LMK 87 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signal -wire: 4... 0 ma Special characteristics diameter mm diaphragm ceramics 99,9% AlO good long-term stability especially for waste water Optional versions IS-version Ex ia = intrinsically safe for gases and dust drinking water certificate according to DVGW and KTW mounting with stainless steel tube different kinds of cable different kinds of elastomer The stainless steel probe LMK 87 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. Compared to the level probe LMK 8 the outside-diameter is only mm, which allows an easy installation and backfitting in tubes or in cramped fitting conditions. An IS-version is also available. Preferred areas of use Water groundwater and level monitoring Sewage waste water treatment water recycling Fuel and oil tank battery biogas plants BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de
LMK 87 Technical Accessories data Input pressure range Nominal pressure gauge [bar] 0, 0.6 0.5 0.4 0.6.6.5 4 6 0 Level [mh O].6.5 4 6 0 6 5 40 60 00 Overpressure [bar] 4 5 5 7 7 0 0 0 0 Burst pressure [bar] 4 6 8 8 9 9 8 5 5 0 0 Permissible vacuum [bar] -0. -0. -0.5 - Output signal / Supply Standard -wire: 4... 0 ma / V S =... 6 V DC Option IS-version -wire: 4... 0 ma / V S = 4... 8 V DC Performance Accuracy standard: ± 0.5 % FSO option: ± 0.5 % FSO Permissible load R max = [(V S V S min ) / 0.0 A] Ω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year Turn-on time 450 msec Mean response time 70 msec Measuring rate 80 Hz accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band [% FSO].0% FSO in compensated range -0... 80 C Permissible temperatures Permissible temperatures medium:-5... 85 C storage: -5 70 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection Cable outlet shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges absolute, the air tube is closed) Materials (media wetted) Housing stainless steel.4404 (6 L) Cable PUR (-5 70 C) black FEP (-5 70 C) black TPE-U (-5 5 C) blue (without/with drinking water certificate) Seals (O-rings) standard: FKM option: EPDM (without/with drinking water certificate) FFKM (min. permissible temperature from -5 C) Diaphragm ceramics Al O 99,9% Protection cap POM-C do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Explosion protection Approval DX4B-LMK 87 IBExU 5 ATEX 066 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T5 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i = 49. nf; L i = 0 µh; the supply connections have an inner capacity of max. 00 nf opposite the enclosure Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment zone and higher: -5... 65 C Connecting cables cable capacity: signal line/shield as well as signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield as well as signal line/signal line: µh/m Miscellaneous Drinking water certificate 4 according to DVGW W 70 and UBA KTW (with order the indication "with drinking water certificate" is necessary) Current consumption max. ma Weight approx. 80 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 04/0/EU ATEX Directive 04/4/EU 4 only possible with EPDM seal in combination with TPE-U cable; not possible with IS-protection (explosion protection) Pin configuration Electrical connection cable colours (IEC 60757) Supply + Supply wh (white) bn (brown) Shield gnye (green-yellow) pressure and level
LMK 87 Wiring diagrams -wire-system (current) p Supply + A VS I Supply Dimensions (in mm/in) standard with protection cap without protection cap with thread R/ for mounting with stainless steel tube option: screw-in version G/4 G/ open www.bdsensors.com
LMK 87 Technical Accessories data Mounting flange with cable gland Suitable for all probes Flange material stainless steel.4404 (6 L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4.8 kg Ordering type Ordering code DN5 / PN40 with cable gland brass, nickel plated ZMF540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Suitable for all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Display program ZMF5040 ZMF806 Ordering code Z0058 Z0057 CIT 00 Process display with LED display CIT 50 Process display with LED display and contacts CIT 00 Process display with LED display, contacts and analogue output CIT 50 Process display with LED display, bargraph, contacts and analogue output CIT 400 Process display with LED display, contacts, analogue output and Ex-approval CIT 600 Multichannel process display with graphics-capable LC display CIT 650 Multichannel process display with graphics-capable LC display and datalogger CIT 700 / CIT 750 Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440 Field display with 4-digit LC display For further information please contact our sales department or visit our homepage: http://www.bdsensors.com cable gland M6x.5 with seal insert (for cable- 4... mm) 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. LMK87_E_048 pressure Tel: and +49 level (0) 9 5 / 98-0 www.bdsensors.com Fax: +49 (0) 9 5 / 98 - info@bdsensors.de
Ordering code LMK 87 LMK 87 - - - - - - - - - - Pressure 6 0 6 consult 6 drinking water certification only possible with EPDM seal (code T) in combination with TPE-U cable (code F); not possible with IS-protection (explosion protection) min. permissible temperature from -5 C cable with integrated air tube for atmospheric pressure reference 4 stainless steel pipe is not part of the supply gauge in bar absolute in bar gauge in mh O Input [mh O] [bar] 0. 0 0 0.6 0.6 6 0 0.5 0.5 5 0 0 4.0 0.40 4 0 0 0 6.0 0.60 6 0 0 0 0.0 0 0 6.6 6 0 5.5 5 0 40 4.0 4 0 0 60 6.0 6 0 0 00 0 0 0 9 9 9 Housing stainless steel.4404 (6L) Design probe screw-in version G/" open screw-in version G/4" flush A B Diaphragm ceramics Al O 99.9% C Output 4 0 ma / -wire intrinsic safety 4 0 ma / -wire E Seals FKM EPDM DVGW/KTW: EPDM T FFKM 7 consult Electrical connection PUR-cable FEP-cable TPE-U-cable 4 DVGW / KTW: TPE-U-cable, F Accuracy standard 0.5 % FSO option 0.5 % FSO Cable length in m 9 9 9 Special version standard prepared for mounting with st. steel pipe 4 0 0 0 5 0 9 9.04.08 08 BD SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.