NS Feeder pillar up to 3200A

Similar documents
Key features. DESIGNS: - Conservator type - Hermetically sealed

Wall mounted switchgear

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

Intelligent Choice for Prestigious Buildings

COMPACT SUBSTATION GUIDE

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

MESG 12 / 17.5 / 24 / 36 KV

TECHNICAL SPECIFICATIONS OF PCC PANEL

Low Voltage Main Distribution Board

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

Compact NR630. NR100F to NR630F

DPX moulded case circuit breakers

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Gas Insulated Metal-clad Switchgear, HMGS!

Adak Behin Niroo. co.com

Moulded Case Circuit Breakers

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

MINIATURE CIRCUIT BREAKER

Steve Summers Region Sales Manager

Contents. We build a better future! MCC HCB

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

max pole for t=15 ms

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

CPG.0 Single busbar gas-insulated cubicles

with Vacuum Circuit Breaker HAF

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

DMX 3 -I 2500 switch disconnectors

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Polestar Compact 250A MCB Distribution Boards

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

MOULDED CASE CIRCUIT BREAKERS BC160N

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

PowerCube type PB. Pre-assembled modules and enclosures for constructing medium voltage switchgear

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Electrical contractors solutions brochure

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Gas Insulated Switchgear

University of Houston Master Construction Specifications Insert Project Name

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

power made simple kva RANGE Performance I Durability I Serviceability

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

Metal Clad Switchgears

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Air Circuit Breakers

BETA Low-Voltage Circuit Protection

Memshield - ACB Ratings & Specifications

Metal Clad Air Insulated Switchgear

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

B kv T&D GAS INSULATED SWITCHGEAR

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Ed rev.0 CATALOGUE SWITCHGEAR 2015

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

MAIN INCOMER -1 (500 KVA TRF.)

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

Cascading & Discrimination

Selection Guide Motor Control Device Solutions

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

01 Spectra Plus - Introduction

SPECIFICATION FOR LOW VOLTAGE INTERNAL ELECTRICAL INSTALLATION (L-S1) CKE.LS (03).2016 CAWANGAN KEJURUTERAAN ELEKTRIK

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Air Circuit Breakers

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Circuit protection and control devices 0.5 to 6300 A

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

West Bengal State Electricity Distribution Co. Ltd.

Solar Power Switchgear & Energy Storage Renewable Energy Systems

: Material Description Quantity UOM

MoDPlus Din Distribution Boards

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Transcription:

NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique

Outdoor electrical distribution with advanced technology Merlin Gerin low voltage, NS Feeder Pillars for outdoor electrical distribution, incorporate technically advanced moulded case and air circuit breakers up to 3200A, providing important benefits including cost saving, flexibility and a high level of safety. Adding additional circuits A wide range of applications The NS Feeder Pillar is particularly suited to commercial and light industrial applications where there is a need for outdoor, low voltage supply. Providing a safe, flexible solution with individual monitoring and protection, ensuring efficient management of the LV electrical distribution network.

Cost savings All weatherproof outdoor enclosures allow the equipment to be located in any outdoor environment, freeing up valuable indoor floor space whilst retaining remote operation and control. There are a wide range of metering instruments available for monitoring the unit locally or remotely, ensuring efficient operation. NS Feeder pillars are available as part of a package substation with transformers and MV switch or circuit breakers. Additional cost savings are achieved through direct coupling from the transformer to the NS Feeder pillar eliminating expensive cable runs. Safety ASTA certified, providing IP2X operator protection under all circumstances during operation, allowing electrical systems to be fully co-ordinated minimising electrical faults. In addition to the overload and short circuit protection, each breaker can be fitted with earth fault protection. Flexibility The modular design enables customisation for individual requirements, and has the flexibility to suit the changing needs of the LV distribution system. Maximum flexibility is achieved by the four pole busbar system up to 3200A and the Compact NS range of moulded circuit breakers of ratings up to 630A. As a complete unit, the NS Feeder Pillar will not only provide circuit protection, but the outgoing circuits can also be controlled individually via hardwired pilots or linked to the incoming breaker. Other add-on benefits include remote monitoring and status of each breaker and also remote operation through motor mechanisms. Ease of use and installation The NS Feeder pillar comes complete and factory assembled for easy installation in any outdoor location with bottom entry cable through individual gland plates. The cable space is protected by an earthed metal screen, and each breaker is fitted with cable shrouds to maintain IP2X operator protection when the screen is removed. Add on modules for compact NS include ammeters and earth fault protection Addition of new circuits is made easy, by utilising the cassette on the NS breaker allows the breaker to be positioned anywhere on the busbar system before being clamped, contributing minimum disruption of supply.

Product Features Operator protection to IP2X of BSEN 60529 Purpose built, weatherproof enclosure Four pole busbar system up to 3200A Outgoing ratings from 16A to 3200A Cable or flange connection to transformer Compact NS Breakers from 16A to 630A Compact C breakers from 800A to 10A Provision for inclusion in package substations Wide range of accessories Compact NS -Advanced technology in moulded case circuit breakers Compact NS incorporates rota-active breaking, with a response time of approximately 1ms. This meets the highest levels defined by BSEN 60947-2. Compact NS advanced technology also includes total Discrimination, which is simple to design and select. Accessories There are accessories for many functions with local and remote monitoring which include: Ammeters Voltmeters KWH meters MDI s Internal lamps 13A RCD sockets Street lighting circuits Anti condensation heaters Pillar lights on manual or door operated switches can be fitted to the integral feeder pillar instrument panel. Accessories to customise the range of circuit breakers to meet specific cabling and operational needs are also available. Instrument panel accessories Outdoor enclosures expertise With over 50 years experience, Merlin Gerin manufacture a range of feeder pillar enclosures of the highest durability. They are available in six sizes, are padlockable and made from 3mm sheet steel. Total quality is assured Merlin Gerin public distribution is quality approved for design/development production, installation and servicing of low voltage switchgear. BSEN 60529, IEC 529, BSEN 60439-1, BSEN 60947-2, BSEN ISO 9001. REGISTERED COMPANY ISO9000 CERT N 62 NATIONAL ACCREDITATION OF CERTIFICATION BODIES

Applications Hospitals, medical centres Education, universities, shopping centres, retail parks Business parks, office buildings

One - stop package substations Merlin Gerin can provide one stop engineered package substations, tailored to customer requirements. NS Feeder Pillar can be either ground mounted or transformer mounted to form part of a package substation, which encompass the range of Merlin Gerin transformers, MV switchgear and LV feeder pillars. Cost savings are achieved by reducing the foundation area, minimum cabling due to direct coupling of MV, LV and transformer equipment and reduced time commitment needed by the customer. Tailored configurations include: NS Feeder Pillars up to 3200A Transformers from 315kVA to 2000kVA Extensible and non extensible Ringmaster and MV switchgear. Automation and monitoring systems Weatherproof enclosures if required. Enclosures Stainless steel clad package substation for Hong Kong. Merlin Gerin range of feeder pillar enclosures are robust, durable and secure, providing all weatherproof and vandal resistant protection. Available in six sizes, these are padlockable and manufactured from 3mm sheet steel. The steel is shot blasted and zinc metal sprayed before being coated in electrostatically charged powder paint, and cured in an oven for a hard, high gloss finish. The enclosures accommodate a variety of interiors.these weatherproof enclosures are available in dark grey to BS 381C and IP33 as standard. IP54 can be achieved with the addition of filtered ventilation and door gaskets.

Selection of outgoing circuit breakers outgoing current Circuit breaker functional space used (mm) rating (A) reference 3 pole 4 pole neutral link 16 MGP016 105 140 35 MGP0 105 140 35 40 MGP040 105 140 35 63 MGP063 105 140 35 80 MGP080 105 140 35 100 MGP100 105 140 35 1 MGP1 105 140 35 160 MGP160 105 140 35 200 MGP200 105 140 35 0 MGP0 105 140 35 400 MGP400 140 185 45 630 MGP630 140 185 45 800 C800N 280 420 800A MO8 H1 560 560 1000A C1001N 280 420 1000A M10H1 560 560 10A C11N 280 420 1600A M16H1 560 560 2000A M20H1 560 560 00A MH1 560 560 3200A M32H1 560 560 Selection of incoming unit incoming current unit functional space used (mm) rating (A) 3 pole 4 pole 3200 M32 Masterpact air circuit breaker 665 665 3000 disconnector 665 665 00 M Masterpact air circuit breaker 560 560 2000 M20 Masterpact air circuit breaker 560 560 2000 disconnector 560 560 1600 M16 Masterpact air circuit breaker 560 560 10 C11N Compact moulded case circuit breaker 280 420 1000 C1000N Compact moulded case circuit breaker 280 420 1000 Disconnector 560 580 800 M08 Masterpact air circuit breaker 560 560 800 C800N Compact NS moulded case circuit breaker 280 420 630 NS630 Compact NS moulded case circuit breaker 140 185 400 NS400 Compact NS moulded case circuit breaker 140 185 0 NS0 Compact NS moulded case circuit breaker 105 140 Enclosure selection shell size (mm) functional space (mm) Functional space for circuit breakers 2110 1995 1830 1715 1550 1435 1270 1155 990 875 710 595

Feeder pillar Circuit breaker feeder pillars Dimensions/mountings 1582 A feeder pillar (front view) Dimensions Doors A B cable & flange connected 1 740 710 2 1020 990 2 1300 1270 2 1580 1550 2 1860 1830 2 2140 2110 A B 310 Dimensions (mm) Doors A B C flange connected only 1 776 430 460 1 656 310 460 1 656 310 370 B cabinet Breaker 50 foundations (supplied by customer) C 1070 6 HOLES 16 dia 10 HOLES 32 dia 116 235 559 cable connected (end view) 235 support at transformer base B B 105 105 105 105 703 100 490 610 MAXIMUM C 100 30 100 50 1270 32 31 32 31 482 482 235 200 optional 200mm bolt on cable extension 6 HOLES 16 dia 10 HOLES 32 dia 116 559 100 482 flange connected (end view) 490 610 MAXIMUM dimensions A= refer to table B= refer to table C=to suit cable bending radius 50 fabricated foot (optional extra) B dimensions A= refer to table B= refer to table C= refer to table D= 450mm or 900mm 235 D 32 32 D

Circuit breaker feeder pillar Panel types - transformer connected offset & centre flange NS-FT3 LV distribution pillar supplies up to 3200A MDI Aux. Equip Specification Location Enclosure doors open Phase busbar rating Neutral busbar rating Short circuit level Incoming units Outgoing breakers Load indication Circuit protection Incoming cable entry Gland plates Outgoing cable entry outdoor (flange connected) enclosure to IP33 IP2X under normal operating conditions 3200A full or half busbar rating 50kA 1 second Masterpact ACB s Compact MCCB & NS also off-load disconnectors Compact MCCB s and NS provision - see accessories adjustable overload protection Below vertical undrilled below vertical Incoming unit reference rating (A) M32 ACB 3000 disconnector 3000 M ACB 00 M20 ACB 2000 disconnector 2000 M16 ACB 1600 disconnector 1600 C11N 10 M10 ACB 1000 C1000N 1000 M08 ACB 800 C800N 800 disconnector 800 NS 630 630 NS 400 400 NS 0 0 Accessories Pillar Padlocking devices Internal light 13A sockets Ammeters Voltmeters Kilowatt hour meters Maximum demand indicators Anti-condensation heater Thermostat Compact MCCB toggle padlocking device NS motor mechanisms terminal shrouds NS VIGI earth leakage module NS ammeter module NS current transformer module NS disconnectable neutral links cable termination spreaders C800-11 earth fault unit shunt release (MX) undervoltage release (MN) NS electronic trip unit (STR 22SE) NS selective trip unit (STR 23SE) NS universal trip unit (STR 53UE) Masterpact ACB instantaneous protection (STR 18) selective protection (STR 38) universal protection (STR 58) padlocking devices dialpact modules electrical operating mechanism undervoltage release instantaneous (MN) undervoltage release time delayed (MNR) shunt release (MX) closing release (XF) auxiliary switches

Circuit breaker feeder pillar Panel types - cable connected pillars NS-FC3 LV distribution pillar supplies up to 3200A Aux. Equip Specification Location Enclosure doors open Phase busbar rating Neutral busbar rating Short circuit level Incoming units Outgoing breakers Load indication Circuit protection Incoming cable entry Gland plates Outgoing cable entry Accessories outdoor (cable connected) enclosure to IP33 IP2X under normal operating conditions 3200A full or half busbar rating 50kA 1 second Masterpact ACB s Compact mccb & NS also off-load disconnectors Compact mccb s and NS provision - see accessories adjustable overload protection below vertical provision - see accessories below vertical As per NS-FT3 Incoming unit reference rating Max. No. of (A) SC 960mm phase neutral M32 ACB 3000 4 2 disconnector 3000 4 2 M ACB 00 3 2 M20 ACB 2000 2 1 disconnector 2000 3 2 M16 ACB 1600 2 1 disconnector 1600 2 1 C11N 10 1 1 M10 ACB 1000 1 1 C1000N 1000 1 1 M08 ACB 800 1 1 C800N 800 1 1 disconnector 800 1 1 NS 630 630 SC 300mm sq NS 400 400 SC 300mm sq NS 0 0 SC 185mm sq

Circuit breaker cabinets Panel types - transformer connected SM2 - C1 LV cabinet supplies up to 1600A SX - C3 LV cabinet supplies up to 3000A MDI N/E link aux. equip. N/E link Specification Location Phase busbar rating Neutral busbar rating Short circuit level Incomer outdoor IP33 enclosure tx mounted only up to 1600A up to 800A up to 50KA 1 second TP&N Off-load disconnector outdoor IP33 enclosure tx mounted only up to 3000A up to 1500A 50KA 1 second N/A Load indication Outgoing units Circuit protection Outgoing cable entry Outgoing cable size Gland plates provision - see accessories 2 - TP Compact C MCCB S Adjustable overload & short circuit below vertical up to 7 x SC 600mm sq undrilled provision - see accessories TP Masterpact ACB type H1 standard - STR28D overload & short circuit optional - STR38ST incorporating earth fault below vertical up to 7 x SC 600mm sq (800-1600A) up to 11 x SC 600mm sq (2000-00A) up to 3 x SC 960mm sq per phase &... up to 2 x SC 960mm on neutral (3000A only) undrilled General technical information Details cabinet pillars 800-3200 Masterpact & Compact 2400 1600 800 Enclosures and protection BSEN 60529 & IEC 529 circuit breakers Weatherproof, vermin proof and ventilated (IP33) standard standard Dustproof with filtered ventilation (IP54) no optional Personnel protection (enclosure doors open) (IP2X) IP2X IP2X Rated short time current withstand current Flange connected 1 second (ka) 50 35.5 50 50 35.5 Cable after 1 second (ka) 60 60 35.5 Standards listed are applicable to all Types and ratings Standards complied with are: (BSEN) 60439-1 60439-1 (BSEN) 60947-2 60947-2 Note: for ambient temperature in excess of those defined as normal in BSEN 60439-1, please consult the manufacturer.