WPS60/S EP Series. Features:

Similar documents
WPS350/S EP Series. Features:

WPS100/S EP Series. Features:

WPS150/S EP Series. Features:

WPS250/S EP Series. Features:

WPS20/S EP Series. Features:

GMS350C/S EC Series. Features:

GMS200C/S EC Series. Features:

GMS100C/S EC Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

EP series WPS800S rpm,3-phase/5-wiring

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

EP series WPS100S-AU rpm,3-phase/5-wiring

EP series WPS150BS-AU rpm,3-phase/5-wiring

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

WPS1000 / WPS1000S. Features: EP Series

EC series GMS30CS-AU 50

WPS625 / WPS625S. Features: EP Series

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

WPS1250 / WPS1250S. Features: EP Series

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

TPD2250H6.3 TECHNICAL DATA

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

WCS2000 / WCS2000S. Features: WCS Series

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

WPS60 / WPS60S. Features: EP Series

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

DIESEL GENERATOR SET. 60 Hz FEATURES

WPS100 / WPS100S. Features: EP Series

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMP80PX/ Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

60 Hz FEATURES. Exclusively from your Caterpillar dealer

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

GMP400PX/ Features:

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

SIVASA Doosan Series. SD250 Technical Data

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

GMS1400C / GMS1400CS. Features: EC Series

GMS800C/ Features:

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGKT / / / / / / / / / / / /

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SETS

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGDLS / / / / / / / / /

APD-ULJ250. Standby Power

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

GMS100C / GMS100CS. Features: EC Series

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

Model NA 2 L

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

60 Hz FEATURES. Exclusively from your Caterpillar dealer

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

Model MP150 W W

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

Super Silent, Superior Life!

Better Soundproof, Better Life!

Rental Power QSB7 series engine

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

APD-NG400. NG Standby Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

Super Silent, Superior Life!

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

Rating Definitions and Conditions

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

130 KW / 165 KVA POWERED by

Transcription:

Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance free battery Lockable battery isolator switch Powder coated canopy (Only for Soundproofed sets) 50 radiator Oil pump on the engine Steel base frame with fork holes Vibration isolators between the engine/alternator and base frame Dry type air filter Base fuel tank for daily running Drain points for fuel tank Operation Manual / Specifications Model Length (L) Width (W) Height (H) Dry Weight kg WPS60 1904 798 1384 894 WPS60S 2650 1050 1550 1407 Notes: *** Dimensions and Weights *Prime Power Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without over load; Standard Reference Conditions Note: Standard reference conditions 25 C (77 F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Output Ratings Generating Set Model Prime Power* Standby Power** WPS60 60kVA/48kW 66kVA/53kW WPS60S 60kVA/48kW 66kVA/53kW Ratings at 0.8 power factor Ratings and Performance Data Engine Make & Model: Alternator Brand: Alternator Model: Control System: Circuit Breaker Type: Frequency & Phase: Perkins 1103A-33TG2 Leroy somer LSA42.3L9 Auto Gen Engine Speed: RPM 1500 Fuel Tank Capacity: litres WPS60 WPS60S Fuel Consumption: l/hr (100% ) Power -Standby Power 3 Pole MCCB 50Hz & 3PH 220 240 13.9 15.4 1/ 5

Engine model:1103a-33tg2 Engine Technical Data No. of Cylinders / Alignment: Cycle: 3 / Vertical in-line 4 Stroke Bore / Stroke: (in) 105/127 Induction: Cooling Method: Governing Type: Governing Class: Turbocharged Water cooled Electronic ISO 8528 G2 Compression Ratio: 17.25:1 Displacement: 3.3L Moment of Inertia: kg m² 25 Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg - Dry - Wet 12/Negative 12/65 420 438 Cooling System Capacity with Radiator: l 10.2 Capacity without Radiator: l 4.4 Power to coolant and lubricating oil: kw Power to Radiation: kw 10.0 11.0 35.0 38.0 Power to cooling fan: kw 1.2/1.2 Radiator Cooling Airflow: m³/min 89.0/89.0 External Restriction to Cooling Airflow: Pa N/A Designed to operate in ambient conditions up to 50 C (122 F). Contact your local PowerLink Dealer for power ratings at specific site conditions Performance Engine Speed: rpm 1500 Gross Engine Power: kw 55.0 60.5 BMEP: kpa 1333 1467 Lubrication System Oil Filter Type: Spin-On, Full Flow Total Oil Capacity: l 8.31 Minimum: l 6.2 Oil Type: API-CG4/CH4 Fuel System Fuel Filter Type: Replaceable Element Recoended Fuel: Diesel Class A2 Fuel Consumption: l/hr Prime 110% 100% 75% 50% WPS60 15.4 13.9 10.4 7.2 WPS60S 15.4 13.9 10.4 7.2 (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2) Oil Cooling Method: Water Exhaust System Air Systems Silencer Type: Industrial Air Filter Type: Dry element type Exhaust outlet size: 56 Silencer Noise Reduction Level: Maximum Allowable Back Pressure: kpa N/A 10 Combustion Air Flow: m³/min 3.8 3.9 Exhaust Gas Flow: m³/min Exhaust Gas Temperature: C 10.1 10.4 557 571 Max. Air Intake Restriction: kpa -clean filter -dirty filter The weights are approximate and without fuel. 5 8 2/ 5

Alternator model: LSA42.3L9 Alternator Physical Data Manufactured by: Leroy somer Model: LSA42.3L9 No. of Bearings: Single Insulation Class: H Winding Pitch Code: 2/3 Wires: 12 Ingress Protection Rating: IP23 Excitation System: SHUNT, AREP OR AVR Model: R220, R438 Alternator Operating Data Overspeed: rpm 2250min 1 Voltage Regulation: (Steady state) ±0.5% Wave Form NEMA = TIF: <50 Wave Form IEC = THF: <2% Total Harmonic content LL/LN: No load <3% on load <2% Radio Interference: Radiant Heat: kw (Btu/min) -WPS60 -WPS60S Alternator WPS60 WPS60S Performance Data: Data Item Motor Starting Capability* kva Short Circuit Ratio** % Reactances: Per Unit Xd X'd X"d 138/161.5 138/161.5 0.47 0.47 230 230 11.6 11.6 5.8 5.8 Voltage Technical Data WPS60 Voltage Prime: Standby: kva kw kva kw 380/220V 60 48 66 52.8 400/230V 60 48 66 52.8 415/240V 60 48 66 52.8 Voltage Technical Data WPS60S Voltage Prime: Standby: kva kw kva kw 380/220V 60 48 66 52.8 400/230V 60 48 66 52.8 415/240V 60 48 66 52.8 3/ 5

Control System PLC-7420 (Optional) FEATURES Microprocessor control, with high stability and credibility. Mains supply and generator operation monitoring. Indicating operation status and fault conditions. Multiple protections; multiple parameters display, such as pressure, temperature. Manual and automatic work mode selectable. Real time clock for time and date display, overall runtime display, 99 log entries. Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed. Counication with PC via RS485 or RS232 interface, using MODBUS protocol. Engine ECU is available. Coon USB cable is usable for parameter configuration. Multi-language is available. PLC-920 FEATURES Parameter configuration via RS-232 serial counication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers. 4/ 5

Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Trailer Lubricating System Exhaust System Cooling System Control System Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-7420 ATS 415/240V 400/230V 380/220V 220/127V 200-115V The following lists are optional by the needs of customers. Minor Repair / 1000 hrs optional No. Part Name Part No. Qty Remark 1 Fuel Filter 26560163 6 2 Oil Filter 2654403 6 3 Air Filter 26510337 5 4 BELT 2614B655 1 5 SEAL ROCKER BOX COVER 3681A057 1 6 GASKET CYLINDER HEAD 3681E049 1 7 THERMOSTAT 4133L507 1 8 FRONT OIL SEAL 2418F437 1 9 SEAL REAR END OIL 2418F704 1 If you have any question or inquiry, please contact PowerLink sales organization or contact: info@powerlinkworld.com Local Distributor Specification may change without prior notice. For more info, please contact PowerLink or your local distributors. /2013 1 st Edition 5/ 5