Security alarms, warning systems.

Similar documents
PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

J1 Plug Pin Identification

Ride On Locomotive. Installation Guide

Security and Keyless Entry Installation Guide ca 1051

Systems: Electronics

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER

J1 Plug Pin Identification

J1 Plug Pin Identification

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Installation Instructions

e-ask electronic Access Security Keyless-entry

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

ENFORCER TM 6201-IQ ELECTRONIC SIREN

PSM72H Push-Button Start Module

InteliCharger V 20A Intelligent Automatic Battery Charger

SECURITY DOOR CONTROLS

LINEAR ACTUATOR INDUSTRIAL DUTY LACT SERIES

GCU-10. Automatic Engine Control Unit Operators Manual

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

STARTER DISABLE/ KEYLESS ENTRY SYSTEM

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /



2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

AR12 & AR20 Wiring diagram (multifunction display)

DEEP SEA ELECTRONICS PLC

Remote Start with Keyless Entry Installation Guide ca5054

DEEP SEA ELECTRONICS PLC

FM SECURITY AND REMOTE START SYSTEM

DLA SERIES + ACCESSORIES

Switch Machines Installation & Wiring

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions

LINEAR ACTUATOR INDUSTRIAL DUTY 10A/B SERIES

Ultrasonic Sensor U-B

LINEAR ACTUATOR INDUSTRIAL DUTY LACT BALL SCREW DRIVE

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Price List May Realism is what we aspire to achieve. This List gives you an idea of what else we do.

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

AA4006 Speed Sensitive Trip Unit. User Manual

Professional Wireless Products

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Remote Start with Keyless Entry Installation Guide CA 5051

Aura CM-54i Surface Mount Illuminated Enclosure

FEB.20, 2003 COMMANDO MODEL FM-870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST872 1

LINEAR ACTUATOR INDUSTRIAL DUTY LACT ACME DRIVE SERIES

Troubleshooting Guide

DMX-A2-DRV Integrated Advanced Step Motor Driver

Model PRO 9246CH Installation Manual

2 Way Security and Keyless Entry Installation Guide ca 1553

60 Series Engine Controls

SECURITY SYSTEM INSTALLATION MANUAL

PROTEC P1300-S/P1350-S Siren & Light Controller

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

Electropneumatic Timing Relays Series 7000 Industrial

LINEAR ACTUATOR INDUSTRIAL DUTY 10A SERIES

Model 930 Power Control System Instruction Manual

3 Channel Remote Start / Keyless Entry System Installation Instructions

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

MM1 Installation Instructions

Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst

LAN Power Supply Module.

CSI-400 Installation Instructions

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS

Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Security and Remote Start Installation Guide for models: ca6553 ca6553sst

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152

Current Steering Module ECM0001

Security and Remote Start Installation Guide for models: ca6554

2005 Directed Electronics, Inc. Vista, CA N412V 01-05

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

CA-210 Installation Instructions

A6Z OPERATING MANUAL

CARM INTERNATIONAL TOWING MODULES

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

RAPID Environment Control INSTALLATION GUIDE. Ver 99C. RAPID Environment Control. Creep

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

Max. 30A 2 Coils Normal Open Contact Type. Positive Car : Ground, or. Max. 20A 2 Coils Normal Open Contact Type. Battery. Positive Car : Ground, or

LBC Series Battery Charger Instructions

Press and release the valet switch 3 times 1 Chirp - LED 1 flash

The House of Gate Automation

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

4 Channel Remote Car Starter With Full Feature Alarm System Installation Instructions

ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds

Transcription:

SIREN DRIVER BOARD. Free running siren activated by the application of a V DC power source. This module is capable of driving a maximum of 2 x 8 ohm 10W speakers and produces approximately 110 db at one metre. Security alarms, warning systems. Supply voltage - V DC. Output level - 110 db at one metre. Capacity - 2 x 8 ohm 10w horn speakers. Termination - 4 way screw terminal. Mounting - self-adhesive standoffs or housing. Reverse polarity protection on the V DC input. Back EMF diode protection on the speaker output. Red led indicates power is on and siren operating. +Vdc input MCM ELECTRICS PTY. LTD. LSP-PCBS1.PM4

FLASHER DC OUTPUT BOARD. On application of thev DC input, the output will be pulsed at 1HZ (maximum load of 1A). Security alarms, warning systems. Supply voltage Output level Capacity Termination Mounting - V DC. - Switching from gnd to V DC. - V DC @ 1A maximum. - 4 way screw terminal. - Self-adhesive standoffs or housing. Reverse polarity protection on the V DC input. Back EMF diode protection on the flasher output. Red led indicates power is on and output flashing. load MCM ELECTRICS PTY. LTD. LSP-PCBS2.PM4

FLASHER RELAY OUTPUT BOARD. On application of the V DC input, the output will be pulsed at 1HZ (maximum load of 1A). Relay will operate at a time constant of 0.5 seconds on and 0.5 seconds off. Security alarms, warning systems. Supply voltage - V DC. Output level - Switching from gnd to V DC. Capacity - V DC @ 1 AMP maximum Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A - Min. voltage and current 5V DC 0.1A Termination - 4 way screw terminal. Reverse polarity protection on the V DC input. Back EMF diode protection on the flasher output. Red led indicates power is on and output flashing. Voltage Free Contacts load Output V dc pulsed MCM ELECTRICS PTY. LTD. LSP-PCBS3.PM4

FUSE DISTRIBUTI BOARD. Upon application of the V DC in, there will be four individually fuse protected outputs rated at 2 AMPS each. Security alarms, any application requiring seperately fused supplies. Supply voltage Output Rating Termination Mounting - V DC. - V DC. at 2 AMPS. - 10 way screw terminal. - self-adhesive standoffs or housing. Individual 2 AMP fuses on all four outputs. vdc OUT1 OUT3 OUT2 vdc vdc vdc OUT4 MCM ELECTRICS PTY. LTD. LSP-PCBS4.PM4

AC SPDT RELAY BOARD. On application of the 16V AC or V DC input, the relay will operate until the power is removed. Security alarms, any application requiring the operation of a spdt relay. Supply voltage - 16V AC/V DC. Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A Termination - 5 way screw terminal. Mounting - Self-adhesive standoffs or housing Red led indicates power is on and relay is energised Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS5.PM4

DC SPDT RELAY BOARD. On application of the V DC input, the relay will operate until the V DC is removed. Security alarms, any application requiring the operation of a spdt relay. Supply voltage - V DC. Relay rating - Max. switching power 150W - Max. switching voltage 30V DC - Max. switching current 5A Termination - 5 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS6.PM4

AC DPDT RELAY BOARD. On application of the 16V AC or V DC input, the relay will operate until the power is removed. Security alarms, any application requiring the operation of a dpdt relay. Supply voltage - 16V AC/V DC. Relay rating - Max. switching power 60W - Max. switching voltage 220V DC - Max. switching current 2A - Max. Carrying current 3A Termination - 8 way screw terminal. Mounting - Self-adhesive standoffs or housing Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS7.PM4

DC DPDT RELAY BOARD. On application of the V DC input, the relay will operate until the V DC is removed. Security alarms, any application requiring the operation of a dpdt relay. Supply voltage - V DC Relay rating - Max. switching power 60W Max. switching voltage 220V DC Max. switching current 2A Max. carrying current 3A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. output led Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS8.PM4

CLUTCH RELAY BOARD. On power up the relay will not be energised. On application of +V DC to the +TR terminal or 0V to the -TR terminal the relay will toggle once. On subsequent triggering the relay will toggle again. Security alarms, any application requiring the use of multiple push buttons, keyswitches, coded entry units. Supply voltage - V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Min. voltage and current 5V DC 0.1A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates power is on and relay is energised. Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS9.PM4

TIMER BOARD. 1 of 2 Options: Delay to operate timer. Operate, delay to release timer. * Delay to operate: Link LK1 position 2. Upon application of a positive or negative trigger the relay will remain de-energised for a period of time dependant on the setting of the dipswitches. * Delay to release: Link LK1 position 3. Upon application of a positive or negative trigger the relay will energise energised for a period of time dependant on the setting of the dipswitches. Security alarms, any application requiring the operation of a SPDT relay for a period of time or after a specified time. Supply voltage- V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates relay is energised. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD.

2 Minimum Minimum Maximum Maximum Dipswitch Settings Dipswitch Settings Potentiometer Adjustments Potentiometer Adjustments Seconds Seconds 0 0 6 6 46 46 50 50 50 50 52 52 18 18 38 38 20 20 46 46 2 32 32 30 30 0 TIMER BOARD. TIMER BOARD. 1 3 4 Minutes Minutes 0 1 2 3 4 5 6 7 10 10 11 11 13 13 15 15 16 16 17 17 18 18 Minutes Minutes 1 2 3 4 5 6 7 8 11 11 13 13 14 14 16 16 17 17 18 18 19 19 Seconds Seconds 0 0 46 46 58 58 52 52 52 52 26 26 34 34 42 42 42 42 20 20 30 30 43 43 42 42 MCM ELECTRICS PTY. LTD. MCM ELECTRICS PTY. LTD.

FULL FUNCTI TIMER / CLUTCH BOARD. 1 of 2 Options: Delay to operate timer. Operate, delay to release timer. Clutch relay * Timer - Delay to operate: Link LK1 position 2. Upon application of a positive or negative trigger the relay will remain de-energised for a period of time dependant on the setting of the dipswitches. * Timer - Delay to release: Link LK1 position 3. Upon application of a positive or negative trigger the relay will energise energised for a period of time dependant on the setting of the dipswitches. * Clutch relay: Link LK1 position 1. On power up the relay will not be energised. On application of +V DC to the +TR terminal or 0V to the -TR terminal the relay will toggle once. On subsequent triggering the relay will toggle again. Supply voltage - V DC Relay rating - Max. switching power 150W Max. switching voltage 30V DC Max. switching current 5A Termination - 8 way screw terminal. Reverse polarity protection on the V DC input. Red led indicates relay is energised. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS.PM4

1AMP POWER SUPPLY BOARD. 1 Amp 13.7 Volts DC power supply, open collector outputs via 10 ohm resistors for Mains Fail and Mains On. Battery output for Battery backup. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - 16V AC. Output Voltage - Factory set to 13.7 Vdc. Battery Voltage - 13.7 Vdc (Current Limited). Termination - 8 way screw terminal. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. 10 ohm Mains on 0V 10 ohm Mains fail 0V Mains fail and Mains on output stage. Mains on Mains fail load MCM ELECTRICS PTY. LTD. LSP-PCBS13.PM4

MICROPHE PRE-AMP BOARD. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - V DC. Termination - 3 way screw terminal. Mounting - Affixed to electrical wall plate by MCM. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. Microphone Input input +V dc To amplifier MCM ELECTRICS PTY. LTD. LSP-PCBS14.PM4

1AMP POWER SUPPLY BOARD. 1 Amp 13.7 Volts DC power supply, open collector outputs via 10 ohm resistors for Mains Fail and Mains On. Battery output for Battery backup. Security alarms, any application requiring 13.7 Vdc at 1 Amp. Supply Voltage - 16V AC. Output Voltage - Factory set to 13.7 Vdc. Battery Voltage - 13.7 Vdc (Current Limited). Termination - 8 way screw terminal. Varistor across AC input, 2 Amp fuse protected DC output, Battery output is Current Limited for protection. Red led indicates Mains on. +RST - Not used. -TR - Negative trigger (0-3V). +TR - Positive trigger (7-V). Pot Adjustments position 1 position 2 position 3 LK1 RV1 SW1 Min Max Voltage Free Contacts MCM ELECTRICS PTY. LTD. LSP-PCBS15.PM4