electrical submersible pumps www.ipspumps.be Set-back vortex impeller General characteristics Set-back vortex impeller motor power,, kw poles / / 6 delivery port GAS / vertical DN65 DN50 horizontal free max 50 mm max flow rate 6. l/s max head. m Electromechanical assembly Electromechanical assembly in GJL-50 cast iron, for submerged operation. Seal set comprising (two) opposing silicon carbide mechanical seals in inspectable oil sump. Ecological dry motor. Series available in AEX explosion-proof version. Applications Used with unstrained soiled biological wastewaters and sewage and for civil lifting applications. It is thus ideal for wastewater treatment plants, sewer systems, livestock farms, industry and agriculture. his series is prefitted for installation of the ZENI cooling system for dry or semisubmerged installation. onstruction materials ase Impeller Nuts and bolts Standard gasket Shaft ooling jacket Paint type Set of standard mechanical seals ast iron EN-GJL 50 ast iron EN-GJL-50 Stainless steel - lass A-70 Rubber - NBR Stainless steel - AISI 0 Stainless steel - AISI 0 Ecological bicomponent epoxy (medium thickness 50 µm) wo silicon carbide mechanical seals (Si) Operating limits Maximum operating temperature PH of treated fluid Viscosity of treated fluid Maximum immersion depth Density of treated fluid Maximum acoustic pressure max starts per hour 0 6 mm/s 0 m Kg/dm 70 db 0 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps 6 5 ooling system Dry installation available using the cooling jacket (see details to page 7) able Gland able gland system to guarantee perfect water-tightness. he GAS thread ring-nut can be removed to fix a rigid or flexible duct to the cable gland to protect the power supply cable Mechanical seals wo silicon carbide (Si) mechanical seals in oil sump Oil sump Large oil sump to guarantee longer mechanical seal lifetime. A threaded flange can be easily removed to replace the mechanical seals Drive shaft Impeller connected to the drive shaft by means of tapered coupling 5 Wide free allowing the expulsion of solids and preventing fouling of the impeller 6 EX Models available on request with AEX certification, suitable for installation in the presence of potentially explosive gases, powders and liquids 096 II GD Ex d kc IIB 5 td A 00 IP68 X 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Models with vertical GAS / threaded delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50//G65V ADM/50 0.8.8.5 900 Dir G / A - B 65 mm V Phases P (kw) P (kw) A Rpm Start 50//G65V AD/50 00.5.8. 900 Dir G / A - B 65 mm 00//G65V AD/50 00.9. 5. 900 Dir G / A - B 65 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Models with horizontal DN65 PN0-6 flanged delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50//65 ADM/50 0.8.8.5 900 Dir DN65 PN0-6 A - B 65 mm V Phases P (kw) P (kw) A Rpm Start 50//65 AD/50 00.5.8. 900 Dir DN65 PN0-6 A - B 65 mm 00//65 AD/50 00.9. 5. 900 Dir DN65 PN0-6 A - B 65 mm 00//65 AF/50 00.0 6.7 900 Dir DN65 PN0-6 A - B 65 mm 550//65 AF/50 00 5.0. 8.7 900 Dir DN65 PN0-6 A - B 65 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Models with horizontal DN80 PN0-6 flanged delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50//80 ADM/50 0.8.8.5 900 Dir DN80 PN0-6 A - B 80 mm V Phases P (kw) P (kw) A Rpm Start 50//80 AD/50 00.5.8. 900 Dir DN80 PN0-6 A - B 80 mm 00//80 AD/50 00.9. 5. 900 Dir DN80 PN0-6 A - B 80 mm 00//80 AF/50 00.0 6.7 900 Dir DN80 PN0-6 A - B 80 mm 550//80 AF/50 00 5.0. 8.7 900 Dir DN80 PN0-6 A - B 80 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Models with horizontal DN65 PN0-6 flanged delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 00//65 AD/50 00.0.5. 50 Dir DN65 PN0-6 A - B 65 mm 00//65 AF/50 00.9. 5.8 50 Dir DN65 PN0-6 A - B 65 mm 00//65 AF/50 00. 6.7 50 Dir DN65 PN0-6 A - B 65 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Models with horizontal DN80 PN0-6 flanged delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 00//80 AD/50 00.0.5. 50 Dir DN80 PN0-6 A - B 80 mm 00//80 AF/50 00.9. 5.8 50 Dir DN80 PN0-6 A - B 80 mm 00//80 AF/50 00.7 7. 50 Dir DN80 PN0-6 A - B 80 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Models with horizontal DN00 PN0-6 flanged delivery port - poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 00//00 AD/50 00.0.5. 50 Dir DN00 PN0-6 A - B 00 mm 00//00 AF/50 00.9. 5.8 50 Dir DN00 PN0-6 A - B 00 mm 00//00 AF/50 00.7 7. 50 Dir DN00 PN0-6 A - B 00 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Models with horizontal DN65 PN0-6 flanged delivery port - 6 poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50/6/65 AD/50 00.6..7 960 Dir DN65 PN0-6 A - B 65 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Models with horizontal DN80 PN0-6 flanged delivery port - 6 poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50/6/80 AD/50 00.6..7 960 Dir DN80 PN0-6 A - B 80 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Models with horizontal DN00 PN0-6 flanged delivery port - 6 poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50/6/00 AD/50 00.6..7 960 Dir DN00 PN0-6 A - B 00 mm 50/6/00 AF/50 00.6.8 5.7 960 Dir DN00 PN0-6 A - B 00 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Models with horizontal DN50 PN0-6 flanged delivery port - 6 poles P (kw) echnical data V Phases P (kw) P (kw) A Rpm Start 50/6/50 AF/50 00.6.8 5.7 960 Dir DN50 PN0-6 A - B 50 mm (*) A = 07RN-F G.5+x - 0 m (standard version). Electrical and mechanical features are equal to the cable H07RN-F B = NSSHOU-J G.5+x0.75-0 m (AEX version) 0 IPS Katalogus
electrical submersible pumps www.ipspumps.be Versions available (Key to versions on page 6) Electrical variants ooling Mechanical seals 50//G65V ADM/50 50//G65V AD/50 N A E D D D G G S S G S R R G N E F G F SI SIM SIAL SIAL 00//G65V AD/50 50//65 ADM/50 50//65 AD/50 00//65 AD/50 00//65 AF/50 550//65 AF/50 50//80 ADM/50 50//80 AD/50 00//80 AD/50 00//80 AF/50 550//80 AF/50 00//65 AD/50 00//65 AF/50 00//65 AF/50 00//80 AD/50 00//80 AF/50 00//80 AF/50 00//00 AD/50 00//00 AF/50 00//00 AF/50 50/6/65 AD/50 50/6/80 AD/50 50/6/00 AD/50 50/6/00 AF/50 50/6/50 AF/50 he version complete with probe is not available with AEX certificate. NOE FOR SINGLE PHASE PUMPS: thermal protections into the winding have to be connected to the electrical panel. Start capacitor inside the pump. ircuit breaker supplied but not connected to the pump cable. he use of an electrical panel as circuit breaker housing is mandatory. For installation please see use and maintenance instructions booklet. 0 IPS Katalogus
www.ipspumps.be electrical submersible pumps Overall dimensions and weights Models with vertical delivery port Models with horizontal delivery port A B D E E (*) F G H J J kg 50//G65V ADM()/50 0 0 560 5 G / 65 0 - - - - 9 00//G65V AD/50 0 0 560 5 G / 65 0 - - - - 5 50//65 ADM()/50 00 0 560 60 65 65 0 8 5 90-5 00//65 AD/50 0 0 580 80 65 65 50 8 5 90-5 00//65 AF/50 0 0 70 80 65 65 50 8 5 90-7 550//65 AF/50 0 0 70 80 65 65 50 8 5 90-78 50//80 ADM()/50 0 0 585 80 80 80 0 8 60 90 5 5 00//80 AD/50 5 5 585 80 80 80 5 8 60 90 5 55 00//80 AF/50 5 5 75 80 80 80 5 8 60 90 5 75 550//80 AF/50 5 5 75 80 80 80 5 8 60 90 5 79 00//65 AD/50 90 55 595 70 65 65 05 8 5 90-6 00//65 AF/50 90 55 700 70 65 65 05 8 5 90-78 00//65 AF/50 90 55 700 70 65 65 05 8 5 90-8 00//80 AD/50 85 55 60 80 80 80 00 8 60 90 5 6 00//80 AF/50 85 55 70 80 80 80 00 8 60 90 5 79 00//80 AF/50 85 55 70 80 80 80 00 8 60 90 5 8 00//00 AD/50 0 60 65 90 00 00 05 8 80 5-66 00//00 AF/50 0 60 70 90 00 00 05 8 80 5-8 00//00 AF/50 0 60 70 90 00 00 05 8 80 5-85 50/6/65 AD/50 90 55 595 70 65 65 05 8 5 90-6 50/6/80 AD/50 85 55 60 80 80 80 00 8 60 90 5 6 50/6/00 AD/50 0 60 65 90 00 00 05 8 80 5-66 50/6/00 AF/50 95 90 770 90 00 00 75 8 80 5-50/6/50 AF/50 550 5 85 0 50 50 00 0 5 - Measurements in mm (*) DN of the suction flange - PN6 0 IPS Katalogus