano (BO) Tel. +39 051 665 00 71 Fax +39 051 665 00 28 E-mail: info@optea.it www.optea.it