Water Specialist 1 & 1.25 Motorized Alternating Valve

Similar documents
Motorized Alternating Valve

Control Valves, Fittings and Accessories

Control Valves, Fittings and Accessories

Water Specialist WS2H and WS3 Control Valve Drawings and Service Manual

Water Specialist CI Control Valve Programming and Cover Drawing Manual

Water Specialist EE Control Valve Programming and Cover Drawing Manual

Water Specialist EI Control Valve Programming and Cover Drawing Manual

TTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

Water Specialist WS1TT Drawings and Service Manual

Iron Blaster System Owner s Manual

Commercial Softeners

Water Specialist WS1TT Drawings and Service Manual

Water Specialist 1.5, 2 and 2 QC Control Valve Drawings and Service Manual

TABLE OF CONTENTS JOB SPECIFICATIONS

WS1TC Series Installation and Operation Manual

Superior Water And Air

Trouble Shooting Guide for WS1 - WS2 Control Valves

Water Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER FILTER TIME CLOCK MODEL FEATURING THE 2002F VALVE

INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER SOFTENER TIME CLOCK MODEL FEATURING THE 2002S VALVE

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

Manual for Operation & Maintenance Of Metered Carbon Filter

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

Water Specialist WS2H and WS3 Control Valve Manual

7-LXC-50B 7-LXC-75B 7-LXC-100B 7-LX-75B 7-LX-100B 7-LX-150B 7-LX-200B 7-LX-300B

Panel Operation Quick Reference Guide

Value Super Filter Max Installation Manual

Installation and Service Manual Backwash Filter Systems

Water Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI

SmartChoice. Gen II itwin. Water Conditioning System. Installation, Operation, and Maintenance Manual. Installation, Operation, and Maintenance Manual

Owner s Manual HELLENBRAND, INC.

WS2H/ WS3 Error Codes

7-LX B 7-LX B 7-LX B 7-LX B 7-LX B

UF Series. Twin Membrane Filtration System. Model CCUF-844TW

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

Inverted High Pressure Fluid Filters

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

DCS7 Water Softener - Product Manual

SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE

Impression Plus Series Sanitizer Plus Series

GF Series Water Softener

OZONE ZENTEC CAPSULATE FILTER INSTALLATION AND USER GUIDE

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

Sanitizer Plus Series. Water Conditioners

Watco Pro Series Water Conditioner

Model WS1 Demand. Operation & Maintenance Manual. 114 Vista Parkway Avon, IN New Aqua L.L.C.

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

Problem and Solutions Manual

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Model Downlow & Uplow

Owner s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

Water Specialist 1.5" CC Control Valve Programming and Drawings Manual

65 Series. Valve Operation Manual

Installation Instructions For EZ-View Flow Meter and EZ-View Flow-Alert Flow Meter FORM # HLIT 300 I. INTRODUCTION II. OPERATING PRINCIPLE

H-125 HE SERIES. Owner s Manual HIGH EFFICIENCY SYSTEM. Manufactured by: HELLENBRAND, INC. Web:

INSTALLATION INSTRUCTIONS

TotalCare, CareSoft Elite. and CareSoft Pro. Series. Twin Water Softeners and Conditioners. For Models: TC1-TW TC2-TW CSE-TW CSP-TW CSERC-TW CSPRC-TW

Impression Series. Installation Instructions & Owner s Manual. Metered Water Softeners

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

Installation and Operations Manual

SERVICE MANUAL HD 2.5/27 PB AL HD 3.7/35 PB AL PGA PGA BXA BXA BGA BGA

Installation / Operation Manual

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

Sanitizer Plus Series

INSTALLATION INSTRUCTIONS

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

UF Series. Membrane Filtration System. Model CCUF-844

wd-2

UF Series. Membrane Filtration System. Model CCUF-844

SERVICE MANUAL MODEL # ORDER # XPERT-HD 3.8/35 P PD DA DD

ONE. Cartridge Tank Filters

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

ONE. Cartridge Tank Filters

Impression Plus Series

+\YH4(*;4 >H[LY 7YLZZ\YL )VVZ[LY :`Z[LT 0UZ[HSSH[PVU 0UZ[Y\J[PVUZ +\YH4(*

INSTALLATION & OWNER S MANUAL

Installation Instructions & Owner s Manual. Omega Series Metered Water Softeners

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

Owner s Manual. Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin

Spare Parts List ( ) Clipper V

Fleck Top Mount Section 1 Fiberglass Softeners

Intellicarb 2323 EXPLODED VIEW PARTS LIST. IC2323 Drop-In Ice Cooled 6 & 8 Valve Dispensers with McCann Carbonator Tank

STAY ON TRACK WITH THIS LINE FOLLOW BUGGY WITH :MOVE LINE FOLLOW BOARD FOR BBC MICRO:BIT

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

TotalCare Series. Water Conditioners

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

Impression Plus Series

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

SERVICE MANUAL

Impression Plus Series

Homesteader Personal Plow

FLECK 2850 CONTROL VALVE

Transcription:

Water Specialist 1 & 1.25 Motorized Alternating Valve Allows for twin alternating system Low voltage drive assembly controlled by valves circuit board Utilizes WS1 and WS1.25 Control Valve Fittings Full 1.25 ports for minimal pressure loss Provides choices of treated or non-treated water regeneration Order No. V3069FF F x F Proven and reliable Clack DC drive assembly Can be utilized with a single control valve system to accommodate a clean water source for regeneration Order No. V3069MM M x M Example of a Twin Configuration 4462 DURAFORM LANE WINDSOR, WISCONSIN 53598-9716 USA phone (608) 846-3010 fax (608) 846-2586 sales/customer service fax (800) 755-3010 www.clackcorp.com Form No. 2772 8/1/07

Order No. V3069FF Description: MOTOR ALT VLV 1/125 F-F or Order No. V3069MM Description: MOTOR ALT VLV 1/125 M-M Plan the position of the motorized alternator valve and control valves (each with their own meter) carefully because of the following: The 8 alternator valve motor cable (V3476) must be threaded through the back plate and connected to the two pin connector labeled DRIVE on the ALT A control valve board. Approximately 1 of the cable length should be allowed for weaving through the back plate. The 8 interconnect cable (V3474-01) must be threaded through the back plates and connected to the three pin connector labeled INTERCONNECT CABLE on both the ALT A and ALT b control valves. Approximately 2 of the cable length (1 for each control valve) should be allowed for weaving through the back plate. NOTE: Although the interconnect cable V3474-01 has two wires, it must be connected to the three pin connector. The 15 AC Adapter or power cable must be thread through the back plate of both the ALT A and ALT b control valves. Approximately 1 of the cable length should be allowed for weaving through the back plate. The AC adapter should be installed to a properly grounded, not switched, outlet. Try to allow suffi cient slack in cables so cables may be zip tied to plumbing lines to prevent the cables from being accidentally pulled. Where necessary, break out the tab in the back plate to allow two cables to be woven through the same slot in the back plate. No more than two cables may be woven through one back plate slot. To help prevent damage to cables, allow solder joints to cool or solvent cement joints to cure after completing the various service, drain and regenerant plumbing connections. Thread the various cables through the appropriate back plate(s) and connect as described in the bullets above. Service Water Plumbing Connections See exploded view for fi tting connections. Connect the water service line to the water inlet of control valves programmed as ALT A and ALT b. Connect the outlet of the control valve programmed as ALT A to the port labeled A on the alternator valve. Connect the outlet of the control valve programmed as ALT b to the port labeled B on the alternator valve. ALT A control valve is in service when the threaded portion of the motorized alternating valve drive gear is not visible in the clear dome of the cover. If the control valve manual does not include instructions for setting up ALT A and ALT b software, visit www.clackcorp.com to download the current copy of the instructions. V3069FF Female ports, labeled A or B, may be connected using Clack fi tting packages. The motorized alternating valve outlet accepts Clack fi tting packages or may be removed to use 1½ NPT threaded outlet. A B A B Treated water out See exploded view if ½ NPT if connection is desired V3069MM Male ports, labeled A or B, may be connected directly to a Clack 1 or 1.25 control valve outlet or to a V3191-01 vertical bypass adapter assembly. The motorized alternating valve outlet accepts Clack fi tting packages or may be removed to use 1½ NPT threaded outlet. 1" or 1.25" Metered Control Valve ALTA 1" or 1.25" Metered Control Valve ALTb Form No. V3115-30 6/14/07 Untreated water in

Order No. V3069FF Description: MOTOR ALT VLV 1/125 F-F or Order No. V3069MM Description: MOTOR ALT VLV 1/125 M-M Drawing No. Order No. Description Quantity V3069FF V3069MM 1 V3073 MAV/NOHWBY COVER ASY 1 1 2 V3476 WS MOTOR ASY 8 FT 1 1 3 V3592 SCREW #8-3/4 PHPN T-25 SS 3 3 4 V3262-01 WS1.5&2ALT/2BY REDUCGEARCVRASY 1 1 5 V3110 WS1 DRIVE GEAR 12X36 3 3 6 V3264 WS2 BYPASS REDUCTION GEAR AXLE 3 3 7 V3527 SCREW 1/4-20 X 3/4 BHSCS SS 4 4 8 V3072 MAV/NOHWBY 1/125/15 DRIVE ASY 1 1 9 V3506-01 MAV/NOHRD 1/125/15 PISTON 1 1 10 V3074 MAV/NOHWBY 1/125/15 STACK ASY 1 1 11 V3504FF MAV BODY 1/125 ASY F-F 1 N/A 12 V3504MM MAV BODY 1/125 ASY M-M N/A 1 13 V3151 WS1 NUT 1 QC N/A 2 14 V3150 WS1 SPLIT RING N/A 2 15 V3105 O-RING 215 N/A 2 Not Shown V3474-01 WS ALT MAV 1/125 CORD 8FT BLK 1 1 1 2 1½ NPT Threads 3 4 Quick Connect Nut Threads can be cut off to allow access to 1½ NPT Threads. Deburr and clean edge after cutting. NOTE: Tefl on tape is required when using the 1½ NPT Threads. 5 6 7 8 13 14 15 12 9 11 10 Female ports, labeled A or B, may be connected using Clack fi tting packages. The motorized alternating valve outlet accepts Clack fi tting packages or may be removed to use 1½ NPT threaded outlet. Male ports, labeled A or B, may be connected directly to a Clack 1 or 1.25 control valve outlet or to a V3191-01 vertical bypass adapter assembly. The motorized alternating valve outlet accepts Clack fi tting packages or may be removed to use 1½ NPT threaded outlet. Form No. V3115-30 6/14/07