CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Similar documents
Industrial Contactors CTX 3 3P 185A - 800A

AF40... AF96 3-pole contactors Technical data

up to 63 A (1 module per pole)

DX³ RCCBs - ID 4P up to 100 A

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Essential equipment for all your requirements

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

RX 3 M.C.B A up to 63 A

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

RX 3 M.C.B A up to 63 A

TX³ RCCBs 2P up to 100 A

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Cat N 3. OVERALL DIMENSIONS

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on left side

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

K50H004UP cam changeover switch - 4-pole A - screw mounting

DX³ 4-pole RCBO 6000 A/10 ka

Modular contactors and relays

K30H001YP cam star-delta switch - 3-pole A - screw mounting

(1,5 modules per pole)

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

For Info: Phone: Fax:

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Industrial contactors CTX-1

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

DX³ RCBO 6000A Phase + Neutral, neutral on left

Btdin RCBO 6000A up to 63A (2P)

Square D General Purpose Relays

R.C.B.O. SP / 1 module

B Mini Contactor V Hz

AE 9... AE 40 Contactors NE... Contactor Relays

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Meta Solution. Contactors and Overload relays

Manual Motor Starters. Meta-MEC

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

DRX 125 Circuit breaker (not adjustable)

Vistop TM isolating switches 63 to 160A

ASL09..S 3-pole Contactors - Spring Terminals

PRODUCT SPECIFICATION. Foot Switches. Series.

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

Standard Interlock Safety Switches

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

COMPLETE SOLUTIONS FOR POWER PROTECTION

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

TAE pole Contactors

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Meta Solution. Contactors and Overload relays

Auxiliary contact blocks - with spring terminals Accessories

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

XACA871 pendant control station XAC-A - 8 pushbuttons

Solenoid Locking Safety Switches

3 - Protection components Motor circuit-breakers

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Installation Contactors RIC, RAC

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Motor Protection Circuit Breakers

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

BC Mini Contactor VDC

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Modular contactor for installation into distribution boards

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Quick selection table

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

Cylindrical fuse-link

Short form catalogue. Motor protection & control

C -5 to +55 (0.8 to 1.1Uc) Permissible o

EW series Industrial contactors

Limit Switches - Limit Type Plastic Body IP65

Mini contactors B6, BC6 with 3 pole

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Limit Switches - Limit Type Plastic Body IP65

Transcription:

87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection... 1 5. General characteristics... 2 6. Conformities and approvals... 4 7. Auxiliaries and accessories... 4 1. DESCRIPTION - USE. Switch of light loads for control logic applications. Symbol: 3. OVERALL DIMENSIONS. CTX 3 Control relays. - Type AC and type DC: 2. RANGE Number of contacts:. 4 NO.. 3 NO + 1 NC.. 2 NO + 2 NC. Rated Voltage Ue / Frequency:. 600 [V], 50 / 60 [Hz]. Control voltage Uc:. 24 [V~], 24 [V=], 48 [V~], 48 [V=], 110 [V~], 230 [V~], 400 [V~]. 4. INSTALLATION - CONNECTION Fixing:. Clip-on mounting on 35 [mm] rail DIN or screw fixing. Operating position:. ± 30 [ ] possible, in relation to normal vertical mounting plane.. Keep the distance more than 10 [mm] with front panel. Supply:. Either from the top or the bottom. Size of wire connecting torque: Screw Wire Torque M3.5 1.25 to 2 [mm²] 0.8 [Nm] 1 / 5

5. GENERAL CHARACTERISTICS Connection:. Terminals protected against direct contact (IP20).. Terminals with release and captive screws.. Screw head : slotted and pozidriv n 2. Tools required:. Pozidriv N 2 screwdriver recommended.. Flat screwdriver Ø5 to Ø6 [mm] Maximum. Front side:. By dark grey laser or pad printing: - Brand: Legrand - Range: CTX mini - Coil terminals CTX 3 Control relays: (Example of marking) 5. GENERAL CHARACTERISTICS (continued) Rated impulse voltage and rated insulation voltage: Type of products Rated impulse voltage (Uimp) Rated isulation voltage (Ui) CTX 3 Control relays 6 [kv] 690 [V] Ambient operating temperature: (standard +20 C). Min. = -5 C. Max. = +40 C. Ambient storage temperature:. Min. = -30 C. Max. = +65 C. Max. temperature inside a panel:. +55 C. Weight: Type of products AC Control DC Control CTX 3 Control relays 0.17 [kg] 0.23 [kg] Degree of protection:. IP20. Flame resistance:. Conforming to UL = V0.. Conforming to IEC 695-2-1 = 960 [ C]. Maximum operating altitude:. 2000 [m]. Relative humidity:. 45 ~ 85% RH. Left side:. By identification label (referring to IEC standard) Shock resistance:. 5 [g]. Vibration resistance:(10-55 [Hz]). 2 [g]. 2 / 5

5. GENERAL CHARACTERISTICS (continued) Coil characteristic: Coil type AC coil - (50 / 60 [Hz]) DC Power consumption inrush - [W] 2 3 Power consumption holding - [W] 2 3 Control voltage (Uc) - [V] 24, 48, 110, 230, 440 24, 48 Operation voltage (Us) - [%] Operation time - [ms] Rating: In accordance with IEC 60947-4 and UL 508 certifications. For contactors CTX 3 Control relays.. Contact rating: AC duty DC duty Pick-up 80 75 Release 30 12 Coil ON Contact ON 20 50 Coil OFF Contact OFF 45 45 Rated currents Making / Breaking currents Inductive load - [A] Resistive load - [A] Inductive load - [A] Resistive load - [A] 120 [V] 6 10 66 66 240 [V] 3 8 33 33 480 [V] 1.5 5 16.5 16.5 600 [V] 2 5 13.2 13.2 125 [V] 1.1 5 3.7-250 [V] 0.55 3 1.8-440 [V] 0.31 2.5 1.4-600 [V] 0.2 1 0.7 - Continuous current, Ith - [A] 10. Performance: Operating cycles (operations / hour) 1 800 Endurance (in millions of operations) Mechanical lifetime 20 Electrical lifetime AC15 duty AC12 duty 220 [V] 0.5 440 [V] 0.5 220 [V] 0.25 440 [V] 0.25 DC13, 12 duty 24~220 [V] 0.5 3 / 5

6. CONFORMITIES AND APPROVALS Compliance to standards:. Reference standards: IEC/EN 60 947-4 and UL 508.. Certifications: CE, UL. 7. AUXILIARIES AND ACCESSORIES Auxiliaries:. 6 Auxiliary contacts maximum. (CTX 3 Control relays fit the same auxiliaries as CTX 3 mini contactors). Installation principle: 7. AUXILIARIES AND ACCESSORIES (continued) Auxiliaries: (continued) Contacts sensibility:. DC 24 [V] - 10 [ma]. Rating: In accordance with IEC 60947-4 and UL 508 certifications Current and Power Auxiliary contacts block AC 15 DC 13 120 [V] 6 [A] 240 [V] 3 [A] 380 [V] 1.9 [A] 480 [V] 1.5 [A] 500 [V] 1.4 [A] 600 [V] 1.2 [A] 125 [V] 0.55 [A] 250 [V] 0.27 [A] 400 [V] 0.15 [A] 500 [V] 0.13 [A] 600 [V] 0.1 [A] CTX 3 control relays auxiliary contact side: weight = 0.02 [kg] - 1NO (cat n 4 171 58) - 1NC (cat n 4 171 59) Rated operational voltage:. Ue = 600 [V]. Rated insulation voltage:. Ui = 690 [V]. Rated impulse voltage:. Uimp = 6 [kv]. Mechanical and electrical endurance: Type of products Mechanical endurance (in millions of operations) Electrical endurance (in millions of operations) CTX 3 control relays auxiliary contact front: weight = 0.04 [kg] - 4NO (cat n 4 171 53) - 3NO + 1NC (cat n 4 171 54) - 2NO + 2NC (cat n 4 171 55) - 1NO + 3NC (cat n 4 171 56) - 4NC (cat n 4 171 57) Auxiliary contacts 10 0.25 Conventional free air thermal current:. Ith = 10 [A]. 4 / 5

7. AUXILIARIES AND ACCESSORIES (continued) CTX 3 control relays auxiliary contact front: (continued) CTX 3 control relays auxiliary contact front: weight = 0.03 [kg] - 1NO + 1NC (cat n 4 171 50) - 2NO (cat n 4 171 51) - 2NC (cat n 4 171 52) Accessories: Installation software:. XL PRO 3. 5 / 5