OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

Similar documents
BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

User Manual Rittal PMC UPS 6kVA

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Uninterruptible Power System

Uninterruptible Power System

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Uninterruptible Power System

Uninterruptible Power System

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual V1.0 MaxiFlex 3000

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

USER MANUAL ONLINE UPS

General Precautions. Personnel Precautions

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Liebert GXT MT+ User Manual VA Installer/User Guide

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

1. INTRODUCTION. Features:

1. Important Safety Warning

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

USER MANUAL DN / DN

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Limousin II User Manual

Pulsar Evolution 2200/3000/3000 XL

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

SCC-MPPT Solar Charge Controller

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

SCC-MPPT Solar Charge Controller

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

NEWTECH PRO X KVA DSP LCD 1/1 ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Solar Charge Controller

SCC-MPPT Solar Charge Controller

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

User Manual. PF0.9 6K/10K Online UPS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Installation and Operation Manual Back-UPS BX1100CI-CN

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

Back-UPS CS Back-UPS CS 350

Uninterruptible Power Supply

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Foreword

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

USER MANUAL MPS 1-5KW SERIES

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

PURE SINE WAVE DC TO AC POWER INVERTER

DC Master 24/ A

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

powerquality.eaton.com Eaton 9E 6-20kVA Page 1

CP900EPFCLCD User s Manual K

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Installation and Operation Back-UPS BX550CI-CN

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

Phoenix Inverter

Instruction manual. Electrobloc EBL 269

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

User Manual. Hybrid PV Inverter. Version: 2.1

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Battery Charger Series EASY Charger

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

OPERATION & MAINTENANCE INSTRUCTIONS

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual. 1P-1P 6KL/7.5KL/10KL Online UPS

Battery Charger. Series EASY Charger. User s manual

OPERATION & MAINTENANCE INSTRUCTIONS

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

POWERWARE User s Guide VA.

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

U n i n t e r r u p t i b l e P o w e r S y s t e m

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Transcription:

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A. 1000 PROTECT A. 1400 1

1 Notes on these Operating Instructions Duty to Provide Information These operating instructions will help you to install and operate the Uninterruptible Power Supply (UPS), PROTECT A. 1000 or PROTECT A. 1400, all referred to as PROTECT A. in this document, safely and properly, and for its intended purpose. These operating instructions contain important information necessary to avoid dangers during operation. Please read these instructions carefully prior to commissioning! These operating instructions are a composite part of PROTECT A. The operator of this unit is obliged to communicate these instructions to all personnel transporting or starting PROTECT A. or performing maintenance or any other work on the unit. Validity These operating instructions comply with the current technical specifications of PROTECT A. at the time of publication. The contents do not constitute a subject matter of the contract, but serve for information purposes only. Warranty and Liability We reserve the right to alter any specifications given in these operating instructions, especially with regard to technical data and operation. Claims in connection with supplied goods must be submitted within eight days of receipt, along with the packing slip. Subsequent claims cannot be considered. The warranty does not apply for damage caused by noncompliance with these instructions (such damage also includes damaging the "Q.A." warranty seal). AEG will accept no liability for consequential damage. AEG will rescind all obligations such as warranty agreements, service contracts, 2

etc. entered into by AEG and its representatives without prior notification in the event of maintenance and repair work being carried out with anything other than original AEG spare parts or spare parts purchased by AEG. Handling PROTECT A. is designed and constructed so that all necessary steps for start-up and operation can be performed without any internal manipulation of the unit. Maintenance and repair work may only be performed by trained and qualified personnel. Hotline If you still have questions after having read these operating instructions, please contact your dealer or our "Hotline": Phone: +49 (0)180 5 234 787 Fax: +49 (0)180 5 234 789 Internet: www.aegpss.de Copyright No part of these operating instructions may be transmitted or reproduced by any electronic or mechanical means without the express prior written permission of AEG. Copyright AEG 2006. All rights reserved. 3

1.1 Declaration of Conformity 4

2 Safety 2.1 Important Safety Instructions Read these operating instructions carefully prior to commissioning of the PROTECT A. UPS and observe the safety instructions! Only use the unit if it is in a technically perfect condition and always in accordance with its intended purpose, while being aware of safety and danger aspects, and in accordance with the operating instructions! Immediately eliminate any faults which could be detrimental to safety. The following pictograms are used in these operating instructions to identify dangers and important information: Danger! Identifies risk of fatal injury to the operator. Warning! Identifies risk of injury and risk of damage to the unit and parts of the unit. i Information! Useful and important hints for the operation of the UPS. 2.2 Safety Instructions for PROTECT A. This chapter contains important instructions for the PROTECT A. UPS. These must be followed during assembly, operation and maintenance of the uninterruptible power supply and the batteries. The UPS carries high voltage. Danger! The unit may only be opened by trained and qualified personnel. Repairs may only be carried out by qualified customer service staff! 5

The output may be live, even if the UPS is not connected to the mains supply, as the UPS has its own internal power supply (battery)! For health and safety reasons, the unit must be earthed correctly! PROTECT A. may only be operated with or connected to a 230 VAC mains with protective grounding using a mains connection cable with PE conductor (included in the delivery) that has been tested in accordance with German standards (VDE). Danger! Risk of burning! The battery has powerful short-circuit currents. Incorrect connection or isolation faults can lead to melting of the plug connections, sparking potential and severe burns! The unit has a warning signal that sounds when the battery voltage of PROTECT A. is exhausted or when the UPS is not working in its normal mode. Observe the following safety instructions to ensure permanent operational safety of and safe work with the UPS: Do not dismantle the UPS! (The UPS does not contain any parts which require regular maintenance. Bear in mind that the warranty will be invalidated if the unit is opened!) Do not install the unit in direct sunshine or in close proximity of heaters! The unit is designed to be installed inside in heated rooms. Never install the UPS in the vicinity of water or in an excessively damp environment! Condensation may occur if the UPS is brought from a cold environment into the room where it is to be installed. The UPS must be absolutely dry prior to startup. As a result, leave it to acclimatise for at least two hours. 6

Never connect the mains input to the UPS output! Ensure that no fluids or foreign bodies can penetrate the UPS! Do not block the side air vents of the unit! Keep children away from the unit and ensure that objects are never inserted through the vents! Do not connect household appliances such as hairdryers to the UPS! The mains connection should be near the unit and easily accessible to facilitate disconnecting the AC input or pulling out the plug! During operation, do not disconnect the mains connection cable from the UPS or from the socket outlet in the building (shockproof socket), otherwise the protective grounding of the UPS and all the loads connected to it will be cancelled. Danger! Electric shocks! Even after the mains voltage has been disconnected, the components within the UPS remain connected to the battery and can thus cause electric shocks. It is therefore imperative to disconnect the battery circuit before carrying out any maintenance or repair work! If it is necessary to replace the battery or carry out maintenance work, this must be done by or under the supervision of a person familiar with batteries and the necessary safety precautions! Only authorised persons are allowed in the vicinity of the batteries! When replacing the battery/batteries, the following must be observed: Only ever use identical maintenance-free sealed lead batteries with the same data as the original battery/batteries. Danger! Explosive! Never throw batteries into open fire. Never open or damage batteries. Electrolyte may leak out and damage skin and eyes. It may be toxic! 7

Batteries can cause electric shocks and high short-circuit currents. Therefore, take the following safety precautions when working with batteries: Take off watches, rings and other metallic objects! Always use tools with insulated handles! For personal safety reasons, never switch on the main switch when the mains connector of PROTECT A. is disconnected! 8

3 System Description i PROTECT A. is an uninterruptible power supply (UPS) for essential loads such as personal computers (PCs) or ISDN telecommunication equipment and similar devices. It consists of: Mains filter in the mains input incl. mains energy backfeed protection A.V.R. control system (automatic voltage regulation with mains operation) Battery charger for charging the battery Battery as energy storage medium for bridging mains failures (for supplying the inverter) Inverter for the supply of connected loads with AC voltage during mains failures Static bypass switch for switching over the loads to the inverter in the case of a mains failure UPS Block diagram PROTECT A. The UPS is connected to a shockproof socket between the public utility's mains and the loads to be protected. Under normal operating conditions, i.e. if PROTECT A. is supplied with mains voltage, the battery charger will ensure that the battery is always completely charged. During this operating status, the loads connected to PROTECT A. are supplied with voltage via double mains filters which provide 9

effective protection against mains voltage peaks and highfrequency faults. In case of sustained mains undervoltage or overvoltage within defined ranges, the automatic voltage regulator (A.V.R.) further stabilises the load voltage. As a result, voltage fluctuations in the public utility's mains are reduced to a level which is acceptable for the loads. This is performed without recourse to the internal energy storage, something which in turn has a positive effect on battery availability. The static bypass switch is activated in the event of a mains failure. The inverter then takes over the voltage supply of the connected loads, in order to prevent the risk of data loss or damage to the loads. PROTECT A. supplies voltage until the battery is discharged, allowing you to shut down your IT system properly and switch it off. The standby time mainly depends on the connected loads. If the mains power supply is back to normal values, the UPS will switch back the loads to mains supply. The battery charger will then recharge the battery. For safety reasons (as required by German standards, VDE), the mains input in the unit will be disconnected by a two-pole switch in the event of a mains failure. Energy backfeed to the mains and voltage supply to the pins of the mains connector are thus reliably avoided. 10

4 Set-Up and Operation Installing the UPS is as easy as following the steps shown. 4.1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 4.2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit which is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. Also, place the UPS at least 20 cm away from the monitor to avoid interference. 11

4.3 Charging This unit is shipped from the factory with its internal battery fully charged, however, some power may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load (no electrical devices such as computers, monitors, etc.). 8 hours 4.4 Computer connection Connect one computer-related device to each of the power sockets found on the back of the UPS. 4.5 Data lines protection Plug the incoming internet line into the In socket at the back of the PROTECT A. UPS. Incoming phone, fax, modem line 12

Use one more internet line cable and plug one end of the internet line cable to the Out socket at the back of the PROTECT A. UPS. Plug the other end of the modem input socket as shown. 4.6 USB and serial cable connection To allow for unattended system shutdown for your operating system, connect the USB or the RS232 serial cable as shown below. For the USB serial cable just simply plug into the UPS and PC and it will be auto detected. RS232-connection USB port 4.7 Turn On/Off To turn on the PROTECT A., press the power switch lightly. To turn off the PROTECT A., press the power switch again. 4.8 Deep discharge protection The PROTECT A. is equipped with Green Power Function. For saving power and protecting the battery, this method of deep discharge protection is adopted in inverter mode. 4.9 Battery removal Disconnect all power sources before battery replacement. Follow Fig. 1 below to remove the screw located on the bottom of the front panel and then open the front cover. 13

Fig. 1 Fig. 2 Fig. 3 After removing the front cover, follow Fig. 2 above to remove partition by unscrewing it. Then follow Fig. 3 to remove the battery. 4.10 Shutdown- and UPS management software The "CompuWatch" software specially developed for these purposes by AEG continuously checks the mains supply and the UPS status. 14

In conjunction with the "intelligent" UPS, this ensures that the availability of IT components and data security are guaranteed. The "CompuWatch" shutdown software supports different operating systems: Windows 98SE/ME, Windows NT/2000/ XP, Linux SUSE, Linux RedHat, Novell NetWare, IBM AIX, HP-UX, SUN Solaris, Mac OS, and others. Refer to the manual on the CD for details about installing the software on the various operating systems. 5 UPS overview Connections, Operation / Display Elements: Front view 1 Red LED to signal "Warning/fault" 2 LED bar graph for UPS load and battery capacity. The bar graph show the load of the UPS system if the mains power is available (normal operation). In the battery operation, the LEDs indicate the capacity of the batteries: 0 ~ 25%: 1. LED 26% ~ 50%: 1. and 2. LED 51% ~ 75%: 1., 2. and 3. LED 76% ~ 100%: All 4 LEDs are lighting 3 Green LED lighting to signal "Mains Green LED flashing: Battery mode 4 Main switch of the UPS (mains switch) Rear view 1 Load connections (UPS outputs) 2 Mains connection (UPS input) 3 Data line interface for phone, fax, modem 4 RS232 communication interface (SUB-D 9-pin socket) 5 USB port 6 Input breaker 15

5.1 Specifications MODELL PROTECT A. 1000 PROTECT A. 1400 Type 1000 VA / 600 W 1400 VA / 840 W UPS-input UPS-output Battery Indicator Acoustic alarm Protection General data Communication Input voltage Input voltage range without battery mode Frequency (auto selection) Rated output voltage /AVR-technology Rated output voltage in battery mode Frequency in battery mode Transfer time at mains outage Output Waveform 220 Vac / 230 Vac / 240 Vac 170 280 Vac 50 / 60 Hz ± 5 Hz 220 Vac / 230 Vac / 240 Vac ±10% 50 / 60 Hz ± 1 Hz 2 6 ms (typical) Modified sinewave Type 12 V / 7 Ah x 2 12 V / 9 Ah x 2 Autonomy time (full Load) Recharge time (to 90% of rated capacity) AC mode Backup mode Fault Backup mode Low battery Overload Battery replacement Fault USP Size W x H x D (mm) 3 min 8 h Green LED lighting LED bar graph (LED 2 to 5) indicates the load capacity Green LED flashing LED bar graph (LED 2 to 5) indicates the battery capacity Red LED lighting Sounding every 10 seconds Sounding every second Sounding every 0.5 second Sounding every 2 seconds Continuously sounding Discharge, overcharge, and overload protection 140 x 180 x 370 Weight (kg) 14 kg 14,5 kg Operating temperature range Audible noise (1 m distance) Interfaces Shutdown-Software (on CD) 0-40 C Relative humidity: 0 90 % (non-condensing) < 45 db (A) USB and RS232 for status and measurement levels Included for all typical operating systems (e.g. Windows, Linux, Mac) 16

6 Trouble shooting SYMPTOM CAUSE REMEDY No LED display on the front panel Alarm buzzer beeps continuously when AC supply is normal When power failure, back-up time is short Mains normal but LED is flashing Communication lost between UPS and computer. Missing battery Battery fault Power switch not pressed UPS overload UPS overload Battery voltage is too low Battery fault due to high temperature operational environment, or improper treatment of battery Fuse is blown Power cable is loose Software not properly installed Charge battery up to 4 hours Replace with the same type of battery Turn on the switch again Verify that the load matches the UPS capability as specified in the specs Remove some non-critical load Charge battery 4 hours or more Replace with the same type of battery Replace with the same type of fuse Reconnect the power cable properly Check the settings of the software Cable not properly connected Check if the RS232-cable is properly connected to COM1 / COM2 of the computer and reconfirm the settings once again If any abnormal situations occur that are not listed above, please call the service centre immediately. 17

Guarantee certificate Type:.... Serial-no.:..... Date of purchase:...... Trading stamp / Signature Specifications are subject to change without notice. AEG Power Supply Systems GmbH Emil-Siepmann-Str. 32 59581 Warstein-Belecke Germany Operating Instructions UPS BAL 8000015757 EN AEG0206EN 18