High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Similar documents
High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

Pressure switch for gas, GW 500 A4 GW 500 A4/2

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

Old documentation - Only for your information! Product is not available any more!

Special gas range Biogas range

Valve monitoring system VDK 200 A S02

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Manually operated safety shut-off valve HSAV HSAV/5

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Commonwealth of Massachusetts Approved Product Approval code G

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

The installation and maintenance of this product must be done under the supervision of an experienced

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Two-stage safety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Valve testing system VPS 504 for multiple actuators

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Max. particle size 50 µm Max. oil content of compressed air

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Surface-mounting Thermostats Series ATH-SW

Product features & Overview. KA Linear actuators

Protective cover with powder coating. Protective cover with directed oil flow (OD cover)

Angle Seat Globe Valve, Metal

Max. oil content of compressed air

ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. Electric thrust actuator ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. ARI-PACO 2G 1,6 D 1,6 kn

GEMÜ 205 Electrically operated solenoid valve

Pressure regulators E/P pressure regulators Series ED05. Brochure

Panel-mounted Thermostats

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Applications Profitronic 19 / Profitronic 19U

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Limit Switch Type 4747

Old documentation - Only for your information! Product is not available anymore!

Pressure Transmitter JUMO dtrans p30 Type

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Linear actuator. Product features. Overview. Solid metal housing. Constant positioning times under fluctuating loads

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Pressure transmitter JUMO dtrans p02

Pressure Transmitter JUMO dtrans p30 Type

GEMÜ 549 esydrive Motorized globe valve

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

GEMÜ 539 esydrive Motorized globe valve

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Combination controls CG 10

Differential Pressure Switch QBM81-

Angle Seat Globe Control Valve, Metal

Diaphragm Valve, Plastic

555 Connection code 80 / Valve body material code C2. Angle Seat Globe Valve, Metal Aseptic

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Control Valve, Metal. Options Versions according to ATEX for manual and pneumatic operation on request

Pressure sensor for liquid and gaseous media QBE620-P...

Angle Seat Globe Control Valve, Metal

MESSKO COMPACT SERIES OIL TEMPERATURE ORDERING SPECIFICATIONS.

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Angle Seat Globe Valve, Metal

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Thermostats for panel mounting Series ETH

Proportional pressure regulators MPPES

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Control and Terminal Box Type A21-**-*****

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Differential Pressure Sensors

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

N086, N186, N786. Pressure retaining valve, Plastic

Energy Supply Systems

Pressure Sensors. for liquid and gaseous media

Lined Butterfly Valve Pfeiffer Type BR 10a

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

3 Edition Product brochure GB AGA

Diaphragm Valve, Plastic

Transcription:

High- switch for gas, air, flue gases and combustion products 5.04 Printed in Germany Edition 01.18 Nr. 241 654 1 6 Technical description The switch is an adjustable switch as per EN 1854 (GW 6000 A4 as per DIN 3398T3) for burners. It is suitable for closing, opening or switching over a current circuit when the actual value deviates from the specified setpoint. The specified setpoint (operating point) is set at a setting wheel using a scale. Application Pressure monitoring in burner control systems Suitable for gases of gas families 1,2,3 and other neutral gaseous media, as well as air, flue gases and combustion products. Approvals EC type testing certificate as per: EC-Gas Appliances Regulation EC-Pressure Equipment Directive Approvals in other important gasconsuming countries.

Functional Pressure switch for applications involving excess. The counteracts the force of the setting spring on the micro-switch via the metal bellows. The switch does not require power assistance. Pressure switch The switching mechanism reacts to over and closes, opens or switches over a current circuit when the specified setpoint is overshot or undershot. All gas-carrying parts are made of 1.4541 stainless steel and, therefore, are suitable for: - applications involving operating s greater than 600 mbar - aggressive media such as sulphuric acid up to a concentration of 1.0 % by vol., humid - fluids (on request) Switching function As rises: 1 NC opens, 2 NO closes. As falls: 1 NC closes, 2 NO opens. Definition of switching difference p The switching difference p is the difference between the upper and lower switching s. COM 3 p 2 1 NO NC Pressure at meter Switching difference, p Setting tolerance Adjustment as falls Upper switching Rising Falling Lower switching GW A4, Design: Clear cover IP 54 IP 54 5 Protection against ingress of solid particles ø 1 mm Protection against access to hazardous parts with a wire, ø 1 mm Complete contact 4 Protection against a water jet. No hazardous conditions may result. GW A4, Design: Metal housing IP 65 IP 65 6 Protection against the entry of dust (dust sealed). Protection against access to hazardous parts with a wire, ø 1 mm Complete contact 5 Protection against a water jet from a nozzle directed at the unit (housing) from any directions No hazardous conditions may result (water jet). 2 6

Specifications Max. operating GW 500 A4 HP = 2 bar (gas) @ setting range 0.1-0.15 bar = 5 bar (gas) @ setting range 0.15-0.5 bar Pressure connection GW 2000 A4 HP = 5 bar (gas) GW 6000 A4 HP = 8 bar (gas) p+: centrally on underside of housing internal thread G 1/4 and Rp 1/4, Gas or air Temperature range Ambient temperature -15 C to +70 C Medium temperature -15 C to +70 C Storage temperature -30 C to +80 C Materials Housing lower section Switch Switching contact Metal bellows Hood Hood aluminium die casting polycarbonate standard: silver gold-plated (Au), suitable for DDCapplications: DC 24 V; 0,02 A 1.4541 (stainless steel) polycarbonate die cast zinc, powder coated Switching voltage AC eff. min. 24 V max. 250 V DC min. 24 V max. 48 V DDC application: DC min. 5 V max. 24 V Nominal current AC eff. 10 A DDC application: DC max. 20 ma Switching current AC eff. min. 20 ma max. 6 A with cos ϕ 1 AC eff. max. 3 A with cos ϕ 0,6 DC min. 20 ma max. 1 A DDC application: DC min. 5 ma max. 20 ma Electrical connection Standard at screw terminals via cable gland, M20x1.5 Special version plug connection for line sockets as pert DIN EN 175 301-803, 3-pin with contact IP 54 to IEC 529 (EN 60529), (clear hood) IP 65 to IEC 529 (EN 60529), (metal housing) Adjustment Setting tolerance Deviation With rising and installed in a vertical position. Optional rising or dropping adjustment on-site possible. Note switch point change if installation position changes.. ±15% switch point deviation based on the setpoint and with unit installed in a vertical position Permissible deviation of the set value ± 15 % in the service life test according to EN 1854 3 6

Dimensions [mm] 2.5 x 9 dia. deep for equipment plug as per DIN EN 175 301-804 IP 65 with metal housing, cable gland M 20 x 1.5 IP 65 with metal housing, plug-in connection for sockets in according to DIN EN 175 301-803 81 38,2 67,6 38,2 1 3 2 67,6 SW 21 SW 21 77 53,75 ø 4,2-0,2 77 53,75 ø 4,2-0,2 + + 114 G 1/4 G 1/4 38,5 38,5 38,2 59 18,5 76 53,75 (LK 76) G 1/4 72 71 SW 21 G 1/4 and Rp 1/4 connection + Made in Germany 4 x ø 4,2 M20 x 1.5 or plug-type connection for cable socket according to DIN EN 175 301-803 81 4 self-tapping cylinder bolts M3 x 14 slot 0.8 and cross slot to DIN 7962-Z2 4 self-tapping cylinder bolts M3 x 14 slot 0.8 and cross slot to DIN 7962-Z2 G 1/4 and Rp 1/4 connection gas or air SW = Wrench width G 1/4 and Rp 1/4 connection gas or air Installation position Standard installation position; if a different installation position is used, pay attention to the changed operating points: GW 500 A4 HP ca. ± 0,010 bar GW 2000 A4 HP ca. ± 0,020 bar GW 6000 A4 HP ca. ± 0,080 bar When installed horizontally, the switch switches at a higher When installed horizontally overhead, the switch switches at a lowe α When installed at an intermediate position, the switch responds if there is maximum upper or lower deviation w.r.t. the set reference value. 4 6

Designation 12 GW 500 A4 HP Au-M-V0 9 0 3 Pressure connection V0 Pressure connection G 1/4 position 0 Made in Germany ing example 6 Pressure switch design Pressure switch Adjustment range 0.1-0.5 bar Contact material Au Electrical connection Cable gland M20 x 1.5 G 1/4 connection V0; at position 0 GW 500 A4 HP [Au-M-V0] 12 Electrical connection M M20 x 1.5 cable gland G 3 Equipment plug Contact material Au silver, gold-plated HP High- Adjustment ranges GW 500 A4 0,1-0,5 GW 2000 A4 0,4-2,0 GW 6000 A4 1,0-6,0 Pressure switch type GW A4 Clear cover, PC, (IP 54) Pressure switch switches when the exceeds or drops below the adjusted setpoint. Metal housing, powder-coated (IP 65) GW A4/2 Pressure switch switches when the exceeds or drops below the adjusted setpoint. Accessories for switches Bestell-Nr. Kit: G3 equipment plug, 3-pin + E for GW A4 219 659 Line sockets, 3-pin + E grey GDMW for GW A4,GW A4/2 210 318 Fluorescent lamp assembly kit 230 V yellow 231 773 Fluorescent lamp assembly kit 120 V yellow 231 772 Display LED assembly kit 24 V yellow 231 774 Fluorescent lamp assembly kit 230 V green 248 239 Display LED assembly kit 24 V green 248 240 5 6

High- switch for gas, air, flue gases and combustion products Technical overview 1 bar = 1000 mbar = 100 kpa 10000 mm WS [Au-M-V0] ± 15 % Pressure switch GW 500 A4 HP 254 280 0.1-0.5 2 @ 0.1-0.15 bar IP 54 0,03 0,03 GW 2000 A4 HP 246 665 0.4-2.0 5 IP 54 0,05 0,10 GW 6000 A4 HP 246 159 1.0-6.0 8 IP 54 0,30 0,30 [Au-G3-V0] ± 15 % Pressure switch GW 500 A4 HP 254 285 0.1-0.5 2 @ 0.1-0.15 bar with line socket IP 54 0,03 0,03 GW 2000 A4 HP 254 286 0.4-2.0 5 IP 54 0,05 0,10 GW 6000 A4 HP 254 287 1.0-6.0 8 IP 54 0,30 0,30 [Au-M-V0] ± 15 % Pressure switch GW 500 A4/2 HP 254 285 0.1-0.5 2 @ 0.1-0.15 bar IP 65 0,03 0,03 GW 2000 A4/2 HP 254 286 0.4-2.0 5 IP 65 0,05 0,10 GW 6000 A4/2 HP 254 287 1.0-6.0 8 IP 65 0,30 0,30 [Au-G3-V0] ± 15 % Pressure switch GW 500 A4/2 HP 254 282 0.1-0.5 2 @ 0.1-0.15 bar with line socket IP 65 0,03 0,03 GW 2000 A4/2 HP 254 283 0.4-2.0 5 IP 65 0,05 0,10 GW 6000 A4/2 HP 254 284 1.0-6.0 8 IP 65 0,30 0,30 We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Karl-Dungs-Platz 1 D-73660 Urbach, Germany Telefon +49 (0)7181-804-0 Telefax +49 (0)7181-804-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-73602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 6 6