Airscrew 200+ Vmax Vaneaxial Fans

Similar documents
Airscrew 105 to 170 Vmax Vaneaxial Fans

Rotron MIL-80 Tubeaxial Fans

Rotron MAXIAX Large Vaneaxial Fans

Rotron NANOS Small Vaneaxial Fans

6400 RPM. All aluminum components finished with a chemical Weight: approximately 0.74 lbs.

Rotron MIL901 Tubeaxial Fans

Rotron MAXIAX 5.75 Large Vaneaxial Fans

Rotron HF/ HFV/ HFG Propeller Fans

Fan - Powered Terminal Unit Series Flow

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

IN-LINE CENTRIFUGAL DUCT FANS VT Series

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

Sabre Plate Mounted Sickle Fans (VSP)

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Energy-saving motors (ESM)

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Multi-Port Centrifugal Fans for Round Duct

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Powerful centrifugal fans for universal use: The product ranges TEM and REM

SILENT MV Ultra Quiet In-line Fans

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Axial fans. What s more, non-stock models are normally available within two weeks.

Fan Efficiency Grades and System Effect and Their Effects on HVAC Systems

FIXED PITCH PROPELLER FANS

Smart. Eco-friendly. Cost effective. The way. Technology. should be PRODUCT CATALOGUE

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

CGT Series Adjustable Pitch Fans

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

NK /310A2F1AE-SBAQE

CGT Series Adjustable Pitch Fans

NB80-160/161 A-F2-A-BQQE

Square Mixed Flow Fans (MFQ)

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

NB /263 AS-F2-A-BAQE

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CONSTRUCTION FEATURES AND OPTIONS

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Short casing. Long casing (L version) Commercial premises

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

NK40-160/172A1F2AE-SBAQE

NB /193 A-F2-A-BAQE

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

NB /438 A-F1-A-GQQE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Variable Air Volume Dampers

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Energy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch

Variable Air Volume (VAV) Pressure Independent Control

RADIAL ALUMINUM LOW PRESSURE

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

QUBE SQU-HT(S) Product Brochure

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Air Moving Solutions. axifan adjustable blade vaneaxial fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Unobox units with backward curved centrifugal impellers

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

TUBULAR CENTRIFUGAL INLINE FANS

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

NBE50-250/205 A-F2-A-BAQE

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Custom Shipyard and Military Facility Products

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

EVALUATION REPORT 347

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

Defining Innovation. backward curved FANs

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Twin City Fan & Blower

VANEAXIAL & TUBEAXIAL FANS

TD-ECOWATT AND DECOR-ECOWATT Series

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

NEW Acoustic In-Line Fans (ACQ)

Plate mounted axial flow fans HXBR / HXTR Series

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

BOX BLB Centrifugal Box Fan

Transcription:

Airscrew + Vmax Vaneaxial Fans General Vaneaxial Information Vmax Vaneaxial Fans comprise a combination of rotating impeller and stationary guide vanes, housed within an axial duct known as the fan case. The function of the guide vanes is to increase the pressure capability of the fan. Higher aerodynamic efficiencies are achieved with true airfoil blade designs. These fans typically operate up to the aerodynamic stall point. The axial configuration allows easy installation into ducted systems, with cooling air passing over the integral motor, allowing compact motor design with high power demand in small packages. The Vaneaxial designs are suitable for operation in severe environments, including sand scavenge applications. Vmax Fans are available in AC or DC supply configuration and can be supplied with thermal protection, speed sensing and customized interfaces. Vmax Fan Vmax Series: imum Performance Curve 6. 4.. Static Pressure (inches water gauge). 8. 6. RPM 4... Airflow (cfm) *Individual Performance Curve Characteristics Available Upon Request General Physical Envelope: Ø8.7 x 9.4 (Ømm x 4mm) Weight: 7.lbs. (7.8kg) Airflows up to 86 CFM (l/s) Static Pressures: up to 4. IWG (.kpa) Suitable for Sand Scavenge Applications Thermal Protection Locked Rotor Protection Options/Accessories Speed Sensors Thermal Sensors Materials and Finishes Aluminum alloy anodized dyed black impeller, guidevanes and case Stainless steel S8D shaft High precision, sealed ABEC 7, maintenance free bearings Stator wound to class H insulation Stainless Steel Blades for Sand Scavenge Applications Chrome Impeller Track for erosion protection Thermal Protection Finger Guards 6-9

Unit Description Key The unit description key is for reference only and should not be confused with a part number. While most units are custom configurations, not all variations of the key shown below are possible. Please contact the Application Engineering department for more information regarding possible custom configurations. A A REPRESENTS A DESIGN STAGE OF THE FAN (EX: THIS NUMBER WILL CHANGE WITH MODIFICATIONS IN THE UNIT, AFFECTING INTERCHANGEABILITY BUT NOT USUALLY PERFORMANCE) REPRESENTS A PARTICULAR ITEM OR DESIGN WHEN ASSOCIATED WITH THE PRECEDING NUMBER ELECTRICAL SUPPLY OR DRIVE: = 8 VOLTS DC 6 = (NOT YET ALLOCATED) = VOLTS DC 7 = BELT DRIVE = HYDRAULIC DRIVE 8 = DIRECT DRIVE WITH INTEGRAL BEARINGS 4 = /6 Hz AC 9 = (NOT YET ALLOCATED) = 4 Hz AC = TURBINE DRIVE AIRSCREW AERODYNAMIC DESIGN REFERENCE FAN CONFIGURATION A = AXIAL (EX: AIR DISCHARGE AXIALLY) C = CENTRIFUGAL (EX: AIR DISCHARGE CENTRIFUGAL) P = PARTITION-MOUNTED (EX: WITH FREE DISCHARGE, NOT ARRANGED FOR DUCTED OUTLET OR INLET) IMPELLER TYPE: A = AXIAL C = CENTRIFUGAL M = MIXED FLOW IMPELLER DIAMETER IN MILLIMETRES (IN THE CASE OF MIXED FLOW USE THE MEAN OUTLET DIAMETER) EXAMPLE:, AA, WHERE: = MM IMPELLER DIAMETER, A = AXIAL IMPELLER, A = AIR DISCHARGE AXIALLY, = AERODYNAMIC DESIGN REFERENCE, = 4 Hz AC LINE ELECTRICAL SUPPLY, = FIRST INSTALLATION DESIGN STAGE Ordering Information When ordering, please specify the specific Airscrew part number listed on the following model table. Further ordering information, based on the configuration and motor series, may be obtained by contacting customer service. Please refer to the Unit Description Key explanation above. 6-9

Standard Product Offering of AC Line Powered Models Pressure (IWG) Line Amps (A) Part # Prod Description FLOW (CFM) Nom RPM Nom Watts Weight (lbs) Phase Hz Volts Airflow Source Data 4 77-88.4. 48. 8.8 8 7.6 4 AS-4 478 -AA-4 8..4 4 49. N/A 6.8 6 48 AS7-4 48 -AA-4 88.49. 4 8.. N/A 6.8 6 AS7-479 7-AA-4 6.84.6 4..4 N/A. 4 AS7-49 8-AA-4 88.7.9 9 4..77 N/A 7.4 4 AS7-44 -AA-4 7.9.77 78.. N/A 4.8 6 AS7-4 44 -AA-4 7.4.98 9 4..7 N/A 4. 4 AS7-4 -AA-4 644..48 47 99.. N/A 6.4 4 AS7-6 46 -AA- 6.87.7 8.. N/A N/A 4 AS8- Amb (C) Standard Product Offering of DC Line Powered Models FLOW Pressure Nom Nom Line Amps Amb Weight Airflow Source Part # Prod Description (CFM) (IWG) RPM Watts (A) (C) (lbs) Volts Data 84 -AA9-88.4. 6 887. 4 44. 7. AS-4 Vmax Fan * *Part Number Specific Drawings Available Upon Request 6-94

P/N 4 77 - AS-4 AIR FLOW - liters/second at. Kg/m^ DENSITY 7.4 4.9 77.4 8.7 8.7 4.86 8. 6 8.7. 7..7 468. 8 74.67 87. 9.67 P/N 478 -AA-4 AS7-4 AIR FLOW - liters/second at. Kg/m^ DENSITY 68.7 7.4.7 74.9 4.86 4.4 48.4 6.6..8.4 4 7 44 6 88 6 9 84 76 768 96 6 4 4 AIR FLOW - CFM at.7 lbs/ft³ DENSITY 4 AIR FLOW - CFM at.7 lbs/ft³ DENSITY P/N 48 -AA-4 AS7- AIR FLOW - liters/second at. Kg/m^ DENSITY 68.7 7.4.7 74.9 4.86 4.4 48.76 68..84.8.9.46 6.67 4 4..67. P/N 479 7-AA-4 AS7- CONSULT FACTORY FOR DATA 9 84 76 768 96 6 4 AIR FLOW - CFM at.7 lbs/ft³ DENSITY P/N 49 8-AA-4 AS7- AIR FLOW - liters/second at. Kg/m^ DENSITY.7.4 77.4.86 8.7 4.9 8.4 6 9.6..8.4 4 P/N 44 -AA-4 AS7-4 AIR FLOW - liters/second at. Kg/m^ DENSITY 68.7 7.4.7 74.9 4.86 4.4 48. 8 6 4.8.6.4. 7 44 6 88 6 4 9 84 76 768 96 7 AIR FLOW - CFM at.7 lbs/ft³ DENSITY 7 AIR FLOW - CFM at.7 lbs/ft³ DENSITY 6-9

P/N 44 -AA-4 AS7- AIR FLOW - liters/second at. Kg/m^ DENSITY 8.7 7.4 8.7 4.9 64.86 77.4 9 7. 9.. 6. 7.. P/N 4 -AA-4 AS7-6 AIR FLOW - liters/second at. Kg/m^ DENSITY.4.86 4.9.7 7.4 8.7 6.6..4.... 7.. 6 7 8 44 8 4 44 88 4 76 7 7 AIR FLOW - CFM at.7 lbs/ft³ DENSITY 9 8 7 AIR FLOW - CFM at.7 lbs/ft³ DENSITY P/N 46 -AA- AS8- AIR FLOW - liters/second at. Kg/m^ DENSITY 48.4 696.9 44.4 9.7 74.7 88.86 47 6 4 4 9 4 7 P/N 84 -AA9- AS-4 AIR FLOW - liters/second at. Kg/m^ DENSITY 7.4 4.86 4.9 68.7 87.4 8.7 6 4 4 7 97 9 9 9 487 48 96 44 9 4 9 6 AIR FLOW - CFM at.7 lbs/ft³ DENSITY 7 4 CONSULT FACTORY FOR DATA AIR FLOW - CFM at.7 lbs/ft^ DENSITY 6-96