oriolis Flow Meter ESRIPTION RT1000 The RT1000 oriolis mass flow meter identifies flow rate by directly measuring mass flow and density of fluids over a wide range of process temperatures with a high degree of accuracy. For homogenous fluids consisting of two components like sugar and water, the RT1000 oriolis system can derive the concentration and mass of each component based on fluid properties and density measurement. Furthermore, the unobstructed, open flow design makes it suitable for a variety of fluids such as slurries and other viscous, nonconductive fluids that are difficult to measure with other technologies. PPLITIONS The oriolis design and measurement principle allows the meter to be an exceptional device in measuring: Vegetable oils and fats Homogeneous suspensions and slurries dhesives, glues or binding materials oatings and hardeners yes, fragrances, vitamins and other additives OPERTION oriolis flow meters simultaneously measure mass flow rate, density and temperature. s fluid flows through the vibrating sensor tube, forces induced by the flow cause the tube to twist slightly. These small deflections are measured by carefully placed sensors. phase shift occurs between sensor signals that is directly proportional to mass flow rate. s the fluid density varies, the resonant frequency at which the tube vibrates changes which is also measured by the sensors. Larger sensors have two tubes that are vibrated in opposing directions in order to reduce the effect of process vibration on the flow measurement. Temperature is measured by an internal RT in order to calculate thermal effects on the tube vibrating frequency. ONTROLS SYSTEM INTEGRTION RT1000 transmitters provide a variety of means to integrate the meter s output into new and existing operations. The batch and PI functionality enables direct control of devices, such as valves, by use of digital or analog outputs. dditionally, programmable digital outputs can indicate low and high alarm conditions. Network options are available including EtherNet/IP, Modbus TP/IP and Modbus RTU. MINTENNE With no internal moving parts, the vibrating tube design has little impact on mechanical wear, resulting in a longer life expectancy and in fewer repairs than many other flow technologies. FLUI IGNOSTIS RT onsole software offers much more than configuration features. Users can obtain advanced data logging and performance trending analysis, as well as system verification provided by the unique HealthTrack feature, which captures critical operation parameters. VNTGES Highly accurate measurement of: Mass flow ensity erive concentration of homogenous liquids containing two components Open flow path Low maintenance operation Flexible integration options dvanced fluid diagnostic software RL-S-00128-EN-08 () Product ata Sheet
oriolis Flow Meter, RT1000 SPEIFITIONS System RS005, RS008 ±0.1% of reading ±0.05% of full scale RS018, RS025, RS050 ±0.2% of reading ±0.05% of full scale Uncertainty Mass Flow Rate (Liquids) RS100, RS200, RS300 (option 1) ±0.1% of reading ±0.025% of full scale RS100, RS200, RS300 (option 6) ±0.1% of reading* RS005, RS008 Mass Flow Rate (Gas) RS018, RS025, RS050 ±0.5% of reading ± 0.05% of full scale; 7:1 typical RS100, RS200, RS300 ±0.5% of reading ± 0.025% of full scale; 7:1 typical ensity RS005, RS008, RS018, RS025, RS050 ±0.12486 lb/ft 3 (0.002 g/cm 3 ) RS100, RS200, RS300 ±0.03121 lb/ft 3 (0.0005 g/cm 3 ) Repeatability RS005, RS008, RS018, RS025, RS050, RS100, RS200, RS300 ±0.05% of reading ± zero stability RS005, RS008, RS018, RS025, RS050 ±0.05% of full scale RS100, RS200, RS300 (option 1) ±0.025% of full scale Zero Stability RS100 (option 6) ±0.123 lb/min (3.35 kg/hr) RS200 (option 6) ±0.360 lb/min (9.79 kg/hr) RS300 (option 6) ±0.320 lb/min (8.71 kg/hr) Safety ertifications Ordinary Location UL61010 1/S 22.2 No. 61010 1:2010 ensity Measurement Flowing, referenced, PI, rix, aume and net oil onformance E * When flow rate is less than 10% of full scale, accuracy = ±[0.1% + (zero stability / flow rate) 100%] of rate. Flow Rate Specifications Sensors Nominal Line and Equivalent Pipe Size Number of Flow Tubes Flow Range Volumetric Equivalent 1g/cm 3 lb/min kg/hr gal/min l/h RS005 1/4 in., 1/16 in. 1 0 0.5 0 13.6 0.06 13.6 RS008 1/4 in., 3/32 in. 1 0 2 0 55 0.24 55 RS018 1/2 in., 3/16 in. 2 0 20 0 544 2.4 544 RS025 1/2 in., 1/4 in. 2 0 40 0 1088 4.8 1088 RS050 1/2 in., 1/2 in. 2 0 220 0 5987 26 5987 RS100 1 in. 2 0 1000 0 27,216 120 27,716 RS200 2 in. 2 0 1700 0 46,266 204 46,266 RS300 3 in. 2 0 5200 0 141,520 623 141,520 Maximum llowable Pressure by onnection Type O-Ring Face Sealing NPT lass 150 Flange lass 300 Flange RS005 2755 psi (190 bar) RS008 1800 psi (124 bar) Pressure RS018 3450 psi (238 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS025 3450 psi (238 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS050 3320 psi (229 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS100 2150 psi (148 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS200 2200 psi (152 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS300 275 psi (19 bar) 720 psi (49.6 bar) Wetted Materials Standard 316L stainless steel Fluid Range 40 392 F ( 40 200 ) Temperature ccuracy ±1.8 F (1 ) Repeatability ±0.54 F (0.3 ) Process onnections NSI Flange: 150 lb, 300 lb, (RS018 300) NPT; (RS015 200) 1/4 in. O-ring face sealing (RS005 RS008) onformance SME 31.3 Pressure Piping Hydro Test NE MR0175/ISO 15156 Page 2 RL-S-00128-EN-08
Product ata Sheet Transmitter Enclosure Power Requirements (Standard with Every RTN Transmitter) NEM 4 [IP-65]; powder coated aluminum, polycarbonate, urethane and stainless steel 115/230V ±15% 50/60 Hz 25 W maximum 20 28V mbient Temperature 14 160 F ( 10 70 ) onfiguration isplay RT Input nalog I/O uxiliary Power Frequency/Pulse Output igital I/O Industrial ommunications Modular Port 15 W maximum Four button HMI or RT onsole configuration 4 line 20 character; alpha-numeric; dot matrix; LE backlighting Standard (1 input) Optional (1 auxiliary input) Outputs Inputs uilt in 100 Ω Platinum RT within the sensor body dditional 100 Ω 3 wire Platinum RT input for the secondary RT is used by customers who want to be able to calibrate their RT Three 4 20 m (0 22 m capable), maximum load 500 Ω, approximately 16 bit resolution outputs; assignable to mass flow, volume, density, temperature, concentration, PI and similar measurements. User defined fault condition output value anywhere in the 0 22 m range. Two 0 5V inputs. 20k Ω input impedance, approximately 12 bit resolution Internal 24V supply, 100 m maximum (for batching functions, frequency output channel and like applications) One open collector transistor, user configurable as rate (3 khz max output), accumulator 0 10 Hz; PWM with 1 khz carrier User assignable to rate, any totalizer, PI, temperature, density, concentration or other similar measurements. Outputs Inputs Standard Optional Module Four 5 28V, 50 m maximum current draw (external pullup resistor required) Four 5 24V, 1k Ω impedance Modbus RTU (EI 485/RS485) Modbus TP/IP & EtherNet/IP Standard onfiguration Port larms Transmission istance Other Functions US 2.0 interface (through a Mini receptacle) for RT onsole software Six Hi/Lo larms; larm status on display by default, assignable to digital I/O (limit 2 or 4) and available via digital communications Up to 100 ft (30 meters); contact factory if longer length is needed atch control, PI control. User configuration of all I/O functions LE KITS The kits include the cable assembly, cable protector and sensor cable connection cover. R820476-20 R820476-35 R820476-50 R820476-70 R820476-100 R820477-20 R820477-35 R820477-50 R820477-70 R820477-100 Kit, PV jacketed cable 20 ft Kit, PV jacketed cable 35 ft Kit, PV jacketed cable 50 ft Kit, PV jacketed cable 70 ft Kit, PV jacketed cable 100 ft Kit, FEP jacketed cable 20 ft Kit, FEP jacketed cable 35 ft Kit, FEP jacketed cable 50 ft Kit, FEP jacketed cable 70 ft Kit, FEP jacketed cable 100 ft Temp range: 40 176 F ( 40 80 ) Temp range: 94 392 F ( 70 200 ) RL-S-00128-EN-08 Page 3
oriolis Flow Meter, RT1000 IMENSIONS Electronics Enclosure 8.25 in. Minimum Top learance RTN F E 0.19 in. iameter Mounting Holes E F 9.80 in. (249.9 mm) 8.00 in. (203.2 mm) 10.30 in. (261.6 mm) 4.30 in. (109.2 mm) 3.66 in. (93.0 mm) 8.32 in. (211.2 mm) Pipe Mount racket #8-32 UN-2 Screws Pipe Mount racket #8-32 UN-2 Screws Vertical Pipe Mount RTN Pipe Mounting Options Horizontal Pipe Mount E H G F Pipe racket imensions E F G H 5.50 in. (139.7 mm) 4.00 in. (101.6 mm) 1.11 in. (28.2 mm) 0.625 in. (15.9 mm) 1.25 in. (31.8 mm) 3.80 in. (96.5 mm) 5.25 in. (133.6 mm) 6.00 in. (152.4 mm) Page 4 RL-S-00128-EN-08
Product ata Sheet Sensor imensions, RS018 RS300 Threaded Ends Threaded Ends Flanged Ends Flanged Ends RS 050 100 200 300 RS 018 025 Sensor Nominal Size RS018 1/2 in. 13.6 in. (346 mm) 7.1 in. (180 mm) 8.5 in. (217 mm) 4.5 in. (113 mm) RS025 1/2 in. 16.0 in. (406 mm) 9.0 in. (228 mm) 10.0 in. (253 mm) 4.5 in. (113 mm) RS050 1/2 in. 18.5 in. (470 mm) 11.7 in. (296 mm) 15.9 in. (405 mm) 5.2 in. (131 mm) RS100 1 in. 23.2 in. (590 mm) 16.8 in. (426 mm) 27.6 in. (700 mm) 6.4 in. (163 mm) RS200 2 in. 26.4 in. (670 mm) 18.6 in. (472 mm) 28.6 in. (726 mm) 8.0 in. (203 mm) RS300 3 in. 40.9 in. (1040 mm) 28.7 in. (728 mm) 40.5 in. (1028 mm) 9.6 in. (243 mm) Sensor imensions, RS005 E F G Sensor Nominal Size E F G RS005 1/4 in. 5.90 in. (149.9 mm) 5.00 in. (127 mm) 1.00 in. (25.4 mm) 3.60 in. (85.3 mm) 7.93 in. (201.7 mm) 2.42 in. (61.6 mm) 1.23 in. (31.2 mm) RL-S-00128-EN-08 Page 5
oriolis Flow Meter, RT1000 Sensor imensions, RS008 Figure 1: RS008 dimensions Sensor RS008 Nominal Size 1/4 in. E F G H J 8.48 in. (215.3 mm) 5.72 in. (145.3 mm) 6.60 in. (167.7 mm) 1.50 in. (38.1 mm) 8.70 in. (221 mm) 2.67 in. (67.8 mm) 0.98 in. (24.9 mm) 4.65 in. (118 mm) 2.48 in. (63 mm) PPROXIMTE WEIGHTS Sensor Only RS005 5.5 lb 2.49 kg RS008 9.7 lb 4.4 kg RS018 15 lb 6.80 kg RS025 15 lb 6.80 kg RS050 26 lb 11.79 kg RS100 47 lb 21.32 kg RS200 90 lb 40.82 kg RS300 209 lb 94.80 kg Transmitter Only RTN 6.5 lb 2.95 kg ables Only R820*** 20 6 lb 2.7 kg R820*** 35 8 lb 3.6 kg R820*** 50 10 lb 4.5 kg R820*** 70 13 lb 5.9 kg R820*** 100 17 lb 7.7 kg Page 6 RL-S-00128-EN-08
Product ata Sheet OMPLETE REMOTE MOUNT METERING SYSTEM The complete remote mount metering system consists of the following; each component must be purchased separately: 1. Sensor 2. Transmitter 3. able assembly NETWORK OPTIONS RS-485 Network ll RT1000 meters come equipped an EI-485 port with Modbus RTU.. 10/100 ase-t Network n optional Ethernet module allows communications via Modbus TP/IP or EtherNet/IP. SOFTWRE UTILITY RT onsole software is a P based software that can be used to configure, operate and diagnose the RT1000 oriolis meter. dditionally, the software can log and graph fluid characteristics and parameters for historical comparisons. RT onsole software is included with the RT1000 oriolis meter. ESSORIES Please consult the factory for the availability, pricing and delivery estimates of additional accessories. SENSORS PRT NUMER ONSTRUTION Sensors 005 and 008 ONLY - - - - - - adger Meter oriolis Flow Meter Nominal Line and Equivalent Pipe Size RS 1/4 in., 1/16 in. 005 1/4 in., 3/32 in. 008 Wetted Material 316L Stainless Steel Process onnection Type NPT O-Ring, Face Sealing ody, 9/16-18 Threads O-Ring, Face Sealing Gland Electronic Mounting Options Remote Mount Transmitter ertifications General/Ordinary rea alibration/meter Uncertainty Liquids (Gases) Mass Flow: 0.1% (0.5%) ± 0.05% of FS zero stability; ensity: ± 0.002 g/cm3 3 Reserved None (Reserved) Specials Special ode (leave blank for non-custom orders) S NPT FSM FSF R G N XXX RL-S-00128-EN-08 Page 7
Sensor Part Number onstruction, Sensors 018 300 - - - - - - adger Meter oriolis Flow Meter Nominal Line and Equivalent Pipe Size RS 1/2 in., 3/16 in. (4.76 mm) 018 1/2 in., 1/4 in. (6.35 mm) 025 1/2 in., 1/2 in. (12.70 mm) 050 1 in., 1 in. (25.40 mm) 100 2 in., 2 in. (50.80 mm) 200 3 in., 3 in. (76.20 mm) 300 Wetted Material 316L Stainless Steel Process onnection Type NPT (018 200 sensors only) 150 lb SME 16.5 Flange (018 300 sensors only) F 300 lb SME 16.5 Flange (018 300 sensors only) F Electronic Mounting Options Remote Mount Transmitter ertifications General/Ordinary rea alibration/meter Uncertainty Liquids Mass Flow: 0.1% of reading ± 0.025% of full scale (100, 200, 300 sensors only) 1 Mass Flow: 0.2% of reading ± 0.05% of full scale (018 050 sensors only) 2 Mass Flow: 0.1% of reading (200, 300 sensors only) 6 Reserved None (Reserved) Specials Special ode (leave blank for non-custom orders) S NPT R G N XXX *Higher flange ratings and other process connection types can be provided. onsult factory for pricing and delivery estimates. TRNSMITTER PRT NUMER ONSTRUTION - - - - - adger Meter oriolis Transmitter RT Enclosure Type NEM 4 [IP 65] Transmitter Options isplay and Keyboard rea lassification General rea Electronic Mounting Option Remote Mount Transmitter ommunication Protocol Modbus RTU & Modbus TP/IP Modbus RTU (Standard on all models) Sensor onnection Ordinary reas Specials 3-igit Special ode (leave blank for non-custom orders) N K 2 R E M N XXX ontrol. Manage. Optimize. Trademarks appearing in this document are the property of their respective entities. ue to continuous research, product improvements and enhancements, adger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. 2015 adger Meter, Inc. ll rights reserved. www.badgermeter.com The mericas adger Meter 4545 West rown eer Rd PO ox 245036 Milwaukee, WI 53224-9536 800-876-3837 414-355-0400 México adger Meter de las mericas, S.. de.v. Pedro Luis Ogazón N 32 Esq. ngelina N 24 olonia Guadalupe Inn P 01050 México, F México +52-55-5662-0882 Europe, Middle East and frica adger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germany +49-7025-9208-0 Europe, Middle East ranch Office adger Meter Europe PO ox 341442 ubai Silicon Oasis, Head Quarter uilding, Wing, Office #209 ubai / UE +971-4-371 2503 zech Republic adger Meter zech Republic s.r.o. Maříkova 2082/26 621 00 rno, zech Republic +420-5-41420411 Slovakia adger Meter Slovakia s.r.o. Racianska 109/ 831 02 ratislava, Slovakia +421-2-44 63 83 01 sia Pacific adger Meter 80 Marine Parade Rd 21-06 Parkway Parade Singapore 449269 +65-63464836 hina adger Meter 7-1202 99 Hangzhong Road Minhang istrict Shanghai hina 201101 +86-21-5763 5412