OPTIMIZATION IN GENERATION FROM A HORIZONTAL AXIS WIND TURBINE VIA BLADE PITCH CONTROL AND STRUCTURE MORPHING

Similar documents
CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

International Research Journal of Power and Energy Engineering Vol. 3(2), pp , November, ISSN: x

Using energy storage for modeling a stand-alone wind turbine system

Starting of Induction Motors

Studies regarding the modeling of a wind turbine with energy storage

Converteam: St. Mouty, A. Mirzaïan FEMTO-ST: A. Berthon, D. Depernet, Ch. Espanet, F. Gustin

ACTIVE STATOR - A MORE EFFICIENT DRIVE TRAIN CONCEPT FOR A WIND TURBINE. Dr. Makhlouf Benatmane - Director Business Development

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Less need of Chinese rare-earths with large diameter direct drive

Analysis of Multistage Linkage Based Eclipse Gearbox for Wind Mill Applications

10 kw, 15φ Axial flux pancake generator for 2-blade Wind Turbine

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

RTDS Training course of IEPG

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Fabrication and Study of Vertical Axis Wind Turbine by Maglev Suspension

9. Examples of hydro energy conversion

CHAPTER 3 BRUSHLESS DC MOTOR

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Control Scheme for Grid Connected WECS Using SEIG

Modelling and Design of a 3 kw Permanent Magnet Synchronous Generator suitable for Variable Speed Small Wind Turbines

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

IJRASET 2015: All Rights are Reserved I. INTRODUCTION

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Wind Generation and its Grid Conection

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

GRID CONNECTED SOLAR WIND HYBRID POWER BASED ON IOT

World Journal of Engineering Research and Technology WJERT

Modeling and Simulation of Five Phase Inverter Fed Im Drive and Three Phase Inverter Fed Im Drive

CHAPTER 2 SELECTION OF MOTORS FOR ELECTRIC VEHICLE PROPULSION

Model: H kW. Features: 1. SCF Supercritical generator. 2. NSK bearings. 3. PLC integrated with Siemens module. 4. Low noise

University of L Aquila. Permanent Magnet-assisted Synchronous Reluctance Motors for Electric Vehicle applications

Comparison of different 600 kw designs of a new permanent magnet generator for wind power applications

J.D ENGINEERING WORKS

Extraction of Electrical Energy from Wind using Turbo-Ventilator

INTRODUCTION L-CAGS-E-170. Elevated output

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

(d) None of the above.

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

PHY 152 (ELECTRICITY AND MAGNETISM)

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

ing. A. Kragten December 2018 KD 668

Wind Energy Conversion System Connected With Grid Using Permanent Magnet Synchronous Generator (PMSG)

Floating Oscillator based Electric Generator using Mechanical Energy Harvesting

UNC-Charlotte's Power Engineering Teaching lab


Lightweight, Collapsible Wind Turbine

Lesson 16: Asynchronous Generators/Induction Generators

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

CHAPTER 5 ANALYSIS OF COGGING TORQUE

Conference on, Article number 64020

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

OFF GRID SOLAR INVERTER

Research and Reviews: Journal of Engineering and Technology

FD21-50 GHREPOWER. Version: 3.0

Analysis of Eclipse Drive Train for Wind Turbine Transmission System

Battery Charger for Wind and Solar Energy Conversion System Using Buck Converter

ELECTRIC DRIVES N.K. DE P.K. SEN

CHAPTER 1 INTRODUCTION

A Study of the Two Wheeler Retarder Type Dynamometer System

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

WIND ENERGY MODULAR TRAINER WITH CONNECTION TO MAINS DL WIND-A1G

Science 30 Unit C Electromagnetic Energy

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

MAJOR SYSTEM FUNCTIONS

DEVELOPMENT OF LABORATORY MODULE FOR SMALL WIND TURBINE CONTROL SYSTEM

World Scientific Research Journal (WSRJ) ISSN: Multifunctional Controllable and Detachable Bicycle Power Generation /

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

STUDY OF ELECTRICITY GENERATED BY CEILING FAN & CAR WHEEL

WIND POWERED MOTOR SYSTEM FOR TWO WHEELER VEHICLE APPLICATION

March Powerhouse Wind Ltd. Document Technical Summary for Thinair 102.

Handout Activity: HA773

K L E I N W I N D K R A F T kleinwind.at

Human Energy Generation and Electrical Signal Measurement

SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF

Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

HIGH EFFICIENCY ELECTRIC MOTOR

SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI

Modelling and Simulation of DFIG based wind energy system

ned100 Wind Turbine Generator a step towards your energy independence

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Braking Circuit of Small Wind Turbine Using NTC Thermistors under Natural Wind Condition

Modeling and Optimization of a Linear Electromagnetic Piston Pump

Chapter 8 Production of Power from Heat

Christof Deckmyn DEVELOPING AND TESTING POWER CONTROL FOR A WIND POWER STATION MODEL

An Efficient Approach towards Tidal Power Production Using Vertical Planar Motion

DESIGN AND IMPLEMENTATION OF HYBRID REGENARATIVE SMART BLDC MOTOR DRIVE ELECTRIC VEHICLE

Transcription:

OPTIMIZATION IN GENERATION FROM A HORIZONTAL AXIS WIND TURBINE VIA BLADE PITCH CONTROL AND STRUCTURE MORPHING PROJECT REFERENCE NO. : 37S1312 COLLEGE : SIDDAGANGA INSTITUTE OF TECHNOLOGY, TUMKUR BRANCH : ELECTRICAL AND ELECTRONICS ENGINEERING GUIDE : DR. K.P.SHIVAMURTHY STUDENTS : JAINENDRA MISHRA MAHENDRA SINGH SENWAR SINDHU RAVINDRA B SOURABH KUMAR Introduction: The world is at an energy-crisis where the fossil fuels are depleting rapidly and there is a dire need to find alternate sources of energy. The rate of energy demand has increased exponentially during the last decade. Wind power is known to be the most widely used renewable energy source. It is currently responsible for about 1.5% of the world s electricity use. Due to this major reason, it has become important for the world to develop technologies in order to maximise the harnessing of wind power. Keeping this in mind, this project aims at producing electricity for the low wind speed rate of Tumkur. This wind turbine has been specifically localized since the winds at Tumkur usually are at a speed of 3 5 m/s. The wind turbine that is being developed is set to rotate at around125 rpm. The generator rotates due to the constant motion of the blades of the wind turbine. Since the rpm of the blades are going to be low, the speed is increased by the use of a gear mechanism. Since commercially available generators are not suitable for the requirements of the project, the generator has been customdesigned. The generator used in this project is an Axial Flux generator. This is set to run at nearly twice the speed of the blades. The blades are designed in such a way that they have a unique twist, which enables maximum wind to be harnessed when in running condition. The non-uniform alternating current is then rectified to direct current. This is finally converted into alternating current, appropriate voltage of 230V using power inverters of 1450VA rating and step-up transformers. The output power of the generator is expected to be close to 1.5kW.

Project Description A wind turbine extracts kinetic energy from the wind and converts it into mechanical energy. This mechanical energy is then converted into electrical energy by the means of a generator. A wind turbine extracts maximum amount of energy when operating at optimal rotor speed. Since the wind is variable by nature, the optimal rotor speed also is. The speed range is expanded mainly to lower speeds, making it possible to track the optimal rotor speed starting from a lower wind speed. This will result in higher energy capture. The range of variable speed is limited and hence, in order to increase the speed of the generator, the possibility of using either controlled variable transmission or gearbox, is explored. These will help control the wind turbine over wide speed ranges in comparison to the conventional systems controlled by the generator torque. The important aspects of the project are as follows: Blade optimization: The kinetic energy of the wind should be optimally absorbed by the blades of a wind turbine. Variable pitch wind turbine (changing the angle of blades with respect to the incoming wind)will be designed and installed, which will solve this problem.wind turbine pitch control system can change incidence of rotor blades in a wind power generation system based on real-time wind speed for the purpose of adjusting output power, achieving higher utilization efficiency of wind power and providing protection for rotor blades. When wind speed is not higher than the rated speed, the blade incidence stays near the angle 0 (highest power point), which is similar to that of a generator with constant pitch, generating an output power that changes along with wind speed. Generator: The available commercial generators run at very high speeds, which is not desirable for this particular project. The generator that is designed is an Axial Flux generator. The Axial Flux generator is also a permanent magnet generator. Due to the high field strength, rare-earth magnets viz., Neodymium magnets were chosen. The field strength is 1.2T. The generator is double sided rotor which has permanent magnets embedded in the rotors and the stator containing coils is stationary.

Stator Rotor Complete generator Using bearings, it is mounted on a shaft and coupled with the hub of the turbine. It is a 3phase, star connected generator containing 9 coils and 12 poles on each rotor. The number of coils used in the stator was 9 coils, having 208 turns each, placed at 40 degrees to each other. Coils The generator was found to produce a voltage around 48V, running at a speed of 250 rpm. The generator is made small in size in order to prevent overloading at the hub, and on the shaft. Power Electronics Module: Since wind is a variable entity, it cannot be controlled. Hence, variable alternating current is expected as output. The entire module involves a complete AC to AC conversion, which basically has a variable AC to variable DC conversion. Bridge rectifiers are used to suit this purpose. A variable DC to fixed DC conversion which is carried out by a Buck-Boost Converter and then fixed DC to fixed AC conversion, taken care of by 2 inverter units having a rating of 725VA each.. In order to keep the frequency at a constant value of 50 Hz, the

frequency modulator is used and made sure that it remains constant. The voltage is stepped up to 230V from 48V. Results: The simulation of the airfoil to be fabricated, yielded the following results: Analysis shows that for a marginally low wind at Tumkur, the preferable airfoils are NACA 2412 and NACA 5518, and on comparison, NACA 5518 is best suited. Proposed Airfoil The final Wind turbine blade design parameters

Wind turbine output simulation analysis

Design of a DC AC inverter using Multisim Generator output of single phase at constant 100 RPM Inverter output (modified sine) when generator is at 100 RPM

Future Scope Human Monitor Interfacing The speed of the blades, the speed of the generator and the voltage produced can be monitored at a remote location with the help of HMI. This helps the user to know the instantaneous voltages and speed. Pneumatic Drive In case of winds with a speed of less than 3 m/s, the pneumatic drive which will consist of an air compressor-blower, can be used to rotate the winds in order to provide the necessary speed of the blade and hence produce the required voltage