circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

Similar documents
circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-...

Thermal Overcurrent Circuit Breaker 3120-F...

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal Overcurrent Circuit Breaker 3130

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Electronic circuit breaker EBU10-T

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

Magnetic and Hydraulic-Magnetic Circuit Breaker

High Performance Thermal Circuit Breaker

Thermal-magnetic Miniature Circuit Breaker 4230-T...

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

max pole for t=15 ms

Thermal-Magnetic Circuit Breaker 201/-WA

TMC 91H is now TMC 60 C Series

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Magnetic and Hydraulic-Magnetic Circuit Breaker

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

LK Position Switches TECHNICAL DATASHEET.

Selection Guide. Control Circuit and Load Protection

Electronic Circuit Breaker ESS20-0..

Control switch/load disconnect switch Series 8008

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

PD-Series Ground Fault Circuit Protection

Technical Information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Magnetic Overcurrent Circuit Breaker

Electronic Circuit Breaker ESS20

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Manual Motor Starters. Meta-MEC

Protection components

High Performance Thermal-Magnetic Circuit Breakers 410/520/

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

XT IEC Power Control Manual Motor Protectors

Ordering Information. Text PCB Power Relay G5LE

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

3 - Protection components Motor circuit-breakers

Special Purpose Fuses

Thermal Circuit Breaker / Switch Series 3131

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Thermal Circuit Breaker / Switch Series 3131

3VU13, 3VU16 Circuit-Breakers

MS General Information Extended Product Type: MS

UMBW-UL489 and UL1077 Listed

Control Circuit Protection

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

cor Long Run Experience

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Bulletin 190-M Compact Starters. Selection Guide

Essential equipment for all your requirements

G-Series. Circuit Breaker.

C60H-DC C curve. Catalogue numbers

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Circuit Breakers. DIN rail-mounted equipment protection

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Thermal Circuit Breaker / Switch Series 3131

DPX 1600 Electronic release

Circuit Protectors TBC05 E-04

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Series L9 UL489 Miniature Circuit Breakers

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

Protection Equipment. 5/2 Introduction

KT4 Manual Motor Starter

FL series position switches

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Ideal for use as a manual starter

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

SERIES MINIATURE SNAP-ACTION SWITCHES

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Thermal overload relay TF140DU and TF140DU-V1000

P-Series 11 to to to to to to to 1100 >1000 <25

Jtec 10kA Miniature Circuit Breaker

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

1489-M Circuit Breakers

Position switches FR series

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Miniaturized limit switches

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

Transcription:

Thermal Circuit Breaker, rotary knob actuation, -, - or 3-pole -pole standard version 3-pole type without front bezel/knob standard front bezel/knob Description Thermal circuit breaker -, - or 3-pole Supplementary protector for general industrial use Positively trip-free release Bezel/knob snap-on Easy actuation with gloves Front elements can be done by customer Standards IEC 6093 UL 0 CSA C. 3 GB 0 Applications High pressure cleaners Floor cleaning equipment Power tools Wood and stone working machines Equipment for building construction Industrial equipment Commercial kitchen appliances Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs Technical Data Rated voltage U e -pole AC 0 V / 0/60 Hz DC 3 V -pole AC 0 V / 0/60 Hz DC 60 V 3-pole AC Y/0 V / 0/60 Hz Rated current - / -pole 0.0 0 A 3-pole 0.0 A Conditional short - / -pole, AC 0 V 0.0 0 A: 000 A, SC (C) circuit c 3-pole, AC V 0.0 A: 000 A Degree of protection Accessible range IP 0 Terminal side IP 00 Dielectric strength 0 Hz > 00 V Impulse./0 µs > 000 V Insulation resistance DC 00 V > 00 MOhm Endurance (typical) Mechanical 0 000 cycles AC: x, cos phi 0.6 0 000 cycles DC: x, L/R = 3ms 0 000 cycles Overload IEC 6093 min. 0 cycles @ 6 x, cos phi 0.6 UL 0 min. 0 cycles @. x, cos phi 0. (OLØ) Admissible ambient 30 C to +60 C air temperature Resistance to vibration IEC 60068--6, Test Tc 0 60 Hz: ±0. mm 60 00 Hz: 0 G Shock resistance Type of tripping IEC 60068--, Test Ea 30 G / 8 ms Weight -pole g -pole 60 g 3-pole g Max. switching capacity -, -pole 0 A for switch only types 3-pole A (without bimetal) Thermal positively trip free

www.schurter.com/pg_8_9 TA3 Tripping Characteristics [ min ] [ sec ] 0'000 60 Type Rated current TA3 <3A (TC-), pole [ min ] [ sec ] 0'000 60 Type Rated current TA3 >3 0A (TC-) (3 pole, max. A) 30 0 `000 `000 3 pole Ambient temp. +3 C 30 0 `000 `000,,3 pole Ambient temp. +3 C 0 00 0 00 00 00 00 00 0 0 0 0 0 0 0, 0, Tripping time 0,3 0, 0,,0,3 3 8 0 Multiple of rated current [ x In ] Tripping time 0,3 0, 0,,0,3 3 8 0 Multiple of rated current [ x In ] The above tripping characteristics apply to symmetrical overloads on all poles on the TA3 only. At asymmetric overloads on multi-pole types, the tripping characteristic will change. If a -pole type TA3 is loaded at one pole only, the tripping current will be shifted by factor.0 (TC-). If a 3-pole type TA3 is loaded at one pole only, the tripping current will be shifted by factor.0 (TC-). To meet the above tripping characteristic at asymmetric overloads on multi-pole types, the value of the rated current of the CBE has to be multiplied by the factor mentioned above. Effect of ambient temperature The unit is calibrated for an ambient temperature of +3 C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. Ambient Correction factor temperature [ C] -pole -pole 3-pole 30 0. 0.6 0.6 0 0.8 0.8 0.8 0 0.90 0.90 0.90 +3.00.00.00 +0.03.03.06 +0.0.0.0 +60.06.06. Example for -pole type: Rated current at +3 C.0 A Ambient temperature +0 C Correction factor.0 Chosen rated current at +0 C ambient temperature: A x.0 =. A 3

Standard rated currents and typical internal resistance In [A] Ri [W] Z0 0.0 00.0 J0 0. 0.0 J0 0..0 J0.0 0.0 J. 0.30 J0.0 0.8 J. 0. J8.8 0.089 030 3.0 0.09 00.0 0.09 00.0 0.0 060 6.0 0.08 00.0 0.0 080 8.0 0.0 00 0.0 0.009 0.0 0.0086 0.0 0.00 0.0 0.006 60 6.0 0.006 80 8.0 0.00 00 0.0 0.00 unprotected poles (without bimetal). mw Approvals # of poles Rated currents Rated voltage AC Rated voltage DC UL UL 0 0.0 0 A 0 V 3 V 0.0 0 A 0 V 60 V 3 0.0 A Y/0 V UL CSA C. 3 0.0 0 A 0 V 3 V 0.0 0 A 0 V 60 V 3 0.0 A Y/0 V VDE IEC 6093 0.0 0 A 0 V 3 V 0.0 0 A 0 V 60 V 3 0.0 A Y/0 V CQC GB 0 0.0 0 A 0 V 3 V 0.0 0 A 0 V 60 V 3 0.0 A Y/0 V Actual information about approvals can be found on: www.schurter.com/approvals.

www.schurter.com/pg_8_9 TA3 Order Number of switched poles -pole -pole 3-pole Number of protected poles 0 0 0 3 P P P P P3 P P3 8 8 8 9 6 Basic type EFC EFT EBC EBT EBD EKC EKD Other versions on request TA3- EBT T F 0 C0 No other features Frontbezel and actuation knob Bezel Knob T black black N without bezel without knob Without thermal overload protection: code C00 With thermal overload protection: rated current (A) Bezel marking Surface Symbol F relief recessed I 0 N no marking no marking 0.0 Z0 0. J0 0. J0 0.3 J03 0. J0 0. J0 0.8 J08.0 J0. J. J.0 J0. J 3.0 030 3. 03.0 00.0 00 6.0 060.0 00 8.0 080 0.0 00.0 0.0 0 *.0 0 * 6.0 60 * 8.0 80 * 0.0 00 * 0ther rated currents on request. * 3-pole max. A

Dimensions TA3 -pole 9.6 9. 0 3. ø. 0.6 ø 3..6.3.3 6.3 x 0.8 mm. 8..9 33.8 Screw Type: x PT WN3 KA 3 x TA3 -pole 9.6 30. 0 3. ø. ø 3..6 0.6.9.3.3. 6.3 x 0.8 mm 33.8 Screw Type: x PT WN3 KA 3 x TA3 3-pole 9.6. 0 3. ø. ø 3..6 0.6.9.3.3. 6.3 x 0.8 mm 33.8 Screw Type: x PT WN3 KA 3 x 6

www.schurter.com/pg_8_9 TA3 Front bezel/knob Switching angle (38. -.) ø 38 R3 3 8 OFF ON - 3 Cut-out 0 90 0 0 ø 8. Mounting instructions Customer specific bezels/actuator designs possible