You have probably noticed that there are several camps

Similar documents
Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

Pump ED 101. VFPPA Variable Frequency Parallel Pump Analyzer

Save Thousands of Dollars Per Year!

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

20th. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Do You Need a Booster Pump? Is Repeatability or Accuracy More Important?

Electro-Proportional Terms and Definitions

Components of Hydronic Systems

Horsepower to Drive a Pump

Welcome to the SEI presentation on the basics of electricity

Best Practice Variable Speed Pump Systems

Propeller Power Curve

SpiritPFC Torque/Horsepower Comparison Dynamometer Test Date: 5/7/2006

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011-

Pump Control Ball Valve for Energy Savings

Dynamics of Machines. Prof. Amitabha Ghosh. Department of Mechanical Engineering. Indian Institute of Technology, Kanpur. Module No.

How to choose correct battery(s).

Electronic Paint- Thickness Gauges What They Are, and Why You Need Them

MOTOR SAMPLE PROBLEM #1 Low-Slip Drive Belts

Chapter 13: Application of Proportional Flow Control

Chapter 2. The Vehicle-Tank Metering System

Turbocharger Compressor Calculations

How to use the Multirotor Motor Performance Data Charts

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

Troubleshooting Pumps in a System

Technical Guide No. 7. Dimensioning of a Drive system

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Performance means how fast will it go? How fast will it climb? How quickly it will take-off and land? How far it will go?

Measuring Pump Efficiency with Mike Eglitis

PREMIUM-EFFICIENT MOTORS

DRIVE THE WATER CYCLE. January 10 TH 2013

Designing a Mechanically Adjustable Speed Drive for AC Motor Applications to Eliminate Vibrations Without Additional Harmonics

Hydraulic Drive Head Performance Curves For Prediction of Helical Pile Capacity

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

INSTRUCTIONS FOR TRI-METRIC BATTERY MONITOR May 8, 1996

Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

Why do the dots go where they do?

What you need to know about Electric Locos

Learning Objectives:

Compressed Air Efficiency: A Case Study Combining Variable Speed Control with Electronic Inlet Valve Modulation

Introduction: Electromagnetism:

Trading the Line. How to Use Trendlines to Spot Reversals and Ride Trends. ebook

ALTERNATING CURRENT - PART 1

The Mark Ortiz Automotive

Roehrig Engineering, Inc.

High- or Medium-Speed Generator Sets: Which Is Right for Your Application?

Product Manual. 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1. Planetary Gearbox Stepper

Variable Speed Pumping

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

A short explanation of the modifications made in a poor quality ECU remap

SHAFT ALIGNMENT FORWARD

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Ensuring the Safety Of Medical Electronics

Hydraulic energy control, conductive part

Non-BM Balancing Services Volumes and Expenditure

NOW INTEGRATED WITH MLM DESIGNED FOR VAV DIFFUSER SYSTEMS LINEAR CHARACTERISTICS NO REGULAR MAINTENANCE REQUIRED PRESSURE SENSOR AND CONTROLLERS

Actual CFM = VE Theoretical CFM

Primer. Stepper Motors

MECHANICAL ENGINEERING FORMULAE

The Magic of Electric Flying or. Volts and Amps for Dummies By John Wheater

PUBLICATION NEW TRENDS IN ELEVATORING SOLUTIONS FOR MEDIUM TO MEDIUM-HIGH BUILDINGS TO IMPROVE FLEXIBILITY

Power Factor Correction

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

A Theoretical Study in Maximizing Crude Unit Kerosene

OWNER S MANUAL SUPPLEMENT for Performance Computer with VFD display. New Features. Metric Operation. Metric/US config

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

PWV API 610 Vertical Turbine Pump VS6 (Can Type) VS1 (Sump Type)

Pocket guide to Air motors

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components

Door panel removal F07 5 GT

(Refer Slide Time: 1:13)

NEW CAR TIPS. Teaching Guidelines

THE TORQUE GENERATOR OF WILLIAM F. SKINNER

Underground Tank Applications Installation Guide

COMPARISON OF ENERGY EFFICIENCY DETERMINATION METHODS FOR THE INDUCTION MOTORS

AAFAME Presentation. Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas.

SW20 Coolant System Maintenance.

ExxonMobil Basestocks Industry Pulse Report

Taking the Guesswork out of Clamp Force Control

ELECTRIC SUBMERSIBLE DEWATERING PUMPS

Spacing and Pattern Effects on DU LQ of Spray Nozzles

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

LogSplitterPlans.Com

Fourth Grade. Multiplication Review. Slide 1 / 146 Slide 2 / 146. Slide 3 / 146. Slide 4 / 146. Slide 5 / 146. Slide 6 / 146

Combustion Gas Turbine Fuel Pumps. CIRCOR White Paper

SMC -50 Technology and Control Advances

Fourth Grade. Slide 1 / 146. Slide 2 / 146. Slide 3 / 146. Multiplication and Division Relationship. Table of Contents. Multiplication Review

Working through the electric motor replacement maze

Tutorial. Running a Simulation If you opened one of the example files, you can be pretty sure it will run correctly out-of-the-box.

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

Tolerance-Based Time-Current Coordination

Parallel coupled APP pumps

Working Principle of Power Saver as per Manufacture:

Using an SMC-50 Solid-State Smart Motor Controller for Pump Protection

FAN PERFORMANCE MODULATION

VALVES & ACTUATORS. 20th TECHNOLOGY REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. HOW MUCH PRESSURE Can a 150 lb. Flange Withstand?

Using the NIST Tables for Accumulator Sizing James P. McAdams, PE

FLOW RATE STATIC BALANCING Valves for radiators

Transcription:

Pump Ed 101 Joe Evans, Ph.D. Comparing Energy Consumption: To VFD or Not to VFD You have probably noticed that there are several camps out there when it comes to centrifugal pump applications involving variable frequency drives (VFDs). One group believes that every pump should have one, while another thinks that they should be banned altogether. And, of course, there is the middle ground that says it depends upon the pump and application. When we think of VFD control, the first thing that comes to mind is energy savings. There are, however, other benefits that can often justify the cost of this control technique, whether there are energy savings or not. For example, soft start and stop reduces mechanical and electrical stress while virtually eliminating water hammer. In some instances, this alone can double the life of a pump and motor. Single to three phase conversion and open delta current balancing are two other popular, non-energy related applications, and you still get soft start and stop as a bonus. But if saving energy is the key purpose, it is very important that we understand how to compare energy consumption in the same application during constant and variable speed control. Let s take a look at a simple (water based) constant pressure / variable flow (cp/vf) application that uses the same pump and motor operating under both control schemes. Motor, Pump, & Total Efficiency We will start by defining efficiency, since it is efficiency that will have a large influence on the amount of power consumed by either application. The efficiency of a typical machine is simply output power divided by input power. If a motor consumes 1-kW of electrical power and produces 1-hp (0.746-kW), its efficiency is 74.6 percent. The same is true for the pump. Since 1-hp is equal to 33,000- ft-lb/min, the following equation will give us the theoretical horsepower required (or generated) at any point on a pump performance curve: hp = (head in feet x flow in gpm x 8.33 lb/gal) / 33,000 ft-lb/min If you divide the theoretical horsepower by the actual horsepower measured during testing, the result is pump efficiency at that point. However, efficiency doesn t stop with the individual efficiencies. Anytime we couple a motor to a pump we have to look at the efficiency of both machines working together (total efficiency). For example, suppose we have an electric motor that is 90 percent efficient at its rated speed and directly couple it to a pump that is 80 percent efficient at its BEP. How do we calculate the total efficiency? One approach would be to calculate the average of the two efficiencies. Another might be to assume that the system would operate at the lower of the two. Unfortunately, neither method is correct the results would be quite a bit higher than the actual total efficiency. It turns out that the total, or system, efficiency is the product of the individual motor and Soft start and stop reduces mechanical and electrical stress while virtually eliminating water hammer. In some instances, this alone can double the life of a pump and motor. pump efficiencies. In our example, the total system efficiency at BEP is 72 percent (0.8 x 0.9). At any point on a pump s performance curve, total efficiency will be the product of the motor and pump efficiencies at that specific operating point. Another factor that can affect both motor and total efficiency is motor loading. The peak efficiency of a typical three phase motor occurs at about 75 percent to 80 percent of its rated load, but it will maintain a fairly flat efficiency curve between 60 percent and 100 percent when operating at rated speed. When loading drops below 60 percent, efficiency begins to drop, and will drop rapidly around 40 percent. This is not an issue in a typical, constant speed pump application as long as the horsepower required at minimum flow is at least 60 percent of rated motor horsepower. 18 APRIL 2007 www.pump-zone.com Pumps & Systems

180 160 140 44% 17.7 59% 18.7 68% 20.5 4 X 4 X 7A 6.75" Trim 25 HP / 3500 RPM 75% 21.2 60hz System Head in feet 120 100 21.6 22.1 40% 53% 61% 68% 72% 72% 80 14.7 kw 15.5 kw 17.0 kw 17.6 kw 17.9 kw 18.3 kw 60 Black data label values are hydraulic efficiency Blue data label values are BHP Purple data label values are total efficiency Red data label values are kw 40 0 100 200 300 400 500 600 700 800 900 Gallons Per Minute Figure 1 Constant Speed Figure 1 puts our discussion thus far into perspective. It shows a 4 x 4 x 7 end suction centrifugal pump with a manufacturerapproved flow range of 200-gpm to 800-gpm, operating in a constant pressure application. A pressure reducing valve (PRV) is employed to maintain pressure at 100-ft across a flow range of 200-gpm to 700-gpm. The system curve (red) ignores any downstream changes due to friction and takes the form of a simple horizontal line. The blue data labels above the performance curve show the actual horsepower required at each major flow point, and are based upon the hydraulic efficiency (black data labels) at that same point. As you can see, the system requires approximately 22.1- hp at 700-gpm and drops to about 17.7-hp at 200-gpm. This reduction in power is just what we would expect to see when a centrifugal pump is throttled at the discharge by a valve. Since the minimum load horsepower (17.7) is well above 60 percent, we can assume that motor efficiency (90 percent) remains relatively constant across the full range of flow. What we have discussed so far is the horsepower required at each point not the power required to produce that horsepower. The purple data labels below the system curve show the total efficiency at each flow point and assume a motor efficiency of 90 percent. In order to obtain the actual kw consumed, we could recalculate the horsepower based on total efficiency and multiply by 746, or just use the following equation: [kw = (hp x 0.746) / motor efficiency]. This equation uses the original horsepower measurement and also takes into account motor efficiency. The red data labels show the power, in kw, consumed at each major flow point. As you can see, they range from 18.3-kW at 700- gpm down to 14.7-kW at 200-gpm. Variable Speed Control In this version of the application, the control valve is removed and a VFD is employed to control pump speed and system pressure across the same range of flow. When we introduce a VFD into the system we are essentially adding another machine to the equation, so we have to take a look at its effect on the rest of the system. The VFD impacts the system in several different ways. The first is its own efficiency how well it converts AC to DC and then pulses that DC to emulate an AC wave form. Energy losses are mostly in the form of heat, and if you check the rated efficiencies of several high quality drives you will find that they range from about 97 percent to 99 percent. For our comparison, we will take the middle ground and assume that the drive in our example is 98 percent efficient. The second impact is due to the non-sinusoidal (pulsed) nature of the current supplied by the drive. This can give rise to harmonic losses in the motor and can result in an overall reduction in motor efficiency of about 1 percent. Since we will be Pumps & Systems www.pump-zone.com APRIL 2007 19

Pump Ed 101 using the same motor (90 percent efficiency) in this example, we will assume that harmonic losses will reduce its efficiency at rated speed and load to 89 percent. Finally, reduced motor loading due to decreases in speed can also affect motor efficiency, although the decreases can be much smaller than those seen at fixed speeds. This quantity is a bit harder to define because it varies by motor size. For example, a typical 100-hp motor will experience a drop in efficiency of about 2.5 percent when operated at 30-Hz (1/2 speed). Smaller motors, especially those under 10-hp, will experience a larger drop. From the information I have been able to obtain from several motor manufacturers, motors 10-hp and above under VFD control will experience no drop in efficiency down to 50 percent loading and only a small drop (1 percent) around 40 percent loading. In our example we will assume an additional 1 percent drop in motor efficiency (88 percent) at the two lowest load points. (This is a topic that should be addressed in greater detail by the motor and drive industry.) In Figure 2 we see the original fixed speed, 60-Hz curve plus the performance curves for the speeds produced at 55-Hz and 50-Hz. The colored data labels are horsepower required, while hydraulic efficiency, at full speed, is again shown in black. The point where the frequency curves cross the system curve is the flow point for that particular frequency at 100-ft of head. It might be more meaningful if we showed each individual frequency curve. But, since the typical VFD has a resolution of 1/100 of 1-Hz, the number of curves (1200) would make the graph unreadable. You will have to visualize those additional curves on your own. The tables below the system curve show the variable speed results for each major flow point. They include frequency to the nearest whole Hz, horsepower required, hydraulic efficiency, vf/ mtr efficiency (includes both drive and motor losses), total efficiency, and power in kw. For flow points where motor loading is greater than 50 percent, vf/mtr efficiency is equal to drive efficiency x motor efficiency (0.98 x 0.89 = 87 percent). At flow points where motor loading is less than 50 percent (200-gpm & 300-gpm), motor efficiency is reduced to 88 percent. If you compare the power required at 700-gpm, you will notice that the variable speed application uses about 3.5 percent more than the fixed speed example, even though the horsepower required is the same not exactly what we would expect from a power saving application. Fortunately, this is the only point on the system curve where this situation occurs, and it is a function of the lower vf/mtr efficiency (87 percent compared to 90 percent for fixed speed) and the fact that head is the same for both applications. API Service Pumps API-610: VS1 VS6 API-610 Services: Offshore Platform/Sea Water Lift (Crude Oil Transfer) Pipeline Booster Vertical Process LPG Transfer Refinery Service Pipeline Aircraft Fueling Light Hydrocarbon, High Vapor Pressure (Low NPSHA) Cooling Water Waste Water Secondary Recovery Cryogenic Liquid Premium Technology for Harsh Environments (888) 360-7865 sales@rentzelpump.com circle 154 on card or go to psfreeinfo.com circle 153 on card or go to psfreeinfo.com 20 APRIL 2007 www.pump-zone.com Pumps & Systems

180 4 X 4 X 7A 6.75" Trim 25 HP / 3500 RPM 160 14.3 44% 17.7 59% 18.7 68% 60hz 55hz 50hz System Head in feet 140 120 100 10.1 6.9 10.2 13.6 10.8 14.4 11.9 15.8 20.5 16.3 21.2 75% 16.6 21.6 22.1 80 49 hz 10.1 HP 50% hy eff 86% vf/mtr ef 43% tot eff 8.7 kw 51 hz 11.5 HP 66% hy eff 86% vf/mtr ef 57% tot ef 9.95 kw 53 hz 13.8 HP 73% hy eff 64% tot eff 11.8 kw 55 hz 16.2 HP 78% hy eff 68% tot eff 13.9 kw 57 hz 18.9 HP hy eff 70% tot eff 16.2 kw 60 hz 22.1 HP hy eff 70% tot eff 18.95 kw 60 0 100 200 300 400 500 600 700 800 900 Gallons Per Minute Figure 2 circle 128 on card or go to psfreeinfo.com Pumps & Systems www.pump-zone.com APRIL 2007 21

Pump Ed 101 But an interesting trend begins just below full flow. Even though vf/mtr efficiency remains lower at every flow point, the power required decreases quickly. At 600-gpm it is reduced by 9.5 percent, compared to fixed speed operation. At 500-gpm and 400-gpm, it is reduced by 21 percent and 31 percent, and at 300-gpm and 200-gpm, it is reduced by 36 percent and 41 percent, respectively. These rather large power reductions are explained by a slight variation of the equation we used earlier. The kw required at any point on the system curve is equal to 0.746 x ((Q x H) / (3960 x tot eff)). Flow (Q) changes equally in both applications, but, unlike PRV control, a reduction in pump speed also affects the other two variables. First, head is reduced with a corresponding reduction in speed, and kw is directly proportional to both head and flow at any point. For example, at 300-gpm operating head is reduced by 46-ft, and even at 600-gpm it is reduced by 14-ft. Second, hydraulic efficiency moves to the left with flow as speed decreases, and the kw required is inversely proportional to pump efficiency at those same points. At 300-gpm hydraulic efficiency is 59 percent under PRV control, but under VFD control it increases to 66 percent. (See my November 2006 column Preservation of Efficiency. ) Taken together, these two variables have a sizable impact on the power required at any flow point. A very important result of this comparison is the fact that a relatively small change in speed can result in a much larger reduction in power. Over the entire range of flow, speed varies by a maximum of 641-rpm (18 percent), but the maximum power reduction over that range is 6-kW (41 percent) compared to PRV control. Even at 500-gpm, a speed reduction of just 291-rpm (8 percent) results in a power savings of 3.7-kW (21 percent). Other Considerations The potential energy savings available through variable speed control depend, to a large degree, upon the pump selected for a particular application. BEP efficiency is important, but the range of that efficiency is equally important. In our example, BEP efficiency is a healthy 80 percent, but at midpoint on the system curve (350-gpm), it is still 64 percent at rated speed and about 70 percent at its variable speed. Remember that efficiency moves to the left with a reduction in flow, and that movement will result in higher efficiencies at lower flows. Another consideration during pump selection is the curve shape. Our circle 131 on card or go to psfreeinfo.com 22 APRIL 2007 www.pump-zone.com Pumps & Systems

example exhibits a rise in head of about 50-ft from full to minimum flow and allows a control range of 12-Hz. Although flatter curves can be ideal for circulation applications (vp/vf) where head is primarily a function of friction, they may not offer the control range needed for applications that require higher static heads. There are alternative VFD control techniques that can address these flatter curves, but with hundreds of pump models available from dozens of manufacturers, chances are you can find the proper curve shape for almost any application. BEP efficiency is important, but the range of that efficiency is equally important. Joe Evans is the western regional manager for Hydromatic Engineered Waste Water Systems, a division of Pentair Water, 740 East 9th Street, Ashland, OH 44805. He can be reached at joe.evans@pentairwater.com, or via his website at www.pumped101.com. If there are topics that you would like to see discussed in future columns, drop him an email. Finally, pumps must be matched to the actual conditions of the application. Unfortunately, many systems tend to be oversized and have a margin of safety that is often equal to the expected flow! The pump used in our example is sized for a maximum flow of 700-gpm and a projected typical flow of 400- gpm to 600-gpm. If the maximum flow remains the same but the projected typical flow is reduced to 200-gpm to 400- gpm, then a duplex system (consisting of two smaller pumps) would be a better choice. The control scheme could employ two VFDs for variable speed control of each pump and a PLC to supervise their operation. Another option would be to use a single drive that would engage an across-the-line starter and bring a constant speed pump on-line when flow exceeds 400-gpm. We will discuss these control options in detail in a future column. P&S See Us At OTC BOOTH # 4716 circle 129 on card or go to psfreeinfo.com Pumps & Systems www.pump-zone.com APRIL 2007 23