LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Similar documents
LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Pressure transmitter for industrial applications Type MBS 4510

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO MIDAS Pressure transmitter

Pressure transducer DMU 01K Compact version

CTE8000 / CTU8000 Series

Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

SITRANS P measuring instruments for pressure

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Pressure transmitters for industrial applications Type MBS 4510

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

SATRON VDt Differential Pressure Transmitter

JUMO dtrans p20 DELTA

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Differential pressure switch Model DPS40

Mechatronic pressure measurement. Applications. Special features. Description

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Electronic flow switch With display, for liquid media Model FSD-3

SATRON VT Pressure Transmitter

Differential pressure gauge Model , copper alloy Model , stainless steel version

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Differential pressure transmitter PASCAL Ci4 Delta P

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

CTE7000 / CTU7000 Series Miniature pressure transmitters

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure Transmitter JUMO dtrans p30 Type

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Compact differential pressure switch Models DC, DCC

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Direct-acting 3/2 way plunger valve

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Pressure transmitter for elevated media temperatures

JUMO MIDAS S05 Pressure transmitter Type

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Submersible Pressure

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information

2/2- and 3/2-way solenoid valve for aggressive fluids

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Pressure transmitter for marine applications MBS 33M

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Absolute pressure gauge with diaphragm

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Magnetic-inductive flow meter for hazardous areas

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Compact pressure switch Model PCS

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Flow switches Series AD/VH

Compact temperature switch Model TCS

Differential pressure transmitter PASCAL Ci4 Delta P

Temperature sensor TE2

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Pressure transmitters for heavy duty applications Type MBS 3250

SATRON VTe pressure transmitter

Pressure transmitter for industrial applications Type MBS 4500

Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Pressure Transmitter JUMO dtrans p30 Type

Pressure Transmitters for Sanitary Applications Model SA-11

Pressure transmitter JUMO dtrans p02

ECT Applications. Features

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Surface thermocouple Model TC50

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Magnetic switch For bypass level indicators Model BGU

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Transcription:

LMK 87 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signal -wire: 4... 0 ma Special characteristics diameter mm diaphragm ceramics 99,9% AlO good long-term stability especially for waste water Optional versions IS-version Ex ia = intrinsically safe for gases and dust drinking water certificate according to DVGW and KTW mounting with stainless steel tube different kinds of cable different kinds of elastomer The stainless steel probe LMK 87 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. Compared to the level probe LMK 8 the outside-diameter is only mm, which allows an easy installation and backfitting in tubes or in cramped fitting conditions. An IS-version is also available. Preferred areas of use Water groundwater and level monitoring Sewage waste water treatment water recycling Fuel and oil tank battery biogas plants BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

LMK 87 Technical Accessories data Input pressure range Nominal pressure gauge [bar] 0, 0.6 0.5 0.4 0.6.6.5 4 6 0 Level [mh O].6.5 4 6 0 6 5 40 60 00 Overpressure [bar] 4 5 5 7 7 0 0 0 0 Burst pressure [bar] 4 6 8 8 9 9 8 5 5 0 0 Permissible vacuum [bar] -0. -0. -0.5 - Output signal / Supply Standard -wire: 4... 0 ma / V S =... 6 V DC Option IS-version -wire: 4... 0 ma / V S = 4... 8 V DC Performance Accuracy standard: ± 0.5 % FSO option: ± 0.5 % FSO Permissible load R max = [(V S V S min ) / 0.0 A] Ω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year Turn-on time 450 msec Mean response time 70 msec Measuring rate 80 Hz accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band [% FSO].0% FSO in compensated range -0... 80 C Permissible temperatures Permissible temperatures medium:-5... 85 C storage: -5 70 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection Cable outlet shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges absolute, the air tube is closed) Materials (media wetted) Housing stainless steel.4404 (6 L) Cable PUR (-5 70 C) black FEP (-5 70 C) black TPE-U (-5 5 C) blue (without/with drinking water certificate) Seals (O-rings) standard: FKM option: EPDM (without/with drinking water certificate) FFKM (min. permissible temperature from -5 C) Diaphragm ceramics Al O 99,9% Protection cap POM-C do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Explosion protection Approval DX4B-LMK 87 IBExU 5 ATEX 066 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T5 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i = 49. nf; L i = 0 µh; the supply connections have an inner capacity of max. 00 nf opposite the enclosure Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment zone and higher: -5... 65 C Connecting cables cable capacity: signal line/shield as well as signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield as well as signal line/signal line: µh/m Miscellaneous Drinking water certificate 4 according to DVGW W 70 and UBA KTW (with order the indication "with drinking water certificate" is necessary) Current consumption max. ma Weight approx. 80 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 04/0/EU ATEX Directive 04/4/EU 4 only possible with EPDM seal in combination with TPE-U cable; not possible with IS-protection (explosion protection) Pin configuration Electrical connection cable colours (IEC 60757) Supply + Supply wh (white) bn (brown) Shield gnye (green-yellow) pressure and level

LMK 87 Wiring diagrams -wire-system (current) p Supply + A VS I Supply Dimensions (in mm/in) standard with protection cap without protection cap with thread R/ for mounting with stainless steel tube option: screw-in version G/4 G/ open www.bdsensors.com

LMK 87 Technical Accessories data Mounting flange with cable gland Suitable for all probes Flange material stainless steel.4404 (6 L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4.8 kg Ordering type Ordering code DN5 / PN40 with cable gland brass, nickel plated ZMF540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Suitable for all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Display program ZMF5040 ZMF806 Ordering code Z0058 Z0057 CIT 00 Process display with LED display CIT 50 Process display with LED display and contacts CIT 00 Process display with LED display, contacts and analogue output CIT 50 Process display with LED display, bargraph, contacts and analogue output CIT 400 Process display with LED display, contacts, analogue output and Ex-approval CIT 600 Multichannel process display with graphics-capable LC display CIT 650 Multichannel process display with graphics-capable LC display and datalogger CIT 700 / CIT 750 Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440 Field display with 4-digit LC display For further information please contact our sales department or visit our homepage: http://www.bdsensors.com cable gland M6x.5 with seal insert (for cable- 4... mm) 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. LMK87_E_048 pressure Tel: and +49 level (0) 9 5 / 98-0 www.bdsensors.com Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

Ordering code LMK 87 LMK 87 - - - - - - - - - - Pressure 6 0 6 consult 6 drinking water certification only possible with EPDM seal (code T) in combination with TPE-U cable (code F); not possible with IS-protection (explosion protection) min. permissible temperature from -5 C cable with integrated air tube for atmospheric pressure reference 4 stainless steel pipe is not part of the supply gauge in bar absolute in bar gauge in mh O Input [mh O] [bar] 0. 0 0 0.6 0.6 6 0 0.5 0.5 5 0 0 4.0 0.40 4 0 0 0 6.0 0.60 6 0 0 0 0.0 0 0 6.6 6 0 5.5 5 0 40 4.0 4 0 0 60 6.0 6 0 0 00 0 0 0 9 9 9 Housing stainless steel.4404 (6L) Design probe screw-in version G/" open screw-in version G/4" flush A B Diaphragm ceramics Al O 99.9% C Output 4 0 ma / -wire intrinsic safety 4 0 ma / -wire E Seals FKM EPDM DVGW/KTW: EPDM T FFKM 7 consult Electrical connection PUR-cable FEP-cable TPE-U-cable 4 DVGW / KTW: TPE-U-cable, F Accuracy standard 0.5 % FSO option 0.5 % FSO Cable length in m 9 9 9 Special version standard prepared for mounting with st. steel pipe 4 0 0 0 5 0 9 9.04.08 08 BD SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.