PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

Similar documents
CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

DIESEL GENERATOR SET FEATURES

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Voltage 220 to or 1800 RPM

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 225 ekw 281 kva

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

Caterpillar 2500 kw 3516C

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

STANDBY 400 ekw 500 kva

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Specifications. 3406C Generator Set Electric Power

Prime 455 ekw kva 60 Hz 1800 rpm 480 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

220 to volts. Electronic unit injection

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

Specifications. C13 Generator Set Electric Power

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

400 to 11,000 Volts. Standby, Prime, Continuous

Standby 500 ekw 625 kva 60 Hz 1800 rpm 480 Volts

STANDBY 4000 ekw 5000 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

Transcription:

DIESEL GENERATOR SET PRIME 920 ekw 1150 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FUEL/EMISSIONS STRATEGY Low fuel consumption DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat S O S SM program effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by products. CAT 3512 DIESEL ENGINE Reliable, rugged, durable design Four-stroke diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT SR5 GENERATOR Matched to the performance and output characteristics of Cat engines Single point access to accessory connections UL 1446 Recognized Class H insulation CAT EMCP 3 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner [ ] Dual element & heavy duty air cleaners Service indicator [ ] Air inlet adapters & shutoff Cooling Exhaust Fuel Generator Radiator with guard Coolant drain line with valve Fan and belt guards Cat Extended Life Coolant* Dry exhaust manifold Flanged faced outlets Secondary fuel filters Fuel priming pump Flexible fuel lines Fuel cooler* Class H insulation Cat digital voltage regulator (CDVR) with kvar/pf control, 3-phase sensing Reactive droop [ ] Radiator duct flange [ ] Jacket water heater [ ] Mufflers and silencers [ ] Stainless steel exhaust flex fittings [ ] Elbows, flanges, expanders & Y adapters [ ] Water separator [ ] Duplex fuel filter [ ] Oversize & premium generators [ ] Winding temperature detectors [ ] Bearing temperature detectors [ ] Anti-condensation space heaters Power Termination Bus bar (IEC mechanical lug holes) Top cable entry [ ] Circuit breakers, IEC compliant, 3 or 4 pole with shunt trip (low voltage only), choice of trip units, manual or electrically operated [ ] Bottom cable entry [ ] Power terminations can be located on the right, left and/or rear as an option. Governor Woodward 2301A isochronous [ ] Electronic load sharing governor Control Panel EMCP 3.1 User Interface panel (UIP) - wall mounted AC & DC customer wiring area (right side) Emergency stop pushbutton Lube Mounting Starting / Charging General Lubricating oil and filter Oil drain line with valves Fumes disposal Gear type lube oil pump Rails - Engine / generator / radiator mounting Rubber anti-vibration mounts (shipped loose) 24 volt starting motor Battery rack with cables Battery disconnect switch Right hand service Paint - Caterpillar Yellow (with high gloss black rails & radiator) SAE standard rotation Flywheel and flywheel housing - SAE No. 00 [ ] EMCP 3.2... [ ] EMCP 3.3 [ ] Option for Right or left mount UIP [ ] Local & remote annunciator modules [ ] Digital I/O Module [ ] Generator temperature monitoring & protection [ ] Remote monitoring software [ ] Oil level regulator [ ] Deep sump oil pan [ ] Electric & air prelube pumps [ ] Duplex oil filter [ ] Manual prelube with sump pump [ ] Isolator removal [ ] Spring-type vibration isolator (shipped loose) [ ] IBC Isolator [ ] 45 amp charging alternator [ ] Battery chargers (5 or 10 Amp) [ ] Oversize batteries [ ] Heavy duty starting motors [ ] Ether starting aids [ ] Barring device (manual) [ ] CSA certification [ ] CE Certificate of Conformance [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 * Not included with packages without radiators 2

SPECIFICATIONS CAT GENERATOR Frame.. 1424 Excitation.. IE Pitch 0.6667 Number of poles. 4 Number of bearings.. Single Bearing Insulation.Class H IP rating. IP23 Over speed capability - % of rated 150% Wave form deviation. 3% Voltage regulator. 3 phase sensing with load adjustable module Telephone Influence Factor.Less than 50 Harmonic Distortion..Less than 5% CAT DIESEL ENGINE 3512 TA, V-12, 4 stroke, water-cooled diesel Bore.170.00 mm (6.69 in) Stroke..190.00 mm (7.48in) Displacement 51.80 L (3161.03 in 3 ) Compression ratio...13.5:1 Aspiration...TA Fuel system..direct unit injection Governor Type Woodward CAT EMCP 3 CONTROL PANELS EMCP 3.1 Standard EMCP 3.2 & 3.3 (Optional) 24 Volt DC Control Single location for customer connection Auto start/stop control True RMS metering, 3-phase Digital indications for: - RPM - Operating hours - Oil pressure - Coolant temperature - System DC volts - L-L volts, L-N volts, Phase amps, Hz - ekw, kva, kvar, kwhr, %kw, PF (EMCP 3.2/3.3) Shutdowns with common indicating light for: - Low oil pressure - High coolant temperature - Low coolant level - Overspeed - Emergency stop - Failure to start (overcrank) Programmable protective relaying functions (EMCP 3.2 & 3.3) - Under and over voltage - Under and over frequency - Reverse power - Overcurrent Modbus isolated data link (RS-485 half-duplex EMCP 3.2 & 3.3) 3

TECHNICAL DATA Open Generator Set - 1500 rpm/50 Hz/400 Volts Package Performance Power rating Power rating @ 0.8 pf Fuel Consumption 100% load with fan 75% load with fan 50% load with fan 920 ekw 1150 kva PRIME DM8219 241.8 L/hr 63.9 Gal/hr 185.2 L/hr 48.9 Gal/hr 129.1 L/hr 34.1 Gal/hr Cooling System* Engine coolant Capacity with radiator arrangement) Engine coolant capacity Radiator coolant capacity 286.8 L 75.8 US Gal 156.8 L 41.4 US Gal 130.0 L 34.3 US Gal Inlet Air Combustion air inlet flow rate 84.0 m 3 /min 2966.4 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator** Motor starting capability @ 30% voltage dip Frame Temperature Rise 451.3 C 844.3 F 212.5 m 3 /min 7504.4 cfm 203.2 mm 8 in 6.7 kpa 26.9 in. water 556 kw 31619.7 Btu/min 916 kw 52092.8 Btu/min 125 kw 7108.7 Btu/min 111 kw 6312.6 Btu/min 53.5 kw 3042 Btu/min 2883 SKVA 1424 125 C 225 F Lube System Lube oil refill volume with filter change for standard sump 310.4 L 82.0 US Gal Emissions (Nominal) NO x mg/nm 3 CO mg/nm 3 HC mg/nm 3 PM mg/nm 3 * For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. ** UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Prime Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of the prime rated ekw with overload capability equal to the standby rating available for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Prime power in accordance with ISO 3046. Prime ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions Fuel Rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Caterpillar representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. 5

DIMENSIONS Package Dimensions Length 5137.1 mm 202.25 in Width 1974.8 mm 77.75 in Height 2367.2 mm 93.2 in Weight 11,280 kg 24,868 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. www.cat-electricpower.com Performance No.: DM8219 Feature Code: 512DE6U Gen. Arr. Number: 252-3774 Sourced: European Sourced 2011 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. (01-11) CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the Power Edge trade dress as well as corporate and product identity used herein, are 6 trademarks of Caterpillar and may not be used without permission.