Max. particle size 50 µm Max. oil content of compressed air

Max. oil content of compressed air

Max. particle size 50 µm

Pressure regulators E/P pressure regulators Series EV07. Brochure

Pressure regulators E/P pressure regulators Series ED02. Brochure

Pressure regulators E/P pressure regulators Series EV04. Brochure

Pressure regulators E/P pressure regulators Series ED05. Brochure

Flow and check valves Logic valves Logic valves (AND/OR) Brochure

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Directional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure

Directional valves Mechanically operated Series AP - inch. Brochure

Directional valves Mechanically operated Series CD07. Brochure

5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return

Valve terminal systems Valve terminal systems Series TC15. Brochure

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Directional valves Mechanically operated Series AP. Brochure

Directional valves Pneumatically operated Series 740. Brochure

Max. particle size 5 µm. Pressure for determining piston forces Repetitive precision. Polyurethane

Valve terminal systems Valve terminal systems Series TC08. Brochure

Directional valves Electrically operated CL03 series-ev. Brochure

Short-stroke cylinder, Series SSI Ports: M5 - G 3/8 double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread

Number of fingers 2. Max. particle size 5 µm. Pressure for determining forces

Sensor technologies Pressure sensors Series PE5. Brochure

Flow and check valves Logic valves Pneumatic counters. Brochure

Standards ISO Max. particle size 50 µm. Pressure for determining piston forces. Materials: Polyurethane

Rotary actuators Rack-and-pinion gears series TRR. Brochure

Short-stroke cylinder, Series KHZ Ports: M5 - G 1/4 Single-acting, retracted without pressure Cushioning: elastic Piston rod: Internal thread

Max. particle size 5 µm. Pressure for determining piston forces. Materials:

Standards NFE Max. particle size 50 µm. Pressure for determining piston forces. Materials:

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

Standards NFE Max. particle size 50 µm. Pressure for determining piston forces. Materials:

Proportional Pressure Relief Valve Series RE*T

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Series BCP standard version double Stroke: mm

Proportional Throttle Valves Series TDL

Electromotoric actuators

Sentronic D 608 Series and 609 Series

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Rodless cylinders Rodless cylinders Series RTC. Brochure

Pilot-Operated Proportional DC Valve Series D*1FH

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Standards ISO Max. particle size 50 µm. Pressure for determining piston forces 6 bar. Materials:

Series PD directly operated solenoid valves

TopControl Continuous

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Intelligent Positioner

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Servo solenoid valves with on-board electronics (OBE)

Series 3730 Electropneumatic Positioner Type

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Series PD directly operated solenoid valves

Pressure Regulators MS-LR, Inch Series Overview

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings

Preparation of compressed air Supplementary products Pressure gauge. Brochure

PROPORTIONAL VALVES Sentronic D - G 1/8 to G 3/8 tapped body or G 1/8 - G 1/4 subbase mounted body with digital pressure control

Max. particle size 5 µm. Pressure for determining piston forces. Materials:

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Solenoid valves MHJ, fast-switching valves

Sentronic PLUS 614 Series

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Proportional directional control valves MPYE

Series P directly operated solenoid valves

Servotronic Digital 615 Series

Proportional pressure regulators VPPX

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional pressure relief valve, pilot operated

Actuator LD3. Product Data Sheet Feature

Proportional pressure relief valve, pilot operated

TZIM. Electropneumatic Analog Positioner 10/ EN

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

One-way flow control valves GR/GRA, in-line installation

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

40 l/min (11 GPM) p max

Chapter 2: Directional Control Valves

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Pilot-Operated Directional Control Valves Series D3 - D11

Proportional pressure regulators MPPES

Pressure Sensors. for liquid and gaseous media

APS-10 to 15 Series. PBT Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Transcription:

Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Version Poppet valve Control Analog Certificates CE declaration of conformity Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Medium Compressed air Max. particle size µm Max. oil content of compressed air mg/m³ 68 Qn l/min Mounting orientation α = - 9 ±β = - 9 Operating pressure See table below DC operating voltage V Voltage tolerance DC -% / +% Permissible ripple % Max. power consumption ma Protection class IP6 Weight. kg Materials: Housing Seal Die-cast aluminum; Steel Hydrogenated acrylonitrile butadiene rubber Nominal flow Qn with working pressure 7 bar, with secondary pressure 6 bar and Δp =. bar Technical Remarks The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least C under ambient and medium temperature and may not exceed C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS, see chapter Technical information. With oil-free, dry air, other installation positions are possible on request. The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions. Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Operating pressure max. Pressure setting range min./max. Nominal input value Actual output value Hysteresis Fig. Note Part No. - / - ma - ma <, bar Fig. - R686 - / - ma - ma <, bar Fig. - R96 - / - V - V <, bar Fig. - R96 / - ma - ma <, bar Fig. - R96 / - ma - ma <, bar Fig. - R96 / - V - - <, bar Fig. ) R96 / - V - V <, bar Fig. - R96 / - ma - ma <, bar Fig. - R96 / - ma - ma <, bar Fig. - R96 / - V - - <, bar Fig. ) R966 / - V - V <, bar Fig. - R967 8 / 6 - ma - ma <, bar Fig. - R69 8 / 6 - ma - ma <, bar Fig. - R69 8 / 6 - V - - <, bar Fig. ) R69 8 / 6 - V - V <, bar Fig. - R69 / - ma - ma <, bar Fig. - R7 / - ma - ma <, bar Fig. - R7 / - V - - <, bar Fig. ) R7 / - V - V <, bar Fig. - R7 8 / 6 - ma - ma <, bar Fig. - R77 8 / 6 - ma - ma <, bar Fig. - R77 8 / 6 - V - - <, bar Fig. ) R77 8 / 6 - V - V <, bar Fig. - R77 / - ma - ma <,9 bar Fig. - R78 / - ma - ma <,9 bar Fig. - R786 / - V - - <,9 bar Fig. ) R787 / - V - V <,9 bar Fig. - R788 ) Output V constant to supply a set point potentiometer. Minimum working pressure =. bar + max. required secondary pressure Additional pressure setting ranges available on request Flow diagram P a [psi] 9 6 8 7 6 6 87 8 6 8 9 6 [NI/min] IM976 Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Dimensions 78 6, ),6 ), ) 9 9,,, 8,9 66 Mx9 XPC SW ED 8, ) Operating pressure Working pressure Exhaust ) Flat gasket ) Accessories not supplied 9 Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Mounting orientation β = ±...9 β β α α = +...9 78 Functional diagram a) Nominal input value b) Actual output value The E/P pressure control valve modulates the pressure corresponding to an analog electrical nominal input value. ) Operating pressure Working pressure Exhaust 77 Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Fig., Characteristic and pin assignment for current control with actual output value Pa, max,7 x Pa ) + V DC /... ma M, A, x Pa, x Pa V /... ma - Pa, min 8 6 [ma] 8 6 [ma] ) Supply Voltage Actual value (pin ) and nominal value (pin are related to V (control voltage). Nominal input value current (ohmic load Ω). Actual output value (max. total resistance of downstream devices < Ω). The operating voltage must be protected by an external M. A fuse. Connect the plug via a shielded cable to ensure EMC. IM978 Fig., Characteristic and pin assignment for voltage control with actual output value Pa, max,7 x Pa ) + V DC - V DC + M, A, x Pa, x Pa V - V DC + - Pa, min 6 8 [V] IM98 ) Supply Voltage Actual value (pin ) and target value (pin are related to V. If the supply voltage is switched off, the voltage input value is high-ohmic. Input resistance under supply voltage: MΩ Voltage output (actual value): external working resistance kω The operating voltage must be protected by an external M. A fuse. Connect the plug via a shielded cable to ensure EMC. Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change

6 Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Fig., Characteristic and pin assignment for potentiometer control without actual output value - Pa, max,7 x Pa, x Pa, x Pa Pa, min % ) Supply Voltage Actual value (pin is related to V. If the supply voltage is switched off, the voltage input value is high-ohmic. Input resistance under supply voltage: MΩ The operating voltage must be protected by an external M. A fuse. Connect the plug via a shielded cable to ensure EMC. ) + V DC - V DC + V V DC + M, A IM98 Pneumatics catalog, online PDF, as of 7--, AVENTICS S.à r.l., subject to change